Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Catheter Cardiovasc Interv ; 92(7): E527-E536, 2018 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-30265435

RESUMO

Cardiac allograft vasculopathy (CAV) is a complex disease that remains a significant cause of morbidity and mortality after orthotopic heart transplantation (OHT). Originating as a result of inflammatory response, the development and progression of CAV is attributed to endothelial dysfunction, cellular infiltration, and a wide-range of genetic and patient factors. The detection of CAV remains a diagnostic challenge, as symptoms can be variable or absent. While coronary angiography remains the initial test of choice for the diagnosis and surveillance of CAV, intravascular imaging (either by ultrasound or optical coherence tomography) and physiologic assessments are useful adjuncts in the cardiac catheterization laboratory. Positron emission tomography, computed tomographic, and magnetic resonance imaging may have a role increasing the time interval between invasive screening tests for prognosis. Medical management should include a statin, vasodilator, and tailored immunosuppressive regimen that maximally decrease allograft rejection and CAV progression while causing minimal side effects. Patients that are less responsive to pharmacotherapy should be considered for invasive management with percutaneous coronary intervention. Although surgical revascularization is a poor option, repeat OHT is the only definitive treatment option but given its morbidity should be reserved for a highly selected patient population.


Assuntos
Doença da Artéria Coronariana/etiologia , Transplante de Coração/efeitos adversos , Animais , Fármacos Cardiovasculares/uso terapêutico , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Doença da Artéria Coronariana/terapia , Sobrevivência de Enxerto , Transplante de Coração/mortalidade , Humanos , Imunossupressores/efeitos adversos , Intervenção Coronária Percutânea , Valor Preditivo dos Testes , Reoperação , Fatores de Risco , Resultado do Tratamento
2.
JACC Adv ; 3(3): 100839, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38938839

RESUMO

Background: Augmented reality (AR) guidance holds potential to improve transcatheter interventions by enabling visualization of and interaction with patient-specific 3-dimensional virtual content. Positioning of cerebral embolic protection devices (CEP) during transcatheter aortic valve replacement (TAVR) increases patient exposure to radiation and iodinated contrast, and increases procedure time. AR may enhance procedural guidance and facilitate a safer intervention. Objectives: The purpose of this study was to develop and test a novel AR guidance system with a custom user interface that displays virtual, patient-specific 3-dimensional anatomic models, and assess its intraprocedural impact during CEP placement in TAVR. Methods: Patients undergoing CEP during TAVR were prospectively enrolled and assigned to either AR guidance or control groups. Primary endpoints were contrast volume used prior to filter placement, times to filter placement, and fluoroscopy time. Postprocedure questionnaires were administered to assess intraprocedural physician experience with AR guidance. Results: A total of 24 patients presenting for TAVR were enrolled in the study (12 with AR guidance and 12 controls). AR guidance eliminated the need for aortic arch angiograms prior to device placement thus reducing contrast volume (0 mL vs 15 mL, P < 0.0001). There was no significant difference in the time required for filter placement or fluoroscopy time. Postprocedure questionnaires indicated that AR guidance increased confidence in wiring of the aortic arch and facilitated easier device placement. Conclusions: We developed a novel AR guidance system that eliminated the need for additional intraprocedural angiograms prior to device placement without any significant difference in time to intervention and offered a subjective improvement in performance of the intervention.

3.
JACC Cardiovasc Interv ; 12(2): 182-193, 2019 01 28.
Artigo em Inglês | MEDLINE | ID: mdl-30678797

RESUMO

OBJECTIVES: The aim of this study was to evaluate the predictors of left ventricular outflow tract (LVOT) obstruction after transcatheter mitral valve replacement (TMVR). BACKGROUND: LVOT obstruction is a major concern with TMVR, but limited data exist regarding its predictors and impact on outcomes. METHODS: Patients with pre-procedural multidetector row computed tomography (MDCT) undergoing TMVR for failed mitral bioprosthetic valves (valve-in-valve), annuloplasty rings (valve-in-ring), and mitral annular calcification (valve-in-MAC) were included in this study. Echocardiographic and procedural characteristics were recorded, and comprehensive assessment with MDCT was performed to identify the predictors of LVOT obstruction (defined as an increment of mean LVOT gradient ≥10 mm Hg from baseline). The new LVOT (neo-LVOT) area left after TMVR was estimated by embedding a virtual valve into the mitral annulus on MDCT, simulating the procedure. RESULTS: Among 194 patients with pre-procedural MDCT undergoing TMVR (valve-in-valve, 107 patients; valve-in-ring, 50 patients; valve-in-MAC, 37 patients), LVOT obstruction was observed in 26 patients (13.4%), with a higher rate after valve-in-MAC than valve-in-ring and valve-in-valve (54.1% vs. 8.0% vs. 1.9%; p < 0.001). Patients with LVOT obstruction had significantly higher procedural mortality compared with those without LVOT obstruction (34.6% vs. 2.4%; p < 0.001). Receiver-operating characteristic curve analysis showed that an estimated neo-LVOT area ≤1.7 cm2 predicted LVOT obstruction with sensitivity of 96.2% and specificity of 92.3%. CONCLUSIONS: LVOT obstruction after TMVR was associated with higher procedural mortality. A small estimated neo-LVOT area was significantly associated with LVOT obstruction after TMVR and may help identify patients at high risk for LVOT obstruction.


Assuntos
Calcinose/cirurgia , Cateterismo Cardíaco/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Insuficiência da Valva Mitral/cirurgia , Estenose da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Obstrução do Fluxo Ventricular Externo/etiologia , Idoso , Idoso de 80 Anos ou mais , Calcinose/diagnóstico por imagem , Calcinose/mortalidade , Calcinose/fisiopatologia , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/mortalidade , Ecocardiografia , Feminino , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Masculino , Valva Mitral/diagnóstico por imagem , Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/mortalidade , Insuficiência da Valva Mitral/fisiopatologia , Estenose da Valva Mitral/diagnóstico por imagem , Estenose da Valva Mitral/mortalidade , Estenose da Valva Mitral/fisiopatologia , Tomografia Computadorizada Multidetectores , Desenho de Prótese , Falha de Prótese , Sistema de Registros , Medição de Risco , Fatores de Risco , Resultado do Tratamento , Obstrução do Fluxo Ventricular Externo/diagnóstico por imagem , Obstrução do Fluxo Ventricular Externo/mortalidade , Obstrução do Fluxo Ventricular Externo/fisiopatologia
5.
Ann Thorac Surg ; 95(5): 1791-3, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23608264

RESUMO

We describe the case of a 60-year-old man with prior rotational atherectomy and drug-eluting stent to the left anterior descending artery (LAD) who presented with shortness of breath and chest pain 8 weeks after stent placement. Further workup revealed a large pericardial effusion with gram stain positive for methicillin-resistant Staphylococcus aureus. Subsequently, this was shown to be related to an aneurysm at the site of the prior LAD stent. This case demonstrated coronary stent infection with mycotic aneurysm and purulent pericardial effusion as an extremely rare but serious complication of percutaneous coronary intervention.


Assuntos
Aneurisma Infectado/etiologia , Aneurisma Coronário/etiologia , Stents Farmacológicos/efeitos adversos , Derrame Pericárdico/etiologia , Humanos , Masculino , Staphylococcus aureus Resistente à Meticilina/isolamento & purificação , Pessoa de Meia-Idade , Supuração/etiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA