Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 68
Filtrar
1.
Magn Reson Med ; 86(3): 1194-1211, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33847012

RESUMO

PURPOSE: A standard MRI system phantom has been designed and fabricated to assess scanner performance, stability, comparability and assess the accuracy of quantitative relaxation time imaging. The phantom is unique in having traceability to the International System of Units, a high level of precision, and monitoring by a national metrology institute. Here, we describe the phantom design, construction, imaging protocols, and measurement of geometric distortion, resolution, slice profile, signal-to-noise ratio (SNR), proton-spin relaxation times, image uniformity and proton density. METHODS: The system phantom, designed by the International Society of Magnetic Resonance in Medicine ad hoc committee on Standards for Quantitative MR, is a 200 mm spherical structure that contains a 57-element fiducial array; two relaxation time arrays; a proton density/SNR array; resolution and slice-profile insets. Standard imaging protocols are presented, which provide rapid assessment of geometric distortion, image uniformity, T1 and T2 mapping, image resolution, slice profile, and SNR. RESULTS: Fiducial array analysis gives assessment of intrinsic geometric distortions, which can vary considerably between scanners and correction techniques. This analysis also measures scanner/coil image uniformity, spatial calibration accuracy, and local volume distortion. An advanced resolution analysis gives both scanner and protocol contributions. SNR analysis gives both temporal and spatial contributions. CONCLUSIONS: A standard system phantom is useful for characterization of scanner performance, monitoring a scanner over time, and to compare different scanners. This type of calibration structure is useful for quality assurance, benchmarking quantitative MRI protocols, and to transition MRI from a qualitative imaging technique to a precise metrology with documented accuracy and uncertainty.


Assuntos
Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Imagens de Fantasmas , Razão Sinal-Ruído
2.
Kidney Int ; 98(1): 51-53, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32571489

RESUMO

Mitochondrial dysfunction is thought to be a critical pathway in the development and progression of kidney diseases, but optimal methods to assess kidney mitochondrial dysfunction are not well known. Saeki and colleagues use positron emission tomography imaging with a novel probe, 2-tert-butyl-4-chloro-5-[6-(4-18F-fluorobutoxy)-pyridin-3-ylmethoxy]-2H-pyridazin-3-one (18F-BCPP-BF), to visualize and assess kidney mitochondrial status. The authors demonstrate that reduced uptake of 18F-BCPP-BF, as assessed by positron emission tomography imaging, corresponds to reduced functioning mitochondria in 3 separate animal models of kidney diseases.


Assuntos
Complexo I de Transporte de Elétrons , Piridazinas , Animais , Encéfalo , Complexo I de Transporte de Elétrons/metabolismo , Mitocôndrias/metabolismo , Tomografia por Emissão de Pósitrons , Piridazinas/metabolismo , Piridinas , Compostos Radiofarmacêuticos/metabolismo
3.
Kidney Int ; 98(3): 579-589, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32739206

RESUMO

Diabetic kidney disease is the most common cause of end-stage kidney disease and poses a major global health problem. Finding new, safe, and effective strategies to halt this disease has proven to be challenging. In part that is because the underlying mechanisms are complex and not fully understood. However, in recent years, evidence has accumulated suggesting that chronic hypoxia may be the primary pathophysiological pathway driving diabetic kidney disease and chronic kidney disease of other etiologies and was called the chronic hypoxia hypothesis. Hypoxia is the result of a mismatch between oxygen delivery and oxygen demand. The primary determinant of oxygen delivery is renal perfusion (blood flow per tissue mass), whereas the main driver of oxygen demand is active sodium reabsorption. Diabetes mellitus is thought to compromise the oxygen balance by impairing oxygen delivery owing to hyperglycemia-associated microvascular damage and exacerbate oxygen demand owing to increased sodium reabsorption as a result of sodium-glucose cotransporter upregulation and glomerular hyperfiltration. The resultant hypoxic injury creates a vicious cycle of capillary damage, inflammation, deposition of the extracellular matrix, and, ultimately, fibrosis and nephron loss. This review will frame the role of chronic hypoxia in the pathogenesis of diabetic kidney disease and its prospect as a promising therapeutic target. We will outline the cellular mechanisms of hypoxia and evidence for renal hypoxia in animal and human studies. In addition, we will highlight the promise of newer imaging modalities including blood oxygenation level-dependent magnetic resonance imaging and discuss salutary interventions such as sodium-glucose cotransporter 2 inhibition that (may) protect the kidney through amelioration of renal hypoxia.


Assuntos
Diabetes Mellitus Tipo 2 , Nefropatias Diabéticas , Hiperglicemia , Inibidores do Transportador 2 de Sódio-Glicose , Animais , Nefropatias Diabéticas/tratamento farmacológico , Nefropatias Diabéticas/etiologia , Nefropatias Diabéticas/prevenção & controle , Humanos , Hipoglicemiantes , Hipóxia/complicações , Rim , Inibidores do Transportador 2 de Sódio-Glicose/farmacologia , Inibidores do Transportador 2 de Sódio-Glicose/uso terapêutico
4.
Am J Nephrol ; 51(12): 966-974, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33508835

RESUMO

BACKGROUND: The estimated glomerular filtration rate (eGFR) is frequently used to monitor progression of kidney disease. Multiple values have to be obtained, sometimes over years to determine the rate of decline in kidney function. Recent data suggest that functional MRI (fMRI) methods may be able to predict loss of eGFR. In a prior study, baseline data with multi-parametric MRI in individuals with diabetes and moderate CKD was reported. This report extends our prior observations in order to evaluate the temporal variability of the fMRI measurements over 36 months and their association with annual change in eGFR. METHODS: Twenty-four subjects with moderate CKD completed 3 sets of MRI scans over a 36-month period. Blood oxygenation level-dependent (BOLD), arterial spin labeling perfusion, and diffusion MRI images were acquired using a 3 T scanner. Coefficients of variation was used to evaluate variability between subjects at each time point and temporal variability within each subject. We have conducted mixed effects models to examine the trajectory change in GFR over time using time and MRI variables as fixed effects and baseline intercept as random effect. Associations of MRI image markers with annual change in eGFR were evaluated. RESULTS: Multi-parametric functional renal MRI techniques in individuals with moderate CKD showed higher temporal variability in R2* of medulla compared to healthy individuals. This was consistent with the significant lower R2* in medulla observed at 36 months compared to baseline values. The results of linear mixed model showing that R2*_Medulla was the only predictor associated with change in eGFR over time. Furthermore, a significant association of medullary R2* with annual loss of eGFR was observed at all the 3 time points. CONCLUSIONS: The lower R2* values and the higher temporal variability in the renal medulla over time suggest the ability to monitor progressive CKD. These were confirmed by the fact that reduced medullary R2* was associated with higher annual loss in eGFR. These data collectively emphasize the need for inclusion of medulla in the analysis of renal BOLD MRI studies.


Assuntos
Medula Renal/irrigação sanguínea , Imageamento por Ressonância Magnética , Oxigênio/sangue , Insuficiência Renal Crônica/sangue , Insuficiência Renal Crônica/diagnóstico por imagem , Idoso , Progressão da Doença , Feminino , Taxa de Filtração Glomerular , Humanos , Masculino , Pessoa de Meia-Idade , Insuficiência Renal Crônica/fisiopatologia , Índice de Gravidade de Doença , Fatores de Tempo
5.
MAGMA ; 33(1): 163-176, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31758418

RESUMO

To develop technical recommendations on the acquisition and post-processing of renal longitudinal (T1) and transverse (T2) relaxation time mapping. A multidisciplinary panel consisting of 18 experts in the field of renal T1 and T2 mapping participated in a consensus project, which was initiated by the European Cooperation in Science and Technology Action PARENCHIMA CA16103. Consensus recommendations were formulated using a two-step modified Delphi method. The first survey consisted of 56 items on T1 mapping, of which 4 reached the pre-defined consensus threshold of 75% or higher. The second survey was expanded to include both T1 and T2 mapping, and consisted of 54 items of which 32 reached consensus. Recommendations based were formulated on hardware, patient preparation, acquisition, analysis and reporting. Consensus-based technical recommendations for renal T1 and T2 mapping were formulated. However, there was considerable lack of consensus for renal T1 and particularly renal T2 mapping, to some extent surprising considering the long history of relaxometry in MRI, highlighting key knowledge gaps that require further work. This paper should be regarded as a first step in a long-term evidence-based iterative process towards ever increasing harmonization of scan protocols across sites, to ultimately facilitate clinical implementation.


Assuntos
Rim/diagnóstico por imagem , Imageamento por Ressonância Magnética/tendências , Nefrologia/tendências , Pesquisa Translacional Biomédica/tendências , Consenso , Técnica Delphi , Humanos , Comunicação Interdisciplinar , Imageamento por Ressonância Magnética/instrumentação , Inquéritos e Questionários
6.
MAGMA ; 33(1): 199-215, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31768797

RESUMO

Harmonization of acquisition and analysis protocols is an important step in the validation of BOLD MRI as a renal biomarker. This harmonization initiative provides technical recommendations based on a consensus report with the aim to move towards standardized protocols that facilitate clinical translation and comparison of data across sites. We used a recently published systematic review paper, which included a detailed summary of renal BOLD MRI technical parameters and areas of investigation in its supplementary material, as the starting point in developing the survey questionnaires for seeking consensus. Survey data were collected via the Delphi consensus process from 24 researchers on renal BOLD MRI exam preparation, data acquisition, data analysis, and interpretation. Consensus was defined as ≥ 75% unanimity in response. Among 31 survey questions, 14 achieved consensus resolution, 12 showed clear respondent preference (65-74% agreement), and 5 showed equal (50/50%) split in opinion among respondents. Recommendations for subject preparation, data acquisition, processing and reporting are given based on the survey results and review of the literature. These technical recommendations are aimed towards increased inter-site harmonization, a first step towards standardization of renal BOLD MRI protocols across sites. We expect this to be an iterative process updated dynamically based on progress in the field.


Assuntos
Rim/diagnóstico por imagem , Imageamento por Ressonância Magnética/tendências , Animais , Biomarcadores/metabolismo , Consenso , Técnica Delphi , Humanos , Rim/metabolismo , Imageamento por Ressonância Magnética/normas , Reprodutibilidade dos Testes , Razão Sinal-Ruído , Inquéritos e Questionários , Pesquisa Translacional Biomédica/tendências
7.
MAGMA ; 33(1): 141-161, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31833014

RESUMO

OBJECTIVES: This study aimed at developing technical recommendations for the acquisition, processing and analysis of renal ASL data in the human kidney at 1.5 T and 3 T field strengths that can promote standardization of renal perfusion measurements and facilitate the comparability of results across scanners and in multi-centre clinical studies. METHODS: An international panel of 23 renal ASL experts followed a modified Delphi process, including on-line surveys and two in-person meetings, to formulate a series of consensus statements regarding patient preparation, hardware, acquisition protocol, analysis steps and data reporting. RESULTS: Fifty-nine statements achieved consensus, while agreement could not be reached on two statements related to patient preparation. As a default protocol, the panel recommends pseudo-continuous (PCASL) or flow-sensitive alternating inversion recovery (FAIR) labelling with a single-slice spin-echo EPI readout with background suppression and a simple but robust quantification model. DISCUSSION: This approach is considered robust and reproducible and can provide renal perfusion images of adequate quality and SNR for most applications. If extended kidney coverage is desirable, a 2D multislice readout is recommended. These recommendations are based on current available evidence and expert opinion. Nonetheless they are expected to be updated as more data become available, since the renal ASL literature is rapidly expanding.


Assuntos
Circulação Cerebrovascular , Rim/diagnóstico por imagem , Imageamento por Ressonância Magnética/tendências , Marcadores de Spin , Pesquisa Translacional Biomédica/tendências , Algoritmos , Consenso , Técnica Delphi , Imagem Ecoplanar , Humanos , Processamento de Imagem Assistida por Computador/métodos , Rim/irrigação sanguínea , Transplante de Rim , Angiografia por Ressonância Magnética , Estudos Multicêntricos como Assunto , Perfusão , Artéria Renal/diagnóstico por imagem , Reprodutibilidade dos Testes , Razão Sinal-Ruído
8.
Am J Nephrol ; 49(2): 114-124, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30669143

RESUMO

BACKGROUND: Chronic hypoxia is a well-recognized factor in the pathogenesis of chronic kidney disease (CKD). Loss of microcirculation is thought to lead to enhanced renal hypoxia, which in turn results in the development of fibrosis, a hallmark of progressive CKD. To evaluate the role of functional magnetic resonance imaging (MRI), we performed perfusion, oxygenation, and diffusion MRI measurements in individuals with diabetes and stage 3 CKD. METHODS: Fifty-four subjects (41 individuals with diabetes and stage 3 CKD and 13 healthy controls) participated in this study. Data with blood oxygenation level dependent (BOLD), arterial spin labeling perfusion and diffusion MRI were acquired using a 3T scanner. RESULTS: Renal cortical perfusion was reduced in CKD compared to the controls (109.54 ± 25.38 vs. 203.17 ± 27.47 mL/min/100 g; p < 0.001). Cortical apparent diffusion coefficient showed no significant reduction in CKD compared to controls (1,596.10 ± 196.64 vs. 1,668.72 ± 77.29 × 10-6 mm2/s; p = 0.45) but was significantly associated with perfusion. Cortical R2* values were modestly increased in CKD (20.76 ± 4.08 vs. 18.74 ± 2.37 s-1; p = 0.12). Within the CKD group, R2*_Medulla and R2*_Kidney were moderately and negatively associated with estimated glomerular filtration rate. There was a significant association between cortical perfusion and medullary response to furosemide with annual loss of renal function, used as an estimate of CKD progression. CONCLUSIONS: Subjects with a moderate degree of CKD had significantly lower renal perfusion. Diffusion and BOLD MRI showed more modest differences between the groups. Individuals with progressive CKD had lower perfusion and response to furosemide.


Assuntos
Taxa de Filtração Glomerular/fisiologia , Córtex Renal/irrigação sanguínea , Túbulos Renais/fisiopatologia , Insuficiência Renal Crônica/fisiopatologia , Idoso , Hipóxia Celular , Imagem de Difusão por Ressonância Magnética , Progressão da Doença , Feminino , Furosemida/administração & dosagem , Taxa de Filtração Glomerular/efeitos dos fármacos , Humanos , Córtex Renal/diagnóstico por imagem , Túbulos Renais/diagnóstico por imagem , Túbulos Renais/efeitos dos fármacos , Angiografia por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Oxigênio/sangue , Consumo de Oxigênio/fisiologia , Insuficiência Renal Crônica/sangue , Insuficiência Renal Crônica/diagnóstico por imagem , Insuficiência Renal Crônica/tratamento farmacológico
9.
Kidney Int ; 93(4): 778-780, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29571450

RESUMO

Identifying subjects with progressive chronic kidney disease will be important both in clinical practice and in conducting clinical trials. Pruijm et al. (in this issue) demonstrate for the first time that cortical oxygenation as evaluated by blood oxygenation level-dependent magnetic resonance imaging can predict future loss of renal function. These observations provide the necessary stimulus to continue the development of renal blood oxygenation level-dependent magnetic resonance imaging to further improve the sensitivity and specificity to renal oxygenation and hence the predictive power.


Assuntos
Consumo de Oxigênio , Oxigênio , Humanos , Rim , Imageamento por Ressonância Magnética , Insuficiência Renal Crônica
10.
Radiology ; 286(1): 1-3, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-29261470

RESUMO

Functional magnetic resonance (MR) imaging of the kidneys has gained interest recently, especially in the detection of early changes in acute kidney injury or to predict progression of chronic kidney disease (CKD). The application of these methods to cardiorenal syndrome (CRS) is novel. CRS is widely accepted as a complex clinical problem routinely faced by clinicians. In this issue, Chang et al ( 1 ) present their preliminary experience applying blood oxygen level-dependent (BOLD) MR imaging to the kidneys in mice with experimental myocardial infarction. They showed that R2* in the kidney increases after induced myocardial infarction and that the response was higher in animals with larger infarcts and over time. The authors also for the first time correlated the BOLD MR imaging findings against hypoxia-inducible factor-1α (HIF-1α) expression, an independent marker of renal hypoxia. In addition, they showed evidence for renal injury by using a kidney injury marker, kidney injury molecule-1 (KIM-1). The results of their study support the use of renal BOLD MR imaging in subjects with heart failure, in whom the risk of subsequent renal ischemia and/or hypoxia is known to exist. These results, along with those of other recent reports ( 2 ), suggest that functional imaging methods could play a key role in evaluating changes in both the primary and secondary organs involved in complex disease processes such as CRS. Availability of such methods could facilitate translation to the clinic and improve the mechanistic understanding of the complicated and interrelated pathophysiology.


Assuntos
Síndrome Cardiorrenal/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Animais , Biomarcadores/análise , Insuficiência Cardíaca/diagnóstico por imagem , Receptor Celular 1 do Vírus da Hepatite A/metabolismo , Humanos , Camundongos , Oxigênio/sangue , Oxigênio/metabolismo , Insuficiência Renal Crônica/diagnóstico por imagem
11.
Am J Obstet Gynecol ; 218(5): 506.e1-506.e8, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29409786

RESUMO

BACKGROUND: The lack of noninvasive methods to study dysmenorrhea has resulted in poor understanding of the mechanisms underlying pain, insufficient diagnostic tests, and limited treatment options. To address this knowledge gap, we have developed a magnetic resonance imaging-based strategy for continuously monitoring the uterus in relationship to participants' spontaneous pain perception. OBJECTIVE: The study objective was to evaluate whether magnetic resonance imaging can detect real-time changes in myometrial activity during cramping episodes in women with dysmenorrhea, with a handheld squeeze bulb for pain reporting. STUDY DESIGN: Sixteen women with dysmenorrhea and 10 healthy control women both on and off their menses were evaluated with magnetic resonance imaging while not taking analgesic medication. Continuous magnetic resonance imaging was acquired using half-Fourier acquisition single-shot turbo spin echo sequence along with simultaneous reporting of pain severity with a squeeze bulb. Pearson's coefficient was used to compare results between reviewers. Proportional differences between women with dysmenorrhea and controls on/off menses were evaluated with a Fisher exact test. The temporal relationships between signal changes were evaluated with Monte Carlo simulations. RESULTS: Spontaneous progressive decreases in myometrial signal intensity were more frequently observed in women on their menses than in the absence of pain in the same women off their menses or participants without dysmenorrhea (P < .01). Women without reductions in myometrial signal intensity on their menses either had a history of endometriosis or were not in pain. Observations of myometrial events were consistently reported between 2 raters blinded to menstrual pain or day status (r = 0.97, P < .001). Episodes of cramping occurred either immediately before or 32-70 seconds after myometrial signal change onset (P < .05). CONCLUSION: Transient decreases in myometrial uterine T2-weighted signal intensity can be reliably measured in women with menstrual pain. The directionality of signal change and temporal relationship to pain onset suggest that cramping pain may be caused by a combination of uterine pressure and hemodynamic dysfunction.


Assuntos
Dismenorreia/diagnóstico por imagem , Cãibra Muscular/diagnóstico por imagem , Útero/diagnóstico por imagem , Adulto , Feminino , Humanos , Imagem Cinética por Ressonância Magnética , Menstruação , Percepção da Dor/fisiologia
12.
J Magn Reson Imaging ; 41(4): 1124-8, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24796852

RESUMO

PURPOSE: To investigate whether arterial spin labeling (ASL) MRI is sensitive to changes by pharmacologically induced vasodilation and vasoconstriction in rat kidneys. MATERIALS AND METHODS: Changes in renal cortical blood flow in seven rats were induced by adenosine infusion (vasodilation) and L-NAME injection (vasoconstriction). All imaging studies were performed on a 3 Tesla scanner using a FAIR-TrueFISP sequence for the ASL implementation. The acquisition time for each ASL scan was 6 min. Cortical perfusion rates were calculated using regions of interest analysis, and the differences in perfusion rates during baseline, vasodilation, and vasoconstriction were compared and assessed for statistical significance. RESULTS: Compared with the baseline, an average of 94 mL/100 g/min increase and 157 mL/100 g/min decrease in cortical perfusion was observed following adenosine infusion and L-NAME administration, respectively. The changes in cortical perfusion were significant between baseline and vasodilation (P < 0.05), baseline and vasoconstriction (P < 0.01), and vasodilation and vasoconstriction (P < 0.01). CONCLUSION: ASL is sensitive to pharmacologically induced perfusion changes in rat kidneys at doses comparable to current use. The preliminary results suggest the feasibility of ASL for investigating renal blood flow in a variety of rodent models.


Assuntos
Rim/fisiologia , Angiografia por Ressonância Magnética/métodos , Artéria Renal/fisiologia , Circulação Renal/fisiologia , Vasoconstritores/farmacologia , Vasodilatadores/farmacologia , Animais , Velocidade do Fluxo Sanguíneo/efeitos dos fármacos , Velocidade do Fluxo Sanguíneo/fisiologia , Rim/efeitos dos fármacos , Ratos , Ratos Sprague-Dawley , Artéria Renal/anatomia & histologia , Artéria Renal/efeitos dos fármacos , Circulação Renal/efeitos dos fármacos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Marcadores de Spin , Vasoconstrição/efeitos dos fármacos , Vasoconstrição/fisiologia , Vasodilatação/efeitos dos fármacos , Vasodilatação/fisiologia
13.
Kidney Int ; 85(4): 768-78, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24067433

RESUMO

Established as a method to study anatomic changes, such as renal tumors or atherosclerotic vascular disease, magnetic resonance imaging (MRI) to interrogate renal function has only recently begun to come of age. In this review, we briefly introduce some of the most important MRI techniques for renal functional imaging, and then review current findings on their use for diagnosis and monitoring of major kidney diseases. Specific applications include renovascular disease, diabetic nephropathy, renal transplants, renal masses, acute kidney injury, and pediatric anomalies. With this review, we hope to encourage more collaboration between nephrologists and radiologists to accelerate the development and application of modern MRI tools in nephrology clinics.


Assuntos
Nefropatias/diagnóstico , Imageamento por Ressonância Magnética/métodos , Nefrologia/tendências , Animais , Humanos
14.
Magn Reson Med ; 71(2): 570-9, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23447145

RESUMO

PURPOSE: To develop a navigator technique enabling free-breathing acquisition to afford sufficient signal averaging for quantitative renal perfusion measurement using arterial spin labeling MRI. METHODS: A novel two-dimensional (2D) navigator technique was implemented in concert with flow-sensitive alternating inversion recovery (FAIR) preparation and true fast imaging with steady precession (True-FISP) readout. The navigator images were obtained with a low-resolution fast low angle shot readout at end of each arterial spin labeling acquisition. A retrospective algorithm was developed to automatically detect respiratory motion for selective signal averaging. The 2D navigator-gated FAIR True-FISP sequence was performed in ten healthy volunteers and five patients with chronic kidney disease. RESULTS: Excellent image quality and comparable cortical perfusion rates (healthy: 276 ± 28 mL/100 g/min, patients: 155 ± 25 mL/100 g/min) to literature values were obtained. An average of 3-fold signal-to-noise ratio improvement was obtained in the 2D navigator-gated approach compared with the breath-hold acquisition in healthy volunteers. Good image quality was achieved in patients while the results from breath-hold acquisition were unusable. The quantitative perfusion rates were significantly lower in chronic kidney disease patients compared with the healthy volunteers. CONCLUSION: 2D navigator-gated free breathing arterial spin labeling is feasible and is a noninvasive method to evaluate renal perfusion both in healthy subjects and those with chronic kidney disease.


Assuntos
Rim/irrigação sanguínea , Imageamento por Ressonância Magnética/métodos , Imagem de Perfusão/métodos , Adulto , Algoritmos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Insuficiência Renal Crônica/fisiopatologia , Razão Sinal-Ruído , Marcadores de Spin
15.
J Magn Reson Imaging ; 39(4): 835-41, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24151096

RESUMO

PURPOSE: To evaluate longitudinal changes in renal oxygenation and diffusion measurements in a model of reversible unilateral ureteral obstruction (rUUO) which has been shown to induce chronic renal functional deficits in a strain dependent way. C57BL/6 mice show higher degree of functional deficit compared with BALB/c mice. Because hypoxia and development of fibrosis are associated with chronic kidney diseases and are responsible for progression, we hypothesized that MRI measurements would be able to monitor the longitudinal changes in this model and will show strain dependent differences in response. Here blood oxygenation level dependent (BOLD) and diffusion MRI measurements were performed at three time points over a 30 day period in mice with rUUO. MATERIALS AND METHODS: The studies were performed on a 4.7T scanner with the mice anesthetized with isoflurane before UUO, 2 and 28 days postrelease of 6 days of obstruction. RESULTS: We found at the early time point (∼2 days after releasing the obstruction), the relative oxygenation in C57Bl/6 mice were lower compared with BALB/c. Diffusion measurements were lower at this time point and reached statistical significance in BALB/c CONCLUSION: These methods may prove valuable in better understanding the natural progression of kidney diseases and in evaluating novel interventions to limit progression.


Assuntos
Modelos Animais de Doenças , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Oxigênio/sangue , Obstrução Ureteral/patologia , Obstrução Ureteral/fisiopatologia , Algoritmos , Animais , Humanos , Aumento da Imagem/métodos , Estudos Longitudinais , Camundongos , Camundongos Endogâmicos C57BL , Consumo de Oxigênio , Projetos Piloto , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
16.
Kidney Int Rep ; 8(5): 1057-1067, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37180507

RESUMO

Introduction: Kidney blood oxygenation level dependent (BOLD) magnetic resonance imaging (MRI) has shown great promise in evaluating relative oxygen availability. This method is quite efficacious in evaluating acute responses to physiological and pharmacologic maneuvers. Its outcome parameter, R2∗ is defined as the apparent spin-spin relaxation rate measured in the presence of magnetic susceptibility differences and it is measured using gradient echo MRI. Although associations between R2∗ and renal function decline have been described, it remains uncertain to what extent R2∗ is a true reflection of tissue oxygenation. This is primarily because of not taking into account the confounding factors, especially fractional blood volume (fBV) in tissue. Methods: This case-control study included 7 healthy controls and 6 patients with diabetes and chronic kidney disease (CKD). Using data before and after administration of ferumoxytol, a blood pool MRI contrast media, the fBVs in kidney cortex and medulla were measured. Results: This pilot study independently measured fBV in kidney cortex (0.23 ± 0.03 vs. 0.17 ± 0.03) and medulla (0.36 ± 0.08 vs. 0.25 ± 0.03) in a small number of healthy controls (n = 7) versus CKD (n = 6). These were then combined with BOLD MRI measurements to estimate oxygen saturation of hemoglobin (StO2) (0.87 ± 0.03 vs. 0.72 ± 0.10 in cortex; 0.82 ± 0.05 vs. 0.72 ± 0.06 in medulla) and partial pressure of oxygen in blood (bloodPO2) (55.4 ± 6.5 vs. 38.4 ± 7.6 mm Hg in cortex; 48.4 ± 6.2 vs. 38.1 ± 4.5 mm Hg in medulla) in control versus CKD. The results for the first time demonstrate that cortex is normoxemic in controls and moderately hypoxemic in CKD. In the medulla, it is mildly hypoxemic in controls and moderately hypoxemic in CKD. Whereas fBV, StO2, and bloodPO2 were strongly associated with estimated glomerular filtration rate (eGFR), R2∗ was not. Conclusion: Our results support the feasibility of quantitatively assessing oxygen availability using noninvasive quantitative BOLD MRI that could be translated to the clinic.

17.
Diagnostics (Basel) ; 13(13)2023 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-37443620

RESUMO

Because of the limited specificity of diagnostic imaging, many breast lesions referred for biopsy turn out to be benign. The objective of this study was to evaluate whether diffusion tensor MRI (DTI) parametric maps can be used to safely avoid biopsy of breast lesions. Individuals referred for breast biopsy based on mammogram (MG), ultrasound (US), and/or contrast enhanced (CE)-MRI were recruited. Scans consisting of T2-weighted and DTI sequences were performed. Multiple DTI-derived parametric color maps were evaluated semi-quantitatively to characterize lesions as "definitely benign," "not definitely benign," or "suspicious." All patients subsequently underwent biopsy. In this moderately-sized prospective study, 21 out of 47 pathologically proven benign lesions were characterized by both readers as "definitely benign," which would have precluded the need for biopsy. Biopsy was recommended for 11 out of 13 cancers that were characterized as "suspicious." In the remaining two cancers and 26 of 47 benign lesions, the scans were characterized as "not definitely benign" and hence required biopsy. The main causes for "not definitely benign" scans were small lesion sizes and noise. The results suggest that in appropriately selected patients, DTI may be used to safely reduce the number of unnecessary breast biopsies.

18.
J Orthop Res ; 41(6): 1206-1216, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36268875

RESUMO

We investigated whether baseline sagittal-plane ankle, knee, and hip contribution to the total support moment (TSM) are each associated with baseline-to-2-year tibiofemoral and patellofemoral tissue damage worsening in adults with knee osteoarthritis. Ambulatory lower-limb kinetics were captured and computed. TSM is the sum of ankle, knee, and hip extensor moments at each instant during gait. Ankle, knee, and hip contributions to TSM were computed as joint moments divided by TSM, expressed as percentages. Participants underwent MRI of both knees at baseline and 2 years later. Logistic regression models assessed associations of baseline ankle contribution to TSM with baseline-to-2-year cartilage damage and bone marrow lesion worsening, adjusted for age, sex, BMI, gait speed, disease severity, and pain. We used similar analytic approaches for knee and hip contributions to TSM. Sample included 391 knees from 204 persons (age[SD]: 64[10] years; 76.5% women). Greater ankle contribution may be associated with increased odds of tibiofemoral cartilage damage worsening (OR = 2.38; 95% CI: 1.02-5.57) and decreased odds of patellofemoral bone marrow lesion worsening (OR = 0.14; 95% CI: 0.03-0.73). The ORs for greater knee contribution were in the protective range for tibiofemoral compartment and in the deleterious range for patellofemoral. Greater hip contribution may be associated with increased odds of tibiofemoral worsening (OR = 2.71; 95% CI: 1.17-6.30). Greater ankle contribution to TSM may be associated with baseline-to-2-year tibiofemoral worsening, but patellofemoral tissue preservation. Conversely, greater knee contribution may be associated with patellofemoral worsening, but tibiofemoral preservation. Preliminary findings illustrate potential challenges in developing biomechanical interventions beneficial to both tibiofemoral and patellofemoral compartments.


Assuntos
Doenças Ósseas , Doenças das Cartilagens , Osteoartrite do Joelho , Humanos , Adulto , Feminino , Criança , Masculino , Osteoartrite do Joelho/diagnóstico por imagem , Osteoartrite do Joelho/patologia , Articulação do Joelho/patologia , Imageamento por Ressonância Magnética , Marcha , Doenças das Cartilagens/patologia
19.
J Magn Reson Imaging ; 36(5): 1162-7, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22826125

RESUMO

PURPOSE: To compare the effects of osmolality versus viscosity of radio-contrast media on intra-renal oxygenation as determined by blood oxygenation level-dependent (BOLD) MRI in a model of contrast induced nephropathy (CIN). MATERIALS AND METHODS: Twenty-four Sprague-Dawley rats were divided into five groups. Nitric oxide synthase inhibitor L-NAME (10 mg/kg), cyclooxygenase inhibitor indomethacin (10 mg/kg), or saline, and radio-contrast iodixanol (high viscosity, 784 or 1600 mg I/kg) or iothalamate (high osmolality, 1600 mg I/kg) were administered. BOLD MRI images were acquired on Siemens 3 Tesla (T) scanner using a multiple gradient recalled echo sequence at baseline, following L-NAME (or saline), indomethacin (or saline), and radio-contrast agents. R2* (=1/T2*) was used as the BOLD MRI parameter in renal medulla and cortex. Mixed-effects models with first order auto-regressive variance-covariance models were used to analyze the data. RESULTS: The magnitude of change in medullary R2* (MR2*) with same dose of iodine was larger with iodixanol compared with iothalalmate both in pretreated groups (303% versus 225.6%, < 0.01) and the control group (191.6% versus -1.8%, P < 0.01). The MR2* change in high dose iodixanol was approximately twice compared with the low dose (303% versus 133%, P < 0.01). CONCLUSION: The viscosity of radio-contrast seems to play a more significant role than osmolality in terms of renal oxygenation changes as evaluated by BOLD MRI. Additionally, iodixanol induced a dose-dependent increase in renal medullary hypoxia.


Assuntos
Nefropatias/sangue , Nefropatias/induzido quimicamente , Imageamento por Ressonância Magnética , Ácidos Tri-Iodobenzoicos/efeitos adversos , Ácidos Tri-Iodobenzoicos/química , Animais , Meios de Contraste/efeitos adversos , Meios de Contraste/química , Relação Dose-Resposta a Droga , Nefropatias/diagnóstico , Masculino , Concentração Osmolar , Oxigênio , Consumo de Oxigênio , Ratos , Ratos Sprague-Dawley , Viscosidade
20.
Front Pain Res (Lausanne) ; 3: 720141, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35634451

RESUMO

Women frequently report increased bloating, flatulence, and pain during the perimenstrual period. However, it is unknown whether women have more intraluminal gas during menses. To evaluate whether pain-free women or women with dysmenorrhea have different amounts of intraluminal bowel gas during the menses, we utilized magnetic resonance imaging (MRI) to determine colonic gas volumes throughout the menstrual cycle. To avoid dietary influence, the participants were instructed to avoid gas-producing foods before their scheduled MRI. We verified the measurement repeatability across the reviewers and obtained an intraclass correlation coefficient of 0.92. There were no significant differences in intraluminal gas volume between menses and non-menses scans (p = 0.679). Even among the women with dysmenorrhea, there was no significant difference in the intraluminal gas volume between menses and non-menses (p = 0.753). During menstruation, the participants with dysmenorrhea had less intraluminal gas than participants without dysmenorrhea (p = 0.044). However, the correlation between the bowel gas volume and the pain symptoms were not significant (p > 0.05). Although increased bowel symptoms and bloating are reported in the women with dysmenorrhea during menses, our results do not support the hypothesis that increased intraluminal gas is a contributing factor. Although dietary treatment has been shown in other studies to improve menstrual pain, the mechanism responsible for abdominal symptoms requires further investigation. Our findings demonstrate that the intraluminal bowel gas volume measurements are feasible and are unaffected by menses under a controlled diet. The method described might prove helpful in future mechanistic studies in clarifying the role of intraluminal bowel gas in other conditions.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA