Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
1.
Am J Otolaryngol ; 43(1): 103263, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34653954

RESUMO

OBJECTIVES: During the COVID-19 pandemic, maintenance of safe and timely oncologic care has been challenging. The goal of this study is to compare presenting symptoms, staging, and treatment of head and neck mucosal squamous cell carcinoma during the pandemic with an analogous timeframe one year prior. MATERIALS AND METHODS: Retrospective cohort study at a single tertiary academic center of new adult patients evaluated in a head and neck surgical oncology clinic from March -July 2019 (pre-pandemic control) and March - July 2020 (COVID-19 pandemic). RESULTS: During the pandemic, the proportion of patients with newly diagnosed malignancies increased by 5%, while the overall number of new patients decreased (n = 575) compared to the control year (n = 776). For patients with mucosal squamous cell carcinoma (SCC), median time from referral to initial clinic visit decreased from 11 days (2019) to 8 days (2020) (p = 0.0031). There was no significant difference in total number (p = 0.914) or duration (p = 0.872) of symptoms. During the pandemic, patients were more likely to present with regional nodal metastases (adjusted odds ratio (OR) 2.846, 95% CI 1.072-3.219, p = 0.028) and more advanced clinical nodal (N) staging (p = 0.011). No significant difference was seen for clinical tumor (T) (p = 0.502) or metastasis (M) staging (p = 0.278). No significant difference in pathologic T (p = 0.665), or N staging (p = 0.907) was found between the two periods. CONCLUSION: Head and neck mucosal SCC patients presented with more advanced clinical nodal disease during the early months of the COVID-19 pandemic despite no change in presenting symptoms.


Assuntos
COVID-19/epidemiologia , Carcinoma de Células Escamosas de Cabeça e Pescoço/epidemiologia , Carcinoma de Células Escamosas de Cabeça e Pescoço/patologia , Idoso , Feminino , Humanos , Metástase Linfática , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Pandemias , Estudos Retrospectivos , SARS-CoV-2 , Carcinoma de Células Escamosas de Cabeça e Pescoço/terapia , Tennessee/epidemiologia
3.
Artigo em Inglês | MEDLINE | ID: mdl-38842041

RESUMO

OBJECTIVE: To compare speech recognition and quality of life outcomes between bilateral sequentially and simultaneously implanted adult cochlear implant (CI) recipients who initially qualify for a CI in both ears. STUDY DESIGN: Retrospective chart review. SETTING: Tertiary referral center. METHODS: Retrospective chart review identified adults who underwent bilateral CI, either simultaneously or sequentially, at a high-volume center between 2012 and 2022. Sequentially implanted patients were only included if the second ear qualified for CI in quiet (defined as best-aided AzBio quiet testing <60%), at time of initial CI evaluation. RESULTS: Of 112 bilateral CI patients who qualified in both ears at initial evaluation, 95 underwent sequential implantation and 17 simultaneous. Age, duration, and etiology of hearing loss, and CI usage were similar between groups. Preoperatively, the sequential group had lower pure-tone average (PTA) in the 1st ear than the simultaneously implanted group (P = <.001) but, no difference in 2nd ear PTA (P = .657). Preoperative speech recognition scores were significantly higher for the sequential group; however, this was not true for postoperative scores. There was no difference in the proportion of patients showing significant CI-only or bilateral performance improvement between the groups. Both groups demonstrated similar benefit in quality of life measures. CONCLUSION: Our findings indicate both simultaneous and sequential cochlear implantation are effective in improving hearing performance and quality of life. Thus, bilateral versus simultaneous implantation should be discussed and tailored for each individual patient.

4.
Otol Neurotol ; 45(4): 426-429, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38437815

RESUMO

OBJECTIVE: Comparison of outcomes of microscopic and endoscopic resection of glomus tympanicum (GT) tumors. STUDY DESIGN: Retrospective case review. SETTING: Single tertiary referral center. PATIENTS: All adult patients undergoing transcanal GT resection without mastoidectomy from 2007 to 2021. INTERVENTIONS: Surgical resection-endoscopic versus microscopic approach. MAIN OUTCOME MEASURES: Primary outcomes were tumor recurrence at 1 year and presence of residual tumor at conclusion of surgery. Secondary outcome measures included operative time, postoperative air-bone gap, postoperative symptom resolution, and surgical complications. RESULTS: Thirty-eight patients underwent resection of GT (74% female; mean age, 59 years). Twenty-nine cases were performed microscopically, and nine cases were performed endoscopically. Both endoscopic and microscopic approaches yielded high rates of complete tumor resection (27/29 microscopic cases, 7/9 endoscopic cases). There was no significant difference in mean operative time (2.3 hours for microscopic; 2.6 hours for endoscopic). On average, air-bone gaps (ABGs) decreased by 6.3 dB after endoscopic resection compared with 1.0 dB after microscopic resection ( p = 0.064). No patients were found to have tumor recurrence during an average follow-up interval of 21 months. CONCLUSIONS: These results suggest comparable outcomes with both endoscopic and microscopic approaches for GT resection, and decisions regarding preferred approach should be dictated by surgeon preference.


Assuntos
Glomo Timpânico , Adulto , Humanos , Feminino , Pessoa de Meia-Idade , Masculino , Estudos Retrospectivos , Recidiva Local de Neoplasia/cirurgia , Resultado do Tratamento , Endoscopia/métodos
5.
Otolaryngol Head Neck Surg ; 170(5): 1411-1420, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38353294

RESUMO

OBJECTIVE: To assess patient factors, audiometric performance, and patient-reported outcomes in cochlear implant (CI) patients who would not have qualified with in-quiet testing alone. STUDY DESIGN: Retrospective chart review. SETTING: Tertiary referral center. METHODS: Adult CI recipients implanted between 2012 and 2022 were identified. Patients with preoperative AzBio Quiet > 60% in the implanted ear, requiring multitalker babble to qualify, comprised the in-noise qualifying (NQ) group. NQ postoperative performance was compared with the in-quiet qualifying (QQ) group using CNC, AzBio Quiet, and AzBio +5 dB signal-to-noise ratio. Speech, Spatial and Qualities of Hearing Scale (SSQ), Cochlear Implant Quality of Life scale (CIQOL-10), and daily device usage were also compared between the groups. RESULTS: The QQ group (n = 771) and NQ group (n = 67) were similar in age and hearing loss duration. NQ had higher average preoperative and postoperative speech recognition scores. A larger proportion of QQ saw significant improvement in CNC and AzBio Quiet scores in the CI-only listening condition (eg, CI-only AzBio Quiet: 88% QQ vs 51% NQ, P < .001). Improvement in CI-only AzBio +5 dB and in all open set testing in the best-aided binaural listening condition was similar between groups (eg, Binaural AzBio Quiet 73% QQ vs 59% NQ, P = .345). Postoperative SSQ ratings, CIQOL scores, and device usage were also equivalent between both groups. CONCLUSION: Patients who require in-noise testing to meet CI candidacy demonstrate similar improvements in best-aided speech perception and patient-reported outcomes as in-QQ, supporting the use of in-noise testing to determine CI qualification for borderline CI candidates.


Assuntos
Implante Coclear , Implantes Cocleares , Ruído , Qualidade de Vida , Percepção da Fala , Humanos , Estudos Retrospectivos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Implante Coclear/métodos , Medidas de Resultados Relatados pelo Paciente , Adulto , Resultado do Tratamento , Período Pós-Operatório
6.
Cochlear Implants Int ; : 1-9, 2024 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-38738388

RESUMO

OBJECTIVES: Evaluate potential effects of calcium channel blockers (CCB) and bisphosphonates (BP) on residual hearing following cochlear implantation. METHODS: Medications of 303 adult hearing preservation (HP) candidates (low frequency pure tone average [LFPTA] of 125, 250, and 500 Hz ≤80 dB HL) were reviewed. Postimplantation LFPTA of patients taking CCBs and BPs were compared to controls matched by age and preimplantation LFPTA. RESULTS: Twenty-six HP candidates were taking a CCB (N = 14) or bisphosphonate (N = 12) at implantation. Median follow-up was 1.37 years (range 0.22-4.64y). Among subjects with initial HP, 29% (N = 2 of 7) CCB users compared to 50% (N = 2 of 4) controls subsequently lost residual hearing 3-6 months later (OR = 0.40, 95% CI = 0.04-4.32, p = 0.58). None of the four BP patients with initial HP experienced delayed loss compared to 50% (N = 2 of 4) controls with initial HP (OR = 0.00, 95% CI = 0.00-1.95, P = 0.43). Two CCB and one BP patients improved to a LFPTA <80 dB HL following initial unaided thresholds that suggested loss of residual hearing. DISCUSSION: There were no significant differences in the odds of delayed loss of residual hearing with CCBs or BPs. CONCLUSION: Further investigation into potential otoprotective adjuvants for maintaining residual hearing following initial successful hearing preservation is warranted, with larger cohorts and additional CCB/BP agents.

7.
Otolaryngol Head Neck Surg ; 170(6): 1676-1683, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38494744

RESUMO

OBJECTIVES: Social media has enabled discussion of relevant topics within otolaryngology. With increasing academic discourse occurring on virtual platforms, it is important to examine who is influencing these discussions. This study thus aims to: (1) identify the top Twitter influencers in otolaryngology and (2) assess the relationship between Twitter influence and academic impact. STUDY DESIGN: Cross-sectional analysis. SETTING: Twitter. METHODS: The Right Relevance program was used to identify and rank the top 75 Twitter influencers, excluding organizations, according to the search terms "otolaryngology," "head and neck surgery," "ear nose throat," "rhinology," "head and neck," "laryngology," "facial plastics," and "otology." Demographic data and h-index were collected for each influencer. Correlational analyzes were performed to assess the relationships between Twitter rank and geographic location, sex, subspecialty, and h-index. RESULTS: The majority of the top 75 influencers were otolaryngologists (87%), female (68%), and located in the United States (61%). General otolaryngology (n = 20, 31%) was more well-represented than any individual subspecialty including facial plastics (n = 10, 15%), rhinology (n = 10, 15%), and neurotology (n = 9, 14%). There was a significant relationship between Twitter rank and h-index (Spearman ρ value of -0.32; 95% confidence interval: -0.51 to -0.01; P = .006). Twitter rank was not significantly correlated with subspecialty, sex, or geographic location (P > .05). CONCLUSION: The majority of Twitter influencers within otolaryngology were otolaryngologists, female, and located in the United States. Social media influence is positively associated with academic impact among otolaryngologists.


Assuntos
Otolaringologia , Mídias Sociais , Mídias Sociais/estatística & dados numéricos , Estudos Transversais , Humanos , Feminino , Masculino , Estados Unidos
8.
Otol Neurotol ; 45(1): 52-57, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-38013487

RESUMO

OBJECTIVE: To assess speech recognition and hearing preservation (HP) outcomes with the Advanced Bionics Mid-Scala and SlimJ electrodes. STUDY DESIGN: Retrospective cohort. SETTING: Tertiary referral center. PATIENTS: A total of 237 adult patients implanted between 2013 and 2020 (Mid-Scala, n = 136; SlimJ, n = 101). MAIN OUTCOME MEASURES: Consonant-nucleus-consonant (CNC) and AzBio (Arizona Biomedical) scores at 6 and 12 months; postoperative HP, defined as low-frequency pure-tone average ≤ 80 dB HL; scalar position. RESULTS: Mean CNC scores did not significantly differ between Mid-Scala and SlimJ recipients at 6 (45.8% versus 46.0%, p = 0.962) and 12 (51.9% versus 48.8%, p = 0.363) months. Similarly, mean AzBio in quiet scores were equivalent for both groups at 6 (55.1% versus 59.2%, p = 0.334) and 12 (60.6% versus 62.3%, p = 0.684) months. HP rates were significantly higher with the SlimJ (48.4%) than the Mid-Scala (30.8%; p = 0.033). Scalar translocations were 34.8 and 16.1% for the Mid-Scala and SlimJ groups, respectively ( p = 0.019). Ears with postoperative HP had significantly fewer scalar translocations (16.7% versus 37.2%, p = 0.048), and postoperative HP was associated with higher AzBio in noise scores at the most recent follow-up interval (38.7% versus 25.1%, p = 0.042). CNC, AzBio in quiet and noise, low-frequency pure-tone average shifts, and PTA at 6 and 12 months were not significantly different between patients with scala tympani insertions of the SlimJ versus the Mid-Scala ( p > 0.05). CONCLUSIONS: Compared with the Mid-Scala, the lateral wall electrode has superior HP rates and fewer scalar translocations, whereas speech recognition scores are equivalent between both electrode arrays. These findings can help providers with electrode selection and patient counseling.


Assuntos
Implante Coclear , Implantes Cocleares , Percepção da Fala , Adulto , Humanos , Estudos Retrospectivos , Audição , Resultado do Tratamento
9.
Otol Neurotol ; 45(4): 386-391, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38437818

RESUMO

OBJECTIVE: To report speech recognition outcomes and processor use based on timing of cochlear implant (CI) activation. STUDY DESIGN: Retrospective cohort. SETTING: Tertiary referral center. PATIENTS: A total of 604 adult CI recipients from October 2011 to March 2022, stratified by timing of CI activation (group 1: ≤10 d, n = 47; group 2: >10 d, n = 557). MAIN OUTCOME MEASURES: Average daily processor use; Consonant-Nucleus-Consonant (CNC) and Arizona Biomedical (AzBio) in quiet at 1-, 3-, 6-, and 12-month visits; time to peak performance. RESULTS: The groups did not differ in sex ( p = 0.887), age at CI ( p = 0.109), preoperative CNC ( p = 0.070), or preoperative AzBio in quiet ( p = 0.113). Group 1 had higher median daily processor use than group 2 at the 1-month visit (12.3 versus 10.7 h/d, p = 0.017), with no significant differences at 3, 6, and 12 months. The early activation group had superior median CNC performance at 3 months (56% versus 46%, p = 0.007) and 12 months (60% versus 52%, p = 0.044). Similarly, the early activation group had superior median AzBio in quiet performance at 3 months (72% versus 59%, p = 0.008) and 12 months (75% versus 68%, p = 0.049). Both groups were equivalent in time to peak performance for CNC and AzBio. Earlier CI activation was significantly correlated with higher average daily processor use at all follow-up intervals. CONCLUSION: CI activation within 10 days of surgery is associated with increased early device usage and superior speech recognition at both early and late follow-up visits. Timing of activation and device usage are modifiable factors that can help optimize postoperative outcomes in the CI population.


Assuntos
Implante Coclear , Implantes Cocleares , Percepção da Fala , Adulto , Humanos , Estudos Retrospectivos , Percepção da Fala/fisiologia , Fala , Resultado do Tratamento
10.
Ear Nose Throat J ; : 1455613231185031, 2023 Jul 11.
Artigo em Inglês | MEDLINE | ID: mdl-37431717

RESUMO

Congenital bilateral vocal fold paralysis (BVFP) is a rare but significant cause of morbidity in pediatric otolaryngology. The differential diagnosis is expansive, with common etiologies including birth trauma, brainstem neoplasms, and neurologic disorders. There are few known genetic causes of the condition. This report details the first known case of BVFP secondary to a genetic deficiency in MYOD1, a master transcriptional regulator of skeletal muscle cell specification. Genetics consultation and testing may be a useful adjunct in the workup of congenital BVFP and may help guide prognostication, additional workup, counseling, and clinical decision-making.

11.
Otol Neurotol ; 44(10): 1015-1020, 2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-37832582

RESUMO

OBJECTIVE: To study the relationship between Cochlear Implant Quality of Life-10 Global (CIQOL-10) scores and speech recognition scores 6 and 12 months after cochlear implantation (CI) and to compare CIQOL-10 scores for patients who met the benchmark speech recognition scores with those who did not. STUDY DESIGN: Retrospective review. SETTING: Tertiary referral center. PATIENTS: One hundred twenty-four adults who underwent CI between 2018 and 2021 and completed a CIQOL-10 questionnaire at their 6- and/or 12-month postoperative visit. MAIN OUTCOME MEASURES: CIQOL-10, Consonant-Nucleus-Consonant (CNC) word, and AzBio in quiet and noise scores. RESULTS: At 6 months, weak positive correlations were found between CIQOL-10 and CNC (n = 78, r = 0.234, p = 0.039) and AzBio in quiet (n = 73, r = 0.293, p = 0.012) scores but not AzBio in noise scores (n = 39, r = 0.207, p = 0.206). At 12 months, weak positive correlations were found between CIQOL-10 and CNC (n = 98, r = 0.315, p = 0.002), AzBio in quiet (n = 88, r = 0.271, p = 0.011), and AzBio in noise (n = 48, r = 0.291, p = 0.045) scores. Patients who met the benchmark CNC scores had notably higher CIQOL-10 scores than those who did not at 6 months (52.0 vs 45.5, p = 0.008) and 12 months (52.0 vs 45.5, p = 0.003). A similar relationship was found for those who met the benchmark AzBio in quiet scores at both 6 months (52.0 vs 44.0, p = 0.006) and 12 months (52.0 vs 46.5, p = 0.011). CONCLUSION: CIQOL-10 scores have weak positive correlations with postoperative speech recognition outcomes at 6 and 12 months. This highlights the need for the continued use of quality-of-life measures, such as the CIQOL-10, in assessing CI outcomes to gain a more comprehensive understanding of patients' experiences.


Assuntos
Implante Coclear , Implantes Cocleares , Percepção da Fala , Adulto , Humanos , Qualidade de Vida , Ruído , Estudos Retrospectivos , Resultado do Tratamento
12.
Otolaryngol Head Neck Surg ; 169(6): 1615-1623, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37232481

RESUMO

OBJECTIVE: Cochlear implants (CIs) for single-sided deafness (SSD) have only been approved for patients 5 years and older despite data supporting that younger children can also benefit from implantation. This study describes our institution's experience with CI for SSD in children 5 years and younger. STUDY DESIGN: Case series with chart review. SETTING: Tertiary referral center. METHODS: A case series with chart review identified 19 patients up to age 5 years who underwent CI for SSD between 2014 and 2022. Baseline characteristics, perioperative complications, device usage, and speech outcomes were collected. RESULTS: The median age at CI was 2.8 (range, 1.0-5.4) years, with 15 (79%) patients being below age 5 at implantation. Etiologies of hearing loss were idiopathic (n = 8), cytomegalovirus (n = 4), enlarged vestibular aqueduct (n = 3), hypoplastic cochlear nerve (n = 3), and meningitis (n = 1). The median preoperative pure-tone average was 90 (range, 75-120) and 20 (range, 5-35) dB eHL in the poor and better hearing ears, respectively. No patients had postoperative complications. Twelve patients achieved consistent device use (average, 9 h/d). Three of the seven who were not consistent users had hypoplastic cochlear nerves and/or developmental delays. The three patients with available preoperative and postoperative speech testing showed significant benefits, and five patients with available postoperative testing demonstrated speech recognition in the implanted ear when isolated from the better ear. CONCLUSION: CI can safely be performed in younger children with SSD. Patients and families accept early implantation, as evidenced by consistent device use, and derive notable benefits in speech recognition. Candidacy can be broadened to include SSD patients under age five years, particularly individuals without hypoplastic cochlear nerves or developmental delay.


Assuntos
Implante Coclear , Implantes Cocleares , Surdez , Perda Auditiva Neurossensorial , Perda Auditiva Unilateral , Percepção da Fala , Humanos , Criança , Pré-Escolar , Lactente , Implante Coclear/efeitos adversos , Surdez/cirurgia , Perda Auditiva Unilateral/cirurgia , Perda Auditiva Unilateral/etiologia , Perda Auditiva Neurossensorial/complicações , Implantes Cocleares/efeitos adversos
13.
Otol Neurotol ; 44(7): e486-e491, 2023 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-37400135

RESUMO

OBJECTIVE: To develop a machine learning-based referral guideline for patients undergoing cochlear implant candidacy evaluation (CICE) and to compare with the widely used 60/60 guideline. STUDY DESIGN: Retrospective cohort. SETTING: Tertiary referral center. PATIENTS: 772 adults undergoing CICE from 2015 to 2020. INTERVENTIONS: Variables included demographics, unaided thresholds, and word recognition score. A random forest classification model was trained on patients undergoing CICE, and bootstrap cross-validation was used to assess the modeling approach's performance. MAIN OUTCOME MEASURES: The machine learning-based referral tool was evaluated against the 60/60 guideline based on ability to identify CI candidates under traditional and expanded criteria. RESULTS: Of 587 patients with complete data, 563 (96%) met candidacy at our center, and the 60/60 guideline identified 512 (87%) patients. In the random forest model, word recognition score; thresholds at 3000, 2000, and 125; and age at CICE had the largest impact on candidacy (mean decrease in Gini coefficient, 2.83, 1.60, 1.20, 1.17, and 1.16, respectively). The 60/60 guideline had a sensitivity of 0.91, a specificity of 0.42, and an accuracy of 0.89 (95% confidence interval, 0.86-0.91). The random forest model obtained higher sensitivity (0.96), specificity (1.00), and accuracy (0.96; 95% confidence interval, 0.95-0.98). Across 1,000 bootstrapped iterations, the model yielded a median sensitivity of 0.92 (interquartile range [IQR], 0.85-0.98), specificity of 1.00 (IQR, 0.88-1.00), accuracy of 0.93 (IQR, 0.85-0.97), and area under the curve of 0.96 (IQR, 0.93-0.98). CONCLUSIONS: A novel machine learning-based screening model is highly sensitive, specific, and accurate in predicting CI candidacy. Bootstrapping confirmed that this approach is potentially generalizable with consistent results.


Assuntos
Implante Coclear , Implantes Cocleares , Adulto , Humanos , Estudos Retrospectivos , Implante Coclear/métodos , Aprendizado de Máquina , Seleção de Pacientes
14.
Laryngoscope ; 133(9): 2255-2263, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-36286239

RESUMO

OBJECTIVES: Serial intralesional steroid injection (SILSI) has been increasingly used to treat idiopathic subglottic stenosis (iSGS). Prior studies have shown effectiveness, but not in all patients. This multi-institutional study evaluates the effect of SILSI on time to recurrent operation, peak expiratory flow (PEF), and dyspnea. METHODS: Post-hoc secondary analysis of the North American Airway Collaborative data were performed to evaluate the outcomes of iSGS patients undergoing and not undergoing SILSI. The primary outcome was time to recurrent operation, evaluated using Kaplan-Meier curves and Cox regression analysis. Secondary outcomes were change in PEF and clinical chronic obstructive pulmonary disease questionnaire (CCQ) score. Within patients undergoing SILSI, demographics, time from last procedure, and PEF at initiation of SILSI were evaluated to determine the effect on recurrence. RESULTS: Two hundred and ninety patients were included, 238 undergoing endoscopic dilation alone and 52 undergoing dilation and SILSI. No differences in baseline characteristics were observed. There was no difference in time to recurrence (hazard ratio: 0.64; p = 0.183). There were no differences in PEF or CCQ across the 2.5-year study period. Among 52 patients undergoing SILSI, PEF at the time of starting SILSI did not affect recurrence (χ2  = 0.09, p = 0.77). CONCLUSION: Patients undergoing and not undergoing SILSI had similar times to recurrence, PEF, and CCQ. Factors predicting recurrence among patients undergoing SILSI were not identified. These results support a randomized controlled trial with a uniform SILSI protocol to quantify the effects of SILSI on objective and subjective outcomes and help determine which iSGS patients benefit most. LEVEL OF EVIDENCE: 3 Laryngoscope, 133:2255-2263, 2023.


Assuntos
Laringoestenose , Humanos , Constrição Patológica/complicações , Resultado do Tratamento , Laringoestenose/cirurgia , Esteroides/uso terapêutico , Endoscopia , Injeções Intralesionais
15.
Otol Neurotol ; 44(4): 353-359, 2023 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-36843071

RESUMO

OBJECTIVE: Compare incidence of sigmoid sinus wall abnormalities (SSWAs) and other radiographic abnormalities in patients with pulsatile tinnitus (PT) versus controls. STUDY DESIGN: Retrospective case-control. SETTING: Tertiary referral center. PATIENTS: Adults with PT and high-resolution computed tomography imaging were compared with adults undergoing cochlear implant workup including high-resolution computed tomography imaging. MAIN OUTCOME MEASURES: Incidence of SSWA in PT cohort (n = 141) compared with control (n = 149, n = 298 ears). Secondary outcome measures included differences in demographics and in other radiographic abnormalities between cohorts. RESULTS: Patients with PT had a higher incidence of SSWA (34% versus 9%, p < 0.001) and superior canal dehiscence (23% versus 12%, p = 0.017) than controls. Spearman product component correlations demonstrated that ipsilateral PT was weakly associated with SSWA ( r = 0.354, p < 0.001). When SSWA was present in the PT cohort (n = 48 patients, n = 59 ears), in 31 cases (64.6%), the SSWA correlated with PT laterality (e.g., left SSWA, left PT); in 12 (25.0%), SSWA partially correlated with PT laterality (e.g., bilateral SSWA, right PT); and in 5 (10.4%), the SSWA did not correlate with PT laterality (e.g., right SSWA, left PT). CONCLUSIONS: For our patients with both PT and SSWA, the SSWA is likely a contributing factor in approximately 65% of cases. For a third of patients with PT and concomitant SSWA, the association between the two is either not causative or not solely causative. Surgeons counseling patients with PT and SSWA may be optimistic overall regarding sigmoid resurfacing procedures but must appreciate the possibility of treatment failure, likely because of untreated comorbid conditions.


Assuntos
Zumbido , Adulto , Humanos , Zumbido/diagnóstico por imagem , Zumbido/etiologia , Zumbido/cirurgia , Estudos de Casos e Controles , Estudos Retrospectivos , Cavidades Cranianas/diagnóstico por imagem , Cavidades Cranianas/cirurgia , Tomografia Computadorizada por Raios X
16.
Otol Neurotol ; 44(7): e479-e485, 2023 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-37442607

RESUMO

OBJECTIVE: To quantify the effect of datalogging on speech recognition scores and time to achievement for a "benchmark" level of performance within the first year, and to provide a data-driven recommendation for minimum daily cochlear implant (CI) device usage to better guide patient counseling and future outcomes. STUDY DESIGN: Retrospective cohort. SETTING: Tertiary referral center. PATIENTS: Three hundred thirty-seven adult CI patients with data logging and speech recognition outcome data who were implanted between August 2015 and August 2020. MAIN OUTCOME MEASURES: Processor datalogging, speech recognition scores, achievement of "benchmark speech recognition performance" defined as 80% of the median score for speech recognition outcomes at our institution. RESULTS: The 1-month datalogging measure correlated positively with word and sentences scores at 1, 3, 6, and 12 months postactivation. Compared with age, sex, and preoperative performance, datalogging was the largest predictive factor of benchmark achievement on multivariate analysis. Each hour/day increase of device usage at 1 month resulted in a higher likelihood of achieving benchmark consonant-nucleus-consonant and AzBio scores within the first year (odds ratio = 1.21, p < 0.001) as well as earlier benchmark achievement. Receiver operating characteristic curve analysis identified the optimal data logging threshold at an average of 12 hours/day. CONCLUSIONS: Early CI device usage, as measured by 1-month datalogging, predicts benchmark speech recognition achievement in adults. Datalogging is an important predictor of CI performance within the first year postimplantation. These data support the recommended daily CI processor utilization of at least 12 hours/day to achieve optimal speech recognition performance for most patients.


Assuntos
Implante Coclear , Implantes Cocleares , Percepção da Fala , Adulto , Humanos , Estudos Retrospectivos , Percepção da Fala/fisiologia , Implante Coclear/métodos , Idioma , Resultado do Tratamento
17.
Laryngoscope ; 133(9): 2362-2370, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-36254870

RESUMO

OBJECTIVE: To report our experience for adults undergoing cochlear implantation (CI) for single-sided deafness (SSD). METHODS: This is a retrospective case series for adults with SSD who underwent CI between January 2013 and May 2021 at our institution. CNC and AzBio speech recognition scores, Tinnitus Handicap Inventory (THI), Speech, Spatial, and Qualities of Hearing Scale (SSQ12), datalogging, and the Cochlear Implant Quality of Life (CIQOL)-10 Global measure were utilized. RESULTS: Sixty-six adults underwent CI for SSD (median 51.3 years, range 20.0-74.3 years), and 57 (86.4%) remained device users at last follow-up. Compared to pre-operative performance, device users demonstrated significant improvement in speech recognition scores and achieved peak performance at six months post-activation for CNC (8.0% increased to 45.6%, p < 0.0001) and AzBio in quiet (12.2% increased to 59.5%, p < 0.0001). THI was decreased at 6 months post-implantation (58.1-14.6, p < 0.0001), with 77% of patients reporting improved or resolved tinnitus. Patients demonstrated improved SSQ12 scores as well as the disease-specific CIQOL-10 Global questionnaire. Duration of deafness was not associated with significant differences in speech recognition performance. Average daily wear time was positively associated with CNC and AzBio scores as well as post-operative CIQOL-10 scores. CONCLUSIONS: Herein we present the largest cohort of adult CI recipients with SSD with data on speech recognition scores, tinnitus measures, and SSQ12. Novel insights regarding the correlation of datalogging, duration of deafness, and CI-specific quality of life (CIQOL-10) metrics are discussed. Data continue to support CI as an efficacious treatment option for SSD. LEVEL OF EVIDENCE: 4 Laryngoscope, 133:2362-2370, 2023.


Assuntos
Implante Coclear , Implantes Cocleares , Perda Auditiva Unilateral , Percepção da Fala , Zumbido , Adulto , Humanos , Zumbido/cirurgia , Estudos Retrospectivos , Qualidade de Vida , Perda Auditiva Unilateral/cirurgia , Resultado do Tratamento , Percepção da Fala/fisiologia
18.
Otolaryngol Head Neck Surg ; 168(6): 1485-1493, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36939465

RESUMO

OBJECTIVE: To evaluate the safety and outcomes of cochlear implantation (CI) in patients with ventriculoperitoneal (VP) shunts to inform clinical practice. STUDY DESIGN: Historical cohort study. SETTING: Tertiary referral centers. METHODS: A multi-institutional historical cohort of patients with VP shunts and CI was identified and analyzed. RESULTS: A total of 46 patients (median age 8 years [interquratile range, IQR: 2-46]) with VP shunts and CI were identified. Of these, 41 (89%) patients had a VP shunt prior to CI. Based on institutional preference and individual patient factors, CI was performed contralateral to a pre-existing VP shunt in 24 of these 41 cases (59%) and ipsilateral in 17 (41%). Furthermore, pre-CI relocation of the VP shunt was performed in 3 cases (7%), and 2 patients (5%) underwent planned revision of their VP shunt concurrent with CI. In total, 2 of 27 pediatric patients (7%) required unanticipated revision shunt surgery, both contralateral to CI device placement, given VP shunt malfunction. One of 19 adult patients (5%) required shunt revision during CI due to shunt damage noted intraoperatively. Among 43 patients with available follow-up, 38 (88%) are regular CI users, with a median consonant-nucleus vowel-consonant word: score of 58% (IQR: 28-72). CONCLUSION: CI can be performed at low risk, either contralateral or ipsilateral, to a VP shunt, and does not mandate shunt revision in most cases. Additional considerations regarding CI receiver-stimulator placement are necessary with programmable shunts to mitigate device interaction. Preoperative planning, including coordination of care with neurosurgery, is important to achieving optimal outcomes.


Assuntos
Implante Coclear , Hidrocefalia , Adulto , Humanos , Criança , Derivação Ventriculoperitoneal , Estudos de Coortes , Estudos Retrospectivos
19.
Otol Neurotol ; 43(8): e820-e823, 2022 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-35833872

RESUMO

OBJECTIVE: This study aimed to assess the efficacy of same-day cochlear implant (SDCI) evaluation and surgery in improving patient experience. PATIENTS: Adult CI candidates participated in this study. INTERVENTIONS: Education materials and communication with providers were offered via telephone, e-mail, and/or telemedicine. Patients then arrived for in-person consultation, imaging studies, and outpatient CI surgery in one visit and received a 3-month postoperative survey. MAIN OUTCOME MEASURES: Preoperative hearing, referral-to-surgery time, travel burden, and patient satisfaction were included as outcome measures. RESULTS: Of 35 patients who qualified, 14 were successfully contacted regarding the same-day program: 9 underwent CI, 1 enrolled but did not ultimately meet candidacy criteria, and 4 declined because of coronavirus and/or active medical conditions and did not pursue a CI. For the nine patients who underwent SDCI, mean age was 78 years, and mean preoperative consonant-nucleus-consonant score was 16% in the implanted ear. Mean referral-to-surgery time was 103 days and, after accounting for cancellations because of coronavirus, was 52 days. Mean travel distance to institution was 234 miles. Of the seven patients who completed the follow-up survey, none felt rushed for surgery, and mean program experience was rated 8.6 out of 10. Net promoter score was positive (+72), supporting high experience favorability among patients. Barriers to program expansion included patient recruitment and education, surgery scheduling, and the coronavirus pandemic. CONCLUSIONS: No patients declined the SDCI program to pursue traditional CI evaluation, and all patients were satisfied with their experience. The SDCI program is a feasible and successful model that overcomes barriers to implantation, including travel burden, and improves access to care.


Assuntos
Implante Coclear , Implantes Cocleares , Perda Auditiva Neurossensorial , Adulto , Idoso , Implante Coclear/métodos , Perda Auditiva Neurossensorial/cirurgia , Humanos , Avaliação de Resultados da Assistência ao Paciente , Encaminhamento e Consulta
20.
Ann Otol Rhinol Laryngol ; 131(9): 954-961, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34617461

RESUMO

OBJECTIVE: To evaluate the impact of otolaryngology programs' social media on residency candidates in the 2020 to 2021 application cycle. METHODS: An anonymous survey was distributed via Otomatch, Headmirror, and word of mouth to otolaryngology residency applicants in the 2021 Match. Survey items included demographics, social media usage, and impact of programs' social media on applicant perception and ranking. Descriptive statistics were performed, and responses based on demographic variables were compared using Fisher's exact and Mann-Whitney U tests. RESULTS: Of 64 included respondents, nearly all (61/64, 95%) used Facebook, Instagram, and/or Twitter for personal and/or professional purposes. Applicants (59/64, 92%) most commonly researched otolaryngology residency programs on Instagram (55/59, 93%) and Twitter (36/59, 61%), with younger (P = .023) and female (P = .043) applicants being more likely to engage with programs on Instagram. Program accounts were most helpful in showcasing program culture (50/59, 85%) and highlighting its location (34/59, 58%). Nearly one third (19/59, 32%) reported that social media impacted their rank list. Age, gender, reapplication, home program status, or time taken off before and/or during medical school did not significantly influence social media's usefulness in the application cycle. CONCLUSION: Social media platforms like Instagram and Twitter are frequently used by applicants to assess otolaryngology residency programs. Programs' social media accounts effectively demonstrate program culture and affect applicants' rank lists. As social media usage continues to rise in the medical community, these findings can help otolaryngology residency programs craft a beneficial online presence that aids in recruitment, networking, and education.


Assuntos
Internato e Residência , Otolaringologia , Mídias Sociais , Feminino , Humanos , Otolaringologia/educação , Inquéritos e Questionários
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA