Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
1.
Anal Chem ; 93(28): 9817-9825, 2021 07 20.
Artigo em Inglês | MEDLINE | ID: mdl-34213903

RESUMO

High-field asymmetric waveform ion mobility spectrometry (FAIMS) has gained popularity in the proteomics field for its capability to improve mass spectrometry sensitivity and to decrease peptide co-fragmentation. The recent implementation of FAIMS on Tribrid Orbitrap instruments enhanced proteome coverage and increased the precision of quantitative measurements. However, the FAIMS interface has not been available on older generation Orbitrap mass spectrometers such as the Q-Exactive. Here, we report the integration of the FAIMS Pro device with embedded electrical and gas connections to a Q-Exactive HF mass spectrometer. Proteomic experiments performed on HeLa tryptic digests with the modified mass spectrometer improved signal to noise and reduced interfering ions, resulting in an increase of 42% in peptide identification. FAIMS was also combined with segmented ion fractionation where 100 m/z windows were obtained in turn to further increase the depth of proteome analysis by reducing the proportion of chimeric MS/MS spectra from 50 to 27%. We also demonstrate the application of FAIMS to improve quantitative measurements when using isobaric peptide labeling. FAIMS experiments performed on a two-proteome model revealed that FAIMS Pro provided a 65% improvement in quantification accuracy compared to conventional LC-MS/MS experiments.


Assuntos
Proteômica , Espectrometria de Massas em Tandem , Cromatografia Líquida , Humanos , Espectrometria de Mobilidade Iônica , Íons
2.
Mol Cell Proteomics ; 17(10): 2051-2067, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-30007914

RESUMO

The depth of proteomic analyses is often limited by the overwhelming proportion of confounding background ions that compromise the identification and quantification of low abundance peptides. To alleviate these limitations, we present a new high field asymmetric waveform ion mobility spectrometry (FAIMS) interface that can be coupled to the Orbitrap Tribrid mass spectrometers. The interface provides several advantages over previous generations of FAIMS devices, including ease of operation, robustness, and high ion transmission. Replicate LC-FAIMS-MS/MS analyses (n = 100) of HEK293 protein digests showed stable ion current over extended time periods with uniform peptide identification on more than 10,000 distinct peptides. For complex tryptic digest analyses, the coupling of FAIMS to LC-MS/MS enabled a 30% gain in unique peptide identification compared with non-FAIMS experiments. Improvement in sensitivity facilitated the identification of low abundance peptides, and extended the limit of detection by almost an order of magnitude. The reduction in chimeric MS/MS spectra using FAIMS also improved the precision and the number of quantifiable peptides when using isobaric labeling with tandem mass tag (TMT) 10-plex reagent. We compared quantitative proteomic measurements for LC-MS/MS analyses performed using synchronous precursor selection (SPS) and LC-FAIMS-MS/MS to profile the temporal changes in protein abundance of HEK293 cells following heat shock for periods up to 9 h. FAIMS provided 2.5-fold increase in the number of quantifiable peptides compared with non-FAIMS experiments (30,848 peptides from 2,646 proteins for FAIMS versus 12,400 peptides from 1,229 proteins with SPS). Altogether, the enhancement in ion transmission and duty cycle of the new FAIMS interface extended the depth and comprehensiveness of proteomic analyses and improved the precision of quantitative measurements.


Assuntos
Espectrometria de Mobilidade Iônica/instrumentação , Proteoma/análise , Proteômica/instrumentação , Proteômica/métodos , Cromatografia Líquida , Células HEK293 , Resposta ao Choque Térmico , Humanos , Marcação por Isótopo , Estabilidade Proteica , Reprodutibilidade dos Testes , Espectrometria de Massas em Tandem
3.
Anal Chem ; 91(6): 4010-4016, 2019 03 19.
Artigo em Inglês | MEDLINE | ID: mdl-30672687

RESUMO

Multiplexed, isobaric tagging methods are powerful techniques to increase throughput, precision, and accuracy in quantitative proteomics. The dynamic range and accuracy of quantitation, however, can be limited by coisolation of tag-containing peptides that release reporter ions and conflate quantitative measurements across precursors. Methods to alleviate these effects often lead to the loss of protein and peptide identifications through online or offline filtering of interference containing spectra. To alleviate this effect, high-Field Asymmetric-waveform Ion Mobility Spectroscopy (FAIMS) has been proposed as a method to reduce precursor coisolation and improve the accuracy and dynamic range of multiplex quantitation. Here we tested the use of FAIMS to improve quantitative accuracy using previously established TMT-based interference standards (triple-knockout [TKO] and Human-Yeast Proteomics Resource [HYPER]). We observed that FAIMS robustly improved the quantitative accuracy of both high-resolution MS2 (HRMS2) and synchronous precursor selection MS3 (SPS-MS3)-based methods without sacrificing protein identifications. We further optimized and characterized the main factors that enable robust use of FAIMS for multiplexed quantitation. We highlight these factors and provide method recommendations to take advantage of FAIMS technology to improve isobaric-tag-quantification moving forward.


Assuntos
Espectrometria de Massas/métodos , Proteínas de Neoplasias/metabolismo , Peptídeos/análise , Proteoma/análise , Proteômica/métodos , Proteínas de Saccharomyces cerevisiae/metabolismo , Saccharomyces cerevisiae/metabolismo , Células HCT116 , Humanos , Peptídeos/metabolismo , Proteoma/metabolismo
4.
Anal Chem ; 90(15): 9529-9537, 2018 08 07.
Artigo em Inglês | MEDLINE | ID: mdl-29969236

RESUMO

Liquid chromatography (LC) prefractionation is often implemented to increase proteomic coverage; however, while effective, this approach is laborious, requires considerable sample amount, and can be cumbersome. We describe how interfacing a recently described high-field asymmetric waveform ion mobility spectrometry (FAIMS) device between a nanoelectrospray ionization (nanoESI) emitter and an Orbitrap hybrid mass spectrometer (MS) enables the collection of single-shot proteomic data with comparable depth to that of conventional two-dimensional LC approaches. This next generation FAIMS device incorporates improved ion sampling at the ESI-FAIMS interface, increased electric field strength, and a helium-free ion transport gas. With fast internal compensation voltage (CV) stepping (25 ms/transition), multiple unique gas-phase fractions may be analyzed simultaneously over the course of an MS analysis. We have comprehensively demonstrated how this device performs for bottom-up proteomics experiments as well as characterized the effects of peptide charge state, mass loading, analysis time, and additional variables. We also offer recommendations for the number of CVs and which CVs to use for different lengths of experiments. Internal CV stepping experiments increase protein identifications from a single-shot experiment to >8000, from over 100 000 peptide identifications in as little as 5 h. In single-shot 4 h label-free quantitation (LFQ) experiments of a human cell line, we quantified 7818 proteins with FAIMS using intra-analysis CV switching compared to 6809 without FAIMS. Single-shot FAIMS results also compare favorably with LC fractionation experiments. A 6 h single-shot FAIMS experiment generates 8007 protein identifications, while four fractions analyzed for 1.5 h each produce 7776 protein identifications.


Assuntos
Espectrometria de Mobilidade Iônica/instrumentação , Peptídeos/análise , Proteínas/análise , Proteômica/instrumentação , Espectrometria de Massas por Ionização por Electrospray/instrumentação , Linhagem Celular , Humanos
5.
Anal Chem ; 87(16): 8234-41, 2015 Aug 18.
Artigo em Inglês | MEDLINE | ID: mdl-26192074

RESUMO

Ion sampling from an electrospray ionization (ESI) source was improved by increasing gas conductance of the MS inlet by 4.3-fold. Converting the gas throughput (Q) into sensitivity improvement was dependent on ion desolvation and handling of the gas load. Desolvation was addressed by using a novel slot shaped inlet that exhibited desolvation properties identical to the 0.58 mm i.d capillary. An assay tailored for "small molecules" at high chromatographic flow rate (500 µL/min) yielded a compound dependent 6.5 to 14-fold signal gain while analysis at nano chromatographic flow rate (300 nL/min) showed 2 to 3.5-fold improvement for doubly charged peptides. Improvement exceeding the Q (4.3-fold) at high chromatographic flow rate was explained by superior sampling of the spatially dispersed ion spray when using the slot shaped capillary. Sensitivity improvement across a wide range of chromatographic flow rate confirmed no compromise in ion desolvation with the increase in Q. Another improvement included less overflow of gas into the mass analyzer from the foreline region owing to the slot shape of the capillary. By doubling the roughing pump capacity and operating the electrodynamic ion funnel (EDIF) at ∼4 Torr, a single pumping stage was sufficient to handle the gas load. The transport of solvent clusters from the LC effluent into the mass analyzer was prevented by a "wavy shaped" transfer quadrupole and was compared with a benchmark approach that delivered ions orthogonally into a differentially pumped dual EDIF at comparable gas Q.

7.
Anal Chem ; 83(6): 2162-71, 2011 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-21344863

RESUMO

Liquid chromatography (LC)-triple quadrupole mass spectrometers operating in a multiple reaction monitoring (MRM) mode are increasingly used for quantitative analysis of low-abundance analytes in highly complex biochemical matrixes. After development and selection of optimum MRM transitions, sensitivity and data quality limitations are largely related to mass spectral peak interferences from sample or matrix constituents and statistical limitations at low number of ions reaching the detector. Herein, we report on a new approach to enhancing MRM sensitivity by converting the continuous stream of ions from the ion source into a pulsed ion beam through the use of an ion funnel trap (IFT). Evaluation of the pulsed MRM approach was performed with a tryptic digest of Shewanella oneidensis strain MR-1 spiked with several model peptides. The sensitivity improvement observed with the IFT coupled in to the triple quadrupole instrument is based on several unique features. First, ion accumulation radio frequency (rf) ion trap facilitates improved droplet desolvation, which is manifested in the reduced background ion noise at the detector. Second, signal amplitude for a given transition is enhanced because of an order-of-magnitude increase in the ion charge density compared to a continuous mode of operation. Third, signal detection at the full duty cycle is obtained, as the trap use eliminates dead times between transitions, which are inevitable with continuous ion streams. In comparison with the conventional approach, the pulsed MRM signals showed 5-fold enhanced peak amplitude and 2-3-fold reduced chemical background, resulting in an improvement in the limit of detection (LOD) by a factor of ∼4-8.


Assuntos
Espectrometria de Massas em Tandem/métodos , Animais , Proteínas de Bactérias/química , Proteínas de Bactérias/metabolismo , Bovinos , Cromatografia Líquida , Condutividade Elétrica , Fragmentos de Peptídeos/química , Fragmentos de Peptídeos/metabolismo , Shewanella , Tripsina/metabolismo
8.
Anal Chem ; 81(21): 8749-57, 2009 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-19785446

RESUMO

A key application of field asymmetric waveform ion mobility spectrometry (FAIMS) has been in selectively transmitting trace analyte ions that are present in a complex ion mixture to a mass spectrometer (MS) for identification and quantification. The overall sensitivity of FAIMS-MS, however, still needs to be significantly improved through the optimization of ion transmission into FAIMS and at the FAIMS-MS interface. Processes that cause ion losses include diffusion, space charge, separation field in the FAIMS and fringe fields around the edges of the FAIMS electrodes. These were studied here by first developing an algorithm using SIMION as its core structure to compute ion trajectory at different ratios of electric field to buffer gas number density (E/N). The E/N was varied from a few Td to approximately 80 Td by using an asymmetric square waveform. The algorithm was then combined with statistical diffusion simulation (SDS) model, columbic repulsion, and a parabolic gas flow profile to realistically simulate current transmission and peak shape. The algorithm was validated using a FAIMS model identical to the Sionex Corporation SVAC model. Ions modeled included low mass ions with K(o) in the range of 2.17 (m = 55) to 1.39 cm(2) x V(-1) x s(-1) (m = 368). Good agreement was achieved between simulated and experimental CV (peak maxima) values, peak width (fwhm), and transmitted ion current I(output). The model was then used to study fringe fields in a simple arrangement where a 0.5 mm (w) gap was created between the FAIMS exit and a capillary inlet (i.d. = 0.5 mm). At an optimum CV (11.8 V), only approximately 17% (1.3 pA) of the total ion current that correlate to CV = 11.8 V, entered the capillary; bulk of the ion loss was caused by the fringe fields. Current transmission into the capillary was improved, however, by applying a 500 V DC bias across w (0.5 mm).


Assuntos
Íons/química , Espectrometria de Massas/métodos , Algoritmos , Eletrodos , Modelos Químicos
9.
Analyst ; 133(6): 760-7, 2008 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-18493677

RESUMO

Four bacteria, Escherichia coli, Pseudomonas aeruginosa, Staphylococcus warneri, and Micrococcus luteus, were grown at temperatures of 23, 30, and 37 degrees C and were characterized by pyrolysis-gas chromatography/differential mobility spectrometry (Py-GC/DMS) providing, with replicates, 120 data sets of retention time, compensation voltage, and ion intensity, each for negative and positive polarity. Principal component analysis (PCA) for 96 of these data sets exhibited clusters by temperature of culture growth and not by genus. Analysis of variance was used to isolate the constituents with dependences on growth temperature. When these were subtracted from the data sets, Fisher ratios with PCA resulted in four clusters according to genus at all temperatures for ions in each polarity. Comparable results were obtained from unsupervised PCA with 24 of the original data sets. The ions with taxonomic features were reconstructed into 3D plots of retention time, compensation voltage, and Fisher ratio and were matched, through GC-mass spectrometry (MS), with chemical standards attributed to the thermal decomposition of proteins and lipid A. Results for negative ions provided simpler data sets than from positive ions, as anticipated from selectivity of gas phase ion-molecule reactions in air at ambient pressure.


Assuntos
Bactérias/isolamento & purificação , Interpretação Estatística de Dados , Análise de Variância , Bactérias/classificação , Cromatografia Gasosa-Espectrometria de Massas/métodos , Análise de Componente Principal
10.
J Am Soc Mass Spectrom ; 28(3): 525-538, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28097537

RESUMO

The implementation of an aerodynamic mechanism to improve ion sampling between nanoelectrospray (n-ESI) and FAIMS was recently reported for proteomic analyses. This investigation explores the new FAIMS interface for small molecule analysis at high liquid flow rates and includes an examination of key differences in ionization between heated-ESI (HESI) and n-ESI. The sheath gas, critical for desolvation with HESI, affects FAIMS operation as higher FAIMS gas flow rates are required to achieve sufficient desolvation. Gas flow rate experiments also uncovered m/z discrimination with the conventional design as larger (slower moving) m/z ions experienced larger signal intensity losses than smaller m/z ions due to the desolvation gas flow having a greater drag effect on slower moving ions. The modified inlet in new FAIMS dampens the gas drag, making the HESI source more amenable as less m/z bias and significantly lower %RSD values were observed. Furthermore, a larger radius inner electrode in new FAIMS enables significantly higher E/N (electric field/number gas density) to be achieved using the existing waveform generator. Thus, new FAIMS signal intensities using only nitrogen improved 1.25- to 2-fold compared with the conventional design and 50% helium. Adding helium to the new FAIMS gave no significant improvements. The larger inner electrode also decreased ion focusing capabilities, and the effect on peak separation and ion intensity was examined in detail. The peak capacity of new FAIMS was approximately double that of conventional FAIMS; separation of seven low m/z ions gave a peak capacity of 37.7 using the gas additive 2-propanol. Graphical Abstract ᅟ.

11.
J Am Soc Mass Spectrom ; 25(12): 2143-53, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25267086

RESUMO

Simulations show that significant ion losses occur within the commercial electrospray ionization-field asymmetric waveform ion mobility spectrometer (ESI-FAIMS) interface owing to an angular desolvation gas flow and because of the impact of the FAIMS carrier gas onto the inner rf (radio frequency) electrode. The angular desolvation gas flow diverts ions away from the entrance plate orifice while the carrier gas annihilates ions onto the inner rf electrode. A novel ESI-FAIMS interface is described that optimizes FAIMS gas flows resulting in large improvements in transmission. Simulations with the bromochloroacetate anion showed an improvement of ~9-fold to give ~70% overall transmission). Comparable transmission improvements were attained experimentally for six peptides (2+) in the range of m/z 404.2 to 653.4 at a chromatographic flow rate of 300 nL/min. Selected ion chromatograms (SIC) from nano-LC-FAIMS-MS analyses showed 71% (HLVDEPQNLIK, m/z 653.4, 2+) to 95% (LVNELTEFAK, m/z 582.3, 2+) of ion signal compared with ion signal in the SIC from LC-MS analysis. IGSEVYHNLK (580.3, 2+) showed 24% more ion signal compared with LC-MS and is explained by enhanced desolvation in FAIMS. A 3-10 times lower limits of quantitation (LOQ) (<15% RSD) was achieved for chemical noise limited peaks with FAIMS. Peaks limited by ion statistics showed subtle improvement in RSD and yielded comparable LOQ to that attained with nano-LC-MS (without FAIMS). These improvements were obtained using a reduced FAIMS separation gap (from 2.5 to 1.5 mm) that results in a shorter residence time (13.2 ms ± 3.9 ms) and enables the use of a helium free transport gas (100% nitrogen).


Assuntos
Espectrometria de Massas por Ionização por Electrospray/instrumentação , Espectrometria de Massas por Ionização por Electrospray/métodos , Eletrodos , Desenho de Equipamento , Gases/química , Nanotecnologia/instrumentação , Peptídeos/química , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
12.
J Am Soc Mass Spectrom ; 25(7): 1274-84, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24796261

RESUMO

Recent reports describing enhanced performance when using gas additives in a DMS device (planar electrodes) have indicated that comparable benefits are not attainable using FAIMS (cylindrical electrodes), owing to the non-homogeneous electric fields within the analyzer region. In this study, a FAIMS system (having cylindrical electrodes) was modified to allow for controlled delivery of gas additives. An experiment was carried out that illustrates the important distinction between gas modifiers present as unregulated contaminants and modifiers added in a controlled manner. The effect of contamination was simulated by adjusting the ESI needle position to promote incomplete desolvation, thereby permitting ESI solvent vapor into the FAIMS analyzer region, causing signal instability and irreproducible CV values. However, by actively controlling the delivery of the gas modifier, reproducible CV spectra were obtained. The effects of adding different gas modifiers were examined using 15 positive ions having mass-to-charge (m/z) values between 90 and 734. Significant improvements in peak capacity and increases in ion transmission were readily attained by adding acetonitrile vapor, even at trace levels (≤0.1%). Increases in signal intensity were greatest for the low m/z ions; for the six lowest molecular weight species, signal intensities increased by ∼10- to over 100-fold compared with using nitrogen without gas additives, resulting in equivalent or better signal intensities compared with ESI without FAIMS. These results confirm that analytical benefits derived from the addition of gas modifiers reported with a uniform electric field (DMS) also are observed using a non-homogenous electric field (FAIMS) in the analyser region.

13.
Analyst ; 132(10): 1031-9, 2007 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-17893807

RESUMO

Pyrolysis gas chromatography-differential mobility spectrometry (py-GC-DMS) analysis of E. coli, P. aeruginosa, S. warneri and M. luteus, grown at temperatures of 23, 30, and 37 degrees C, provided data sets of ion intensity, retention time, and compensation voltage for principal component analysis. Misaligned chromatographic axes were treated using piecewise alignment, the impact on the degree of class separation (DCS) of clusters was minor. The DCS, however, was improved between 21 to 527% by analysis of variance with Fisher ratios to remove chemical components independent of growth temperature. The temperature dependent components comprised 84% of all peaks in the py-GC-DMS analysis of E. coli and were attributed to the pyrolytic decomposition of proteins rather than lipids, as anticipated. Components were also isolated in other bacteria at differing amounts: 41% for M. luteus, 14% for P. aeruginosa, and 4% for S. warneri, and differing patterns suggested characteristic dependence on temperature of growth for these bacteria. These components are anticipated to have masses from 100 to 200 Da by inference from differential mobility spectra.


Assuntos
Bactérias/química , Técnicas Bacteriológicas , Cromatografia Gasosa/instrumentação , Cromatografia Gasosa/métodos , Temperatura Alta , Análise de Componente Principal , Análise Espectral/instrumentação , Análise Espectral/métodos
14.
Analyst ; 131(11): 1216-25, 2006 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-17066190

RESUMO

Eight vegetative bacterial strains and two spores were characterized by pyrolysis-gas chromatography with differential mobility spectrometry (py-GC/DMS) yielding topographic plots of ion intensity, retention time, and compensation voltage simultaneously for ions in positive and negative polarity. Biomarkers were found in the pyrolysate at characteristic retention times and compensation voltages and were confirmed by standard addition with GC/MS analyses providing discrimination between Gram negative and Gram positive bacterial types, but no recognition of individual strains within the Gram negative bacteria. Principal component analysis was applied using two dimensional data sets of ion intensity versus retention time at five compensation voltages including the reactant ion peaks all in positive and negative ion polarity. Clustering was observed with compensation voltage (CV) chromatograms associated with ion separation in the DMS detector and little or no clustering was observed with the reactant ion peaks or CV chromatograms where ion separation is poor. Consistent clustering of Gram positive B. odysseyi and Gram negative E. coli in both positive and negative polarities with the reactant ion peak chromatograms and key CV chromatograms suggests common but unknown common chemical compositions in the pyrolysate.


Assuntos
Bactérias/isolamento & purificação , Cromatografia Gasosa/métodos , Espectrometria de Massas/métodos , Biomarcadores/análise , Microquímica/métodos , Análise de Componente Principal
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA