Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
J Biomed Sci ; 27(1): 96, 2020 Oct 02.
Artigo em Inglês | MEDLINE | ID: mdl-33008372

RESUMO

BACKGROUND: A lung transplant is the last resort treatment for many patients with advanced lung disease. The majority of donated lungs come from donors following brain death (BD). The endothelin axis is upregulated in the blood and lung of the donor after BD resulting in systemic inflammation, lung damage and poor lung graft outcomes in the recipient. Tezosentan (endothelin receptor blocker) improves the pulmonary haemodynamic profile; however, it induces adverse effects on other organs at high doses. Application of ex vivo lung perfusion (EVLP) allows the development of organ-specific hormone resuscitation, to maximise and optimise the donor pool. Therefore, we investigate whether the combination of EVLP and tezosentan administration could improve the quality of donor lungs in a clinically relevant 6-h ovine model of brain stem death (BSD). METHODS: After 6 h of BSD, lungs obtained from 12 sheep were divided into two groups, control and tezosentan-treated group, and cannulated for EVLP. The lungs were monitored for 6 h and lung perfusate and tissue samples were processed and analysed. Blood gas variables were measured in perfusate samples as well as total proteins and pro-inflammatory biomarkers, IL-6 and IL-8. Lung tissues were collected at the end of EVLP experiments for histology analysis and wet-dry weight ratio (a measure of oedema). RESULTS: Our results showed a significant improvement in gas exchange [elevated partial pressure of oxygen (P = 0.02) and reduced partial pressure of carbon dioxide (P = 0.03)] in tezosentan-treated lungs compared to controls. However, the lungs hematoxylin-eosin staining histology results showed minimum lung injuries and there was no difference between both control and tezosentan-treated lungs. Similarly, IL-6 and IL-8 levels in lung perfusate showed no difference between control and tezosentan-treated lungs throughout the EVLP. Histological and tissue analysis showed a non-significant reduction in wet/dry weight ratio in tezosentan-treated lung tissues (P = 0.09) when compared to control. CONCLUSIONS: These data indicate that administration of tezosentan could improve pulmonary gas exchange during EVLP.


Assuntos
Antagonistas dos Receptores de Endotelina/farmacologia , Pulmão/efeitos dos fármacos , Piridinas/farmacologia , Testes de Função Respiratória , Tetrazóis/farmacologia , Vasodilatadores/farmacologia , Animais , Modelos Animais de Doenças , Pulmão/fisiologia , Perfusão , Carneiro Doméstico , Doadores de Tecidos
2.
Biomed Microdevices ; 19(4): 98, 2017 Nov 07.
Artigo em Inglês | MEDLINE | ID: mdl-29116412

RESUMO

Thin and flexible polymeric membranes play a critical role in tissue engineering applications for example organs-on-a-chip. These flexible membranes can enable mechanical stretch of the engineered tissue to mimic organ-specific biophysical features, such as breathing. In this work, we report the fabrication of thin (<20 µm), stretchable, and biocompatible polyurethane (PU) membranes. The membranes were fabricated using spin coating technique on silicon substrates and were mounted on a frame for ease of device integration and handling. The membranes were characterized for their optical and elastic properties and compatibility with cell/tissue culture. It was possible to apply up to 10 kilopascal (kPa) pressure to perform cyclic stretch on 4 mm-diameter membranes for a period of 2 weeks at 0.2 hertz (Hz) frequency without mechanical failure. Adenocarcinomic human alveolar basal epithelial (A549) cells were cultured on the apical side of the PU membrane. The morphology and viability of the cells were comparable to those of cells cultured on standard tissue culture plates. Our experiments suggest that the stretchable PU membrane will be broadly useful for various tissue engineering applications in vitro.


Assuntos
Membranas/química , Poliuretanos/química , Engenharia Tecidual , Células A549 , Materiais Biocompatíveis/química , Materiais Biomiméticos , Sobrevivência Celular , Humanos , Dispositivos Lab-On-A-Chip , Modelos Teóricos , Polímeros/química , Alicerces Teciduais
3.
Biomed J ; 45(5): 776-787, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34666219

RESUMO

INTRODUCTION: Organs procured following brain stem death (BSD) are the main source of organ grafts for transplantation. However, BSD is associated with inflammatory responses that may damage the organ and affect both the quantity and quality of organs available for transplant. Therefore, we aimed to investigate plasma and bronchoalveolar lavage (BAL) pro-inflammatory cytokine profiles and cardiovascular physiology in a clinically relevant 6-h ovine model of BSD. METHODS: Twelve healthy female sheep (37-42 Kg) were anaesthetized and mechanically ventilated prior to undergoing BSD induction and then monitored for 6 h. Plasma and BAL endothelin-1 and cytokines (IL-1ß, 6, 8 and tumour necrosis factor alpha (TNF-α)) were assessed by ELISA. Differential white blood cell counts were performed. Cardiac function during BSD was also examined using echocardiography, and cardiac biomarkers (A-type natriuretic peptide and troponin I were measured in plasma. RESULTS: Plasma concentrations big ET-1, IL-6, IL-8, TNF-α and BAL IL-8 were significantly (p < 0.01) increased over baseline at 6 h post-BSD. Increased numbers of neutrophils were observed in the whole blood (3.1 × 109 cells/L [95% confidence interval (CI) 2.06-4.14] vs. 6 × 109 cells/L [95%CI 3.92-7.97]; p < 0.01) and BAL (4.5 × 109 cells/L [95%CI 0.41-9.41] vs. 26 [95%CI 12.29-39.80]; p = 0.03) after 6 h of BSD induction vs baseline. A significant increase in ANP production (20.28 pM [95%CI 16.18-24.37] vs. 78.68 pM [95%CI 53.16-104.21]; p < 0.0001) and cTnI release (0.039 ng/mL vs. 4.26 [95%CI 2.69-5.83] ng/mL; p < 0.0001), associated with a significant reduction in heart contractile function, were observed between baseline and 6 h. CONCLUSIONS: BSD induced systemic pro-inflammatory responses, characterized by increased neutrophil infiltration and cytokine production in the circulation and BAL fluid, and associated with reduced heart contractile function in ovine model of BSD.


Assuntos
Cardiopatias , Fator de Necrose Tumoral alfa , Ovinos , Animais , Feminino , Fator de Necrose Tumoral alfa/metabolismo , Interleucina-8 , Citocinas/metabolismo , Tronco Encefálico
4.
Intern Med J ; 40(7): 476-85, 2010 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-20059600

RESUMO

Echocardiography is the mainstay of cardiovascular diagnostics, and is the most performed test for the evaluation of cardiac function. Critical and costly management decisions are based on quantification of left ventricular volumes and ejection fraction. Recent advances in echocardiography, such as microsphere contrast echocardiography for left ventricular opacification and perfusion imaging, three-dimensional transthoracic and trans-oesophageal imaging, strain and tissue Doppler imaging, all contribute to improving accuracy and reproducibility of these important measurements. Such techniques are now routinely available on standard echocardiography equipment in Australian centres for daily use. Hand-carried ultrasound devices have been developed, which are portable, are affordable and offer increased availability of echocardiography to the wider community. Clinicians should be actively encouraged to adopt these technologies to improve the diagnostic quality and reproducability of echocardiography for our patients. This article provides an overview of important recent advances in echocardiographic imaging with an emphasis on their role in clinical practice today.


Assuntos
Doenças Cardiovasculares/diagnóstico por imagem , Ecocardiografia/instrumentação , Ecocardiografia/tendências , Médicos/tendências , Ecocardiografia/métodos , Humanos , Imageamento Tridimensional/instrumentação , Imageamento Tridimensional/métodos , Imageamento Tridimensional/tendências
5.
Eur J Cardiothorac Surg ; 22(5): 845-6, 2002 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-12414061

RESUMO

Systemic arterial embolism is a potentially lethal complication of bronchopulmonary venous fistula in trauma patients with blunt chest trauma or isolated penetrating lung injury on positive pressure ventilation. A high index of suspicion, early diagnosis and management in specialized centres are keys to a successful outcome.


Assuntos
Ponte Cardiopulmonar , Embolia Aérea/complicações , Choque Cardiogênico/etiologia , Choque Traumático/etiologia , Ferimentos por Arma de Fogo/complicações , Adulto , Embolia Aérea/cirurgia , Humanos , Masculino
6.
Sarcoidosis Vasc Diffuse Lung Dis ; 31(1): 71-5, 2014 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-24751457

RESUMO

Non tropical, non hypereosinophilic endo myocardial fibrosis has been reported in literature and is a rare entity.  Cardiac Sarcoidosis manifesting as non-tropical, non hypereosinophilic endomyocardial fibrosis is unknown, though it classically affects the left ventricle and is not associated with specific risk factors. We describe an atypical presentation of sarcoidosis as non-tropical non hypereosinophilic endomyocardial fibrosis in a middle aged female who presented to us with refractory heart failure.


Assuntos
Cardiomiopatias/diagnóstico , Sarcoidose/diagnóstico , Cardiomiopatias/complicações , Fibrose Endomiocárdica/etiologia , Feminino , Humanos , Pessoa de Meia-Idade , Sarcoidose/complicações
7.
Appl Opt ; 26(18): 3803-10, 1987 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-20490144

RESUMO

Optical properties of spray-deposited tin oxide (TO) films are studied here. Optical grade TO films were deposited using monobutyl tin chloride and dibutyl tin diacetate solutions. The refractive index and extinction coefficient, n(lambda) and k(lambda), respectively, and film thickness of TO films are evaluated from spectrophotometric transmittance characteristics examined in the visible and UV regions. Since the interference effects are suppressed by the optical absorption in the near-IR region, both reflectance and transmittance spectra are used to evaluate n(lambda) and k(lambda) values. Spray-deposited TO films are found to be an indirect band gap material exhibiting an absorption minimum at ~1.0 microm (k less, similar 10(-3)), an energy gap at ~3.7 eV. A transition from a bounded electron model to a free electron model occurs at lambda approximately 1.4 microm.

8.
Med J Aust ; 159(3): 216, 1993 Aug 02.
Artigo em Inglês | MEDLINE | ID: mdl-8336637
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA