Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 52
Filtrar
1.
Ann Plast Surg ; 88(6): 641-646, 2022 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-35180745

RESUMO

INTRODUCTION: Although neurotization has the potential to improve sensory outcomes after autologous breast reconstruction, this technique remains controversial. There is debate regarding the clinical outcomes and the recipient nerve of choice. This histoanatomical study aims to quantitatively compare the sensory components of the recipient nerves involved in neurotization of the deep inferior epigastric perforator flap. METHODS: Subjects undergoing bilateral autologous breast reconstruction were enrolled. Transected nerve specimens underwent immunohistochemical staining with antibodies against neurofilament 1 and choline acetyltransferase for total and motor neurons within the axons, respectively. Photomicrographs were captured, and axons were analyzed using ImageJ. Sensory axons were calculated as equal to the difference between the total and cholinergic axonal counts. RESULTS: Thirty-eight nerves from 19 subjects were included. The overall mean sensory axon count was 1246.3 (±1171.9) in the lateral cutaneous branch (LCB) of the fourth intercostal nerve and 1123.8 (±1213.0) in the anterior cutaneous branch (ACB) of the third intercostal nerve.The fourth LCB presented with an additional 10.9% sensory axonal count (P > 0.05). On average, sensory fibers constituted 36.7% and 31.7% of all fibers in the third ACBs and fourth LCBs, respectively. CONCLUSIONS: This study provides anatomic and histological evidence that the fourth LCB and third ACB contain comparable mean numbers of sensory axons. Both constitute adequate recipient nerves for coaptation in deep inferior epigastric perforator reinnervation to achieve optimal sensory return after breast reconstruction. The fourth LCB should be preferable when the third ACB remains intact to preserve any native breast flap sensation.


Assuntos
Neoplasias da Mama , Mamoplastia , Transferência de Nervo , Retalho Perfurante , Neoplasias da Mama/cirurgia , Artérias Epigástricas/cirurgia , Feminino , Humanos , Nervos Intercostais/cirurgia , Mamoplastia/métodos , Retalho Perfurante/cirurgia , Sensação
2.
Ann Plast Surg ; 83(1): 40-42, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-31192878

RESUMO

Although the upper extremity is the most commonly injured part of the body, many studies have indicated that there is a lack of emergency hand coverage in the United States. In 2010, our laboratory evaluated on-call hand coverage in Tennessee (TN) and found that only 7% of hospitals had a hand surgeon on call for emergency cases at all times. In 2014, the Affordable Care Act (ACA) was implemented with the goal of increasing overall access to care and decreasing health care costs. Hand surgeons were surveyed on their attitudes toward the ACA, and the majority of surgeons surveyed disagreed or strongly disagree that the ACA would improve access to emergent hand surgery. This study aimed to determine if there has been an increase in emergency hand coverage in TN since the implementation of the ACA. A survey was administered to all hospitals in TN with both an emergency department and operating room to determine the percentage of TN hospitals offering elective hand surgery and on-call emergency hand coverage. With 94% of TN hospitals responding to the emergency department survey, we determined that there has been a 138% significant increase in the percentage of hospitals reporting 24/7 emergency hand coverage by a hand specialist since our last study in 2010. There has also been a significant increase in elective hand coverage in TN, although much smaller at 13% since 2010. This study suggests that there has been an overall increase in access to hand care in TN since the implementation of the ACA, most profoundly seen in the increase in hand specialists available for emergent cases.


Assuntos
Procedimentos Cirúrgicos Eletivos/economia , Emergências/economia , Traumatismos da Mão/cirurgia , Patient Protection and Affordable Care Act/economia , Melhoria de Qualidade , Adulto , Procedimentos Cirúrgicos Eletivos/estatística & dados numéricos , Serviço Hospitalar de Emergência/economia , Serviço Hospitalar de Emergência/estatística & dados numéricos , Feminino , Traumatismos da Mão/economia , Custos de Cuidados de Saúde , Custos Hospitalares , Humanos , Cobertura do Seguro/economia , Cobertura do Seguro/estatística & dados numéricos , Masculino , Patient Protection and Affordable Care Act/estatística & dados numéricos , Inquéritos e Questionários , Tennessee
3.
Ann Plast Surg ; 81(2): 198-202, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29781850

RESUMO

Peripheral nerve gap injuries continue to present a clinical challenge to today's surgeons. One method of surgical repair, implantation of acellular allografts, has been developed with the aim of bridging the gap with a cadaveric graft after removal of its cellular components, thereby accelerating axonal regeneration and eliminating the need for immunosuppression in recipient patients. Although decellularizing allografts reduces rates of graft rejection, the same chemical processing modifies the neural microenvironment, removing neutrotrophic factors and modifying the complex extracellular matrix. In this study, we explore 3 common methods for producing acellular allografts. Extracellular matrix content remaining after processing was investigated and was found to be highly dependent on the decellularization method. In addition, scanning electron micrographs were obtained to evaluate the structural effects of the decellularization methods. Though the content and structure of these processed allografts will contribute to their effectiveness as nerve gap repair candidates, we demonstrate that it also affects their capacity to be supplemented/preloaded with the prototypical neurotrophin, nerve growth factor (NGF), essential to neuronal regeneration. Although all allografts had some capacity for retaining NGF in the first 24 hours, only Sondell-processed grafts retained NGF over the entire experimental period of 21 days. Future studies will include validating these processed and supplemented allografts as viable alternatives to traditional autograft nerve gap repair.


Assuntos
Aloenxertos/metabolismo , Matriz Extracelular/metabolismo , Fator de Crescimento Neural/metabolismo , Procedimentos Neurocirúrgicos/métodos , Traumatismos dos Nervos Periféricos/cirurgia , Nervo Isquiático/transplante , Animais , Biomarcadores/metabolismo , Microscopia Eletrônica de Varredura , Regeneração Nervosa/fisiologia , Ratos , Ratos Sprague-Dawley , Nervo Isquiático/metabolismo , Transplante Homólogo/métodos
4.
Ann Plast Surg ; 80(4): 384-390, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29443831

RESUMO

PURPOSE: Given no definite consensus on the accepted autograft orientation during peripheral nerve injury repair, we compare outcomes between reverse and normally oriented autografts using an advanced magnetic resonance imaging technique, diffusion tensor imaging. METHODS: Thirty-six female Sprague-Dawley rats were divided into 3 groups: sham-left sciatic nerve isolation without injury, reverse autograft-10-mm cut left sciatic nerve segment reoriented 180° and used to coapt the proximal and distal stumps, or normally oriented autograft-10-mm cut nerve segment kept in its normal orientation for coaptation. Animals underwent sciatic functional index and foot fault behavior studies at 72 hours, and then weekly. At 6 weeks, axons proximal, within, and distal to the autograft were evaluated using diffusion tensor imaging and choline acetyltransferase motor staining for immunohistochemistry. Toluidine blue staining of 1-µm sections was used to assess axon count, density, and diameter. Bilateral gastrocnemius/soleus muscle weights were compared to obtain a net wet weight. Comparison of the groups was performed using Mann-Whiney U or Kruskal-Wallis H tests to determine significance. RESULTS: Diffusion tensor imaging findings including fractional anisotropy, radial diffusivity, and axial diffusivity were similar between reverse and normally oriented autografts. Diffusion tensor imaging tractography demonstrated proximodistal nerve regeneration in both autograft groups. Motor axon counts proximal, within, and distal to the autografts were similar. Likewise, axon count, density, and diameter were similar between the autograft groups. Muscle net weight at 6 weeks and behavioral outcomes (sciatic functional index and foot fault) at any tested time point were also similar between reverse and normally oriented autografts. CONCLUSIONS: Diffusion tensor imaging may be a useful assessment tool for peripheral nerve regeneration. Reversing nerve autograft polarity did not demonstrate to have an influence on functional or regenerative outcomes.


Assuntos
Imagem de Tensor de Difusão , Microcirurgia/métodos , Regeneração Nervosa/fisiologia , Procedimentos Neurocirúrgicos/métodos , Nervo Isquiático/cirurgia , Animais , Anisotropia , Autoenxertos , Modelos Animais de Doenças , Feminino , Imuno-Histoquímica , Ratos , Ratos Sprague-Dawley , Recuperação de Função Fisiológica
5.
Int J Neurosci ; 128(6): 563-569, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29098916

RESUMO

BACKGROUND: Conduit-based nerve repairs are commonly used for small nerve gaps, whereas primary repair may be performed if there is no tension on nerve endings. We hypothesize that a conduit-based nerve coaptation device will improve nerve repair outcomes by avoiding sutures at the nerve repair site and utilizing the advantages of a conduit-based repair. METHODS: The left sciatic nerves of female Sprague-Dawley rats were transected and repaired using a novel conduit-based device. The conduit-based device group was compared to a control group of rats that underwent a standard end-to-end microsurgical repair of the sciatic nerve. Animals underwent behavioral assessments at weekly intervals post-operatively using the sciatic functional index (SFI) test. Animals were sacrificed at four weeks to obtain motor axon counts from immunohistochemistry. A sub-group of animals were sacrificed immediately post repair to obtain MRI images. RESULTS: SFI scores were superior in rats which received conduit-based repairs compared to the control group. Motor axon counts distal to the injury in the device group at four weeks were statistically superior to the control group. MRI tractography was used to demonstrate repair of two nerves using the novel conduit device. CONCLUSIONS: A conduit-based nerve coaptation device avoids sutures at the nerve repair site and leads to improved outcomes in a rat model. Conduit-based nerve repair devices have the potential to standardize nerve repairs while improving outcomes.


Assuntos
Matriz Extracelular , Regeneração Nervosa/fisiologia , Traumatismos dos Nervos Periféricos/terapia , Nervo Isquiático , Animais , Imagem de Tensor de Difusão , Modelos Animais de Doenças , Feminino , Microcirurgia , Traumatismos dos Nervos Periféricos/diagnóstico por imagem , Traumatismos dos Nervos Periféricos/cirurgia , Ratos , Ratos Sprague-Dawley , Nervo Isquiático/lesões , Nervo Isquiático/fisiologia , Nervo Isquiático/cirurgia
6.
J Hand Surg Am ; 43(1): 82.e1-82.e7, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-28823535

RESUMO

PURPOSE: Polyethylene glycol (PEG) has been hypothesized to restore axonal continuity using an in vivo rat sciatic nerve injury model when nerve repair occurs within minutes after nerve injury. We hypothesized that PEG could restore axonal continuity when nerve repair was delayed. METHODS: The left sciatic nerves of female Sprague-Dawley rats were transected and repaired in an end-to-end fashion using standard microsurgical techniques at 3 time points (1, 8, and 24 hours) after injury. Polyethylene glycol was delivered to the neurorrhaphy in the experimental group. Post-repair compound action potentials were immediately recorded after repair. Animals underwent behavioral assessments at 3 days and 1 week after surgery using the sciatic functional index test. The animals were sacrificed at 1 week to obtain axon counts. RESULTS: The PEG-treated nerves had improved compound action potential conduction and animals treated with PEG had improved sciatic function index. Compound action potential conduction was restored in PEG-fused rats when nerves were repaired at 1, 8, and 24 hours. In the control groups, no compound action potential conduction was restored when nerves were repaired. Sciatic functional index was superior in PEG-fused rats at 3 and 7 days after surgery compared with control groups at all 3 time points of nerve repair. Distal motor and sensory axon counts were higher in the PEG-treated rats. CONCLUSIONS: Polyethylene glycol fusion is a new adjunct for nerve repair that allows rapid restoration of axonal continuity. It effective when delayed nerve repair is performed. CLINICAL RELEVANCE: Nerve repair with application of PEG is a potential therapy that may have efficacy in a clinical setting. It is an experimental therapy that needs more investigation as well as clinical trials.


Assuntos
Procedimentos Neurocirúrgicos , Polietilenoglicóis/administração & dosagem , Nervo Isquiático/lesões , Nervo Isquiático/cirurgia , Neuropatia Ciática/tratamento farmacológico , Neuropatia Ciática/cirurgia , Potenciais de Ação/efeitos dos fármacos , Animais , Axônios/patologia , Microcirurgia , Modelos Animais , Condução Nervosa/efeitos dos fármacos , Ratos Sprague-Dawley , Tempo para o Tratamento
7.
J Mater Sci Mater Med ; 28(1): 20, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28012154

RESUMO

Peripheral nerve repair using nerve grafts has been investigated for several decades using traditional techniques such as histology, immunohistochemistry, and electron microscopy. Recent advances in mass spectrometry techniques have made it possible to study the proteomes of complex tissues, including extracellular matrix rich tissues similar to peripheral nerves. The present study comparatively assessed three previously described processing methods for generating acellular nerve grafts by mass spectrometry. Acellular nerve grafts were additionally examined by F-actin staining and nuclear staining for debris clearance. Application of newer techniques allowed us to detect and highlight differences among the 3 treatments. Isolated proteins were separated by mass on polyacrylamide gels serving 2 purposes. This further illustrated that these treatments differ from one another and it allowed for selective protein extractions within specific bands/molecular weights. This approach resulted in small pools of proteins that could then be analyzed by mass spectrometry for content. In total, 543 proteins were identified, many of which corroborate previous findings for these processing methods. The remaining proteins are novel discoveries that expand the field. With this pilot study, we have proven that mass spectrometry techniques complement and add value to peripheral nerve repair studies.


Assuntos
Espectrometria de Massas , Regeneração Nervosa , Nervo Isquiático/transplante , Actinas/metabolismo , Aloenxertos , Animais , Núcleo Celular/metabolismo , Eletroforese em Gel de Poliacrilamida , Matriz Extracelular/metabolismo , Feminino , Imuno-Histoquímica , Microscopia Eletrônica , Peso Molecular , Neurônios , Sistema Nervoso Periférico/fisiologia , Projetos Piloto , Ratos , Ratos Sprague-Dawley , Reprodutibilidade dos Testes
8.
Ann Plast Surg ; 78(6S Suppl 5): S328-S334, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28328634

RESUMO

PURPOSE: This study aims to compare engineered nerve conduits constructed from porcine-derived urinary bladder matrix (UBM) with the criterion-standard nerve autografts, for segmental loss peripheral nerve repairs. METHODS: Forty-eight Sprague-Dawley rats were divided into 2 groups. All underwent a 10-mm sciatic nerve gap injury. This was repaired using either (1) reverse autograft-the 10-mm cut segment was oriented 180 degrees and used to coapt the proximal and distal stumps or (2) UBM conduit-the 10-mm nerve gap was bridged with UBM conduit. Behavior assessments such as sciatic function index and foot fault asymmetry scores were performed weekly. At 3- or 6-week time endpoints, the repaired nerves and bilateral gastrocnemius/soleus muscles were harvested from each animal. Nerves were evaluated using immunohistochemistry for motor and sensory axon staining and with diffusion tensor imaging. The net wet muscle weights were calculated to assess the degree of muscle atrophy. RESULTS: The UBM group demonstrated significantly improved foot fault asymmetry scores at 2 and 4 weeks, whereas there was no difference in sciatic function index. The net muscle weights were similar between both groups. Motor axon counts proximal/inside/distal to the conduit/graft were similar between UBM conduits and reverse autografts, whereas sensory axon counts within and distal to the conduit were significantly higher than those of the autograft at 6 weeks. Sensory axonal regeneration seemed to be adherent to the inner surface of the UBM conduit, whereas it had a scattered appearance in autografts. Diffusion tensor imaging parameters between groups were similar. CONCLUSIONS: Urinary bladder matrix conduits prove to be at least similar to nerve autografts for the repair of peripheral nerve injuries with a short gap. The matrix perhaps serves as a scaffold to augment sensory nerve growth. CLINICAL RELEVANCE: In a clinical setting, UBM may eliminate the donor site morbidity and increased operative time associated with nerve autografting.


Assuntos
Regeneração Nervosa/fisiologia , Nervo Isquiático/lesões , Engenharia Tecidual , Alicerces Teciduais , Animais , Autoenxertos , Imagem de Tensor de Difusão , Modelos Animais de Doenças , Feminino , Traumatismos dos Nervos Periféricos/cirurgia , Distribuição Aleatória , Ratos , Ratos Sprague-Dawley , Fatores de Risco , Nervo Isquiático/cirurgia , Sensibilidade e Especificidade , Suínos , Bexiga Urinária/diagnóstico por imagem , Bexiga Urinária/cirurgia , Derivação Urinária
9.
Ann Plast Surg ; 79(6): 590-599, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29053522

RESUMO

BACKGROUND: The management of peripheral nerve injuries remains a large challenge for plastic surgeons. With the inability to fuse axonal endings, results after microsurgical nerve repair have been inconsistent. Our current nerve repair strategies rely upon the slow and lengthy process of axonal regeneration (~1 mm/d). Polyethylene glycol (PEG) has been investigated as a potential axonal fusion agent; however, the percentage of axonal fusion has been inconsistent. The purpose of this study was to identify a PEG delivery device to standardize outcomes after attempted axonal fusion with PEG. MATERIALS AND METHODS: We used a rat sciatic nerve injury model in which we completely transected and repaired the left sciatic nerve to evaluate the efficacy of PEG fusion over a span of 12 weeks. In addition, we evaluated the effectiveness of a delivery device's ability to optimize results after PEG fusion. RESULTS: We found that PEG rapidly (within minutes) restores axonal continuity as assessed by electrophysiology, fluorescent retrograde tracer, and diffusion tensor imaging. Immunohistochemical analysis shows that motor axon counts are significantly increased at 1 week, 4 weeks, and 12 weeks postoperatively in PEG-treated animals. Furthermore, PEG restored behavioral functions up to 50% compared with animals that received the criterion standard epineurial repair (control animals). CONCLUSIONS: The ability of PEG to rapidly restore nerve function after neurotmesis could have vast implications on the clinical management of traumatic injuries to peripheral nerves.


Assuntos
Sistemas de Liberação de Medicamentos/instrumentação , Regeneração Nervosa/efeitos dos fármacos , Traumatismos dos Nervos Periféricos/cirurgia , Polietilenoglicóis/farmacologia , Nervo Isquiático/lesões , Traumatismos do Sistema Nervoso/cirurgia , Animais , Axônios/efeitos dos fármacos , Modelos Animais de Doenças , Eletromiografia/métodos , Feminino , Imuno-Histoquímica , Masculino , Regeneração Nervosa/fisiologia , Procedimentos Neurocirúrgicos/métodos , Traumatismos dos Nervos Periféricos/tratamento farmacológico , Distribuição Aleatória , Ratos , Ratos Sprague-Dawley , Recuperação de Função Fisiológica , Nervo Isquiático/cirurgia
10.
Exp Dermatol ; 25(2): 143-6, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26440596

RESUMO

Herein we present a simple, reproducible and versatile approach for in situ protein digestion and identification on formalin-fixed and paraffin-embedded (FFPE) tissues. This adaptation is based on the use of an enzyme delivery platform (hydrogel discs) that can be positioned on the surface of a tissue section. By simultaneous deposition of multiple hydrogels over select regions of interest within the same tissue section, multiple peptide extracts can be obtained from discrete histological areas. After enzymatic digestion, the hydrogel extracts are submitted for LC-MS/MS analysis followed by database inquiry for protein identification. Further, imaging mass spectrometry (IMS) is used to reveal the spatial distribution of the identified peptides within a serial tissue section. Optimization was achieved using cutaneous tissue from surgically excised pressure ulcers that were subdivided into two prime regions of interest: the wound bed and the adjacent dermal area. The robust display of tryptic peptides within these spectral analyses of histologically defined tissue regions suggests that LC-MS/MS in combination with IMS can serve as useful exploratory tools.


Assuntos
Biópsia/métodos , Úlcera por Pressão/metabolismo , Proteínas/isolamento & purificação , Proteômica/métodos , Cromatografia Líquida , Amarelo de Eosina-(YS) , Formaldeído , Hematoxilina , Humanos , Hidrogéis , Inclusão em Parafina , Úlcera por Pressão/patologia , Manejo de Espécimes , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz , Coloração e Rotulagem , Espectrometria de Massas em Tandem , Fixação de Tecidos , Tripsina/farmacologia
11.
Wound Repair Regen ; 24(5): 775-785, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27256813

RESUMO

The spatiotemporal analysis of the proteomic profile during human wound healing is a critical investigative step that can establish the complex interplay of molecular events that comprise the local response to burn injury. Partial-thickness wound samples with adjacent "normal" skin were collected from twenty-one patients with burn wounds and examined across a time spectrum ranging from the acute injury period at 3, 6, 11 days to the later hypertrophic scar period at 7 and 15 months. The techniques used for histology-directed tissue analyses highlighted inflammatory protein markers at the early time points after injury with diminished expression as burn wounds progressed into the proliferative phase. The datasets show the usefulness of MALDI MS and imaging mass spectrometry as discovery approaches to identify and map the cutaneous molecular sequence that is activated in response to the unique systemic inflammatory response following burn trauma. This information has the potential to define the unique factors that predispose human burn victims to disfiguring hypertrophic scar formation.

12.
J Proteome Res ; 14(2): 986-96, 2015 Feb 06.
Artigo em Inglês | MEDLINE | ID: mdl-25488653

RESUMO

Imaging mass spectrometry (IMS) was employed for the analysis of frozen skin biopsies to investigate the differences between stage IV pressure ulcers that remain stalled, stagnant, and unhealed versus those exhibiting clinical and histological signs of improvement. Our data reveal a rich diversity of proteins that are dynamically modulated, and we selectively highlight a family of calcium binding proteins (S-100 molecules) including calcyclin (S100-A6), calgranulins A (S100-A8) and B (S100-A9), and calgizzarin (S100-A11). IMS allowed us to target three discrete regions of interest: the wound bed, adjacent dermis, and hypertrophic epidermis. Plots derived using unsupervised principal component analysis of the global protein signatures within these three spatial niches indicate that these data from wound signatures have potential as a prognostic tool since they appear to delineate wounds that are favorably responding to therapeutic interventions versus those that remain stagnant or intractable in their healing status. Our discovery-based approach with IMS augments current knowledge of the molecular signatures within pressure ulcers while providing a rationale for a focused examination of the role of calcium modulators within the context of impaired wound healing.


Assuntos
Espectrometria de Massas/métodos , Imagem Molecular/métodos , Úlcera por Pressão/metabolismo , Proteoma/análise , Cicatrização/fisiologia , Adolescente , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Proteômica/métodos , Proteínas S100 , Adulto Jovem
13.
J Surg Res ; 193(2): 969-77, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25438961

RESUMO

BACKGROUND: Acellular nerve allografts are now standard tools in peripheral nerve repair because of decreased donor site morbidity and operative time savings. Preparation of nerve allografts involves several steps of decellularization and modification of extracellular matrix to remove chondroitin sulfate proteoglycans (CSPGs), which have been shown to inhibit neurite outgrowth through a poorly understood mechanism involving RhoA and extracellular matrix-integrin interactions. Chondroitinase ABC (ChABC) is an enzyme that degrades CSPG molecules and has been shown to promote neurite outgrowth after injury of the central and peripheral nervous systems. Variable results after ChABC treatment make it difficult to predict the effects of this drug in human nerve allografts, especially in the presence of native extracellular signaling molecules. Several studies have shown cross-talk between neurotrophic factor and CSPG signaling pathways, but their interaction remains poorly understood. In this study, we examined the adjuvant effects of nerve growth factor (NGF) and glial cell line-derived neurotrophic factor (GDNF) on neurite outgrowth postinjury in CSPG-reduced substrates and acellular nerve allografts. MATERIALS AND METHODS: E12 chicken DRG explants were cultured in medium containing ChABC, ChABC + NGF, ChABC + GDNF, or control media. Explants were imaged at 3 d and neurite outgrowths measured. The rat sciatic nerve injury model involved a 1-cm sciatic nerve gap that was microsurgically repaired with ChABC-pretreated acellular nerve allografts. Before implantation, nerve allografts were incubated in NGF, GDNF, or sterile water. Nerve histology was evaluated at 5 d and 8 wk postinjury. RESULTS: The addition of GDNF in vitro produced significant increase in sensory neurite length at 3 d compared with ChABC alone (P < 0.01), whereas NGF was not significantly different from control. In vivo adjuvant NGF produced increases in total myelinated axon count (P < 0.005) and motor axon count (P < 0.01), whereas significantly reducing IB4+ nociceptor axon count (P < 0.01). There were no significant differences produced by in vivo adjuvant GDNF. CONCLUSIONS: This study provides initial evidence that CSPG-reduced nerve grafts may disinhibit the prosurvival effects of NGF in vivo, promoting motor axon outgrowth and reducing regeneration of specific nociceptive neurons. Our results support further investigation of adjuvant NGF therapy in CSPG-reduced acellular nerve grafts.


Assuntos
Fator Neurotrófico Derivado de Linhagem de Célula Glial/uso terapêutico , Fator de Crescimento Neural/uso terapêutico , Neuritos/efeitos dos fármacos , Traumatismos dos Nervos Periféricos/cirurgia , Nervo Isquiático/transplante , Aloenxertos/efeitos dos fármacos , Animais , Quimioterapia Adjuvante , Embrião de Galinha , Proteoglicanas de Sulfatos de Condroitina , Avaliação Pré-Clínica de Medicamentos , Feminino , Gânglios Espinais/efeitos dos fármacos , Fator Neurotrófico Derivado de Linhagem de Célula Glial/farmacologia , Fator de Crescimento Neural/farmacologia , Traumatismos dos Nervos Periféricos/tratamento farmacológico , Ratos Sprague-Dawley
14.
Neurosurg Focus ; 39(3): E9, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26323827

RESUMO

Diagnosis and management of peripheral nerve injury is complicated by the inability to assess microstructural features of injured nerve fibers via clinical examination and electrophysiology. Diffusion tensor imaging (DTI) has been shown to accurately detect nerve injury and regeneration in crush models of peripheral nerve injury, but no prior studies have been conducted on nerve transection, a surgical emergency that can lead to permanent weakness or paralysis. Acute sciatic nerve injuries were performed microsurgically to produce multiple grades of nerve transection in rats that were harvested 1 hour after surgery. High-resolution diffusion tensor images from ex vivo sciatic nerves were obtained using diffusion-weighted spin-echo acquisitions at 4.7 T. Fractional anisotropy was significantly reduced at the injury sites of transected rats compared with sham rats. Additionally, minor eigenvalues and radial diffusivity were profoundly elevated at all injury sites and were negatively correlated to the degree of injury. Diffusion tensor tractography showed discontinuities at all injury sites and significantly reduced continuous tract counts. These findings demonstrate that high-resolution DTI is a promising tool for acute diagnosis and grading of traumatic peripheral nerve injuries.


Assuntos
Imagem de Tensor de Difusão , Traumatismos dos Nervos Periféricos/diagnóstico , Doença Aguda , Animais , Anisotropia , Modelos Animais de Doenças , Feminino , Humanos , Extremidade Inferior/patologia , Masculino , Curva ROC , Ratos Sprague-Dawley , Neuropatia Ciática/diagnóstico , Sensibilidade e Especificidade , Estatística como Assunto
15.
J Surg Res ; 184(1): 705-13, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23731685

RESUMO

BACKGROUND: Activation of the P2X7 receptor on peripheral neurons causes the formation of pannexin pores, which allows the influx of calcium across the cell membrane. Polyethylene glycol (PEG) and methylene blue have previously been shown to delay Wallerian degeneration if applied during microsuture repair of the severed nerve. Our hypothesis is that by modulating calcium influx via the P2X7 receptor pathway, we could improve PEG-based axonal repair. The P2X7 receptor can be stimulated or inhibited using bz adenosine triphosphate (bzATP) or brilliant blue (FCF), respectively. METHODS: A single incision rat sciatic nerve injury model was used. The defect was repaired using a previously described PEG methylene blue fusion protocol. Experimental animals were treated with 100 µL of 100 µM FCF solution (n = 8) or 100 µL of a 30 µM bzATP solution (n = 6). Control animals received no FCF, bzATP, or PEG. Compound action potentials were recorded prior to transection (baseline), immediately after repair, and 21 d postoperatively. Animals underwent behavioral testing 3, 7, 14, and 21 d postoperatively. After sacrifice, nerves were fixed, sectioned, and immunostained to allow for counting of total axons. RESULTS: Rats treated with FCF showed an improvement compared with control at all time points (n = 8) (P = 0.047, 0.044, 0.014, and 0.0059, respectively). A statistical difference was also shown between FCF and bzATP at d 7 (P < 0.05), but not shown with d 3, 14, and 21 (P > 0.05). CONCLUSIONS: Blocking the P2X7 receptor improves functional outcomes after PEG-mediated axonal fusion.


Assuntos
Procedimentos Neurocirúrgicos , Antagonistas do Receptor Purinérgico P2X/farmacologia , Receptores Purinérgicos P2X7/fisiologia , Neuropatia Ciática/tratamento farmacológico , Neuropatia Ciática/fisiopatologia , Potenciais de Ação/efeitos dos fármacos , Potenciais de Ação/fisiologia , Trifosfato de Adenosina/análogos & derivados , Trifosfato de Adenosina/farmacologia , Animais , Axônios/efeitos dos fármacos , Axônios/fisiologia , Benzenossulfonatos/farmacologia , Corantes/farmacologia , Portadores de Fármacos/farmacologia , Masculino , Atividade Motora/efeitos dos fármacos , Atividade Motora/fisiologia , Regeneração Nervosa/efeitos dos fármacos , Regeneração Nervosa/fisiologia , Inibidores da Agregação Plaquetária/farmacologia , Polietilenoglicóis/farmacologia , Ratos , Ratos Sprague-Dawley , Degeneração Walleriana/tratamento farmacológico , Degeneração Walleriana/fisiopatologia , Cicatrização/efeitos dos fármacos , Cicatrização/fisiologia
16.
Regen Med ; 18(5): 389-397, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-37158365

RESUMO

Aim: Repair of peripheral nerves is recommended following transection. Systematic evaluation of longitudinal recovery in injury models is needed to improve patient management. Gompertz function provided straightforward interpretation and prediction of recovery outcomes. Materials & methods: Behavioural sciatic function index, measured 3 days post injury, and weekly for 12 weeks following full nerve transection and repair (n = 6) as well as crush injuries (n = 6). Results: Gompertz parametrization provided early classification between types of traumatic peripheral nerve injuries following surgical repair. Results distinguished injury nerves (A: p < 0.01; Ti: p < 0.05; Ic: p < 0.05 and outcome: p < 0.01). Early prognostication of outcomes (crush: 5.5 ± 0.3 and cut/repair: 8 ± 1 weeks) preceded current methods. Conclusion: Our findings identify injury type, state of recovery and early prognostication of outcome.


Assuntos
Traumatismos dos Nervos Periféricos , Humanos , Traumatismos dos Nervos Periféricos/terapia , Nervo Isquiático , Regeneração Nervosa/fisiologia , Recuperação de Função Fisiológica/fisiologia
17.
Adv Sci (Weinh) ; : e2301232, 2023 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-37357139

RESUMO

Magnetic resonance imaging (MRI) is widely used in clinical care and medical research. The signal-to-noise ratio (SNR) in the measurement affects parameters that determine the diagnostic value of the image, such as the spatial resolution, contrast, and scan time. Surgically implanted radiofrequency coils can increase SNR of subsequent MRI studies of adjacent tissues. The resulting benefits in SNR are, however, balanced by significant risks associated with surgically removing these coils or with leaving them in place permanently. As an alternative, here the authors report classes of implantable inductor-capacitor circuits made entirely of bioresorbable organic and inorganic materials. Engineering choices for the designs of an inductor and a capacitor provide the ability to select the resonant frequency of the devices to meet MRI specifications (e.g., 200 MHz at 4.7 T MRI). Such devices enhance the SNR and improve the associated imaging capabilities. These simple, small bioelectronic systems function over clinically relevant time frames (up to 1 month) at physiological conditions and then disappear completely by natural mechanisms of bioresorption, thereby eliminating the need for surgical extraction. Imaging demonstrations in a nerve phantom and a human cadaver suggest that this technology has broad potential for post-surgical monitoring/evaluation of recovery processes.

18.
J Surg Res ; 177(2): 392-400, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22521220

RESUMO

BACKGROUND: Approximately 12% of operations for traumatic neuropathy are for patients with segmental nerve loss, and less than 50% of these injuries obtain meaningful functional recovery. Polyethylene glycol (PEG) therapy has been shown to improve functional outcomes after nerve severance, and we hypothesized this therapy could also benefit nerve autografting. METHODS: We used a segmental rat sciatic nerve injury model in which we repaired a 0.5-cm defect with an autograft using microsurgery. We treated experimental animals with solutions containing methylene blue (MB) and PEG; control animals did not receive PEG. We recorded compound action potentials (CAPs) before nerve transection, after solution therapy, and at 72 h postoperatively. The animals underwent behavioral testing at 24 and 72 h postoperatively. After we euthanized the animals, we fixed the nerves, sectioned and immunostained them to allow for quantitative morphometric analysis. RESULTS: The introduction of hydrophilic polymers greatly improved morphological and functional recovery of rat sciatic axons at 1-3 d after nerve autografting. Polyethylene glycol therapy restored CAPs in all animals, and CAPs were still present 72 h postoperatively. No CAPS were detectable in control animals. Foot Fault asymmetry scores and sciatic functional index scores were significantly improved for PEG therapy group at all time points (P < 0.05 and P < 0.001; P < 0.001 and P < 0.01). Sensory and motor axon counts were increased distally in nerves treated with PEG compared with control (P = 0.019 and P = 0.003). CONCLUSIONS: Polyethylene glycol therapy improves early physiologic function, behavioral outcomes, and distal axonal density after nerve autografting.


Assuntos
Regeneração Nervosa/efeitos dos fármacos , Transferência de Nervo , Polietilenoglicóis/uso terapêutico , Neuropatia Ciática/cirurgia , Tensoativos/uso terapêutico , Potenciais de Ação , Animais , Axônios/patologia , Comportamento Animal , Feminino , Pé/fisiologia , Polietilenoglicóis/farmacologia , Ratos , Ratos Sprague-Dawley , Nervo Isquiático/fisiologia , Tensoativos/farmacologia
19.
Ann Plast Surg ; 68(5): 518-24, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22531407

RESUMO

BACKGROUND AND PURPOSE: Improvement in axonal regeneration may lead to the development of longer nerve grafts and improved outcomes for patients with peripheral nerve injury. Although the use of acellular nerve grafts has been well documented (Groves et al, Exp Neurol. 2005;195:278-292; Krekoski et al, J Neurosci. 2001;21:6206-6213; Massey et al, Exp Neurol. 2008;209:426-445; Neubauer et al, Exp Neurol. 2007;207:163-170; Zuo et al, Exp Neurol. 2002;176:221-228), less is known about the ability of neurotrophic factors to enhance axonal regeneration. This study evaluates axonal ingrowth augmentation using acellular, chondroitinase-treated nerve grafts doped with nerve growth factor (NGF). METHODS: Acellular chondroitinase-treated murine nerve grafts were placed in experimental (NGF-treated grafts) and control (carrier-only grafts) rats. Five days after implantation, axonal regeneration was assessed by immunocytochemistry along with digital image analysis. RESULTS: Higher axon count was observed throughout the length of the nerve in the NGF group (P < 0.0001), peaking at 3 mm from proximal repair (P = 0.02). Although the NGF group displayed a higher axon count per slice, the mean diameter of individual NGF axons was smaller (P < 0.0001), potentially consistent with induction of sensory axons (Rich et al, J Neurocytol. 1987;16:261-268; Sofroniew et al, Annu Rev Neurosci. 2001;24:1217-1128; Yip et al, J Neurosci. 1984;4:2986-2992). CONCLUSION: The simple technique of doping acellular, chondroitinase-treated nerve grafts with NGF can augment axonal ingrowth and possibly preferentially induce sensory axons.


Assuntos
Axônios/fisiologia , Condroitina ABC Liase/administração & dosagem , Regeneração Tecidual Guiada/métodos , Fator de Crescimento Neural/administração & dosagem , Regeneração Nervosa , Nervo Isquiático/transplante , Engenharia Tecidual/métodos , Animais , Ensaio de Imunoadsorção Enzimática , Feminino , Masculino , Traumatismos dos Nervos Periféricos/cirurgia , Ratos , Ratos Sprague-Dawley , Nervo Isquiático/lesões , Nervo Isquiático/fisiologia
20.
Burns ; 48(8): 1885-1892, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35168857

RESUMO

INTRODUCTION: Delays in treatment of burn injuries can lead to significant morbidity, loss of function, and poor aesthetic appearance. Preventing conversion from partial- to full-thickness burns may help mitigate these sequelae. The pathophysiology of burn wound conversion remains unknown, but an overactive immune response is thought to be implicated. The purpose of this study was to determine whether downregulating the immune response via tacrolimus can decrease burn wound conversion. METHODS: Assembly of the microfluidic hydrogels was achieved by embedding microfibers within a hydrogel scaffold composed of a gelatin-alginate blend. Tacrolimus stock solution for intraperitoneal injection was made by re-suspending powdered tacrolimus in DMSO at 10 mg/mL. 24 young (2-4 months) and 24 old (>16 months) mice were given partial thickness burns. The treatment cohort received either tacrolimus ointment with a hydrogel dressing (6 young and 6 old) or an intraperitoneal injection of a tacrolimus solution (6 young and 6 old), while the control cohort only received either only the microcapillary hydrogel dressing or an intraperitoneal injection of saline. Mice were euthanized at day 3 after injury and skin samples were taken. Burn depth was evaluated using Vimentin immunostaining. RESULTS: In old mice, intraperitoneal injection of tacrolimus was able to significantly reduce burn wound depth compared to intraperitoneal injection of saline (p = 0.011). Similarly in old mice, topical hydrogel with tacrolimus was able to significantly reduce burn wound depth compared to hydrogel alone (p < 0.001). Topical hydrogel with tacrolimus was able to mitigate the detrimental effects of older age on wound conversion, such that burn wounds of older mice treated with tacrolimus hydrogel dressing had similar burn depths as younger mice (p = 0.240). CONCLUSIONS: Utilizing a combination treatment of tacrolimus and microcapillary hydrogel is able to rescue the negative effects of aging and prevent partial- to full-thickness burn wound conversion. Hopefully these findings will encourage deeper investigation into the possible therapeutic advantages of utilizing immunosuppressive agents to decrease morbidity after burn injuries. Future research will need to specifically investigate IL-2 as an inhibitory target in the acute inflammatory cascade of burn injury.


Assuntos
Queimaduras , Hidrogéis , Camundongos , Animais , Hidrogéis/uso terapêutico , Queimaduras/tratamento farmacológico , Tacrolimo/farmacologia , Tacrolimo/uso terapêutico , Cicatrização , Bandagens , Envelhecimento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA