RESUMO
BACKGROUND: Left ventricular assist device (LVAD) implantation via thoracotomy has many potential advantages compared to conventional sternotomy, including improved inflow cannula (IFC) positioning. We compared the difference in IFC angles, postoperative, and long-term outcomes for patients with LVADs implanted via thoracotomy and sternotomy. METHODS: A single-center, retrospective analysis of 14 patients who underwent thoracotomy implantation was performed and matched with 28 patients who underwent sternotomy LVAD implantations for a total of 42 patients. Inclusion required a minimum LVAD support duration of 30 days and excluded concomitant procedures. A postoperative CT-chest was used to measure the angle the between the IFC and mitral valve in two-dimensions and results were compared with three-dimensional reconstruction using the same CT chest. Outcome data were extracted from medical records. RESULTS: There was no significant difference in gender, INTERMACS score, BMI, or age between the two groups. Median cardiopulmonary bypass time was longer in the thoracotomy group compared to the sternotomy group, 107 min (86-122) versus 76 min (56-93), p < 0.01. 3D reconstructions revealed less deviation of the IFC away from the mitral valve in devices implanted via thoracotomy compared to sternotomy, median (IQR) angle 16.3° (13.9°-21.0°) versus 23.2° (17.9°-26.4°), p < 0.01. Rates of pump thrombosis, stroke, and gastrointestinal bleeding were not significantly different. CONCLUSIONS: Devices implanted via thoracotomy demonstrated less deviation away from mitral valve. However, there was no difference in morbidity between the two approaches. 3D reconstruction of the heart is an innovative technique to measure angulation and is clinically advantageous when compared to 2D imaging.
Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Humanos , Esternotomia , Toracotomia/efeitos adversos , Cânula , Estudos Retrospectivos , Imageamento Tridimensional , Insuficiência Cardíaca/cirurgiaRESUMO
BACKGROUND: Vasoplegia has been shown to be associated with increased morbidity and mortality in patients undergoing cardiac surgery. It has been previously stated that low pulsatile states as seen with current left ventricular assist devices (LVADs) may contribute to vasoplegia post LVAD-explant and heart transplant. We sought to examine the literature regarding vasoplegia in the post-operative setting for patients undergoing LVAD explant and heart transplant. METHOD: A literature review was conducted to firstly define vasoplegia in the setting of LVAD patients, and secondly to better understand the relationship between vasoplegia and LVAD explantation in the postoperative heart transplant patient cohort. A keyword search of 'vasoplegia' OR 'vasoplegic' AND 'transplant' was used. Search engines used were PubMed, Cochrane Library, ClinicalTrials.gov, Ovid, Scopus and grey literature. RESULTS: 17 studies met the selection criteria for review. Three key themes emerged from the literature. Firstly, there is limited consensus regarding the definition of vasoplegia. Secondly, patients with LVADs experienced higher rates of vasoplegia following heart transplant than their counterparts and thirdly, increased cardiopulmonary bypass time was associated with a higher rate of vasoplegia. CONCLUSION: Vasoplegia is not clearly defined in the literature as it pertains to the LVAD patient cohort. Patients bridged with LVADs appear to have higher rates of vasoplegia, however the aetiology of this is unclear and may be associated with continuous flow physiology or prolonged cardiopulmonary bypass time. A universal definition will aid in risk stratification, early recognition and management.
Assuntos
Insuficiência Cardíaca , Transplante de Coração , Coração Auxiliar , Vasoplegia , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/cirurgia , Transplante de Coração/efeitos adversos , Coração Auxiliar/efeitos adversos , Humanos , Estudos Retrospectivos , Resultado do Tratamento , Vasoplegia/complicaçõesRESUMO
Low flow alarms represent a management challenge in patients with left ventricular assist devices because they are often a consequence of complex patient-device interactions. We present a case of intermittent suction of the postero-medial papillary muscle into the left ventricular assist device inflow cannula during diastole, causing low flows. This case highlights the importance of a systematic approach and use of multiple investigation modalities in making an accurate diagnosis. (Level of Difficulty: Advanced.).