Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 122
Filtrar
1.
Eur J Orthop Surg Traumatol ; 34(4): 2179-2184, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38573381

RESUMO

PURPOSE: To identify associations with unplanned repeat irrigation and debridement (I&D) after arthrotomy for native septic arthritis. METHODS: A retrospective review identified patients with native septic arthritis treated with open arthrotomies. The primary outcome was unplanned repeat I&D within 90 days. Associations evaluated for included comorbidities, ability to bear weight, fever, immunosuppressed status, purulence, C-reactive protein, erythrocyte sedimentation rate, white blood cell count (synovial fluid and serum levels), and synovial fluid polymorphonuclear cell percentage (PMN%). RESULTS: There were 59 arthrotomies in 53 patients involving the knee (n = 32), shoulder (n = 10), elbow (n = 8), ankle (n = 6), and hip (n = 3). The median patient age was 52, and a 71.2% were male. An unplanned repeat I&D was required in 40.7% (n = 24). The median time to the second I&D was 4 days (interquartile range 3 to 9). On univariate analysis, unplanned repeat I&Ds were associated with fever (p = 0.03), purulence (p = 0.01), bacteria growth on cultures (p = 0.02), and the use of deep drains (p = 0.05). On multivariate analysis, the only variables that remained associated with unplanned repeat I&Ds were fever (odds ratio (OR) 5.5, 95% confidence interval (CI) 1.3, 23.6, p = 0.02) and purulence (OR 5.3, CI 1.1, 24.4, p = 0.03). CONCLUSIONS: An unplanned repeat I&D was required in 40.7% of patients and was associated with fever and purulence. These findings highlight the difficulty of controlling these infections and support the need for future research into better methods of management. LEVEL OF EVIDENCE: Diagnostic, Level III.


Assuntos
Artrite Infecciosa , Desbridamento , Irrigação Terapêutica , Humanos , Artrite Infecciosa/terapia , Artrite Infecciosa/cirurgia , Masculino , Desbridamento/métodos , Irrigação Terapêutica/métodos , Feminino , Estudos Retrospectivos , Pessoa de Meia-Idade , Adulto , Reoperação/estatística & dados numéricos , Líquido Sinovial/microbiologia , Idoso , Febre/etiologia , Proteína C-Reativa/análise , Contagem de Leucócitos
2.
Artigo em Inglês | MEDLINE | ID: mdl-38573380

RESUMO

PURPOSE: To review surgical complications after fixation of stress-positive minimally displaced (< 1 cm) lateral compression type 1 (LC1) pelvic ring injuries. METHODS: A retrospective study at a level one trauma center identified patients who received surgical fixation of isolated LC1 pelvic ring injuries. Surgical complications and additional procedures were reviewed. RESULTS: Sixty patients were included. The median age was 61 years (Interquartile range 40-70), 65% (n = 39) were women, and 57% (n = 34) had high-energy mechanisms. Anterior-posterior, posterior-only, and anterior-only fixation constructs were used in 77% (n = 46), 15% (n = 9), and 8% (n = 5) of patients. Anterior fixation was performed with rami screw fixation in 82% (49/60), external fixation in 2% (1/60), and open reduction and plate fixation in 2% (1/60). There were 15 surgical complications in 23% (14/60), and 12 additional procedures in 17% (10/60). Complications included loss of reduction ≥ 1 cm (8%), symptomatic hematomas (8%), symptomatic backout of unicortical retrograde rami screws (5%), deep infection of the pelvic space after a retrograde rami screw (1.6%), and iatrogenic L5 nerve injury (1.6%). All losses of reduction involved geriatric females with distal rami fractures sustained in ground-level falls. Loss of reduction was found to be more likely in patients with low energy mechanisms (proportional difference (PD) 62%, 95% confidence interval (CI) 18% to 76%; p = 0.01) and 2 versus 1 posterior pelvic screws (PD 36%; CI 0.4% to 75%; p = 0.03). CONCLUSIONS: Surgical complications and additional procedures routinely occurred after fixation of LC1 injuries. Patients should be appropriately counseled on the risks of surgical fixation of these controversial injuries. LEVEL OF EVIDENCE: Diagnostic, Level III.

3.
Calcif Tissue Int ; 113(3): 257-265, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37326840

RESUMO

Our objective was to determine the prevalence of osteomalacia in low-energy hip fracture patients over the age of 45, based on biochemical and histological measures. This cross-sectional study included 72 patients over 45 with low-energy mechanism hip fractures. Samples of fasting venous blood were taken for hemograms and serum biochemistry analyses. Bicortical biopsies of the iliac crest were obtained, processed, and evaluated by an expert pathologist for osteomalacia. Biochemical osteomalacia (b-OM) is defined according to a distinct criterion. A low level of serum calcium, phosphorus, albumin, and 25OHD was found in 43.1, 16.7, 73.6, and 59.7% of patients, respectively. 50.0% of patients had high serum alkaline phosphatase (ALP) levels. b-OM was found in 30 (41.7%), and no significant association was found with PTH, Cr, Alb, age, sex, fracture type, side of the trauma, and season were not associated with osteomalacia. Osteomalacia was diagnosed on histopathological analysis in 19/72 (26.7%), and 54/72 (75.0%) of all cases fulfilled b-OM criteria. In the histologic evaluation, osteoid seam width, osteoid surface, and osteoid volume were 28.5 µm, 25.6, and 12.1%, respectively. The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of the biochemical test for detecting osteomalacia were 73.6, 64.2, 42.4, 87.2, and 66.7%, respectively. Up to 30% of elderly patients with low-energy hip fractures are affected by osteomalacia. A biochemical screening along with a bone biopsy and histopathologic evaluation may be logical in a high-risk population for osteomalacia diagnosis.


Assuntos
Fraturas do Quadril , Osteomalacia , Idoso , Humanos , Estudos Transversais , Fraturas do Quadril/complicações , Ílio/patologia , Ílio/cirurgia , Osteomalacia/complicações , Osteomalacia/diagnóstico , Osteomalacia/epidemiologia , Osteomalacia/patologia , Prevalência , Pessoa de Meia-Idade , Biópsia , Idoso de 80 Anos ou mais , Masculino , Feminino , Biomarcadores/sangue , Biomarcadores/urina , Análise Química do Sangue/normas , Sensibilidade e Especificidade
4.
Eur J Orthop Surg Traumatol ; 33(1): 37-43, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34716497

RESUMO

PURPOSE: To determine if there is an association between pre-/postoperative translational and angular displacement with nonunion after intramedullary nail (IMN) fixation of tibial shaft fractures. METHODS: Retrospective review of 120 patients with tibial shaft fractures undergoing IMN at an urban level-one trauma center was performed. Demographics, injury characteristics, and pre-/postoperative translational and angular fracture displacement in the coronal and sagittal planes were recorded. True fracture translational and angular displacement (TTD and TAD) were calculated by combining sagittal and coronal displacement utilizing the Pythagorean theorem. RESULTS: 10.8% of patients (n = 13) developed nonunion with remaining patients serving as the control. Groups were similar across age, sex, and BMI. Univariate analysis revealed no difference in pre-/postoperative TAD between nonunion and union groups and an increased preoperative TTD (median difference (MD): 6.2 mm, CI: 1.4-10.8 mm) and postoperative TTD (MD: 1.8 mm, CI: 0-3.7 mm) in the nonunion group. On multivariate analysis, however, only tobacco use and type 2 or 3 open fractures were associated with nonunion (OR: 5.1, CI: 1.2-22.8 and OR: 4.9, CI: 1.2-19.2, respectively). CONCLUSION: True translational and angular displacement of tibial shaft fractures before and after IMN fixation were not independently associated with nonunion. Tobacco use and type 2 or 3 open fracture are independent factors for nonunion.


Assuntos
Fixação Intramedular de Fraturas , Fraturas Expostas , Fraturas da Tíbia , Humanos , Fixação Intramedular de Fraturas/efeitos adversos , Fraturas da Tíbia/cirurgia , Fraturas Expostas/cirurgia , Pinos Ortopédicos/efeitos adversos , Análise Multivariada , Estudos Retrospectivos , Consolidação da Fratura , Resultado do Tratamento
5.
Eur J Orthop Surg Traumatol ; 33(5): 1675-1681, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35831489

RESUMO

PURPOSE: The purpose of this study was to analyze the patient/injury characteristics and associated hospital course of patients sustaining traumatic pelvic ring injuries after alpine ski and snowboard accidents at a level one trauma center in the Rocky Mountain region. METHODS: Patient/injury characteristics were obtained from patients presenting with pelvic ring injuries after alpine ski (n = 55) and snowboard (n = 9) accidents. Characteristics and outcomes analyzed included mechanism of injury, pelvic ring classification (Young-Burgess and Tile), hospital admission, physical therapy (PT) clearance, ambulation, length of stay, inpatient morphine milligram equivalents (MME), and discharges to rehabilitation facility. RESULTS: Snowboarders were more often younger, male, tobacco/substance users, and more likely to be injured by a fall from height than skiers. There were no differences in injury classification or hospital course outcomes between alpine sports. Most common injuries included lateral compression type 1 (LC1) injuries (37.5%), isolated pubic ramus fractures (31.3%), and isolated iliac wing fractures (15.6%). LC1 injuries were unstable in 50% of cases and associated with increased admissions (proportional difference: 47.5%, CI: 23.8-64.5%, p = 0.0002), longer time to PT clearance (median difference(MD): 1.0 day, CI: 0-2.0, p = 0.03), longer LOS (MD: 2.0, CI: 0-2.0, p = 0.02), and increased inpatient MMEs (MD: 197.9 MME, CI: 30.0-420.0, p = 0.02), as compared to other pelvic ring injuries. CONCLUSION: The majority of pelvic ring injuries from alpine ski and snowboard accidents were LC1 injuries, half of which were unstable, resulting in longer hospital stays, time to PT clearance/ambulation, and opioid use.


Assuntos
Lesões por Esmagamento , Fraturas Ósseas , Lesões do Quadril , Esqui , Fraturas da Coluna Vertebral , Humanos , Masculino , Esqui/lesões , Fraturas Ósseas/epidemiologia , Fraturas Ósseas/etiologia , Acidentes
6.
Eur J Orthop Surg Traumatol ; 33(5): 1905-1911, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36029341

RESUMO

PURPOSE: The purpose of this study was to compare patients with traumatic pelvic ring injuries sustained in road and mountain bicycling accidents to evaluate for differences in injury types and hospital courses. METHODS: A retrospective review of 60 patients presenting with pelvic ring injuries after road (n = 46) and mountain (n = 14) bicycling accidents was performed to compare patient/injury characteristics and hospital course. RESULTS: LC1 injuries were the most common pelvic ring injury (n = 31, 51.7%), 38.7% (n = 12) of which were considered unstable, followed by isolated iliac wing (n = 11, 18.3%), pubic rami (n = 6, 10.0%), and sacral fractures (n = 6, 10.0%). Hospital admission was required for 41 (68.3%) patients. The median hospital LOS was 4 days (IQR 2-9) and 12 (20%) patients received operative treatment. Patients in road versus mountain bicycling accidents were more likely to be older tobacco users and were similar in sex, body mass index, and injury severity score. Road bicycling resulted in more LC1 injuries (58.7% vs 28.6%, p = 0.04), while mountain bicycling resulted in more iliac wing fractures (42.9% vs. 10.9%, p = 0.01). Road cycling injuries required more days in the hospital to clear PT (median difference 2, CI 0-4, p = 0.04) and had longer hospital stays (median difference 2, CI 0-6, p = 0.02) but had no difference in the rate of admission, operative intervention, or discharge to rehabilitation facilities. CONCLUSION: The majority of pelvic ring injuries from road and mountain bicycling accidents were LC1 injuries that were frequently unstable and often required hospital admission and operative fixation.


Assuntos
Ciclismo , Fraturas da Coluna Vertebral , Humanos , Ciclismo/lesões , Acidentes , Ílio/lesões , Pelve , Estudos Retrospectivos
7.
Eur J Orthop Surg Traumatol ; 33(5): 1691-1695, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35861922

RESUMO

PURPOSE: Internal validation studies of National Surgical Quality Improvement Program (NSQIP) registry data have reported potential inaccuracies. The purpose of this study was to determine the accuracy of hip fracture CPT codes and complications entered into NSQIP for a single participating center. METHODS: A retrospective study identified patients with a hip fracture CPT code from NSQIP data at a single institution over a two-year period. CPT codes included 27235 (percutaneous fixation of femoral neck fracture (Perc FNFX)), 27236 (open treatment of femoral neck fracture, internal fixation/prosthetic replacement (Open FNFX)), 27244 (open treatment of inter/peri/subtrochanteric femoral fracture with plate (Plate ITFX)), 27245 (treatment of inter/peri/subtrochanteric femoral fracture, with intramedullary implant (IMN ITFX)), and 27125 (hemiarthroplasty (HA)). The institutional medical record was reviewed to determine the accuracy of CPT code and 30-day complication data entered into the registry. RESULT: 12.8% (n = 20/156) of patients had an inaccurate CPT code. The proportion of inaccurate CPT codes varied significantly by procedure: Plate ITFX (76.9%), Open FNFX (13.8%), IMN ITFX (7.0%), and HA (0%) (p < 0.0001). A total of 82 complications were identified in 66 patients via the medical record. 43.9% (n = 36/82) of these complications were not documented in the NSQIP data. The proportion of missing complications varied significantly by type: renal (100%), UTI (53.8%), infection (50%), bleeding (30%), death (25%), respiratory (25%), cardiac (0%), stroke (0%), and VTE (0%) (p < 0.0001). CONCLUSION: Hip fracture CPT codes and 30-day complication data entered into the NSQIP registry were frequently inaccurate. Studies incorporating NSQIP data should acknowledge these potential limitations of the registry, and future research to validate NSQIP orthopedic data across procedures and institutions is necessary. LEVEL OF EVIDENCE: LEVEL III: Diagnostic study.


Assuntos
Fraturas do Colo Femoral , Fraturas do Quadril , Humanos , Melhoria de Qualidade , Estudos Retrospectivos , Fraturas do Quadril/cirurgia , Fraturas do Quadril/complicações , Fraturas do Colo Femoral/cirurgia , Fraturas do Colo Femoral/complicações , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia
8.
Eur J Orthop Surg Traumatol ; 33(6): 2525-2532, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36581699

RESUMO

PURPOSE: To assess the morbidity of open reduction internal fixation (ORIF) of posterior malleolus fractures (PMFs) in the setting of trimalleolar ankle fractures. METHODS: A retrospective review of 79 trimalleolar ankle fractures was performed to identify need for syndesmotic fixation, blood loss, operative/tourniquet time, complications, and reoperations. Patients with PMF ORIF (n = 38) were compared to those with no fixation (n = 41). A subanalysis of patients with small PMFs (< 25%) was performed. RESULTS: The PMF ORIF group required less syndesmosis fixation (proportional difference (PD) - 44.6%, 95% confidence interval (CI) - 61.8 to - 23.0%), had more blood loss (MD 20 ml, CI 0-40), longer operative times (MD 53.0 min, CI 35.9-70.1), longer tourniquet times (MD 26 min, CI 4-33), and had no difference in postoperative joint step-off or concentrically reduced joints. The PMF ORIF group had more postoperative complications (PD 26.9%, CI 6.3-44.8%) and a trend for more reoperations (PD 13.6%, CI -3.4 to 29.6%). Wound complications were more common in the PMF ORIF group (PD 26.5%, CI 6.9-43.6%), resulting in 5 (16.1%) irrigation and debridement procedures. On analysis of patients with small PMFs (n = 42), PMF ORIF (n = 15) resulted in longer operative/tourniquet times and had no observed difference in postoperative joint step-off, concentrically reduced joints, need for syndesmotic fixation, blood loss, or complications/reoperations. CONCLUSION: PMF ORIF in the setting of trimalleolar ankle fractures was associated with increased operative/tourniquet times, blood loss, wound complications, and did not eliminate the need for syndesmosis fixation.


Assuntos
Fraturas do Tornozelo , Humanos , Fraturas do Tornozelo/cirurgia , Fixação Interna de Fraturas/efeitos adversos , Fixação Interna de Fraturas/métodos , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Tíbia , Estudos Retrospectivos , Morbidade , Resultado do Tratamento
9.
Eur J Orthop Surg Traumatol ; 33(5): 1965-1971, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36056970

RESUMO

PURPOSE: The purpose of this study was to review the practice of utilizing lateral stress radiographs (LSRs) to identify occult instability (≥ 10 mm of dynamic displacement on LSRs) of minimally displaced lateral compression type 1 (LC1) pelvic ring injuries and to evaluate for associations between instability and patient demographics, injury characteristics, and hospital course. METHODS: A retrospective review of a prospective registry from 2018 to 2022 identified 151 patients with LC1 injuries. LSRs were obtained in 86.8% (131/151) of patients. Three (2.2%) patients were excluded for malrotation of LSRs, leaving 128 patients for analysis. RESULTS: The median maximum dynamic displacement on LSRs was 12.2 mm (IQR: 5.9 to 17.3). Occult instability was present in 62.5% (80/128) of patients and was associated with older age (Median difference 11.0 years, 95% CI 3.0 to 20.0), Nakatani type 1 rami fractures (73.7% vs. 47.9%, p = 0.001), and rami fracture comminution (Proportional difference 58.7%, 95% CI 42.8 to 71.3%), but not gender, high-energy mechanism, bilateral rami fractures, Denis classification, sacral fracture completeness, or sacral comminution. Patients with occult instability took longer to ambulate 15 feet and clear physical therapy (PT), were more likely to be unable to clear PT by hospital day 3 or by time of discharge, had longer hospital stays, and were more likely to require rehabilitation facilities. CONCLUSION: LSRs were obtained in a majority of patients. Occult instability was frequently present and associated with older age, comminuted distal pubic rami fractures, longer hospital stays, longer times to mobilize and clear PT, and an increased need for rehabilitation facilities.


Assuntos
Anestesia , Fraturas Ósseas , Fraturas Cominutivas , Ossos Pélvicos , Fraturas da Coluna Vertebral , Humanos , Ossos Pélvicos/diagnóstico por imagem , Ossos Pélvicos/lesões , Fraturas Ósseas/complicações , Fraturas Ósseas/diagnóstico por imagem , Fraturas Ósseas/cirurgia , Radiografia , Sacro/diagnóstico por imagem , Sacro/lesões , Fraturas da Coluna Vertebral/diagnóstico por imagem , Estudos Retrospectivos , Fraturas Cominutivas/diagnóstico por imagem
10.
Eur J Orthop Surg Traumatol ; 33(5): 2069-2074, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36197500

RESUMO

PURPOSE: To assess the reliability of a standardized measurement of screw breach on postoperative computed tomography (CT) scans following percutaneous fixation of the posterior pelvic ring. METHODS: Three orthopedic trauma surgeons independently utilized a standardized method of measuring posterior pelvic ring screw breaches on post-operative CT scan images. Breaches were measured as a continuous variable on sagittal images reformatted to be perpendicular to the screw on axial images. The inter-rater and intra-rater reliability of screw breach distance measurements was assessed. RESULTS: Measurements were performed on 42 screws in 20 patients. Screw types included S1-iliosacral (IS) (n = 16), S1-transsacral (TS) (n = 8), S2-IS (n = 2), and S2-TS (n = 16). Patients with varying degrees of screw breaches were chosen to test measurements across breach severities, including 0 mm (n = 10), ≤ 2 mm (n = 12), > 2 to 4 mm (n = 11), and > 4 mm (n = 9). The mean difference and 95% confidence interval (CI) between screw breach measurements between the three surgeons was - 0.13 mm (CI - 0.48 to 0.20), 0.05 mm (CI - 0.6 to 0.7), and 0.18 mm (CI - 0.47 to 0.85), respectively. The inter-rater reliability of the measurements was considered excellent (intraclass correlation coefficient (ICC), 0.93). The mean intra-rater reliability for the observers was considered good (ICC 88.5, CI 82 to 95). CONCLUSIONS: This simple standardized method of measuring screw breaches had excellent inter-rater reliability and would support comparisons of screw breach severity across studies. LEVEL OF EVIDENCE: Level III.


Assuntos
Fraturas Ósseas , Ossos Pélvicos , Humanos , Sacro/diagnóstico por imagem , Sacro/cirurgia , Sacro/lesões , Fixação Interna de Fraturas/efeitos adversos , Fixação Interna de Fraturas/métodos , Reprodutibilidade dos Testes , Fraturas Ósseas/diagnóstico por imagem , Fraturas Ósseas/cirurgia , Parafusos Ósseos/efeitos adversos , Tomografia Computadorizada por Raios X/métodos , Ossos Pélvicos/diagnóstico por imagem , Ossos Pélvicos/cirurgia , Ossos Pélvicos/lesões
11.
Eur J Orthop Surg Traumatol ; 33(5): 1721-1725, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35922640

RESUMO

PURPOSE: A ratio of observed difference (OD) over the 95% confidence interval (CI) has been shown to be strongly associated with the perceived clinical relevance (CR) of medical research results. The purpose of this study was to evaluate the association between the OD/CI ratio and perceived CR in orthopaedic research. METHODS: Sixty-seven orthopaedic surgeons completed a survey with 15 study outcomes (mean difference and CI) and were asked if they perceived the findings as clinically relevant. The interobserver reliability of perceived CR and the association between CR and the OD/CI ratio and p-value were assessed. RESULTS: The interobserver reliability of CR between respondents was moderate (kappa = 0.46, CI 0.45 to 0.48). P-values did not differ between results with and without CR (median difference (MD) - 0.12, CI - 0.74 to 0.0009, p = 0.07). The OD/CI ratio, however, was greater for results with CR (MD 1.01, CI 0.3 to 3.9, p = 0.004). The area under the curve (AUC) for the p-value and OD/CI ratio receiver operating characteristic (ROC) curves was 0.80 (p = 0.01) and 0.97 (p = 0.0003). The cutoff p -value and OD/CI ratio that maximized the sensitivity (SN) and specificity (SP) for CR were 0.001 (SN 80%, SP 80%) and 0.84 (SN 100%, SP 90%). The SN and SP of a p-value cutoff of 0.05 was 100% and 50%. CONCLUSION: The interobserver reliability of the perceived CR of orthopaedic research findings was moderate. The OD/CI ratio, in contrast to the p-value, was strongly associated with perceived CR making it a potentially useful measure to evaluate research results.


Assuntos
Ortopedia , Humanos , Reprodutibilidade dos Testes , Relevância Clínica , Sensibilidade e Especificidade , Curva ROC
12.
Artigo em Inglês | MEDLINE | ID: mdl-38104045

RESUMO

PURPOSE: To compare the success rate of a trial of labor (TOL) in a cohort of patients with pelvic fractures, with and without internal fixation, in order to better counsel patients and avoid unnecessary cesarean section (CS). METHODS: A retrospective review of 35 female patients with 28 pelvic ring, five acetabular, and two combined fractures that had subsequent pregnancy; 12 patients had operative fixation and 23 did not. Fracture classification, treatment, type of fixation, mode of deliveries, and reason for CS were documented. RESULTS: The rate of vaginal delivery, unscheduled CS, and scheduled CS across all patients was 80.0% (n = 28), 14.3% (n = 5), and 5.7% (n = 2), respectively, which was similar to institutional rates of 87.0, 12.0, and 1.0%. A TOL was attempted in 91.4% (32/35) and successful in 87.5% (28/32). Patients who failed a TOL were more likely to have Tile B/C pelvic fractures (100.0 vs. 30.4%, observed difference (OD) 69.6%, 95% confidence interval (CI) 16.4, 86.3%; p = 0.01) and more pelvic displacement (6.0 vs. 1.5 mm, OD 4.0, CI 1.0, 18.0; p = 0.01). The fixation and control groups had no observed difference in successful TOL (72.7% vs. 95.2%, OD 22.5%, - 49.7%, 5.5%; p = 0.10). CONCLUSIONS: A majority of women had successful vaginal deliveries after pelvic fractures, with or without fixation, suggesting that these patients should consider a TOL. LEVEL OF EVIDENCE: Diagnostic Level III.

13.
Eur J Orthop Surg Traumatol ; 33(4): 1263-1266, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-35604477

RESUMO

PURPOSE: The presence of air on computed tomography (CT) scans has been demonstrated to accurately diagnose occult traumatic arthrotomies. The purpose of this study was to determine if the presence of air on CT scans also has diagnostic utility for type 1 open fractures. METHODS: A retrospective review at a level 1 trauma center identified twenty-eight patients with Gustilo-Anderson Type 1 open fractures and preoperative CT scans. These patients were matched 2:1 with 56 closed fractures who also had CT scans. CT scans were reviewed to determine the presence of suprafascial and subfascial air. RESULTS: Air near the fracture site on CT scan was more common in open fractures then closed fractures (21 (75%) vs. 9 (16%) patients, proportional difference: 59% (37-75%), p < 0.0001). In the open fracture group, 18 (64.2%) patients had both supra- and subfascial air, 2 (7.1%) patients had isolated subfascial air, and 1 (3.5%) patient had isolated suprafascial air. In the closed fracture group, 3 (5.3%) patients had supra- and subfascial air, 4 (7.1%) had isolated subfascial air, and 2 (3.5%) had isolated suprafascial air. The sensitivity and specificity of air on CT for identifying a type 1 open fracture was 75 and 84%, respectively. CONCLUSIONS: This study found that the presence of air on CT scan was more likely in type 1 open versus closed fractures; however, the sensitivity or specificity was too low to be used reliably to identify occult open fractures in isolation. LEVEL OF EVIDENCE: Diagnostic Level III.


Assuntos
Fraturas Fechadas , Fraturas Expostas , Humanos , Fraturas Expostas/cirurgia , Fraturas Fechadas/cirurgia , Tomografia Computadorizada por Raios X/métodos , Estudos Retrospectivos , Centros de Traumatologia
14.
Artigo em Inglês | MEDLINE | ID: mdl-37542555

RESUMO

PURPOSE: Rami comminution has been found to be predictive of lateral compression type 1 (LC1) injury instability on examination under anesthesia (EUA) and lateral stress radiographs (LSR). The purpose of this study was to evaluate how rami comminution and subsequent operative vs. nonoperative management impact the late displacement of these injuries. METHODS: Retrospective review of a prospectively collected LC1 database was performed to identify all patients with minimally displaced LC1 injuries (< 1 cm) and follow-up radiographs over a four-year period (n = 125). Groups were separated based on the presence of rami comminution and subsequent management, including rami comminution/operative (n = 49), rami comminution/nonoperative (n = 54), and no comminution/nonoperative (control group, n = 22). The primary outcome was late fracture displacement, analyzed as both a continuous variable and as late displacement ≥ 5 mm. RESULTS: As a continuous variable, late fracture displacement was lower in the comminuted rami/operative group as compared to the comminuted rami/nonoperative group (PD: -3.0 mm, CI: -4.8 to -1.6 mm, p = 0.0002) and statistically non-different from control. Late displacement ≥ 5 mm was significantly more prevalent in the comminuted rami/nonoperative group than in the comminuted rami/operative and no comminution/nonoperative groups (control)(PD: -33.9%, CI: -49.0% to -16.1%, p = 0.0002 and PD: -30.0%, CI: -48.2% to -6.5%, p = 0.02, respectively). CONCLUSION: Late fracture displacement was greatest in the group with rami comminution/nonoperative management. Rami comminution, which has been previously associated with dynamic displacement on EUA and LSR, is also associated with a higher incidence of late displacement when managed nonoperatively. LEVEL OF EVIDENCE: Level III, prognostic retrospective cohort study.

15.
Eur J Orthop Surg Traumatol ; 33(5): 1953-1957, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36048261

RESUMO

PURPOSE: The purpose of this study was to determine the effect of rotation and tilt on the radiographic teardrop distance (TD) on anteroposterior (AP) pelvis radiographs. METHODS: Radiographic examination of a pelvis models was conducted utilizing increasing degrees of beam rotation and tilt on portable C-arm fluoroscopy. The TD, x-plane rotation (symphyseal-mid-sacrum distance (SMS)), and y-plane tilt (sacroiliac joint-symphysis distance (SIS)) were measured by four independent observers. Interobserver reliability was assessed using intraclass correlations. RESULTS: TD was altered by less than 2 mm with up to 7.5° fluoroscopic rotation (SMS: 3 cm) and up to 30° of inlet and 15° of outlet (SIS: ± 3.3 cm). SMS distance effectively corresponded to the degree of rotation present (r = 1.00, CI: 0.97 to 1.00, p < 0.0001) and was strongly correlated to TD (r = -0.95, CI: -0.99 to -0.67, p = 0.001). SIS distance effectively corresponded to the degree of tilt present (r = -0.97, CI: -0.99 to -0.88, p < 0.0001) and was correlated to TD (r = 0.94, CI: 0.75 to 0.99, p = 0.0001). Linear regression models determined that, with every degree of rotation and tilt, TD was altered by 0.4 mm and 0.09 mm, respectively (p = 0.0004, r2 = 0.93 and p < 0.0001, r2 = 0.94, respectively). Interobserver reliability among observers was excellent (0.92). CONCLUSION: The TD has excellent interobserver reliability and is minimally impacted by up to 7.5° of rotation, 30° inlet tilt, and 15° of outlet tilt. Utilization of these thresholds may ensure reliability of TD measurements when assessing pelvis stress radiographs.


Assuntos
Pelve , Sacro , Humanos , Rotação , Reprodutibilidade dos Testes , Radiografia , Pelve/diagnóstico por imagem
16.
Eur J Orthop Surg Traumatol ; 33(7): 3067-3079, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37020158

RESUMO

PURPOSE: The treatment of extraarticular proximal tibial fractures is challenging. As the optimal fixation technique is still debated, the purpose of this study was to compare minimally invasive plate osteosynthesis (MIPO) and intramedullary nail (IMN) fixation. METHODS: A prospective matched comparative study was conducted on patients with displaced extraarticular proximal tibia fractures treated with MIPO (n = 29) versus IMN (n = 30) fixation. Outcomes collected were the Johner-Wruhs grading, range of motion (ROM), union rate, time to union, malunion, coronal and sagittal alignment, and post-operative complications. RESULTS: Union rates were similar between the MIPO and IMN groups (93% vs. 97%, P = 1.0). The IMN group had an earlier time to union (15 vs. 18 weeks, P < 0.001) and superior functional outcomes at one year (effective Johner-Wruhs score: 80% vs. 55%, P = 0.04). There was a significantly higher incidence of anterior knee pain in the IMN group (23% vs. 0%, P = 0.02) and there was a trend for more infections in the MIPO group (21% vs. 13%, P = 0.73). CONCLUSION: IMN fixation of extraarticular proximal tibia fractures was associated with a shorter union time and better functional scores compared to MIPO.


Assuntos
Fixação Intramedular de Fraturas , Fraturas da Tíbia , Humanos , Tíbia/cirurgia , Fixação Intramedular de Fraturas/efeitos adversos , Fixação Intramedular de Fraturas/métodos , Estudos de Coortes , Estudos Prospectivos , Fraturas da Tíbia/cirurgia , Resultado do Tratamento , Consolidação da Fratura , Procedimentos Cirúrgicos Minimamente Invasivos/efeitos adversos , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Fixação Interna de Fraturas/efeitos adversos , Fixação Interna de Fraturas/métodos , Placas Ósseas
17.
Artigo em Inglês | MEDLINE | ID: mdl-37550556

RESUMO

PURPOSE: To describe the construction and use of a percutaneous pelvic fixation model, evaluate its translational validity among fellowship-trained orthopedic trauma surgeons, and investigate the importance of specific criteria for effective competency-based assessment of pelvic fixation techniques. METHODS: Five orthopedic trauma surgeons were asked to place percutaneous wires on a pelvic fixation model, including anterior column (antegrade/retrograde), posterior column (antegrade/retrograde), supra-acetabular, transsacral, and iliosacral. Evaluation criteria included successful wire placement, redirections, cortical breaches, procedure duration, radiation exposure, and quality of fluoroscopic views. Following completion, participants were provided a survey to rate the model. RESULTS: There were no differences between approaches on successful screw placement, wire redirections, or fluoroscopic quality. Antegrade approaches to the anterior and posterior columns took longer (p = 0.008) and used more radiation (p = 0.02). There was also a trend toward more cortical breaches with the antegrade anterior column approach (p = 0.07). Median ratings among surgeons were 4 out of 5 for their overall impression and its accuracy in tactile response, positioning constraints, and fluoroscopic projections. Learning parameters considered most important to the progression of trainees (most to least important) were successful screw placement, corridor breaches, wire redirections, quality of fluoroscopic views, radiation exposure, and procedure duration. CONCLUSION: In being affordable, accessible, and realistic, this percutaneous pelvic fixation model represents an opportunity to advance orthopedic surgery education globally. Future research is needed to validate the findings of this pilot study and to expand upon how trainees should be evaluated within simulations and the operating room to optimize skill progression.

18.
Int Orthop ; 46(5): 1165-1173, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35246719

RESUMO

PURPOSE: To determine the effect of native tibia valga on intramedullary nail (IMN) fixation of tibial shaft fractures. METHODS: Retrospective comparative cohort analysis of 110 consecutive patients with tibial shaft fractures undergoing IMN fixation at an urban level one trauma centre was performed. Medical records and radiographs were reviewed for demographics, tibia centre of rotation of angulation (CORA), nail starting point, incidence of varus malreduction, and nail/canal proportional fit. RESULTS: Tibia valga (CORA of ≥ 3 degrees) was present in 37 (33.6%) patients. The anatomic nail starting point distance (in relation to the lateral tibial spine) was significantly greater in the tibia valga group (12.0 mm vs. 5.0 mm, mean difference: 7.1 mm, 95% CI: 5.8 to 8.3 mm, p < 0.0001). Varus malreduction was more common in the tibia valga group (10.8% vs. 1.4%, proportional difference: 9.4%, 95% CI: - 1.0 to 21.3%, p = 0.04). Varus malreduction in the tibia valga group was associated with a decreased nail width/inner canal width proportion on multivariate analysis (OR = 0.683, 95% CI: 0.468 to 0.995, p = 0.0004). CONCLUSION: Native tibia valga is common, and the use of a standard coronal IMN starting point with poor nail fit can lead to iatrogenic varus malreduction. In patients with tibia valga, maximizing nail fit or utilization of a medial starting point should be considered.


Assuntos
Fixação Intramedular de Fraturas , Fraturas da Tíbia , Pinos Ortopédicos/efeitos adversos , Fixação Intramedular de Fraturas/efeitos adversos , Humanos , Estudos Retrospectivos , Tíbia/diagnóstico por imagem , Tíbia/cirurgia , Fraturas da Tíbia/diagnóstico por imagem , Fraturas da Tíbia/cirurgia
19.
Eur J Orthop Surg Traumatol ; 32(6): 1201-1206, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34417895

RESUMO

PURPOSE: To determine if regional anesthesia had added benefit to general anesthesia, with or without local anesthesia, in controlling post-operative pain in outpatient orthopedic trauma surgery. METHODS: A retrospective review was performed of prospectively gathered data on 71 patients undergoing outpatient orthopedic trauma surgery. All patients received general anesthesia and an addition 52 patients received additional regional anesthesia. Regional vs. no regional anesthesia groups were compared in terms of post-anesthesia care unit (PACU) pain visual analog scores (VAS), PACU length of stay (LOS), opioid use, and pain control at two weeks. RESULTS: The regional anesthesia group not differ in demographics or proportion of patients receiving local anesthesia, but was less likely to be undergoing major procedures (13% vs. 37%, proportional difference (PD) - 23%; 95% confidence interval (CI) - 46% to - 0.4%). There were no detectable differences in PACU opioid requirements (median difference (MD) - 7.5 mg, CI - 8 to 0), PACU LOS (MD - 13 min, CI - 63 to 24), discharge pain VAS (MD 0, CI - 1 to 1), post-discharge pain VAS (MD 0, CI - 1 to 1), opioid refills (PD - 6%, CI - 31% to 18%), or patient-perceived pain control (PD - 24%, CI - 41% to 0%). On multivariate analysis, regional anesthesia was the only variable negatively associated with patient-perceived pain control at two weeks (Odds Ratio 0.15; 95% CI 0.03 to 0.8). CONCLUSIONS: Regional anesthesia did not improve post-operative opioid requirements, PACU LOS, or patient-reported pain in the immediate or short-term post-operative period.


Assuntos
Assistência ao Convalescente , Analgésicos Opioides , Analgésicos Opioides/uso terapêutico , Anestesia Geral/efeitos adversos , Humanos , Dor Pós-Operatória/diagnóstico , Dor Pós-Operatória/tratamento farmacológico , Dor Pós-Operatória/etiologia , Alta do Paciente
20.
Eur J Orthop Surg Traumatol ; 32(2): 371-376, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33783628

RESUMO

Hip and groin pain in patients at-risk for femoral neck stress fracture demand a careful workup including advanced imaging in the setting of normal radiographs. A delay in diagnosis can lead to fracture displacement, which negatively impacts outcomes. Non-displaced tension-sided fractures and displaced fractures warrant operative fixation, while non-displaced compression-side fractures can be managed conservatively. Fixation with a sliding hip screw or cephalomedullary nail is recommended over cannulated screws. In addition, all patients should undergo a metabolic workup to identify correctable parameters. We present a rare case of bilateral compression-sided basicervical femoral neck stress fractures in a non-compliant osteoporotic patient who was treated with cannulated screws. The postoperative course was complicated by bilateral subtrochanteric stress riser fractures requiring revision fixation, which could have been prevented with use of a different implant.


Assuntos
Fraturas do Colo Femoral , Fraturas de Estresse , Parafusos Ósseos/efeitos adversos , Fraturas do Colo Femoral/diagnóstico por imagem , Fraturas do Colo Femoral/etiologia , Fraturas do Colo Femoral/cirurgia , Colo do Fêmur , Fixação Interna de Fraturas/efeitos adversos , Fraturas de Estresse/diagnóstico por imagem , Fraturas de Estresse/etiologia , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA