RESUMO
Radiotherapy in the head-and-neck area is one of the main curative treatment options. However, this comes at the cost of varying levels of normal tissue toxicity, affecting up to 80% of patients. Mucositis can cause pain, weight loss and treatment delays, leading to worse outcomes and a decreased quality of life. Therefore, there is an urgent need for an approach to predicting normal mucosal responses in patients prior to treatment. We here describe an assay to detect irradiation responses in healthy oral mucosa tissue. Mucosa specimens from the oral cavity were obtained after surgical resection, cut into thin slices, irradiated and cultured for three days. Seven samples were irradiated with X-ray, and three additional samples were irradiated with both X-ray and protons. Healthy oral mucosa tissue slices maintained normal morphology and viability for three days. We measured a dose-dependent response to X-ray irradiation and compared X-ray and proton irradiation in the same mucosa sample using standardized automated image analysis. Furthermore, increased levels of inflammation-inducing factors-major drivers of mucositis development-could be detected after irradiation. This model can be utilized for investigating mechanistic aspects of mucositis development and can be developed into an assay to predict radiation-induced toxicity in normal mucosa.
Assuntos
Mucosa Bucal , Humanos , Mucosa Bucal/efeitos da radiação , Raios X/efeitos adversos , Lesões por Radiação/etiologia , Lesões por Radiação/patologia , Masculino , Mucosite/etiologia , Mucosite/patologia , Feminino , Relação Dose-Resposta à Radiação , Estomatite/etiologia , Estomatite/patologia , Adulto , Pessoa de Meia-IdadeRESUMO
Perfusion MRI is promising for the assessment, prediction, and monitoring of radiation toxicity in organs at risk in head and neck cancer. Arterial spin labeling (ASL) may be an attractive alternative for conventional perfusion MRI, that does not require the administration of contrast agents. However, currently, little is known about the characteristics and performance of ASL in healthy tissues in the head and neck region. Therefore, the purpose of this study was to optimize and evaluate multidelay pseudocontinuous ASL (pCASL) for the head and neck region and to explore nominal values and measurement repeatability for the blood flow (BF), and the transit time and T1 values needed for BF quantification in healthy tissues. Twenty healthy volunteers underwent a scan session consisting of four repeats of multidelay pCASL (postlabel delays: 1000, 1632, 2479 ms). Regions of interest were defined in the parotid glands, submandibular glands, tonsils, and the cerebellum (as a reference). Nominal values of BF were calculated as the average over four repeats per volunteer. The repeatability coefficient and within-subject coefficient of repeatability (wCV) of BF were calculated. The effect of T1 (map vs. cohort average) and transit time correction on BF was investigated. The mean BF (± SE) was 55.7 ± 3.1 ml/100 g/min for the parotid glands, 41.2 ± 2.8 ml/100 g/min for the submandibular glands, and 32.3 ± 2.2 ml/100 g/min for the tonsils. The best repeatability was found in the parotid glands (wCV = 13.3%-16.1%), followed by the submandibular glands and tonsils (wCV = 20.0%-24.6%). On average, the effect of T1 and transit time correction on BF was limited, although substantial bias occurred in individual acquisitions. In conclusion, we demonstrated the feasibility of BF measurements in the head and neck region using multidelay pCASL and reported on nominal BF values, BF repeatability, the effect of T1, and transit time in various tissues in the head and neck region.
Assuntos
Neoplasias de Cabeça e Pescoço , Imageamento por Ressonância Magnética , Humanos , Marcadores de Spin , Artérias , Circulação Cerebrovascular/fisiologia , Encéfalo/irrigação sanguíneaRESUMO
BACKGROUND/PURPOSE: Post radiation mucosal ulcers (PRMU) after treatment for oropharyngeal squamous cell carcinoma (OPSCC) can have a huge negative impact on patients' quality of life, but little is known concerning risk factors and the impact of fraction size. Therefore, the goal of this study was to determine the pattern of PRMU development and to identify risk factors after a hypofractionated stereotactic body radiotherapy boost (SBRT) compared to conventionally fractionated radiotherapy for OPSCC. MATERIAL AND METHODS: We performed a retrospective cohort study (N = 332) of OPSCC patients with ≥ 1-year disease-free survival, treated with 46 Gy Intensity Modulated Radiotherapy (IMRT) (2 Gy fractions) followed by either an SBRT boost of 16.5 Gy (5.5 Gy fractions) (N = 180), or 24 Gy IMRT (2 Gy fractions) (N = 152). PRMU (grade ≥ 2) was scored when observed > three months after the last radiotherapy (RT) fraction (CTCAE v5.0). Potential risk factors were analyzed with Cox regression models using death as competing risk. Dose at the PRMU site was calculated by projecting delineated PRMU on the planning CT. RESULTS: All cases of PRMU (N = 64) occurred within 24 months; all were grade 2. The cumulative incidence at 2 years in the SBRT boost group was 26% (N = 46) vs. 12% (N = 18) for conventional fractionation (p = 0.003). Most PRMU developed within nine months (N = 48). PRMU occurring > nine months (N = 16) were mainly observed in the SBRT boost group (N = 15). Sex (p = 0.048), acute tube feeding (p = < 0.001), tumor subsite tonsil (p = 0.001), and N stage (p = 0.017) were associated with PRMU risk at multivariable regression in the hypofractionated SBRT boost group. All 25 delineated PRMU were located within the high dose regions. CONCLUSION: The risk of PRMU should be included in the cost benefit analysis when considering future research using a hypofractionated SBRT boost for OPSCC patients.
Assuntos
Carcinoma , Neoplasias Orofaríngeas , Radiocirurgia , Radioterapia de Intensidade Modulada , Humanos , Estudos Retrospectivos , Qualidade de Vida , Úlcera/etiologia , Fracionamento da Dose de Radiação , Radiocirurgia/efeitos adversos , Neoplasias Orofaríngeas/radioterapia , Neoplasias Orofaríngeas/etiologia , Radioterapia de Intensidade Modulada/efeitos adversos , Resultado do TratamentoRESUMO
PURPOSE: To optimize the diffusion-weighting b values and postprocessing pipeline for hybrid intravoxel incoherent motion diffusion kurtosis imaging in the head and neck region. METHODS: Optimized diffusion-weighting b value sets ranging between 5 and 30 b values were constructed by optimizing the Cramér-Rao lower bound of the hybrid intravoxel incoherent motion diffusion kurtosis imaging model. With this model, the perfusion fraction, pseudodiffusion coefficient, diffusion coefficient, and kurtosis were estimated. Sixteen volunteers were scanned with a reference b value set and 3 repeats of the optimized sets, of which 1 with volunteers swallowing on purpose. The effects of (1) b value optimization and number of b values, (2) registration type (none vs. intervolume vs. intra- and intervolume registration), and (3) manual swallowing artifact rejection on the parameter precision were assessed. RESULTS: The SD was higher in the reference set for perfusion fraction, diffusion coefficient, and kurtosis by a factor of 1.7, 1.5, and 2.3 compared to the optimized set, respectively. A smaller SD (factor 0.7) was seen in pseudodiffusion coefficient. The sets containing 15, 20, and 30 b values had comparable repeatability in all parameters, except pseudodiffusion coefficient, for which set size 30 was worse. Equal repeatability for the registration approaches was seen in all parameters of interest. Swallowing artifact rejection removed the bias when present. CONCLUSION: To achieve optimal hybrid intravoxel incoherent motion diffusion kurtosis imaging in the head and neck region, b value optimization and swallowing artifact image rejection are beneficial. The optimized set of 15 b values yielded the optimal protocol efficiency, with a precision comparable to larger b value sets and a 50% reduction in scan time.
Assuntos
Imagem de Difusão por Ressonância Magnética , Imagem de Tensor de Difusão , Artefatos , Humanos , Movimento (Física) , Reprodutibilidade dos TestesRESUMO
Background/purpose: To determine the efficacy and toxicity profile of a stereotactic body radiotherapy (SBRT) boost as a first line treatment in patients with oropharyngeal squamous cell carcinoma (OPSCC). Materials and methods: We performed a retrospective cohort study in 195 consecutive OPSCC patients with T1-small T3 disease, treated at Erasmus MC between 2009 and 2016 with a SBRT (3 × 5.5 Gy) boost after 46 Gy IMRT. Primary endpoints were disease-specific survival (DSS) and Grade ≥3 toxicity (Common Terminology Criteria). The Kaplan-Meier method and Cox regression model were applied to determine rates and risk factors. Results: The median follow-up was 4.3 years. Treatment compliance was high (100%). Rates of 5-year DSS and late grade ≥3 toxicity were 85% and 28%, respectively. Five-year overall survival was 67%. The most frequently observed toxicities were mucosal ulceration or soft tissue necrosis (n = 30, 5 year 18%), dysphagia or weight loss (n = 18, 5 year 12%) and osteoradionecrosis (n = 11, 5 year 9%). Current smoker status (hazard ratio [HR] = 2.9, p = .001) and Charlson Comorbidity Index ≥2 (HR = 1.9, p = .03) were was associated with increased toxicity risk. Tooth extraction prior to RT was associated with increased osteoradionecrosis risk (HR = 6.4, p = .006). Conclusion: We reported on outcomes in the largest patient series to date treated with a hypofractionated boost for OPSCC. Efficacy was good with survival rates comparable to conventionally fractionated (chemo)radiotherapy. Grade ≥3 toxicity profiles showed high rates of soft tissue necrosis and osteoradionecrosis. Strategies to mitigate severe toxicity risks are under investigation to improve the tolerability of the SBRT boost.
Assuntos
Carcinoma de Células Escamosas/mortalidade , Fracionamento da Dose de Radiação , Neoplasias Orofaríngeas/mortalidade , Radiocirurgia/mortalidade , Adulto , Idoso , Idoso de 80 Anos ou mais , Carcinoma de Células Escamosas/patologia , Carcinoma de Células Escamosas/cirurgia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Neoplasias Orofaríngeas/patologia , Neoplasias Orofaríngeas/cirurgia , Prognóstico , Estudos Retrospectivos , Taxa de SobrevidaRESUMO
PURPOSE: To develop a fully automated procedure for multicriterial volumetric modulated arc therapy (VMAT) treatment planning (autoVMAT) for stage III/IV non-small cell lung cancer (NSCLC) patients treated with curative intent. MATERIALS AND METHODS: After configuring the developed autoVMAT system for NSCLC, autoVMAT plans were compared with manually generated clinically delivered intensity-modulated radiotherapy (IMRT) plans for 41 patients. AutoVMAT plans were also compared to manually generated VMAT plans in the absence of time pressure. For 16 patients with reduced planning target volume (PTV) dose prescription in the clinical IMRT plan (to avoid violation of organs at risk tolerances), the potential for dose escalation with autoVMAT was explored. RESULTS: Two physicians evaluated 35/41 autoVMAT plans (85%) as clinically acceptable. Compared to the manually generated IMRT plans, autoVMAT plans showed statistically significant improved PTV coverage (V95% increased by 1.1% ± 1.1%), higher dose conformity (R50 reduced by 12.2% ± 12.7%), and reduced mean lung, heart, and esophagus doses (reductions of 0.9 Gy ± 1.0 Gy, 1.5 Gy ± 1.8 Gy, 3.6 Gy ± 2.8 Gy, respectively, all p < 0.001). To render the six remaining autoVMAT plans clinically acceptable, a dosimetrist needed less than 10 min hands-on time for fine-tuning. AutoVMAT plans were also considered equivalent or better than manually optimized VMAT plans. For 6/16 patients, autoVMAT allowed tumor dose escalation of 5-10 Gy. CONCLUSION: Clinically deliverable, high-quality autoVMAT plans can be generated fully automatically for the vast majority of advanced-stage NSCLC patients. For a subset of patients, autoVMAT allowed for tumor dose escalation.
Assuntos
Carcinoma Pulmonar de Células não Pequenas/patologia , Carcinoma Pulmonar de Células não Pequenas/radioterapia , Neoplasias Pulmonares/patologia , Neoplasias Pulmonares/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Algoritmos , Humanos , Estadiamento de Neoplasias , Órgãos em Risco/efeitos da radiação , Dosagem Radioterapêutica , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Software , Resultado do Tratamento , Carga Tumoral/efeitos da radiação , Interface Usuário-ComputadorRESUMO
BACKGROUND: Proton therapy is becoming increasingly available, so it is important to apply objective and individualized patient selection to identify those who are expected to benefit most from proton therapy compared to conventional intensity modulated radiation therapy (IMRT). Comparative treatment planning using normal tissue complication probability (NTCP) evaluation has recently been proposed. This work investigates the impact of NTCP model and dose uncertainties on model-based patient selection. MATERIAL AND METHODS: We used IMRT and intensity modulated proton therapy (IMPT) treatment plans of 78 oropharyngeal cancer patients, which were generated based on automated treatment planning and evaluated based on three published NTCP models. A reduction in NTCP of more than a certain threshold (e.g. 10% lower NTCP) leads to patient selection for IMPT, referred to as 'nominal' selection. To simulate the effect of uncertainties in NTCP-model coefficients (based on reported confidence intervals) and planned doses on the accuracy of model-based patient selection, the Monte Carlo method was used to sample NTCP-model coefficients and doses from a probability distribution centered at their nominal values. Patient selection accuracy within a certain sample was defined as the fraction of patients which had similar selection in both the 'nominal' and 'sampled' scenario. RESULTS: For all three NTCP models, the median patient selection accuracy was found to be above 70% when only NTCP-model uncertainty was considered. Selection accuracy decreased with increasing uncertainty resulting from differences between planned and delivered dose. In case of excessive dose uncertainty, selection accuracy decreased to 60%. CONCLUSION: Model and dose uncertainty highly influence the accuracy of model-based patient selection for proton therapy. A reduction of NTCP-model uncertainty is necessary to reach more accurate model-based patient selection.
Assuntos
Método de Monte Carlo , Órgãos em Risco/efeitos da radiação , Neoplasias Orofaríngeas/radioterapia , Terapia com Prótons , Planejamento da Radioterapia Assistida por Computador/métodos , Idoso , Relação Dose-Resposta à Radiação , Feminino , Humanos , Masculino , IncertezaRESUMO
Objective. Increasing cancer incidence, staff shortage and high burnout rate among radiation oncologists, medical physicists and radiation technicians are putting many departments under strain. Operations research (OR) tools could optimize radiotherapy processes, however, clinical implementation of OR-tools in radiotherapy is scarce since most investigated optimization methods lack robustness against patient-to-patient variation in duration of tasks. By combining OR-tools, a method was developed that optimized deployment of radiotherapy resources by generating robust pretreatment preparation schedules that balance the expected average patient preparation time (Fmean) with the risk of working overtime (RoO). The method was evaluated for various settings of an one-stop shop (OSS) outpatient clinic for palliative radiotherapy.Approach. The OSS at our institute sees, scans and treats 3-5 patients within one day. The OSS pretreatment preparation workflow consists of a fixed sequence of tasks, which was manually optimized for radiation oncologist and CT availability. To find more optimal sequences, with shorterFmeanand lowerRoO, a genetic algorithm was developed which regards these sequences as DNA-strands. The genetic algorithm applied natural selection principles to produce new sequences. A decoder translated sequences to schedules to find the conflicting fitness parametersFmeanandRoO. For every generation, fitness of sequences was determined by the distance to the estimated Pareto front ofFmeanandRoO. Experiments were run in various OSS-settings.Main results. According to our approach, the expectedFmeanof the current clinical schedule could be reduced with 37%, without increasingRoO. Additional experiments provided insights in trade-offs betweenFmean,RoO, working shift length, number of patients treated on a single day and staff composition.Significance. Our approach demonstrated that OR-tools could optimize radiotherapy resources by robust pretreatment workflow scheduling. The results strongly support further exploration of scheduling optimization for treatment preparation also outside a one-stop shop or radiotherapy setting.
Assuntos
Neoplasias , Planejamento da Radioterapia Assistida por Computador , Humanos , Planejamento da Radioterapia Assistida por Computador/métodos , Fluxo de Trabalho , Neoplasias/radioterapia , Dosagem RadioterapêuticaRESUMO
Human papillomavirus (HPV) is an important risk factor for oropharyngeal squamous cell carcinoma (OPSCC). HPV-positive (HPV+) cases are associated with a different pathophysiology, microstructure, and prognosis compared to HPV-negative (HPV-) cases. This review aimed to investigate the potential of magnetic resonance imaging (MRI) to discriminate between HPV+ and HPV- tumours and predict HPV status in OPSCC patients. A systematic literature search was performed on 15 December 2022 on EMBASE, MEDLINE ALL, Web of Science, and Cochrane according to PRISMA guidelines. Twenty-eight studies (n = 2634 patients) were included. Five, nineteen, and seven studies investigated structural MRI (e.g., T1, T2-weighted), diffusion-weighted MRI, and other sequences, respectively. Three out of four studies found that HPV+ tumours were significantly smaller in size, and their lymph node metastases were more cystic in structure than HPV- ones. Eleven out of thirteen studies found that the mean apparent diffusion coefficient was significantly higher in HPV- than HPV+ primary tumours. Other sequences need further investigation. Fourteen studies used MRI to predict HPV status using clinical, radiological, and radiomics features. The reported areas under the curve (AUC) values ranged between 0.697 and 0.944. MRI can potentially be used to find differences between HPV+ and HPV- OPSCC patients and predict HPV status with reasonable accuracy. Larger studies with external model validation using independent datasets are needed before clinical implementation.
RESUMO
PURPOSE: One-table treatments with treatment imaging, preparation and delivery occurring at one treatment couch, could increase patients' comfort and throughput for palliative treatments. On regular C-arm linacs, however, cone-beam CT (CBCT) imaging quality is currently insufficient. Therefore, our goal was to assess the suitability of AI-generated CBCT based synthetic CT (sCT) images for target delineation and treatment planning for palliative radiotherapy. MATERIALS AND METHODS: CBCTs and planning CT-scans of 22 female patients with pelvic bone metastasis were included. For each CBCT, a corresponding sCT image was generated by a deep learning model in ADMIRE 3.38.0. Radiation oncologists delineated 23 target volumes (TV) on the sCTs (TVsCT) and scored their delineation confidence. The delineations were transferred to planning CTs and manually adjusted if needed to yield gold standard target volumes (TVclin). TVsCT were geometrically compared to TVclin using Dice coefficient (DC) and Hausdorff Distance (HD). The dosimetric impact of TVsCT inaccuracies was evaluated for VMAT plans with different PTV margins. RESULTS: Radiation oncologists scored the sCT quality as sufficient for 13/23 TVsCT (median: DC = 0.9, HD = 11 mm) and insufficient for 10/23 TVsCT (median: DC = 0.7, HD = 34 mm). For the sufficient category, remaining inaccuracies could be compensated by +1 to +4 mm additional margin to achieve coverage of V95% > 95% and V95% > 98%, respectively in 12/13 TVsCT. CONCLUSION: The evaluated sCT quality allowed for accurate delineation for most targets. sCTs with insufficient quality could be identified accurately upfront. A moderate PTV margin expansion could address remaining delineation inaccuracies. Therefore, these findings support further exploration of CBCT based one-table treatments on C-arm linacs.
Assuntos
Ossos Pélvicos , Tomografia Computadorizada de Feixe Cônico Espiral , Humanos , Feminino , Cuidados Paliativos , Pelve , Tomografia Computadorizada por Raios X , Tomografia Computadorizada de Feixe Cônico/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Dosagem RadioterapêuticaRESUMO
Objective. Newer cone-beam computed tomography (CBCT) imaging systems offer reconstruction algorithms including metal artifact reduction (MAR) and extended field-of-view (eFoV) techniques to improve image quality. In this study a new CBCT imager, the new Varian HyperSight CBCT, is compared to fan-beam CT and two CBCT imagers installed in a ring-gantry and C-arm linear accelerator, respectively.Approach. The image quality was assessed for HyperSight CBCT which uses new hardware, including a large-size flat panel detector, and improved image reconstruction algorithms. The decrease of metal artifacts was quantified (structural similarity index measure (SSIM) and root-mean-squared error (RMSE)) when applying MAR reconstruction and iterative reconstruction for a dental and spine region using a head-and-neck phantom. The geometry and CT number accuracy of the eFoV reconstruction was evaluated outside the standard field-of-view (sFoV) on a large 3D-printed chest phantom. Phantom size dependency of CT numbers was evaluated on three cylindrical phantoms of increasing diameter. Signal-to-noise and contrast-to-noise were quantified on an abdominal phantom.Main results. In phantoms with streak artifacts, MAR showed comparable results for HyperSight CBCT and CT, with MAR increasing the SSIM (0.97-0.99) and decreasing the RMSE (62-55 HU) compared to iterative reconstruction without MAR. In addition, HyperSight CBCT showed better geometrical accuracy in the eFoV than CT (Jaccard Conformity Index increase of 0.02-0.03). However, the CT number accuracy outside the sFoV was lower than for CT. The maximum CT number variation between different phantom sizes was lower for the HyperSight CBCT imager (â¼100 HU) compared to the two other CBCT imagers (â¼200 HU), but not fully comparable to CT (â¼50 HU).Significance. This study demonstrated the imaging performance of the new HyperSight CBCT imager and the potential of applying this CBCT system in more advanced scenarios by comparing the quality against fan-beam CT.
Assuntos
Tomografia Computadorizada de Feixe Cônico , Processamento de Imagem Assistida por Computador , Imagens de Fantasmas , Tomografia Computadorizada de Feixe Cônico/instrumentação , Tomografia Computadorizada de Feixe Cônico/métodos , Processamento de Imagem Assistida por Computador/métodos , Humanos , Artefatos , Controle de QualidadeRESUMO
Objectives: Patients with head and neck cancer are routinely screened for dental foci prior to radiotherapy (RT) to prevent post- RT tooth extractions associated with an increased risk of osteoradionecrosis. We evaluated the risk factors for post-RT tooth extraction to personalise dental screening and prevention protocols prior to RT. Materials and methods: This retrospective cohort study included dentulous patients diagnosed with oropharyngeal cancer who had undergone radiation therapy at doses 60-70 Gy and achieved a disease-free survival of ≥ 1 year (N = 174). Risk factors were assessed using Cox regression models. Results: The cumulative incidence of post-RT tooth extraction was 30.7 % at 5 years. Main indications for extraction (n = 62) were radiation caries (n = 20) and periodontal disease (n = 27). Risk factors associated (p < 0.05) with radiation caries-related extractions included active smoking, alcohol abuse, poor oral hygiene, parotid gland irradiation, and mandibular irradiation. A high-dose volume in the mandible was associated with periodontal disease events. Conclusion: Post-RT extractions due to radiation caries were influenced by lifestyle factors and RT dose in the mandible and parotid glands. Periodontal disease-related extractions were primarily associated with the mandibular dose. During dental screening these post-RT risk factors should be taken into account to prevent osteoradionecrosis.
RESUMO
Background and purpose: Diffusion-weighted imaging (DWI) is a promising technique for response assessment in head-and-neck cancer. Recently, we optimized Non-Gaussian Intravoxel Incoherent Motion Imaging (NG-IVIM), an extension of the conventional apparent diffusion coefficient (ADC) model, for the head and neck. In the current study, we describe the first application in a group of patients with human papillomavirus (HPV)-positive and HPV-negative oropharyngeal squamous cell carcinoma. The aim of this study was to relate ADC and NG-IVIM DWI parameters to HPV status and clinical treatment response. Materials and methods: Thirty-six patients (18 HPV-positive, 18 HPV-negative) were prospectively included. Presence of progressive disease was scored within one year. The mean pre-treatment ADC and NG-IVIM parameters in the gross tumor volume were compared between HPV-positive and HPV-negative patients. In HPV-negative patients, ADC and NG-IVIM parameters were compared between patients with and without progressive disease. Results: ADC, the NG-IVIM diffusion coefficient D, and perfusion fraction f were significantly higher, while pseudo-diffusion coefficient D* and kurtosis K were significantly lower in the HPV-negative compared to HPV-positive patients. In the HPV-negative group, a significantly lower D was found for patients with progressive disease compared to complete responders. No relation with ADC was observed. Conclusion: The results of our single-center study suggest that ADC is related to HPV status, but not an independent response predictor. The NG-IVIM parameter D, however, was independently associated to response in the HPV-negative group. Noteworthy in the opposite direction as previously thought based on ADC.
RESUMO
The European SocieTy for Radiotherapy and Oncology (ESTRO) organized a one-year pilot mentoring programme. At evaluation after one year, both mentors and mentees scored the programme with a median score of 9 on a scale of 10. All of the mentors indicated that they wanted to participate again as mentors.
Assuntos
Tutoria , Radioterapia (Especialidade) , Sociedades Médicas , Humanos , Projetos Piloto , Radioterapia (Especialidade)/educação , Europa (Continente) , Oncologia/educação , Mentores , Avaliação de Programas e Projetos de SaúdeRESUMO
BACKGROUND AND PURPOSE: The recently introduced high-performance CBCT imaging system called HyperSight offers improved Hounsfield units (HU) accuracy, a larger CBCT field-of-view and improved image quality compared to conventional ring gantry CBCT, possibly enabling treatment planning on CBCT imaging directly. In this study, we evaluated whether the dose calculation accuracy on HyperSight CBCT was sufficient for treatment planning in prostate and lung cancer patients. MATERIALS AND METHODS: HyperSight CBCT was compared to planning CT (pCT) in terms of HU-to-mass density (MD) calibration curves. For twenty prostate patients and twenty lung patients, differences in DVH parameters, and 3D global gamma between dose distributions calculated on pCT and free breathing HyperSight CBCT were evaluated. For this purpose, HyperSight CBCT acquired at the first fraction was rigidly registered to the pCT, delineations from the CT were propagated and the dose was recalculated on the HyperSight CBCT. RESULTS: For each insert of the HU-to-MD calibration phantom, the HU values of HyperSight CBCT and pCT agreed within 35 HU. For prostate maximum deviations in PTV Dmean, V95% and V107% were 1.8 %, -1.1 % and < 0.1 % respectively. For lung PTV V95% was generally lower (median -1.1 %) and PTV V107% was generally higher (median 1.1 %) on HyperSight CBCT due to breathing motion artifacts. The average (±SD) 2 %/2mm gamma pass rate was 98.7 %±1.2 % for prostate cancer patients and 96.2 %±2.1 % for lung cancer patients. CONCLUSION: HyperSight CBCT enabled accurate dose calculation for prostate cancer patients, without implementation of a specific HyperSight CBCT-to-MD curve. For lung cancer patients, breathing motion hampered accurate dose calculations.
RESUMO
BACKGROUND AND PURPOSE: A novel Cone-Beam Computed Tomography (CBCT) named HyperSight provides superior CBCT image quality compared to conventional ring gantry CBCT imaging, and it is suitable for dose calculations for prostate cancer, but it comes with considerable additional costs. The aim of this study was to determine the added value of HyperSight CBCT imaging compared to conventional CBCT imaging in terms of organ visibility in the male pelvic region. MATERIALS AND METHODS: Twenty prostate cancer patients were included in this prospective clinical study. For each patient three CBCT pairs, consisting of HyperSight and conventional CBCT scans acquired on consecutive days, were included. CBCT scans were evaluated by four observers in terms of visibility of the prostate, bladder, rectum and seminal vesicles. Visibility was scored on a 1-to-5 scale and by annotating axial slices where the organs were hard to delineate. Lastly, observers indicated whether the CBCT scans were of sufficient quality for an online adaptive radiation therapy workflow. RESULTS: All four organs were better visible on HyperSight CBCT scans compared to conventional CBCT scans. The mean visibility scores increased from 3.1 to 4.5 on a 1--5 scale of and the mean number of annotated slices reduced from 4.5 to 1.1. 99% Of the HyperSight CBCT scans were considered suitable for an online adaptive workflow vs 25-83% for the conventional CBCT scans. CONCLUSION: HyperSight CBCT scans yielded a visibility of prostate, bladder, rectum and seminal vesicles comparable to planning CT scans and, can replace a repeat planning CT scan in case of anatomical changes requiring a new treatment plan.
Assuntos
Tomografia Computadorizada de Feixe Cônico , Neoplasias da Próstata , Humanos , Masculino , Tomografia Computadorizada de Feixe Cônico/métodos , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Estudos Prospectivos , Idoso , Pessoa de Meia-Idade , Reto/diagnóstico por imagem , Bexiga Urinária/diagnóstico por imagem , Planejamento da Radioterapia Assistida por Computador/métodos , Glândulas Seminais/diagnóstico por imagemRESUMO
PURPOSE: Osteoradionecrosis (ORN) of the mandible is a severe complication following radiotherapy of the head and neck, but not all regions of the mandible may be equally at risk. Therefore our goal was to explore a local dose response relationship for subregions of the mandible. MATERIALS AND METHODS: All oropharyngeal cancer patients treated at our hospital between 2009 and 2016 were reviewed. Follow-up was cut-off at 3 years. For patients that developed ORN, the ORN volume was delineated on the planning CT. Each mandible was divided into 16 volumes of interest (VOIs) based on the location of the dental elements and the presence of ORN in each was scored. Generalized estimating equations were used to build a model for the probability of developing ORN in an element VOI. RESULTS: Of the 219 included patients, 22 developed ORN in 89 element VOIs. Mean dose to the element VOI (odds ratio (OR) = 1.05 per Gy, 95% confidence interval (CI): (1.04,1.07)), pre-radiotherapy extractions of an element ipsilateral to element of interest (OR = 2.81, 95% CI: (1.12,7.05)), and smoking at start of radiotherapy (OR = 3.37, 95% CI: (1.29,8.78)) were significantly associated with an increased probability of ORN in the VOI. CONCLUSION: The developed dose-response model indicates that the probability of ORN varies within the mandible and strongly depends on the local dose, the location of extractions, and smoking.
Assuntos
Neoplasias de Cabeça e Pescoço , Neoplasias Orofaríngeas , Osteorradionecrose , Humanos , Dosagem Radioterapêutica , Osteorradionecrose/etiologia , Neoplasias Orofaríngeas/radioterapia , Fumar , Mandíbula , Neoplasias de Cabeça e Pescoço/radioterapia , Estudos RetrospectivosRESUMO
Objective. In MR-only clinical workflow, replacing CT with MR image is of advantage for workflow efficiency and reduces radiation to the patient. An important step required to eliminate CT scan from the workflow is to generate the information provided by CT via an MR image. In this work, we aim to demonstrate a method to generate accurate synthetic CT (sCT) from an MR image to suit the radiation therapy (RT) treatment planning workflow. We show the feasibility of the method and make way for a broader clinical evaluation.Approach. We present a machine learning method for sCT generation from zero-echo-time (ZTE) MRI aimed at structural and quantitative accuracies of the image, with a particular focus on the accurate bone density value prediction. The misestimation of bone density in the radiation path could lead to unintended dose delivery to the target volume and results in suboptimal treatment outcome. We propose a loss function that favors a spatially sparse bone region in the image. We harness the ability of the multi-task network to produce correlated outputs as a framework to enable localization of region of interest (RoI) via segmentation, emphasize regression of values within RoI and still retain the overall accuracy via global regression. The network is optimized by a composite loss function that combines a dedicated loss from each task.Main results. We have included 54 brain patient images in this study and tested the sCT images against reference CT on a subset of 20 cases. A pilot dose evaluation was performed on 9 of the 20 test cases to demonstrate the viability of the generated sCT in RT planning. The average quantitative metrics produced by the proposed method over the test set were-(a) mean absolute error (MAE) of 70 ± 8.6 HU; (b) peak signal-to-noise ratio (PSNR) of 29.4 ± 2.8 dB; structural similarity metric (SSIM) of 0.95 ± 0.02; and (d) Dice coefficient of the body region of 0.984 ± 0.Significance. We demonstrate that the proposed method generates sCT images that resemble visual characteristics of a real CT image and has a quantitative accuracy that suits RT dose planning application. We compare the dose calculation from the proposed sCT and the real CT in a radiation therapy treatment planning setup and show that sCT based planning falls within 0.5% target dose error. The method presented here with an initial dose evaluation makes an encouraging precursor to a broader clinical evaluation of sCT based RT planning on different anatomical regions.
Assuntos
Processamento de Imagem Assistida por Computador , Aprendizado de Máquina , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Dosagem RadioterapêuticaRESUMO
Purpose: The aim of this article is to establish a comprehensive contouring guideline for treatment planning using only magnetic resonance images through an up-to-date set of organs at risk (OARs), recommended organ boundaries, and relevant suggestions for the magnetic resonance imaging (MRI)-based delineation of OARs in the head and neck (H&N) region. Methods and Materials: After a detailed review of the literature, MRI data were collected from the H&N region of healthy volunteers. OARs were delineated in the axial, coronal, and sagittal planes on T2-weighted sequences. Every contour defined was revised by 4 radiation oncologists and subsequently by 2 independent senior experts (H&N radiation oncologist and radiologist). After revision, the final structures were presented to the consortium partners. Results: A definitive consensus was reached after multi-institutional review. On that basis, we provided a detailed anatomic and functional description and specific MRI characteristics of the OARs. Conclusions: In the era of precision radiation therapy, the need for well-built, straightforward contouring guidelines is on the rise. Precise, uniform, delineation-based, automated OAR segmentation on MRI may lead to increased accuracy in terms of organ boundaries and analysis of dose-dependent sequelae for an adequate definition of normal tissue complication probability.
RESUMO
PURPOSE: Organizational culture plays a major role in prioritizing diversity, equity, and inclusion (DEI) objectives by aligning individual values of employees with organizational values. However, effective strategies to create an inclusive organizational culture, in which these values are aligned, remain unclear. The European Society for Radiotherapy and Oncology (ESTRO) launched a qualitative study, as a follow-up of the previous project on DEI that highlighted low levels of inclusion and work engagement among radiation oncology (RO) professionals in Europe. The aim of the present study was to gain an understanding of how DEI could be improved within RO departments by creating a more inclusive organizational culture. METHODS AND MATERIALS: A qualitative research study was conducted by enrolling RO professionals from 4 selected European countries through an open call on the ESTRO platform. Respondents who completed an online survey and met the inclusion criteria, such as experiencing low DEI levels at work, were invited for an online semistructured interview. Interview transcripts were analyzed thematically with an abductive approach via concepts in relation to "DEI," "work engagement," "organizational culture," and "professional values." RESULTS: Twenty-six eligible respondents from Great Britain, Italy, Poland, and Switzerland were interviewed. The thematic analysis identified cases in which limited engagement at work emerged when the personal values of RO professionals conflicted with dominant organizational values, hampering DEI. Three conflicts were found between the following personal versus organizational values: (1) self-development versus efficiency, (2) togetherness versus competition, and (3) people-oriented versus task-oriented cultures. CONCLUSIONS: Awareness of how organizational values can conflict with professionals' values should be raised to improve inclusion and engagement in the workplace. Additionally, efforts should be focused on tackling existing power imbalances that hamper effective deliberation on organizational- versus personal-value conflicts.