RESUMO
The severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) pandemic has created a public crisis. Many medical and public institutions and businesses went into isolation in response to the pandemic. Because SARS-CoV-2 can spread irrespective of a patient's course of disease, these institutions' continued operation or reopening based on the assessment and control of virus spread can be supported by targeted population screening. For this purpose, virus testing in the form of polymerase chain reaction (PCR) analysis and antibody detection in blood can be central. Mobile SARS-CoV-2 screening facilities with a built-in biosafety level (BSL)-2 laboratory were set up to allow the testing offer to be brought close to the subject group's workplace. University staff members, their expertise, and already available equipment were used to implement and operate the screening facilities and a certified diagnostic laboratory. This operation also included specimen collection, transport, PCR and antibody analysis, and informing subjects as well as public health departments. Screening facilities were established at different locations such as educational institutions, nursing homes, and companies providing critical supply chains for health care. Less than 4 weeks after the first imposed lockdown in Germany, a first mobile testing station was established featuring a build-in laboratory with two similar stations commencing operation until June 2020. During the 15-month project period, approximately 33,000 PCR tests and close to 7000 antibody detection tests were collected and analyzed. The presented approach describes the required procedures that enabled the screening facilities and laboratories to collect and process several hundred specimens each day under difficult conditions. This report can assist others in establishing similar setups for pandemic scenarios.
RESUMO
Despite lockdown measures, intense symptom-based PCR, and antigen testing, the SARS-CoV-2 pandemic spread further. In this open observational study conducted in Lower Saxony, Germany, voluntary SARS-CoV-2 PCR tests were performed from April 2020 until June 2021, supported by serum antibody testing to prove whether PCR testing in subjects with none or few symptoms of COVID-19 is a suitable tool to manage the pandemic. In different mobile stations, 4,817 subjects from three different working fields participated in the PCR testing. Serum antibody screening using the SARS-CoV-2 ViraChip IgG (Viramed, Germany) and the Elecsys Anti-SARS-CoV-2 assay (Roche, Germany) was performed alongside virus neutralization testing. Subjects were questioned regarding comorbidities and COVID-19 symptoms. Fifty-one subjects with acute SARS-CoV-2 infection were detected of which 31 subjects did not show any symptoms possibly characteristic for COVID-19. An additional 37 subjects reported a previous SARS-CoV-2 infection (total prevalence 1.82%). Seroconversion was discovered in 58 subjects with known SARS-CoV-2 infection and in 58 subjects that never had a positive PCR test. The latter had a significantly lower Charlson Comorbidity Index, and one third of them were asymptomatic. In 50% of all seroconverted subjects, neutralizing serum antibodies (NAbs) were detectable in parallel to N/S1 (n = 16) or N/S1/S2 antigen specific antibodies (n = 40) against SARS-CoV-2. NAb titers decreased within 100 days after PCR-confirmed SARS-CoV-2 acute infection by at least 2.5-fold. A relatively high rate of subclinical SARS-CoV-2 infections may contribute to the spread of SARS-CoV-2, suggesting that in addition to other intervention strategies, systematic screening of asymptomatic persons by PCR testing may significantly enable better pandemic control. IMPORTANCE Within this open observational study, repeated PCR (n > 4,700) and antibody screening (n > 1,600) tests were offered in three different working fields. The study identified 51 subjects with acute SARS-CoV-2 infection and 37 subjects reported to have had a positive PCR test taken externally. Thirty-one of the 51 subjects did not display any symptoms prior to testing. In addition, 58 subjects without PCR-confirmed SARS-CoV-2 infection were identified by seroconversion. Subjects, that had undergone SARS-CoV-2 infection without having noticed, more often had a low grade of immunization with no NAbs, but may have relevantly contributed to the spread of the pandemic. Based on these results, we suggest that both regular PCR and rapid test screening of symptomatic and asymptomatic individuals, specifically within groups or workplaces identifiable as having close quarter contact, thus increased infection transference risk, is necessary to better assess and therefore reduce the spread of a pandemic virus.
Assuntos
Anticorpos Antivirais/sangue , COVID-19/epidemiologia , COVID-19/virologia , SARS-CoV-2/genética , SARS-CoV-2/imunologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Doenças Assintomáticas , COVID-19/sangue , Teste Sorológico para COVID-19 , Alemanha/epidemiologia , Humanos , Masculino , Pessoa de Meia-Idade , Reação em Cadeia da Polimerase , Estudos Prospectivos , SARS-CoV-2/isolamento & purificação , SARS-CoV-2/fisiologia , Soroconversão , Adulto JovemRESUMO
PURPOSE: The COVID-19 pandemic affects students in a myriad of different ways. Our prospective, longitudinal study in a cohort of students in Hannover, Germany explores behavioral patterns during escalating COVID-19 restrictions. METHODS: In total, 777 students between the age of 9 and 20 were assessed for their activity engagement, travel patterns, and self-assessed compliance with protective recommendations at six time points between June 2020 and June 2021 (3,564 observations) and were monitored for severe acute respiratory syndrome coronavirus 2 infection by nasal swab polymerase chain reaction and serum antibody titers. RESULTS: Activity engagement decreased, but self-assessed compliance with measures such as mask wearing and social distancing was stable during escalating restrictions. Although we found no sex difference during the summer break, when incidence was lowest, females engaged in a higher variety of activities than males for all other time points. Older students engaged in more activities and self-assigned themselves lower compliance values than younger ones. Greater involvement in different activities was seen in households which traveled more frequently. Infection rate in our cohort was low (0.03% acute infections, 1.94% positive seroprevalence). DISCUSSION: Our study supports the view that, overall, students show high compliance with COVID-19 recommendations and restrictions. The identification of subsets, such as female and older students, with higher risk behavioral patterns should be considered when implementing public information campaigns. In light of the low infection rate in our cohort, we conclude that in-person learning can occur safely if extensive protective measures are in place and the incidence in the general population remains moderate.
Assuntos
COVID-19 , Adolescente , Criança , Feminino , Humanos , Estudos Longitudinais , Masculino , Pandemias , Estudos Prospectivos , SARS-CoV-2 , Estudos SoroepidemiológicosRESUMO
BACKGROUND: Detection of seroconversion after SARS-CoV-2-infection or vaccination is relevant to discover subclinical cases and recognize patients with a possible immunity. OBJECTIVES: Test performance, effects of age, time-point of seroconversion and immune status regarding neutralizing antibodies (NAbs) and T-cell-reactivity were investigated. STUDY DESIGN: Two antibody assays (Viramed-Test for S/N-specific IgG, Roche-Test for N-specific IgA, -M, -G) were evaluated with classified samples. In total, 381 subjects aged 6-99 years, who had either recovered from the disease or had been vaccinated, were screened for SARS-CoV-2-specific antibodies. This screening was part of an open observational study with working adults. Additionally, children and adults were analyzed in a longitudinal COVID-19 study in schools. For immunity evaluation, virus neutralization tests and ELISpot tests were performed in a subgroup of subjects. RESULTS: Viramed revealed a slightly lower test performance than Roche, but test quality was equally well in samples from very young or very old donors. The time-point of seroconversion after the respective immunization detected by the two tests was not significantly different. N-specific antibodies, detected with Roche, highly correlated with NAbs in recovered subjects, whereas a positive Viramed-Test result was paralleled by a positive ELISpot result. CONCLUSION: Viramed-Test was not as sensitive as Roche-Test, but highly specific and beneficial to distinguish between recovered and vaccinated status. For both tests correlations with humoral and cellular immunity were found. Of note, the expected early detection of IgA and IgM by the Roche-Test did not prove to be an advantage over IgG testing by Viramed.
Assuntos
COVID-19 , SARS-CoV-2 , Adulto , Criança , Humanos , COVID-19/diagnóstico , Sensibilidade e Especificidade , Anticorpos Antivirais , Anticorpos Neutralizantes , Imunoglobulina G , Imunoglobulina ARESUMO
PURPOSE: In literature, many studies compare survival rates of different types of FPDs. Most of them compared restorations, which originated from one university, but from different clinicians. Data about restoration survival rates by only one experienced dentist are very rare. The aim of this study was to evaluate the survival rate of allceramic FPDs without the blurring effects of different clinicians. MATERIALS AND METHODS: 153 veneeredzirconia FPDs were observed for follow-up. 22 patients received 131 single crowns and 22 bridges. Because of the different bridge lengths, one unit was defined as a restored or replaced tooth. In total, 201 units were included. Only the restorations performed by the same clinician and produced in the same dental laboratory from 2011 to 2016 were included. Considered factors were defined as "type of unit", "type of abutment", "intraoral region", and "vitality". Modified UHPHS criteria were used for evaluation. Statistical analysis was performed using cox-regression. RESULTS: 189 units (94.0%) showed no kind of failure. 5 chippings (2.4%) could be corrected by intraoral polishing. 4 units (1.9%) exhibited spontaneous decementation. These polishable and recementable restorations are still in clinical use. Chippings or decementations, which lead to total failure, did not occur. One unit was completely fractured (0.5 %). Biological failures (caries, periodontitis or periimplantitis) did not occur. The statistical analysis of the factors did not reveal any significant differences. CONCLUSION: Modern all-ceramic FPDs seem to be an appropriate therapy not only for single restorations but for complex occlusal rehabilitations.
RESUMO
PURPOSE: Plasma activation of hydrophobic zirconia surfaces might be suitable to improve the bond strength of luting materials. The aim of this study was to analyze the influence of nonthermal argon-plasma on the shear bond strength (SBS) between zirconia and different combinations of 10-MDP adhesive systems and luting composites after artificial aging. MATERIALS AND METHODS: Two hundred forty Y-TZP specimens were ground automatically with 165 µm grit and water cooling. Half of the specimens received surface activation with nonthermal argon-plasma. The specimens were evenly distributed into three groups according to the adhesive systems ([Futurabond U, Futurabond M, Futurabond M + DCA], VOCO GmbH, Germany, Cuxhaven) and into further two subgroups according to the luting materials ([Bifix SE, Bifix QM], VOCO GmbH). Each specimen underwent artificial aging by thermocycling and water storage. SBS was measured in a universal testing machine. Statistical analysis was performed using ANOVA and Scheffè procedure with the level of significance set to 0.05. RESULTS: Surface activation with nonthermal plasma did not improve the bond strength between zirconia and the tested combinations of adhesive systems and luting materials. The plasma-activation trended to reveal higher bond strength if the self-etch luting material (Bifix SE) was used, irrespective of the adhesive system. CONCLUSION: Plasma-activation seems to be suitable to improve bond strength between zirconia and self-etch resin materials. However, further research is necessary to identify the influence of varying plasma-parameters.
RESUMO
PURPOSE: Fractures, occlusal adjustments, or marginal corrections after removing excess composite cements result in rough surfaces of all-ceramic FPDs. These have to be polished to prevent damage of the surrounding tissues. The aim of this study was to evaluate the roughness of zirconia, silicate-ceramic, and composite after polish with different systems for intraoral use. MATERIALS AND METHODS: Each set of 50 plates was made of zirconia, silicate-ceramic, and composite. All plates were ground automatically and were divided into 15 groups according to the treatment. Groups Zgrit, Sgrit, and Cgrit received no further treatment. Groups Zlab and Slab received glaze-baking, and group Clab was polished with a polishing device. In the experimental groups Zv, Sv, Cv, Zk, Sk, Ck, Zb, Sb, and Cb, the specimens were polished with ceramic-polishing systems "v", "k", and "b" for intraoral use. Roughness was measured using profilometry. Statistical analysis was performed with ANOVA and Scheffé-procedure with the level of significance set at P=.05. RESULTS: All systems reduced the roughness of zirconia, but the differences from the controls Zgrit and Zlab were not statistically significant (P>.907). Roughness of silicate ceramic was reduced only in group Sv, but it did not differ significantly from both controls (P>.580). Groups Cv, Ck, and Cb had a significantly rougher surface than that of group Clab (P<.003). CONCLUSION: Ceramic materials can be polished with the tested systems. Polishing of interface areas between ceramic and composite material should be performed with polishing systems for zirconia first, followed by systems for veneering materials and for composite materials.
RESUMO
BACKGROUND: Every endosseous dental implant is dependent on an adequate amount and quality of peri-implant hard and soft tissues and their fully functional interaction. The dental implant could fail in cases of insufficient bone and soft tissues or due to a violation of the soft to hard tissues to implant shoulder interface with arising of a secondary bone loss. METHOD: To overcome this biological weak-spot, we designed a new implant that allows for multi vector endosseous anchorage around the individual underlying bone, which has to be scanned by computed tomography (CT) or Cone beam CT (CBCT) technique to allow for planning the implant. We developed a workflow to digitally engineer this customized implant made up of two planning steps. First, the implant posts are designed by prosthodontic-driven backward planning, and a wireframe-style framework is designed on the individual bony surface of the recipient site. Next, the two pieces are digitally fused and manufactured as a single piece implant using the SLM technique (selective laser melting) and titanium-alloy-powder. RESULTS: Preoperative FEM-stress-test of the individual implant is possible before it is inserted sterile in an out-patient procedure. CONCLUSION: Unlike any other historical or current dental implant protocol, our newly developed "individual patient solutions dental" follows the principle of a fully functional and rigid osteosynthesis technology and offers a quick solution for an implant-borne dental rehabilitation in difficult conditions of soft and hard tissues.
Assuntos
Implantação Dentária Endóssea/métodos , Implantes Dentários , Planejamento de Prótese Dentária/métodos , Imageamento Tridimensional , Procedimentos de Ancoragem Ortodôntica/métodos , Análise do Estresse Dentário , Humanos , Cuidados Pré-Operatórios/métodos , Estudos de Amostragem , Sensibilidade e Especificidade , TitânioRESUMO
PURPOSE: Temperature increase of 5.5 â can cause damage or necrosis of the pulp. Increasing temperature can be caused not only by mechanical factors, e.g. grinding, but also by exothermic polymerization reactions of resin materials. The aim of this study was to evaluate influences of the form material on the intrapulpal temperature during the polymerization of different self-curing resin materials for temporary restorations. MATERIALS AND METHODS: 30 provisonal bridges were made of 5 resin materials: Prevision Temp (Pre), Protemp 4 (Pro), Luxatemp Star (Lux), Structure 3 (Str) and an experimental material (Exp). Moulds made of alginate (A) and of silicone (S) and vacuum formed moulds (V) were used to build 10 bridges each on a special experimental setup. The intrapulpal temperatures of three abutment teeth (a canine, a premolar, and a molar,) were measured during the polymerization every second under isothermal conditions. Comparisons of the maximum temperature (TMax) and the time until the maximum temperature (tTMax) were performed using ANOVA and Tukey Test. RESULTS: Using alginate as the mould material resulted in a cooling effect for every resin material. Using the vacuum formed mould, TMax increased significantly compared to alginate (P<.001) and silicone (P<.001). In groups Lux, Pro, and Pre, tTMax increased when the vacuum formed moulds were used. In groups Exp and Str, there was no influence of the mould material on tTMax. CONCLUSION: All of the mould materials are suitable for clinical use if the intraoral application time does not exceed the manufacturer's instructions for the resin materials.
RESUMO
OBJECTIVES: Numerous procedures including soft and hard tissue reconstructions are necessary to allow for final implant-borne dental rehabilitation in patients with severe alveolar atrophy or resected jaws. In these cases, customised digitally engineered patient solutions for fixed or removable dental rehabilitation provide an innovative line extension to conventional implant dentistry. MATERIAL AND METHODS: A wax-up was performed on plaster models that were scanned by 3D laser. The generated stereolithographic files were then fused with the preoperative 3D imaging data. The individualised "dental" patient solutions were designed digitally and comprised a skeletonised anchorage system and a suprastructure connection system. Insertion of the implants was performed on an outpatient basis. Conventional implant-supported prosthodontic rehabilitation was performed. RESULTS: This digital planning algorithm can be applied to manufacture individualised patient solutions. Similar to conventional implant-supported dentures, these implants can be equipped with individual suprastructure connection systems for internal conical connection, ball-retained attachment, and external conical (telescopic) connection. CONCLUSIONS: In patients with severe atrophy or resected jaws, particularly following ablative tumour surgery, customised digitally engineered solutions allow for an innovative, less invasive line extension to conventional implant dentistry. When conventional implant dentistry reaches its limits, they still offer a strategy for implant-borne dental rehabilitation.