RESUMO
AIMS: Sacral neuromodulation (SNM) is an advanced therapy option for the treatment of overactive bladder (OAB), nonobstructive urinary retention, and fecal incontinence. The aim of this ongoing prospective, multicenter, global, postmarket study is to confirm safety and clinical performance of the InterStimTM Micro system for SNM in all indications. Reported here are the results for the OAB cohort through 6-month follow-up. METHODS: Eligible OAB subjects that had a successful therapy evaluation were enrolled after implant of an InterStim Micro implantable pulse generator (IPG). Subjects completed voiding diaries and the Overactive Bladder Quality of Life questionnaire (OAB-q) at baseline and follow-up visits occurring at 3 months and 6 months postimplant. Safety was evaluated as device-, procedure-, or therapy-related adverse events. The primary objective for the OAB cohort was to demonstrate an improvement in OAB-q Health Related Quality of Life (HRQL) total score at 3 months postimplant compared to baseline. RESULTS: Sixty-eight OAB subjects were enrolled and implanted with an InterStim Micro IPG. Of those, 67 and 66 subjects completed the 3- and 6-month follow-up visits, respectively. The OAB-q HRQL demonstrated a statistically significant improvement from baseline to 3-month follow-up with an average increase of 33 ± 24 points (n = 67, p < 0.001). The change was also observed at 6-months with an average increase of 31 ± 23 points (n = 65) compared to baseline. Eighty-two percent of subjects achieved the minimally important difference in HRQL score at 3- and 6-month, respectively, with a change of 10 points or greater. The majority of subjects reported that their bladder condition was better at 3-month (92.5%, 62/67) and 6-month (89%, 59/66) compared to before they were treated with SNM therapy delivered by the InterStim Micro system. For subjects with urgency urinary incontinence (UUI), the average change from baseline to follow-up in UUI episodes/day was -3.6 (95% CI: -4.7, -2.6; n = 62) at 3-month and -3.7 (95% CI: -4.7, -2.7; n = 61) at 6-month. Among subjects with urgency-frequency (UF), the average change from baseline to follow up in voids/day was -4.5 (95% CI: -6.3, -2.7; n = 52) at 3-months and -4.4 (95% CI: -6.0, -2.7; n = 52) at 6-month. The cumulative incidence of device-, procedure-, or therapy- related adverse events was 7.4% (5/68). Out of these five related adverse events, there was one serious adverse event (1.5%, implant site pain) at the time of database snapshot. CONCLUSIONS: These data confirm the safety and clinical performance of the InterStim Micro device for subjects with OAB by demonstrating a significant improvement in OAB-q HRQL score at 3-month. Similar improvements were observed at 6 months in addition to an incidence of adverse events that is comparable to previously reported rates for SNM.
Assuntos
Bexiga Urinária Hiperativa , Incontinência Urinária , Humanos , Qualidade de Vida , Estudos Prospectivos , Resultado do Tratamento , Incontinência Urinária de UrgênciaRESUMO
Differentiating between complex renal cysts and cystic renal tumors is a difficult task that requires balancing unnecessary surgery with failure to diagnose cancer. We report a case of a Bosniak Class III renal mass removed by partial nephrectomy that was subsequently identified as an intrarenal supernumerary ovary. This report documents the rare anomaly of ectopic ovarian tissue and highlights the extraordinary combination of intrarenal location, lesion complexity, and surgical management with partial nephrectomy that makes this case unique.
Assuntos
Coristoma/cirurgia , Nefropatias/cirurgia , Nefrectomia/métodos , Ovário/anormalidades , Ovário/cirurgia , Adulto , Feminino , HumanosRESUMO
PURPOSE: We investigated whether infertility could be reversed in cryptorchid mice (with disrupted expression of the homeobox gene Hoxa 11) by orchiopexy and mating such animals with females of proven fertility. MATERIALS AND METHODS: Hoxa 11 mutant and WT male mice were genotyped by polymerase chain reaction. Surgery (orchiopexy or sham operation) was performed at age 18 days and fertility was assessed at ages 6 to 8 weeks. Animals were sacrificed at ages 6 to 9 months and computer assisted semen analysis was performed on fluid obtained by epididymal puncture. RESULTS: Five of 28 mutant mice proved fertile following orchiopexy versus 0 of 22 after sham operation (p <0.05). Values in WT mice were 18 of 35 and 25 of 33, respectively (p <0.01). Mean spermatozoa counts +/- SEM were 21.7 +/- 5.9 x 106/ml in 8 mutant mice with orchiopexy, 2.78 +/- 1.59 x 106/ml in 8 sham operated mutant mice (p <0.002), 15.6 +/- 4.9 x 106/ml in 7 WT mice with orchiopexy and 36.3 +/- 10.5 x 106/ml in 9 sham operated WT mice (p <0.02). CONCLUSIONS: Testicular position following orchiopexy is important to achieve fertility but the surgical procedure was associated with a degree of damage. Since mutant animals did not attain the fertility rates observed in WT animals following orchiopexy, other factors (possibly vaso-epididymal) may be necessary for normal spermatogenesis. Further studies of this model may allow the identification of such factors.