Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 34
Filtrar
1.
Eur J Nucl Med Mol Imaging ; 51(8): 2320-2331, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38453729

RESUMO

PURPOSE: The recent development and approval of new diagnostic imaging and therapy approaches in the field of theranostics have revolutionised nuclear medicine practice. To ensure the provision of these new imaging and therapy approaches in a safe and high-quality manner, training of nuclear medicine physicians and qualified specialists is paramount. This is required for trainees who are learning theranostics practice, and for ensuring minimum standards for knowledge and competency in existing practising specialists. METHODS: To address the need for a training curriculum in theranostics that would be utilised at a global level, a Consultancy Meeting was held at the IAEA in May 2023, with participation by experts in radiopharmaceutical therapy and theranostics including representatives of major international organisations relevant to theranostics practice. RESULTS: Through extensive discussions and review of existing curriculum and guidelines, a harmonised training program for theranostics was developed, which aims to ensure safe and high quality theranostics practice in all countries. CONCLUSION: The guiding principles for theranostics training outlined in this paper have immediate relevance for the safe and effective practice of theranostics.


Assuntos
Medicina Nuclear , Humanos , Medicina Nuclear/educação , Nanomedicina Teranóstica , Currículo
2.
Heart Lung Circ ; 33(3): 384-391, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38365497

RESUMO

AIM: The aim of this study was to assess the recovery rates of diagnostic cardiac procedure volumes in the Oceania Region, midway through the coronavirus disease 2019 (COVID-19) pandemic. METHODS: A survey was performed comparing procedure volumes between March 2019 (pre-pandemic), April 2020 (during first wave of COVID-19 pandemic), and April 2021 (1 year into the COVID-19 pandemic). A total of 31 health care facilities within Oceania that perform cardiac diagnostic procedures were surveyed, including a mixture of metropolitan and regional, hospital and outpatient, public and private sites, as well as teaching and non-teaching hospitals. A comparison was made with 549 centres in 96 countries in the rest of the world (RoW) outside of Oceania. The total number and median percentage change in procedure volume were measured between the three timepoints, compared by test type and by facility. RESULTS: A total of 11,902 cardiac diagnostic procedures were performed in Oceania in April 2021 as compared with 11,835 pre-pandemic in March 2019 and 5,986 in April 2020; whereas, in the RoW, 499,079 procedures were performed in April 2021 compared with 497,615 pre-pandemic in March 2019 and 179,014 in April 2020. There was no significant difference in the median recovery rates for total procedure volumes between Oceania (-6%) and the RoW (-3%) (p=0.81). While there was no statistically significant difference in percentage recovery been functional ischaemia testing and anatomical coronary testing in Oceania as compared with the RoW, there was, however, a suggestion of poorer recovery in anatomical coronary testing in Oceania as compared with the RoW (CT coronary angiography -16% in Oceania vs -1% in RoW, and invasive coronary angiography -20% in Oceania vs -9% in RoW). There was no statistically significant difference in recovery rates in procedure volume between metropolitan vs regional (p=0.44), public vs private (p=0.92), hospital vs outpatient (p=0.79), or teaching vs non-teaching centres (p=0.73). CONCLUSIONS: Total cardiology procedure volumes in Oceania normalised 1 year post-pandemic compared to pre-pandemic levels, with no significant difference compared with the RoW and between the different types of health care facilities.


Assuntos
COVID-19 , Cardiologia , Humanos , COVID-19/epidemiologia , Pandemias , Inquéritos e Questionários , Angiografia Coronária , Teste para COVID-19
3.
Heart Lung Circ ; 30(10): 1477-1486, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34053885

RESUMO

OBJECTIVES: The INCAPS COVID Oceania study aimed to assess the impact caused by the COVID-19 pandemic on cardiac procedure volume provided in the Oceania region. METHODS: A retrospective survey was performed comparing procedure volumes within March 2019 (pre-COVID-19) with April 2020 (during first wave of COVID-19 pandemic). Sixty-three (63) health care facilities within Oceania that perform cardiac diagnostic procedures were surveyed, including a mixture of metropolitan and regional, hospital and outpatient, public and private sites, and 846 facilities outside of Oceania. The percentage change in procedure volume was measured between March 2019 and April 2020, compared by test type and by facility. RESULTS: In Oceania, the total cardiac diagnostic procedure volume was reduced by 52.2% from March 2019 to April 2020, compared to a reduction of 75.9% seen in the rest of the world (p<0.001). Within Oceania sites, this reduction varied significantly between procedure types, but not between types of health care facility. All procedure types (other than stress cardiac magnetic resonance [CMR] and positron emission tomography [PET]) saw significant reductions in volume over this time period (p<0.001). In Oceania, transthoracic echocardiography (TTE) decreased by 51.6%, transoesophageal echocardiography (TOE) by 74.0%, and stress tests by 65% overall, which was more pronounced for stress electrocardiograph (ECG) (81.8%) and stress echocardiography (76.7%) compared to stress single-photon emission computerised tomography (SPECT) (44.3%). Invasive coronary angiography decreased by 36.7% in Oceania. CONCLUSION: A significant reduction in cardiac diagnostic procedure volume was seen across all facility types in Oceania and was likely a function of recommendations from cardiac societies and directives from government to minimise spread of COVID-19 amongst patients and staff. Longer term evaluation is important to assess for negative patient outcomes which may relate to deferral of usual models of care within cardiology.


Assuntos
COVID-19 , Cardiologia , Humanos , Pandemias , Estudos Retrospectivos , SARS-CoV-2 , Tomografia Computadorizada por Raios X
4.
Eur Respir J ; 55(2)2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31831584

RESUMO

BACKGROUND: A large proportion of the huge global burden of extrapulmonary tuberculosis (EPTB) cases are treated empirically without accurate definition of disease sites and extent of multi-organ disease involvement. Positron emission tomography (PET) imaging using 2-deoxy-2-(fluorine-18) fluoro-d-glucose (18F-FDG) in tuberculosis could be a useful imaging technique for localising disease sites and extent of disease. METHODS: We conducted a study of HIV-negative adult patients with a new clinical diagnosis of EPTB across eight centres located in six countries: India, Pakistan, Thailand, South Africa, Serbia and Bangladesh, to assess the extent of disease and common sites involved at first presentation. 18F-FDG PET/computed tomography (CT) scans were performed within 2 weeks of presentation. FINDINGS: 358 patients with EPTB (189 females; 169 males) were recruited over 45 months, with an age range of 18-83 years (females median 30 years; males median 38 years). 350 (98%) out of 358 patients (183 female, 167 male) had positive scans. 118 (33.7%) out of 350 had a single extrapulmonary site and 232 (66.3%) out of 350 had more than one site (organ) affected. Lymph nodes, skeleton, pleura and brain were common sites. 100 (28%) out of 358 EPTB patients had 18F-FDG PET/CT-positive sites in the lung. 110 patients were 18F-FDG PET/CT-positive in more body sites than were noted clinically at first presentation and 160 patients had the same number of positive body sites. INTERPRETATION: 18F-FDG PET/CT scan has potential for further elucidating the spectrum of disease, pathogenesis of EPTB and monitoring the effects of treatment on active lesions over time, and requires longitudinal cohort studies, twinned with biopsy and molecular studies.


Assuntos
Fluordesoxiglucose F18 , Tuberculose , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Bangladesh , Estudos Transversais , Feminino , Humanos , Índia , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Paquistão , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Tomografia por Emissão de Pósitrons , Compostos Radiofarmacêuticos , África do Sul , Tuberculose/diagnóstico por imagem , Adulto Jovem
5.
Eur J Nucl Med Mol Imaging ; 47(13): 3118-3129, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32483653

RESUMO

BACKGROUND: Initial studies of tuberculosis (TB) in macaques and humans using 18F-FDG positron emission tomography (PET) imaging as a research tool suggest its usefulness in localising disease sites and as a clinical biomarker. Sequential serial scans in patients with extrapulmonary TB (EPTB) could inform on the value of PET-CT for monitoring response to treatment and defining cure. PATIENTS AND METHODS: HIV-negative adults with EPTB from eight sites across six countries had three 18F-FDG PET/CT scans: (i) within 2 weeks of enrolment, (ii) at 2 months into TB treatment and (iii) at end of ATT treatment. Scanning was performed according to the EANM guidelines. 18F-FDG PET/CT scans were performed 60 ± 10 min after intravenous injection of 2.5-5.0 MBq/kg of 18F-FDG. FINDINGS: One hundred and forty-seven patients with EPTB underwent 3 sequential scans. A progressive reduction over time of both the number of active sites and the uptake level (SUVmax) at these sites was seen. At the end of WHO recommended treatment, 53/147 (36.0%) patients had negative PET/CT scans, and 94/147 (63.9%) patients remained PET/CT positive, of which 12 patients had developed MDR TB. One died of brain tuberculoma. INTERPRETATION: Current 18F-FDG PET/CT imaging technology cannot be used clinically as a biomarker of treatment response, cure or for decision-making on when to stop EPTB treatment. PET/CT remains a research tool for TB and further development of PET/CT is required using new Mycobacterium tuberculosis-specific radiopharmaceuticals targeting high-density surface epitopes, gene targets or metabolic pathways.


Assuntos
Fluordesoxiglucose F18 , Tuberculose , Adulto , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Tomografia por Emissão de Pósitrons , Compostos Radiofarmacêuticos , Tuberculose/diagnóstico por imagem
6.
J Nucl Cardiol ; 27(2): 465-478, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-30168029

RESUMO

BACKGROUND: Consistency of results between different readers is an important issue in medical imaging, as it affects portability of results between institutions and may affect patient care. The International Atomic Energy Agency (IAEA) in pursuing its mission of fostering peaceful applications of nuclear technologies has supported several training activities in the field of nuclear cardiology (NC) and SPECT myocardial perfusion imaging (MPI) in particular. The aim of this study was to verify the outcome of those activities through an international clinical audit on MPI where participants were requested to report on studies distributed from a core lab. METHODS: The study was run in two phases: in phase 1, SPECT MPI studies were distributed as raw data and full processing was requested as per local practice. In phase 2, images from studies pre-processed at the core lab were distributed. Data to be reported included summed stress score (SSS); summed rest score (SRS); summed difference score (SDS); left ventricular (LV) ejection fraction (EF) and end- diastolic volume (EDV). Qualitative appraisals included the assessment of perfusion and presence of ischemia, scar or mixed patterns, presence of transient ischemic dilation (TID), and risk for cardiac events (CE). Twenty-four previous trainees from low- and middle-income countries participated (core participants group) and their results were assessed for inter-observer variability in each of the two phases, and for changes between phases. The same evaluations were performed for a group of eleven international experts (experts group). Results were also compared between the groups. RESULTS: Expert readers showed an excellent level of agreement for all parameters in both phase 1 and 2. For core participants, the concordance of all parameters in phase 1 was rated as good to excellent. Two parameters which were re-evaluated in phase 2, namely SSS and SRS, showed an increased level of concordance, up to excellent in both cases. Reporting of categorical variables by expert readers remained almost unchanged between the two phases, while core participants showed an increase in phase 2. Finally, pooled LVEF values did not show a significant difference between core participants and experts. However, significant differences were found between LVEF values obtained using different software packages for cardiac analysis. CONCLUSIONS: In this study, inter-observer agreement was moderate-to-good for core group readers and good-to-excellent for expert readers. The quality of reporting is affected by the quality of processing. These results confirm the important role of the IAEA training activities in improving imaging in low- and middle-income countries.


Assuntos
Imagem de Perfusão do Miocárdio/métodos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Idoso , Tomografia Computadorizada por Emissão de Fóton Único de Sincronização Cardíaca , Países em Desenvolvimento , Teste de Esforço , Feminino , Geografia , Coração , Ventrículos do Coração , Humanos , Cooperação Internacional , Masculino , Pessoa de Meia-Idade , Imagem de Perfusão do Miocárdio/normas , Variações Dependentes do Observador , Tomografia por Emissão de Pósitrons/métodos , Pobreza , Risco , Volume Sistólico , Tecnécio , Tomografia Computadorizada de Emissão de Fóton Único/normas , Disfunção Ventricular Esquerda/fisiopatologia , Função Ventricular Esquerda
7.
J Nucl Cardiol ; 24(3): 851-859, 2017 06.
Artigo em Inglês | MEDLINE | ID: mdl-26902484

RESUMO

BACKGROUND: Comparison of Latin American (LA) nuclear cardiology (NC) practice with that in the rest of the world (RoW) will identify areas for improvement and lead to educational activities to reduce radiation exposure from NC. METHODS AND RESULTS: INCAPS collected data on all SPECT and PET procedures performed during a single week in March-April 2013 in 36 laboratories in 10 LA countries (n = 1139), and 272 laboratories in 55 countries in RoW (n = 6772). Eight "best practices" were identified a priori and a radiation-related Quality Index (QI) was devised indicating the number used. Mean radiation effective dose (ED) in LA was higher than in RoW (11.8 vs 9.1 mSv, p < 0.001). Within a populous country like Brazil, a wide variation in laboratory mean ED was found, ranging from 8.4 to 17.8 mSv. Only 11% of LA laboratories achieved median ED <9 mSv, compared to 32% in RoW (p < 0.001). QIs ranged from 2 in a laboratory in Mexico to 7 in a laboratory in Cuba. Three major opportunities to reduce ED for LA patients were identified: (1) more laboratories could implement stress-only imaging, (2) camera-based methods of ED reduction, including prone imaging, could be more frequently used, and (3) injected activity of 99mTc could be adjusted reflecting patient weight/habitus. CONCLUSIONS: On average, radiation dose from NC is higher in LA compared to RoW, with median laboratory ED <9 mSv achieved only one third as frequently as in RoW. Opportunities to reduce radiation exposure in LA have been identified and guideline-based recommendations made to optimize protocols and adhere to the "as low as reasonably achievable" (ALARA) principle.


Assuntos
Cardiologia/normas , Imagem de Perfusão do Miocárdio/estatística & dados numéricos , Padrões de Prática Médica/estatística & dados numéricos , Garantia da Qualidade dos Cuidados de Saúde/estatística & dados numéricos , Exposição à Radiação/prevenção & controle , Proteção Radiológica/estatística & dados numéricos , Tomografia Computadorizada de Emissão/estatística & dados numéricos , Cardiologia/estatística & dados numéricos , Fidelidade a Diretrizes/normas , Fidelidade a Diretrizes/estatística & dados numéricos , Pesquisas sobre Atenção à Saúde , Humanos , Internacionalidade , América Latina/epidemiologia , Pessoa de Meia-Idade , Imagem de Perfusão do Miocárdio/normas , Padrões de Prática Médica/normas , Melhoria de Qualidade , Proteção Radiológica/normas , Tomografia Computadorizada de Emissão/normas , Revisão da Utilização de Recursos de Saúde
8.
Circ J ; 81(4): 501-510, 2017 Mar 24.
Artigo em Inglês | MEDLINE | ID: mdl-28179594

RESUMO

BACKGROUND: This paper examines the current status of radiation exposure to patients in myocardial perfusion imaging (MPI) in Asia.Methods and Results:Laboratories voluntarily provided information on MPI performed over a 1-week period. Eight best practice criteria regarding MPI were predefined by an expert panel. Implementation of ≥6 best practices (quality index [QI] ≥6) was pre-specified as a desirable goal for keeping radiation exposure at a low level. Radiation effective dose (ED) in 1,469 patients and QI of 69 laboratories in Asia were compared against data from 239 laboratories in the rest of the world (RoW). Mean ED was significantly higher in Asia (11.4 vs. 9.6 mSv; P<0.0001), with significantly lower doses in South-East vs. East Asia (9.7 vs. 12.7 mSv; P<0.0001). QI in Asia was lower than in RoW. In comparison with RoW, Asian laboratories used thallium more frequently, used weight-based technetium dosing less frequently, and trended towards a lower rate of stress-only imaging. CONCLUSIONS: MPI radiation dose in Asia is higher than that in the RoW and linked to less consistent use of laboratory best practices such as avoidance of thallium, weight-based dosing, and use of stress-only imaging. Given that MPI is performed in Asia within a diverse array of medical contexts, laboratory-specific adoption of best practices offers numerous opportunities to improve quality of care.


Assuntos
Imagem de Perfusão do Miocárdio/efeitos adversos , Padrões de Prática Médica/normas , Exposição à Radiação/estatística & dados numéricos , Idoso , Ásia , Cardiologia/métodos , Estudos Transversais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Medicina Nuclear/métodos , Qualidade da Assistência à Saúde , Doses de Radiação , Tecnécio/administração & dosagem , Tálio/administração & dosagem
9.
Heart Lung Circ ; 26(1): 25-34, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27425184

RESUMO

BACKGROUND: There is concern about radiation exposure with radionuclide myocardial perfusion imaging (MPI). This sub-study of the International Atomic Energy Agency (IAEA) Nuclear Cardiology Protocols Study reports radiation doses from MPI, and use of dose-optimisation protocols in Australia and New Zealand (ANZ), and compares them with data from the rest of the world. METHODS: Data were collected from 7911 MPI studies performed in 308 laboratories worldwide in one week in 2013, including 439 MPI studies from 34 ANZ laboratories. For each laboratory, effective radiation dose (ED) and a quality index (QI) score (out of 8) based on pre-specified "best practices" was determined. RESULTS: In ANZ patients, ED ranged from 0.9-17.9 milliSievert (mSv). Median ED was similar in ANZ compared with the rest of the world (10.0 (IQR: 6.5-11.7) vs. 10.0 (IQR 6.4-12.6, P=0.15), as were mean QI scores (5.5±0.7 vs. 5.4±1.3, P=0.84). Use of stress-only imaging (17.6% vs. 31.8% of labs, P=0.09) and weight-based dosing of technetium-99m (14.7% vs. 30.3%, P=0.07) was lower in ANZ compared with the rest of the world but this difference was not statistically significant. Median ED was significantly lower in metropolitan versus non-metropolitan laboratories (10.1 mSv vs. 11.6 mSv, P<0.01), although mean QI scores were similar (5.4±0.8 vs. 5.5±0.7, P=0.75). CONCLUSION: Across ANZ, there is variability in ED from MPI, and use of radiation safety practices, particularly between metropolitan and non-metropolitan laboratories. Overall, ANZ laboratories have a similar median ED to laboratories in the rest of the world.


Assuntos
Imagem de Perfusão do Miocárdio/efeitos adversos , Doses de Radiação , Exposição à Radiação , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Oceania
10.
Eur J Nucl Med Mol Imaging ; 43(4): 718-28, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26686336

RESUMO

PURPOSE: Nuclear cardiology is widely used to diagnose coronary artery disease and to guide patient management, but data on current practices, radiation dose-related best practices, and radiation doses are scarce. To address these issues, the IAEA conducted a worldwide study of nuclear cardiology practice. We present the European subanalysis. METHODS: In March 2013, the IAEA invited laboratories across the world to document all SPECT and PET studies performed in one week. The data included age, gender, weight, radiopharmaceuticals, injected activities, camera type, positioning, hardware and software. Radiation effective dose was calculated for each patient. A quality score was defined for each laboratory as the number followed of eight predefined best practices with a bearing on radiation exposure (range of quality score 0 - 8). The participating European countries were assigned to regions (North, East, South, and West). Comparisons were performed between the four European regions and between Europe and the rest-of-the-world (RoW). RESULTS: Data on 2,381 European patients undergoing nuclear cardiology procedures in 102 laboratories in 27 countries were collected. A cardiac SPECT study was performed in 97.9 % of the patients, and a PET study in 2.1 %. The average effective dose of SPECT was 8.0 ± 3.4 mSv (RoW 11.4 ± 4.3 mSv; P < 0.001) and of PET was 2.6 ± 1.5 mSv (RoW 3.8 ± 2.5 mSv; P < 0.001). The mean effective doses of SPECT and PET differed between European regions (P < 0.001 and P = 0.002, respectively). The mean quality score was 6.2 ± 1.2, which was higher than the RoW score (5.0 ± 1.1; P < 0.001). Adherence to best practices did not differ significantly among the European regions (range 6 to 6.4; P = 0.73). Of the best practices, stress-only imaging and weight-adjusted dosing were the least commonly used. CONCLUSION: In Europe, the mean effective dose from nuclear cardiology is lower and the average quality score is higher than in the RoW. There is regional variation in effective dose in relation to the best practice quality score. A possible reason for the differences between Europe and the RoW could be the safety culture fostered by actions under the Euratom directives and the implementation of diagnostic reference levels. Stress-only imaging and weight-adjusted activity might be targets for optimization of European nuclear cardiology practice.


Assuntos
Técnicas de Imagem Cardíaca/métodos , Tomografia por Emissão de Pósitrons/métodos , Guias de Prática Clínica como Assunto , Doses de Radiação , Técnicas de Imagem Cardíaca/efeitos adversos , Técnicas de Imagem Cardíaca/instrumentação , Técnicas de Imagem Cardíaca/normas , Cardiologia/organização & administração , União Europeia , Medicina Nuclear/organização & administração , Tomografia por Emissão de Pósitrons/efeitos adversos , Tomografia por Emissão de Pósitrons/instrumentação , Tomografia por Emissão de Pósitrons/normas , Sociedades Científicas
11.
Eur Heart J ; 36(26): 1689-96, 2015 Jul 07.
Artigo em Inglês | MEDLINE | ID: mdl-25898845

RESUMO

AIMS: To characterize patient radiation doses from nuclear myocardial perfusion imaging (MPI) and the use of radiation-optimizing 'best practices' worldwide, and to evaluate the relationship between laboratory use of best practices and patient radiation dose. METHODS AND RESULTS: We conducted an observational cross-sectional study of protocols used for all 7911 MPI studies performed in 308 nuclear cardiology laboratories in 65 countries for a single week in March-April 2013. Eight 'best practices' relating to radiation exposure were identified a priori by an expert committee, and a radiation-related quality index (QI) devised indicating the number of best practices used by a laboratory. Patient radiation effective dose (ED) ranged between 0.8 and 35.6 mSv (median 10.0 mSv). Average laboratory ED ranged from 2.2 to 24.4 mSv (median 10.4 mSv); only 91 (30%) laboratories achieved the median ED ≤ 9 mSv recommended by guidelines. Laboratory QIs ranged from 2 to 8 (median 5). Both ED and QI differed significantly between laboratories, countries, and world regions. The lowest median ED (8.0 mSv), in Europe, coincided with high best-practice adherence (mean laboratory QI 6.2). The highest doses (median 12.1 mSv) and low QI (4.9) occurred in Latin America. In hierarchical regression modelling, patients undergoing MPI at laboratories following more 'best practices' had lower EDs. CONCLUSION: Marked worldwide variation exists in radiation safety practices pertaining to MPI, with targeted EDs currently achieved in a minority of laboratories. The significant relationship between best-practice implementation and lower doses indicates numerous opportunities to reduce radiation exposure from MPI globally.


Assuntos
Fidelidade a Diretrizes/normas , Imagem de Perfusão do Miocárdio/estatística & dados numéricos , Guias de Prática Clínica como Assunto/normas , Doses de Radiação , Exposição à Radiação/análise , Idoso , Cardiologia/normas , Protocolos Clínicos/normas , Estudos Transversais , Feminino , Saúde Global , Humanos , Masculino , Pessoa de Meia-Idade , Imagem de Perfusão do Miocárdio/normas , Tomografia por Emissão de Pósitrons/normas , Tomografia por Emissão de Pósitrons/estatística & dados numéricos , Prática Profissional/normas , Prática Profissional/estatística & dados numéricos , Qualidade da Assistência à Saúde/normas , Qualidade da Assistência à Saúde/estatística & dados numéricos , Análise de Regressão , Tomografia Computadorizada de Emissão de Fóton Único/normas , Tomografia Computadorizada de Emissão de Fóton Único/estatística & dados numéricos
12.
Am J Cardiol ; 214: 85-93, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38218393

RESUMO

The COVID-19 pandemic disrupted the delivery of cardiovascular care, including noninvasive testing protocols and test selection for the evaluation of coronary artery disease (CAD). Trends in test selection in traditional versus advanced noninvasive tests for CAD during the pandemic and in countries of varying income status have not been well studied. The International Atomic Energy Agency conducted a global survey to assess the pandemic-related changes in the practice of cardiovascular diagnostic testing. Site procedural volumes for noninvasive tests to evaluate CAD from March 2019 (prepandemic), April 2020 (onset), and April 2021 (initial recovery) were collected. We considered traditional testing modalities, such as exercise electrocardiography, stress echocardiography, and stress single-photon emission computed tomography, and advanced testing modalities, such as stress cardiac magnetic resonance, coronary computed tomography angiography, and stress positron emission tomography. Survey data were obtained from 669 centers in 107 countries, reporting the performance of 367,933 studies for CAD during the study period. Compared with 2019, traditional tests were performed 14% less frequently (recovery rate 82%) in 2021 versus advanced tests, which were performed 15% more frequently (128% recovery rate). Coronary computed tomography angiography, stress cardiac magnetic resonance, and stress positron emission tomography showed 14%, 25%, and 25% increases in volumes from 2019 to 2021, respectively. The increase in advanced testing was isolated to high- and upper middle-income countries, with 132% recovery in advanced tests by 2021 compared with 55% in lower income nations. The COVID-19 pandemic exacerbated economic disparities in CAD testing practice between wealthy and poorer countries. Greater recovery rates and even new growth were observed for advanced imaging modalities; however, this growth was restricted to wealthy countries. Efforts to reduce practice variations in CAD testing because of economic status are warranted.


Assuntos
COVID-19 , Doença da Artéria Coronariana , Humanos , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/epidemiologia , Angiografia Coronária/métodos , Pandemias , COVID-19/epidemiologia , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Teste de Esforço
13.
Int J Cardiol Heart Vasc ; 52: 101404, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38590383

RESUMO

Background: The COVID-19 pandemic disproportionately impacted Latin America (LATAM), significantly disrupting cardiovascular testing. This study evaluated cardiac procedure recovery in LATAM one year after the outbreak. Methods: The International Atomic Energy Agency (IAEA) surveyed 669 centers in 107 countries worldwide, including 135 facilities in 19 LATAM countries, to assess cardiovascular procedure volumes in March 2019, April 2020, and April 2021, and changes in center practices and staffing conditions one year into the COVID-19 pandemic. Findings: LATAM centers reported a 21 % decrease in procedure volumes in April 2021 from pre-pandemic-baseline, vs. a 0 % change in the rest of the world (RoW), and greater volume reductions for almost all procedure types. Centers in Central America and Mexico reported the largest procedure reductions (47 % reduction) compared to the Caribbean (15 %), and South America (14 %, p = 0.01), and this LATAM region was a significant predictor of lower procedure recovery in multivariable regression. More LATAM centers reported reduced salaries and increased layoffs of clinical staff compared to RoW, and LATAM respondents estimated that half of physician and non-physician staff experienced excess psychological stress related to the pandemic, compared to 25 % and 30 % in RoW (p < 0.001). Conclusions: Cardiovascular testing recovery in LATAM trailed behind RoW for most procedure types, with centers in Central America and Mexico reporting the greatest volume reductions. This study found lasting impacts of COVID-19 on cardiovascular care in LATAM and the need for mental health support for LATAM healthcare workers in current and future pandemics.

14.
Radiol Cardiothorac Imaging ; 5(5): e220288, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37908554

RESUMO

Purpose: To characterize the recovery of diagnostic cardiovascular procedure volumes in U.S. and non-U.S. facilities in the year following the initial COVID-19 outbreak. Materials and Methods: The International Atomic Energy Agency (IAEA) coordinated a worldwide study called the IAEA Noninvasive Cardiology Protocols Study of COVID-19 2 (INCAPS COVID 2), collecting data from 669 facilities in 107 countries, including 93 facilities in 34 U.S. states, to determine the impact of the pandemic on diagnostic cardiovascular procedure volumes. Participants reported volumes for each diagnostic imaging modality used at their facility for March 2019 (baseline), April 2020, and April 2021. This secondary analysis of INCAPS COVID 2 evaluated differences in changes in procedure volume between U.S. and non-U.S. facilities and among U.S. regions. Factors associated with return to prepandemic volumes in the United States were also analyzed in a multivariable regression analysis. Results: Reduction in procedure volumes in April 2020 compared with baseline was similar for U.S. and non-U.S. facilities (-66% vs -71%, P = .27). U.S. facilities reported greater return to baseline in April 2021 than did all non-U.S. facilities (4% vs -6%, P = .008), but there was no evidence of a difference when comparing U.S. facilities with non-U.S. high-income country (NUHIC) facilities (4% vs 0%, P = .18). U.S. regional differences in return to baseline were observed between the Midwest (11%), Northeast (9%), South (1%), and West (-7%, P = .03), but no studied factors were significant predictors of 2021 change from prepandemic baseline. Conclusion: The reductions in cardiac testing during the early pandemic have recovered within a year to prepandemic baselines in the United States and NUHICs, while procedure volumes remain depressed in lower-income countries.Keywords: SPECT, Cardiac, Epidemiology, Angiography, CT Angiography, CT, Echocardiography, SPECT/CT, MR Imaging, Radionuclide Studies, COVID-19, Cardiovascular Imaging, Diagnostic Cardiovascular Procedure, Cardiovascular Disease, Cardiac Testing Supplemental material is available for this article. © RSNA, 2023.

15.
J Am Coll Cardiol ; 79(20): 2001-2017, 2022 05 24.
Artigo em Inglês | MEDLINE | ID: mdl-35589162

RESUMO

BACKGROUND: The extent to which health care systems have adapted to the COVID-19 pandemic to provide necessary cardiac diagnostic services is unknown. OBJECTIVES: The aim of this study was to determine the impact of the pandemic on cardiac testing practices, volumes and types of diagnostic services, and perceived psychological stress to health care providers worldwide. METHODS: The International Atomic Energy Agency conducted a worldwide survey assessing alterations from baseline in cardiovascular diagnostic care at the pandemic's onset and 1 year later. Multivariable regression was used to determine factors associated with procedure volume recovery. RESULTS: Surveys were submitted from 669 centers in 107 countries. Worldwide reduction in cardiac procedure volumes of 64% from March 2019 to April 2020 recovered by April 2021 in high- and upper middle-income countries (recovery rates of 108% and 99%) but remained depressed in lower middle- and low-income countries (46% and 30% recovery). Although stress testing was used 12% less frequently in 2021 than in 2019, coronary computed tomographic angiography was used 14% more, a trend also seen for other advanced cardiac imaging modalities (positron emission tomography and magnetic resonance; 22%-25% increases). Pandemic-related psychological stress was estimated to have affected nearly 40% of staff, impacting patient care at 78% of sites. In multivariable regression, only lower-income status and physicians' psychological stress were significant in predicting recovery of cardiac testing. CONCLUSIONS: Cardiac diagnostic testing has yet to recover to prepandemic levels in lower-income countries. Worldwide, the decrease in standard stress testing is offset by greater use of advanced cardiac imaging modalities. Pandemic-related psychological stress among providers is widespread and associated with poor recovery of cardiac testing.


Assuntos
COVID-19 , COVID-19/epidemiologia , Atenção à Saúde , Pessoal de Saúde , Humanos , Pandemias , Inquéritos e Questionários
16.
Arq Bras Cardiol ; 118(4): 745-753, 2022 04.
Artigo em Inglês, Português | MEDLINE | ID: mdl-35137793

RESUMO

BACKGROUND: The COVID-19 pandemic has disrupted the delivery of care for cardiovascular diseases in Latin America. However, the effect of the pandemic on the cardiac diagnostic procedure volumes has not been quantified. OBJECTIVE: To assess (1) the impact of COVID-19 on cardiac diagnostic volumes in Latin America and (2) determine its relationship with COVID-19 case incidence and social distancing measures. METHODS: The International Atomic Energy Agency conducted a worldwide survey assessing changes in cardiac diagnostic volumes resulting from COVID-19. Cardiac diagnostic volumes were obtained from participating sites for March and April 2020 and compared to March 2019. Social distancing data were collected from Google COVID-19 community mobility reports and COVID-19 incidence per country from the Our World in Data. RESULTS: Surveys were conducted in 194 centers performing cardiac diagnostic procedures, in 19 countries in Latin America. Procedure volumes decreased 36% from March 2019 to March 2020, and 82% from March 2019 to April 2020. The greatest decreases occurred in echocardiogram stress tests (91%), exercise treadmill tests (88%), and computed tomography calcium scores (87%), with slight variations between sub-regions of Latin America. Changes in social distancing patterns (p < 0.001) were more strongly associated with volume reduction than COVID-19 incidence (p = 0.003). CONCLUSIONS: COVID-19 was associated with a significant reduction in cardiac diagnostic procedures in Latin America, which was more related to social distancing than to the COVID-19 incidence. Better balance and timing of social distancing measures and planning to maintain access to medical care is warranted during a pandemic surge, especially in regions with high cardiovascular mortality.


FUNDAMENTO: A pandemia de COVID-19 interferiu na prestação de atendimento a doenças cardiovasculares na América Latina. No entanto, o efeito da pandemia nos volumes de procedimentos cardíacos diagnósticos ainda não foi quantificado. OBJETIVO: Avaliar (1) o impacto de COVID-19 nos volumes de diagnóstico cardíaco na América Latina e (2) determinar sua relação com a incidência de casos de COVID-19 e as medidas de distanciamento social. MÉTODOS: A International Atomic Energy Agency realizou uma pesquisa mundial avaliando mudanças nos volumes diagnósticos cardíacos decorrentes da COVID-19. Foram obtidos os volumes diagnósticos cardíacos dos locais participantes para março e abril de 2020 e comparados com março de 2019. Foram coletados dados de distanciamento social a partir dos Relatórios de mobilidade da comunidade de Google e a incidência de COVID-19 por país a partir de Our World in Data. RESULTADOS: Foram realizadas pesquisas em 194 centros que realizam procedimentos diagnósticos cardíacos, em 19 países da América Latina. Em comparação com o mês de março de 2019, os volumes dos procedimentos diagnósticos cardíacos diminuíram 36% em março de 2020 e 82% em abril de 2020.As maiores reduções ocorreram em relação aos testes de estresse ecocardiográfico (91%), testes ergométricos de esteira (88%) e escore de cálcio por tomografia computadorizada (87%), com pequenas variações entre as sub-regiões da América Latina. As mudanças em padrões de distanciamento social (p < 0,001) estavam mais fortemente associadas com a redução do volume do que a incidência de COVID-19 (p = 0,003). CONCLUSÕES: A COVID-19 foi associada a uma redução significativa de procedimentos diagnósticos cardíacos na América Latina, a qual foi mais relacionada ao distanciamento social do que ao aumento da incidência da COVID-19. São necessários melhor equilíbrio e timing de medidas de distanciamento social e planejamento para manter o acesso ao atendimento médico durante um surto pandêmico, especialmente em regiões com alta mortalidade cardiovascular.


Assuntos
COVID-19 , Cardiopatias , COVID-19/diagnóstico , COVID-19/epidemiologia , Cardiopatias/epidemiologia , Humanos , América Latina/epidemiologia , Pandemias , Inquéritos e Questionários
17.
Int J Cardiol ; 341: 100-106, 2021 10 15.
Artigo em Inglês | MEDLINE | ID: mdl-34478789

RESUMO

BACKGROUND: In early 2020, COVID-19 massively hit Italy, earlier and harder than any other European country. This caused a series of strict containment measures, aimed at blocking the spread of the pandemic. Healthcare delivery was also affected when resources were diverted towards care of COVID-19 patients, including intensive care wards. AIM OF THE STUDY: The aim is assessing the impact of COVID-19 on cardiac imaging in Italy, compare to the Rest of Europe (RoE) and the World (RoW). METHODS: A global survey was conducted in May-June 2020 worldwide, through a questionnaire distributed online. The survey covered three periods: March and April 2020, and March 2019. Data from 52 Italian centres, a subset of the 909 participating centres from 108 countries, were analyzed. RESULTS: In Italy, volumes decreased by 67% in March 2020, compared to March 2019, as opposed to a significantly lower decrease (p < 0.001) in RoE and RoW (41% and 40%, respectively). A further decrease from March 2020 to April 2020 summed up to 76% for the North, 77% for the Centre and 86% for the South. When compared to the RoE and RoW, this further decrease from March 2020 to April 2020 in Italy was significantly less (p = 0.005), most likely reflecting the earlier effects of the containment measures in Italy, taken earlier than anywhere else in the West. CONCLUSIONS: The COVID-19 pandemic massively hit Italy and caused a disruption of healthcare services, including cardiac imaging studies. This raises concern about the medium- and long-term consequences for the high number of patients who were denied timely diagnoses and the subsequent lifesaving therapies and procedures.


Assuntos
COVID-19 , Cardiologia , Humanos , Itália/epidemiologia , Pandemias , SARS-CoV-2 , Inquéritos e Questionários
18.
J Am Coll Cardiol ; 77(2): 173-185, 2021 01 19.
Artigo em Inglês | MEDLINE | ID: mdl-33446311

RESUMO

BACKGROUND: The coronavirus disease 2019 (COVID-19) pandemic has adversely affected diagnosis and treatment of noncommunicable diseases. Its effects on delivery of diagnostic care for cardiovascular disease, which remains the leading cause of death worldwide, have not been quantified. OBJECTIVES: The study sought to assess COVID-19's impact on global cardiovascular diagnostic procedural volumes and safety practices. METHODS: The International Atomic Energy Agency conducted a worldwide survey assessing alterations in cardiovascular procedure volumes and safety practices resulting from COVID-19. Noninvasive and invasive cardiac testing volumes were obtained from participating sites for March and April 2020 and compared with those from March 2019. Availability of personal protective equipment and pandemic-related testing practice changes were ascertained. RESULTS: Surveys were submitted from 909 inpatient and outpatient centers performing cardiac diagnostic procedures, in 108 countries. Procedure volumes decreased 42% from March 2019 to March 2020, and 64% from March 2019 to April 2020. Transthoracic echocardiography decreased by 59%, transesophageal echocardiography 76%, and stress tests 78%, which varied between stress modalities. Coronary angiography (invasive or computed tomography) decreased 55% (p < 0.001 for each procedure). In multivariable regression, significantly greater reduction in procedures occurred for centers in countries with lower gross domestic product. Location in a low-income and lower-middle-income country was associated with an additional 22% reduction in cardiac procedures and less availability of personal protective equipment and telehealth. CONCLUSIONS: COVID-19 was associated with a significant and abrupt reduction in cardiovascular diagnostic testing across the globe, especially affecting the world's economically challenged. Further study of cardiovascular outcomes and COVID-19-related changes in care delivery is warranted.


Assuntos
COVID-19 , Cardiopatias/diagnóstico , Técnicas de Diagnóstico Cardiovascular/estatística & dados numéricos , Saúde Global , Pesquisas sobre Atenção à Saúde , Humanos , Agências Internacionais
19.
JACC Cardiovasc Imaging ; 14(9): 1787-1799, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34147434

RESUMO

OBJECTIVES: This study sought to quantify and compare the decline in volumes of cardiovascular procedures between the United States and non-U.S. institutions during the early phase of the coronavirus disease-2019 (COVID-19) pandemic. BACKGROUND: The COVID-19 pandemic has disrupted the care of many non-COVID-19 illnesses. Reductions in diagnostic cardiovascular testing around the world have led to concerns over the implications of reduced testing for cardiovascular disease (CVD) morbidity and mortality. METHODS: Data were submitted to the INCAPS-COVID (International Atomic Energy Agency Non-Invasive Cardiology Protocols Study of COVID-19), a multinational registry comprising 909 institutions in 108 countries (including 155 facilities in 40 U.S. states), assessing the impact of the COVID-19 pandemic on volumes of diagnostic cardiovascular procedures. Data were obtained for April 2020 and compared with volumes of baseline procedures from March 2019. We compared laboratory characteristics, practices, and procedure volumes between U.S. and non-U.S. facilities and between U.S. geographic regions and identified factors associated with volume reduction in the United States. RESULTS: Reductions in the volumes of procedures in the United States were similar to those in non-U.S. facilities (68% vs. 63%, respectively; p = 0.237), although U.S. facilities reported greater reductions in invasive coronary angiography (69% vs. 53%, respectively; p < 0.001). Significantly more U.S. facilities reported increased use of telehealth and patient screening measures than non-U.S. facilities, such as temperature checks, symptom screenings, and COVID-19 testing. Reductions in volumes of procedures differed between U.S. regions, with larger declines observed in the Northeast (76%) and Midwest (74%) than in the South (62%) and West (44%). Prevalence of COVID-19, staff redeployments, outpatient centers, and urban centers were associated with greater reductions in volume in U.S. facilities in a multivariable analysis. CONCLUSIONS: We observed marked reductions in U.S. cardiovascular testing in the early phase of the pandemic and significant variability between U.S. regions. The association between reductions of volumes and COVID-19 prevalence in the United States highlighted the need for proactive efforts to maintain access to cardiovascular testing in areas most affected by outbreaks of COVID-19 infection.


Assuntos
COVID-19 , Pandemias , Teste para COVID-19 , Humanos , Valor Preditivo dos Testes , SARS-CoV-2 , Estados Unidos/epidemiologia
20.
JACC Cardiovasc Imaging ; 14(9): 1819-1828, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33454257

RESUMO

OBJECTIVES: This study sought to describe worldwide variations in the use of myocardial perfusion imaging hardware, software, and imaging protocols and their impact on radiation effective dose (ED). BACKGROUND: Concerns about long-term effects of ionizing radiation have prompted efforts to identify strategies for dose optimization in myocardial perfusion scintigraphy. Studies have increasingly shown opportunities for dose reduction using newer technologies and optimized protocols. METHODS: Data were submitted voluntarily to the INCAPS (International Atomic Energy Agency Nuclear Cardiology Protocols Study) registry, a multinational, cross-sectional study comprising 7,911 imaging studies from 308 labs in 65 countries. The study compared regional use of camera technologies, advanced post-processing software, and protocol characteristics and analyzed the influence of each factor on ED. RESULTS: Cadmium-zinc-telluride and positron emission tomography (PET) cameras were used in 10% (regional range 0% to 26%) and 6% (regional range 0% to 17%) of studies worldwide. Attenuation correction was used in 26% of cases (range 10% to 57%), and advanced post-processing software was used in 38% of cases (range 26% to 64%). Stress-first single-photon emission computed tomography (SPECT) imaging comprised nearly 20% of cases from all world regions, except North America, where it was used in just 7% of cases. Factors associated with lower ED and odds ratio for achieving radiation dose ≤9 mSv included use of cadmium-zinc-telluride, PET, advanced post-processing software, and stress- or rest-only imaging. Overall, 39% of all studies (97% PET and 35% SPECT) were ≤9 mSv, while just 6% of all studies (32% PET and 4% SPECT) achieved a dose ≤3 mSv. CONCLUSIONS: Newer-technology cameras, advanced software, and stress-only protocols were associated with reduced ED, but worldwide adoption of these practices was generally low and varied significantly between regions. The implementation of dose-optimizing technologies and protocols offers an opportunity to reduce patient radiation exposure across all world regions.


Assuntos
Cardiologia , Imagem de Perfusão do Miocárdio , Estudos Transversais , Humanos , Valor Preditivo dos Testes , Doses de Radiação , Software , Tecnologia , Tomografia Computadorizada de Emissão de Fóton Único , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA