Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 37
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38940255

RESUMO

INTRODUCTION: Gliflozins are recommended as first-line treatment in patients with heart failure and/or cardiovascular comorbidities and are demonstrated to reduce atrial fibrillation (AF) occurrence. However, it is not well known which gliflozin yields the larger cardioprotection in terms of AF occurrence reduction. Hence, we aimed to compare data regarding AF recurrence associated with different gliflozins. METHODS: An accurate search of online scientific libraries (from inception to June 1, 2023) was performed. Fifty-nine studies were included in the meta-analysis involving 108 026 patients, of whom 60 097 received gliflozins and 47 929 received placebo. RESULTS: Gliflozins provided a statistically significant reduction of AF occurrence relative to standard of care therapy in the overall population (relative risks [RR]: 0.8880, 95% CI: [0.8059; 0.9784], p = .0164) and in patients with diabetes and cardiorenal diseases (RR: 0.8352, 95% CI: [0.7219; 0.9663], p = .0155). Dapagliflozin significantly decreased AF occurrence as compared to placebo (0.7259 [0.6337; 0.8316], p < .0001) in the overall population, in patients with diabetes (RR: 0.2482, 95% CI: [0.0682; 0.9033], p = .0345), with diabetes associated with cardiorenal diseases (RR: 0.7192, 95% CI: [0.5679; 0.9110], p = .0063) and in the subanalysis including studies with follow-up ≥1 year (RR: 0.7792, 95% CI: [0.6508; 0.9330], p = .0066). No significant differences in terms of AF protection were found among different gliflozins. CONCLUSIONS: Dapagliflozin use was associated with significant reduction in AF risk as compared to placebo in overall population and patients with diabetes, whereas the use of other gliflozins did not significantly reduce AF occurrence.

2.
Medicina (Kaunas) ; 60(1)2024 Jan 03.
Artigo em Inglês | MEDLINE | ID: mdl-38256355

RESUMO

Pediatric cardiomyopathies (CMs) and electrical diseases constitute a heterogeneous spectrum of disorders distinguished by structural and electrical abnormalities in the heart muscle, attributed to a genetic variant. They rank among the main causes of morbidity and mortality in the pediatric population, with an annual incidence of 1.1-1.5 per 100,000 in children under the age of 18. The most common conditions are dilated cardiomyopathy (DCM) and hypertrophic cardiomyopathy (HCM). Despite great enthusiasm for research in this field, studies in this population are still limited, and the management and treatment often follow adult recommendations, which have significantly more data on treatment benefits. Although adult and pediatric cardiac diseases share similar morphological and clinical manifestations, their outcomes significantly differ. This review summarizes the latest evidence on genetics, clinical characteristics, management, and updated outcomes of primary pediatric CMs and electrical diseases, including DCM, HCM, arrhythmogenic right ventricular cardiomyopathy (ARVC), Brugada syndrome (BrS), catecholaminergic polymorphic ventricular tachycardia (CPVT), long QT syndrome (LQTS), and short QT syndrome (SQTS).


Assuntos
Cardiomiopatia Dilatada , Cardiomiopatia Hipertrófica , Cardiopatias , Síndrome do QT Longo , Adulto , Criança , Humanos , Arritmias Cardíacas/epidemiologia , Arritmias Cardíacas/genética , Coração , Cardiomiopatia Dilatada/epidemiologia , Cardiomiopatia Dilatada/genética
3.
Pacing Clin Electrophysiol ; 45(4): 519-531, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35147225

RESUMO

BACKGROUND: Catheter ablation of papillary muscle ventricular arrhythmias (PM-VAs) has been associated with unsatisfactory results. Features that may affect acute and long-term procedural outcomes are not well established. OBJECTIVE: To systematically review the available data in the literature assessing efficacy and safety of PM-VAs catheter ablation. METHODS: An online search of PubMed, Cochrane Registry, Web of Science, Scopus and EMBASE libraries (from inception to March 1, 2021) was performed, in addition to manual screening. Twenty-one observational noncontrolled case-series were considered eligible for the systematic review, including 536 patients. RESULTS: Postero-medial PM harbored 60.8% of PM-VAs, while antero-lateral PM and right ventricular PMs 34.9% and 4.3% of cases, respectively. The mean acute success rate of the index ablation procedure was 88.1% (95% CI 82.8% to 91.9%, p < .001, I2 0%). After a mean follow-up period of 15.5 ± 17.4 months, pooled long-term arrhythmia-free rate was 69.2%, while the pooled long-term success rate after multiple ablation procedure was 84.9%. Overall, procedure complications occurred in nine patients (1.7%) and no procedure-related deaths were reported. The use of intracardiac echocardiography (ICE) as well as contact force sensing (CFS) and irrigated catheters during ablation was associated with higher rates of arrhythmia-freedom at long-term follow-up. CONCLUSIONS: Catheter ablation is an effective and safe strategy for PM-VAs, with an acute success rate of 88.1%, a long-term success rate of 69.2%, with a relatively low procedural complication rate. The use of ICE, irrigated catheters and catheters with CFS capability was associated with higher rates of arrhythmia-freedom at long-term follow-up.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Complexos Ventriculares Prematuros , Ablação por Cateter/métodos , Ventrículos do Coração , Humanos , Músculos Papilares/cirurgia , Resultado do Tratamento
4.
Medicina (Kaunas) ; 58(11)2022 Oct 24.
Artigo em Inglês | MEDLINE | ID: mdl-36363470

RESUMO

Atrial fibrillation (AF) is the most frequent chronic arrhythmia worldwide, and it is associated with significant morbidity and mortality, making it a considerable burden both to patients and the healthcare system. Nowadays, an early attempt to restore sinus rhythm in acute symptomatic AF through electrical or pharmacological cardioversion is the most common approach in the Emergency Department (ED). However, considering the high percentage of spontaneous cardioversion of paroxysmal AF reported by many studies, this approach may not be the ideal choice for all patients. In this manuscript we performed a review of the most relevant studies found in literature with the aim of identifying the main determinants of spontaneous cardioversion, focusing on those easy to detect in the ED. We have found that the most relevant predictors of spontaneous cardioversion are the absence of Heart Failure (HF), a small atrial size, recent-onset AF, rapid Atrial Fibrillatory Rate and the relationship between a previous AF episode and Heart Rate/Blood Pressure. A number of those are utilized, along with other easily determined parameters, in the recently developed "ReSinus" score which predicts the likelihood of AF spontaneous cardioversion. Such identification may help the physician decide whether immediate cardioversion is necessary, or whether to adopt a "watch-and-wait" strategy in the presence of spontaneous cardioversion determinants.


Assuntos
Fibrilação Atrial , Cardioversão Elétrica , Humanos , Fibrilação Atrial/complicações , Antiarrítmicos/uso terapêutico , Incidência , Átrios do Coração
5.
J Cardiovasc Electrophysiol ; 32(5): 1296-1304, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33783875

RESUMO

BACKGROUND: No data exist on the ability of the novel Rhythmia 3-D mapping system to minimize fluoroscopy exposure during transcatheter ablation of arrhythmias. We report data on the feasibility and safety of a minimal fluoroscopic approach using this system in supraventricular tachycardia (SVT) procedures. METHODS: Consecutive patients were enrolled in the CHARISMA registry at 12 centers. All right-sided procedures performed with the Rhythmia mapping system were analyzed. The acquired electroanatomic information was used to reconstruct 3-D cardiac geometry; fluoroscopic confirmation was used whenever deemed necessary. RESULTS: Three hundred twenty-five patients (mean age = 56 ± 17 years, 57% male) were included: 152 atrioventricular nodal reentrant tachycardia, 116 atrial flutter, 41 and 16 right-sided accessory pathway and atrial tachycardia, respectively. Overall, 27 481 s of fluoroscopy were used (84.6 ± 224 s per procedure, equivalent effective dose = 1.1 ± 3.7 mSv per patient). One hundred ninety-two procedures (59.1%) were completed without the use of fluoroscopy (zero fluoroscopy, ZF). In multivariate analysis, the presence of a fellow in training (OR = 0.15, 95% CI: 0.05-0.46; p = .0008), radiofrequency application (0.99, 0.99-1.00; p = .0002), and mapping times (0.99, 0.99-1.00; p = .042) were all inversely associated with ZF approach. Acute procedural success was achieved in 97.8% of the cases (98.4 vs. 97% in the ZF vs. non-ZF group; p = .4503). During a mean of 290.7 ± 169.6 days follow-up, no major adverse events were reported, and recurrence of the primary arrhythmia was 2.5% (2.1 vs. 3% in the ZF vs. non-ZF group; p = .7206). CONCLUSIONS: The Rhythmia mapping system permits transcatheter ablation of right-sided SVT with minimal fluoroscopy exposure. Even more, in most cases, the system enables a ZF approach, without affecting safety and efficacy.


Assuntos
Ablação por Cateter , Taquicardia Supraventricular , Adulto , Idoso , Ablação por Cateter/efeitos adversos , Feminino , Fluoroscopia , Humanos , Masculino , Pessoa de Meia-Idade , Sistema de Registros , Taquicardia Supraventricular/diagnóstico por imagem , Taquicardia Supraventricular/cirurgia , Resultado do Tratamento
6.
J Cardiovasc Electrophysiol ; 32(2): 468-476, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33296533

RESUMO

BACKGROUND: Current guidelines recommend defibrillation testing (DT) performance in patients with a subcutaneous implantable cardioverter defibrillator (S-ICD), theoretically to reduce the amount of ineffective shocks. DT, however, has been proven unnecessary in transvenous ICD and real-world data show a growing trend in avoidance of DT after S-ICD implantation. METHODS: All patients undergoing S-ICD implant at nine associated Italian centers joining in the ELISIR registry (ClinicalTrials.gov Identifier: NCT04373876) were enrolled and classified upon DT performance. Long-term follow-up events were recorded and compared to report the long-term efficacy and safety of S-ICD implantations without DT in a real-world setting. RESULTS: A total of 420 patients (54.0 ± 15.5 years, 80.0% male) were enrolled in the study. A DT was performed in 254 (60.5%) patients (DT+ group), while in 166 (39.5%) was avoided (DT- group). Over a median follow-up of 19 (11-31) months, a very low rate (0.7%) of ineffective shocks was observed, and no significant differences in the primary combined arrhythmic outcome were observed between the two groups (p = .656). At regression analysis, the only clinical predictor associated with the primary combined outcome was S-ICD placement for primary prevention (odds ratio: 0.42; p = .013); DT performance instead was not associated with a reduction in primary outcome (p = .375). CONCLUSION: Implanting an S-ICD without DT does not appear to impact the safety of defibrillation therapy and overall patients' survival.


Assuntos
Desfibriladores Implantáveis , Adulto , Idoso , Cardioversão Elétrica , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sistema de Registros , Resultado do Tratamento
7.
Pacing Clin Electrophysiol ; 44(6): 995-1003, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33908052

RESUMO

BACKGROUND: During the COVID-19 pandemic in-person visits for patients with cardiac implantable electronic devices should be replaced by remote monitoring (RM), in order to prevent viral transmission. A direct home-delivery service of the RM communicator has been implemented at 49 Italian arrhythmia centers. METHODS: According to individual patient preference or the organizational decision of the center, patients were assigned to the home-delivery group or the standard in-clinic delivery group. In the former case, patients received telephone training on the activation process and use of the communicator. In June 2020, the centers were asked to reply to an ad hoc questionnaire to describe and evaluate their experience in the previous 3 months. RESULTS: RM was activated in 1324 patients: 821 (62%) received the communicator at home and the communicator was activated remotely. Activation required one additional call in 49% of cases, and the median time needed to complete the activation process was 15 min [25th-75th percentile: 10-20]. 753 (92%) patients were able to complete the correct activation of the system. At the time when the questionnaire was completed, 743 (90%) communicators were regularly transmitting data. The service was generally deemed useful (96% of respondents) in facilitating the activation of RM during the COVID-19 pandemic and possibly beyond. CONCLUSIONS: Home delivery of the communicator proved to be a successful approach to system activation, and received positive feedback from clinicians. The increased use of a RM protocol will reduce risks for both providers and patients, while maintaining high-quality care.


Assuntos
Arritmias Cardíacas/terapia , COVID-19/epidemiologia , Desfibriladores Implantáveis , Serviços de Assistência Domiciliar , Distanciamento Físico , Pneumonia Viral/epidemiologia , Tecnologia de Sensoriamento Remoto/instrumentação , Feminino , Humanos , Incidência , Itália , Masculino , Marca-Passo Artificial , Pandemias , Pneumonia Viral/virologia , SARS-CoV-2
8.
J Thromb Thrombolysis ; 51(2): 419-429, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33044735

RESUMO

BACKGROUND: Direct oral anticoagulants (DOACs) are recommended as first-line anticoagulants in patients with atrial fibrillation (AF). However, in patients with cancer and AF the efficacy and safety of DOACs are not well established. OBJECTIVE: We performed a meta-analysis comparing available data regarding the efficacy and safety of DOACs vs vitamin K antagonists (VKAs) in cancer patients with non-valvular AF. METHODS: An online search of Pubmed and EMBASE libraries (from inception to May, 1 2020) was performed, in addition to manual screening. Nine studies were considered eligible for the meta-analysis involving 46,424 DOACs users and 182,797 VKA users. RESULTS: The use of DOACs was associated with reduced risks of systemic embolism or any stroke (RR 0.65; 95% CI 0.52-0.81; p 0.001), ischemic stroke (RR 0.84; 95% CI 0.74-0.95; p 0.007) and hemorrhagic stroke (RR 0.61; 95% CI 0.52-0.71; p 0.00001) as compared to VKA group. DOAC use was associated with significantly reduced risks of major bleeding (RR 0.68; 95% CI 0.50-0.92; p 0.01) and intracranial or gastrointestinal bleeding (RR 0.64; 95% CI 0.47-0.88; p 0.006). Compared to VKA, DOACs provided a non-statistically significant risk reduction of the outcomes major bleeding or non-major clinically relevant bleeding (RR 0.94; 95% CI 0.78-1.13; p 0.50) and any bleeding (RR 0.91; 95% CI 0.78-1.06; p 0.24). CONCLUSIONS: In comparison to VKA, DOACs were associated with a significant reduction of the rates of thromboembolic events and major bleeding complications in patients with AF and cancer. Further studies are needed to confirm our results.


Assuntos
Anticoagulantes/uso terapêutico , Fibrilação Atrial/complicações , Fibrilação Atrial/tratamento farmacológico , Inibidores do Fator Xa/uso terapêutico , Neoplasias/complicações , Vitamina K/antagonistas & inibidores , Anticoagulantes/efeitos adversos , Inibidores do Fator Xa/efeitos adversos , Hemorragia/induzido quimicamente , Humanos , Resultado do Tratamento
9.
J Cardiovasc Electrophysiol ; 31(5): 1166-1174, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32141116

RESUMO

INTRODUCTION: Early evidence suggests that multipoint left ventricular pacing (MPP) may improve response to cardiac resynchronization therapy (CRT). It is unknown whether this benefit is sustained and cost-effective. We used real-world data to evaluate long-term impact of MPP-ON clinical status, heart failure hospitalizations (HFH) and costs. METHODS: The Italian registry on multipoint left ventricular pacing is a prospective, multicenter registry of patients implanted with MPP-enabled CRT devices. For this analysis, clinical and echocardiographic data were collected through 24 months and compared between patients with (MPP-ON) or without (MPP-OFF) early MPP activation at implant. The total cost of each HFH was estimated with national Italian reimbursement rates. RESULTS: The study included 190 MPP-OFF and 128 MPP-ON patients with similar baseline characteristics. At 1 and 2 years, the MPP-ON group had lower rates of HFH vs MPP-OFF (1-year hazard ratio [HR]: 0.14, P = .0014; 2-year HR: 0.38, P = .009). The finding persisted in a subgroup of patients with consistent MPP activation through follow-up (1-year HR: 0.19; P = .0061; 2-year HR: 0.39, P = .022). Total HFH per-patient costs were lower in the MPP-ON vs the MPP-OFF group at 1 year (€101 ± 50 vs €698 ± 195, P < .001) and 2 years (€366 ± 149 vs €801 ± 203, P = .038). More MPP-ON patients had ≥5% improvement in ejection fraction (76.8% vs 65.4%, P = .025) and clinical composite score (66.7% vs 47.5%, P = .01). CONCLUSIONS: In this multicenter clinical study, early MPP activation was associated with a significant reduction in cumulative HFH and related costs after 1 and 2 years of follow-up.


Assuntos
Terapia de Ressincronização Cardíaca/economia , Custos de Cuidados de Saúde , Insuficiência Cardíaca/economia , Insuficiência Cardíaca/terapia , Idoso , Idoso de 80 Anos ou mais , Terapia de Ressincronização Cardíaca/efeitos adversos , Redução de Custos , Análise Custo-Benefício , Feminino , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Custos Hospitalares , Hospitalização/economia , Humanos , Itália , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Recuperação de Função Fisiológica , Sistema de Registros , Volume Sistólico , Fatores de Tempo , Resultado do Tratamento , Função Ventricular Esquerda
10.
J Cardiovasc Electrophysiol ; 31(11): 2814-2823, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32954600

RESUMO

INTRODUCTION: Remote monitoring (RM) has significantly transformed the standard of care for patients with cardiac electronic implantable devices. It provides easy access to valuable information, such as arrhythmic events, acute decompensation manifestations and device-related issues, without the need of in-person visits. METHODS: Starting March 1st, 332 patients were introduced to an RM program during the Italian lockdown to limit the risk of in-hospital exposure to severe acute respiratory syndrome-coronavirus-2. Patients were categorized into two groups based on the modality of RM delivery (home [n = 229] vs. office [n = 103] delivered). The study aimed at assessing the efficacy of the new follow-up protocol, assessed as mean RM activation time (AT), and the need for technical support. In addition, patients' acceptance and anxiety status were quantified via the Home Monitoring Acceptance and Satisfaction Questionnaire and the Generalized Anxiety Disorder 7-item scale. RESULTS: AT time was less than 48 h in 93% of patients and 7% of them required further technical support. Despite a higher number of trans-telephonic technical support in the home-delivered RM group, mean AT was similar between groups (1.33 ± 0.83 days in home-delivered vs 1.28 ± 0.81 days in office-delivered patients; p = .60). A total of 28 (2.5%) urgent/emergent in-person examinations were required. A high degree of patient satisfaction was reached in both groups whereas anxiety status was higher in the office-delivered group. CONCLUSIONS: The adoption of RM resulted in high patient satisfaction, regardless of the modality of modem delivery; nonetheless, in-office modem delivery was associated with a higher prevalence of anxiety symptoms.


Assuntos
COVID-19/prevenção & controle , Estimulação Cardíaca Artificial , Cardioversão Elétrica/instrumentação , Cardiopatias/terapia , Marca-Passo Artificial , Tecnologia de Sensoriamento Remoto , Telemedicina , Idoso , Idoso de 80 Anos ou mais , COVID-19/transmissão , Desfibriladores Implantáveis , Cardioversão Elétrica/efeitos adversos , Estudos de Viabilidade , Feminino , Cardiopatias/diagnóstico , Cardiopatias/fisiopatologia , Humanos , Itália , Masculino , Pessoa de Meia-Idade , Aceitação pelo Paciente de Cuidados de Saúde , Satisfação do Paciente , Valor Preditivo dos Testes , Estudos Prospectivos , Desenho de Prótese , Falha de Prótese
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA