Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Sci Rep ; 11(1): 15600, 2021 08 02.
Artigo em Inglês | MEDLINE | ID: mdl-34341454

RESUMO

To assess the effectiveness and safety of the Preserflo Microshunt (PMS) implantation combined with cataract surgery in open-angle glaucoma (OAG) patients. Retrospective, open-label study conducted on insufficiently controlled OAG patients, who underwent a PMS implant procedure with mitomycin-C 0.2%, either alone or in combination with cataract surgery, and were followed for at least 12 months. Success was defined as an intraocular pressure (IOP) ≤ 18 mmHg and a reduction of at least 20% without (complete) or with (qualified) hypotensive medication. Fifty-eight eyes were included in the study, 35 eyes underwent PMS alone and 23 underwent PMS + Phaco. In the overall study sample, mean IOP was significantly lowered from 21.5 ± 3.3 mmHg at baseline to 14.6 ± 3.5 mmHg at month 12 (p < 0.0001). The IOP was significantly reduced in both groups; p < 0.0001 each, respectively. Ocular hypotensive medication was significantly reduced (p < 0.0001) in both groups. No significant differences were observed in IOP lowering or medication reduction between groups. At month 12, 62.1% eyes were considered as complete success and 82.8% eyes as qualified success. The most common adverse events were device close-to-endothelium, conjunctival fibrosis, and wound leakage. PMS, either alone or in combination with phacoemulsification, may be considered as a valuable option for treating OAG patients.


Assuntos
Extração de Catarata , Glaucoma de Ângulo Aberto/cirurgia , Implantação de Prótese , Idoso , Terapia Combinada , Feminino , Seguimentos , Glaucoma de Ângulo Aberto/fisiopatologia , Humanos , Pressão Intraocular , Estimativa de Kaplan-Meier , Masculino , Resultado do Tratamento
2.
Am J Ophthalmol ; 190: 191-196, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29649424

RESUMO

PURPOSE: To evaluate the safety and efficacy of supraciliary stenting following failed glaucoma surgery. DESIGN: Interventional case series. METHODS: Setting: Moorfields Eye Hospital, London, United Kingdom. STUDY POPULATION: Twenty eyes from 20 patients with glaucoma refractory to prior glaucoma surgery. INTERVENTION: Ab interno microstent (CyPass Micro-Stent; Alcon, Fort Worth, Texas, USA) implantation into the supraciliary space. MAIN OUTCOME MEASURES: Outcome measures included the occurrence of ocular adverse events, mean intraocular pressure (IOP) change, and glaucoma medication use through 12 months. RESULTS: Mean baseline IOP was 22.5 ± 8.0 mm Hg and number of medications was 2.7 ± 1.0. The majority of patients had undergone either prior trabeculectomy or aqueous shunt surgery. There were no serious intraoperative complications or major adverse events following supraciliary stenting. The most common adverse events included transient hyphema (3/20, 15%), transient IOP > 30 mm Hg (4/20, 20%), and transient IOP < 6 mm Hg (4/20, 20%). At 12 months, mean IOP was 14.9 ± 4.3 mm Hg-a 33.7% reduction (P = .01). Mean medication usage decreased 56% to 1.2 ± 1.5 at 12 months (P = .01). Two patients (10%) required subsequent aqueous shunt insertion. CONCLUSION: Ab interno supraciliary stenting has a favorable safety profile and provides an effective approach to controlling IOP and reducing medication burden in eyes in which previous glaucoma surgery has failed.


Assuntos
Câmara Anterior/cirurgia , Corpo Ciliar/cirurgia , Implantes para Drenagem de Glaucoma , Glaucoma de Ângulo Aberto/cirurgia , Implantação de Prótese/métodos , Stents , Adulto , Idoso , Anti-Hipertensivos/administração & dosagem , Espaço Extracelular , Feminino , Glaucoma de Ângulo Aberto/diagnóstico , Glaucoma de Ângulo Aberto/fisiopatologia , Gonioscopia , Humanos , Pressão Intraocular/fisiologia , Masculino , Pessoa de Meia-Idade , Facoemulsificação , Desenho de Prótese , Implantação de Prótese/efeitos adversos , Estudos Retrospectivos , Tonometria Ocular , Resultado do Tratamento , Acuidade Visual/fisiologia
3.
Can J Ophthalmol ; 53(3): 236-241, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29784159

RESUMO

OBJECTIVE: This study was designed to assess changes in corneal topography and biomechanics after intraocular pressure (IOP) monitoring using the Triggerfish contact lens sensor (CLS). METHODS: For this prospective study, 30 eyes of 30 subjects: 14 healthy subjects (G1) and 6 glaucoma patients (G2), were recruited for 24 hours of continuous IOP monitoring using the CLS. The following measurements were taken before CLS fitting and after lens removal: maximum keratometry (Kmax), mean keratometry (MK), and corneal astigmatism (Cyl) measured through Pentacam corneal topography, and the corneal biomechanical variables corneal hysteresis (CH) and corneal resistance factor (CRF) measured with the Ocular Response Analyzer (ORA). RESULTS: Pentacam data revealed significant changes after CLS removal in Kmax (+3.14 ± 2.46 D, p = 0.002), MK (+0.52 ± 0.63 D, p = 0.02), and Cyl (+0.48 ± 0.53 D, p = 0.019) in G1; and Kmax (+1.38 ± 1.43 D, p = 0.002) in G2. The changes observed were more pronounced in G1 than in G2 but differences were not significant. The ORA results indicated higher CH (11.35 ± 2.42 vs 8.17 ± 2.09) and CRF (10.3 ± 2.03 vs 9.1 ± 1.81) before lens fitting in G1 than G2, while no significant changes were produced after CLS removal in either group. CONCLUSIONS: The use of CLS for IOP monitoring over 24 hours caused topographic changes in both healthy subjects and glaucoma patients. No changes were produced in corneal biomechanics.


Assuntos
Lentes de Contato , Córnea/fisiopatologia , Glaucoma de Ângulo Aberto/fisiopatologia , Pressão Intraocular/fisiologia , Monitorização Fisiológica/instrumentação , Tonometria Ocular/instrumentação , Transdutores de Pressão , Adulto , Fenômenos Biomecânicos , Córnea/diagnóstico por imagem , Topografia da Córnea , Desenho de Equipamento , Feminino , Seguimentos , Glaucoma de Ângulo Aberto/diagnóstico , Humanos , Masculino , Estudos Prospectivos , Reprodutibilidade dos Testes , Adulto Jovem
4.
Eye (Lond) ; 32(8): 1338-1344, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29643463

RESUMO

PURPOSE: To compare the diagnostic performance of circumpapillary retinal nerve fiber layer (cpRNFL) analysis versus segmented ganglion cell complex analysis both by spectral-domain optical coherence tomography (SD-OCT) in children with primary congenital glaucoma (PCG). METHODS: Participants were 40 children diagnosed with PCG and 60 healthy children. Ophthalmological data collected (for one eye per child) were cup-disc ratio (C/D) and axial length (AL). SD-OCT with automated segmentation was used to measure the thicknesses and volumes of the macular retinal nerve fiber layer (mRNFL), ganglion cell layer (GCL), and inner plexiform layer (IPL). For the cpRNFL measurements conventional S-D OCT software was used and the capacity of each method to discriminate between normal and glaucomatous eyes was compared. RESULTS: Mean age was 11.20 ± 3.94 years for the glaucoma patients and 10.90 ± 2.46 years for controls (p = 0.64). All measurements were reduced (thinner) in the glaucoma group, significantly so for: cpRNFL, GCL, IPL and outer-superior and outer-inferior quadrant mRNFL. According to their areas under the receiver operating characteristics curve (AUC), temporal superior cpRNFL (0.869) and outer superior GCL (0.840), IPL (0.799), and mRNFL (0.767) showed the better diagnostic capacity. No differences were observed in AUCs for the most discriminatory cpRNFL and macular measurements. CONCLUSION: Segmented macular layer analysis shows a good capacity to discriminate between normal and glaucomatous eyes; which is comparable to that of cpRNFL analysis in children with PCG.


Assuntos
Glaucoma/diagnóstico , Pressão Intraocular/fisiologia , Disco Óptico/patologia , Células Ganglionares da Retina/patologia , Tomografia de Coerência Óptica/métodos , Criança , Estudos Transversais , Feminino , Glaucoma/congênito , Glaucoma/fisiopatologia , Humanos , Masculino , Fibras Nervosas/patologia , Curva ROC
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA