Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
1.
J Radiol Prot ; 39(3): 766-784, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-30865935

RESUMO

Reflecting a change in funding strategies for European research projects, and a commitment to the idea of responsible research and innovation in radiological protection (RP), a collective of research institutes and universities have developed a prospective Strategic Research Agenda (SRA) for Social Sciences and Humanities (SSH) in radiological protection. This is the first time such a research agenda has been proposed. This paper identifies six research lines of interest and concern: (1) Effects of social, psychological and economic aspects on RP behaviour; (2) Holistic approaches to the governance of radiological risks; (3) Responsible research and innovation in RP; (4) Stakeholder engagement and participatory processes in RP research, development, policy and practice; (5) Risk communication; and (6) RP cultures. These topics were developed through broad stakeholder consultation, in conjunction with activities carried out in the framework of various projects and initiatives (EU H2020 CONCERT programme, the EU FP7 projects OPERRA, PREPARE and EAGLE, the 2015-2018 RICOMET series of conferences, and the 2014 and 2016 International Symposia on Ethics of Environmental Health); as well as through dialogues with members of the European radiation protection research communities. The six research lines open opportunities to integrate a range of key social and ethical considerations into RP, thereby expanding research opportunities and programmes and fostering collaborative approaches to research and innovation.


Assuntos
Pesquisa Biomédica , Ciências Humanas , Proteção Radiológica , Projetos de Pesquisa , Ciências Sociais , Europa (Continente) , Humanos
2.
Lijec Vjesn ; 138(9-10): 250-4, 2016.
Artigo em Hr | MEDLINE | ID: mdl-30148545

RESUMO

Exothermic reaction of plaster is a very important characteristic to understand, especially when it comes to complications which can occur during local temperature change during molding plaster of Paris. And these complications directly influence the speed and quality of treatment. In this paper we measured temperatures of plaster bandage tiles 10×10 cm, from three different manufacturers in Croatian hospitals: Safix plus (Hartmann, Germany), Cellona (Lohmann &Rauscher, Austria) and Gipsan ( Ivo Lola Ribar, Croatia). We made three different plaster tiles 10×10 cm, from 10, 15 and 30 layers of plaster bandages. We immersed plaster tiles in two different water temperatures, one group in water 22 °C, and another in 34 °C. Although all plaster bandages have similar chemical characteristics, we have measured some differences. All three kinds of plaster bandages used in Croatia have low exothermic reaction when plaster molding is done in standard conditions, average local temperature is low and there is no danger of local burns. We immersed a plaster tile with 15 layers in water on 34° C, and highest average temperature was measured at Gipsan (46.2 °C), then Cellona (41.3 °C) and Safix plus (38.9 °C). On the same water immersion temperature, on plaster tile with 30 layers average temperatures were Gipsan (48.4°C), Cellona (45.4 °C), and lowest in Safix plus (41.3 °C). Plaster tiles form all manufacturers, when used 15-30 layers thick, and water immersion temperature is 34°C, develop average temperature over 40°C, in duration from 8-12 minutes. Between three different plaster bandages analyzed, Gipsan (Ivo Lola Ribar, Croatia) developed highest temperature, and some plaster tiles were measured over 50 °C.


Assuntos
Bandagens , Queimaduras , Sulfato de Cálcio/farmacologia , Temperatura Alta/efeitos adversos , Dispositivos de Fixação Ortopédica/efeitos adversos , Bandagens/efeitos adversos , Bandagens/classificação , Queimaduras/etiologia , Queimaduras/prevenção & controle , Moldes Cirúrgicos/efeitos adversos , Croácia , Análise Diferencial Térmica , Humanos , Teste de Materiais/métodos , Dispositivos de Fixação Ortopédica/normas
3.
Lijec Vjesn ; 138(1-2): 30-3, 2016.
Artigo em Hr | MEDLINE | ID: mdl-27290811

RESUMO

The purpose of this study was to compare the results of body temperature measurements obtained by standard axillary thermometers with the results of infrared tympanic and frontal skin thermometry in afebrile children. This study comprises a single-center, prospective comparison trial. A total of 345 afebrile children aged 4 to 16 years hospitalized in the pediatric surgery department for elective surgery were included. One thousand axillary, tympanic and frontal measurements were obtained and compared. We used two different infrared thermometers in this study; one type measured the tympanic temperature, the other the temperature on the forehead. The axillary temperature measured with the glass thermometer was set as the standard. Each patient was exposed to a constant environmental temperature for a minimum of 10 min before simultaneous temperature measurements. The mean-frontal temperature 36.9 ± 0.38 °C was equal to the axillary temperature 36.9 ± 0.16 °C. The mean tympanic temperature was 36.3 ± 0.98 °C. The mean difference between the tympanic and axillary temperatures was -0.4 °C. The tympanic temperature had a threefold greater dispersion than frontal and a fivefold greater dispersion than axillary temperature. The results of this study suggest that the axillary temperature measured with glass thermometer has the least dispersion. Somewhat less reliable is the frontal temperature measured with infrared thermometer. The least reliable is tympanic temperature measurement.


Assuntos
Temperatura Corporal/fisiologia , Febre/diagnóstico , Fenômenos Fisiológicos da Pele , Termografia , Termômetros , Adolescente , Axila , Criança , Pré-Escolar , Pesquisa Comparativa da Efetividade , Desenho de Equipamento , Feminino , Testa , Humanos , Masculino , Estudos Prospectivos , Reprodutibilidade dos Testes , Termografia/instrumentação , Termografia/métodos , Termografia/normas , Membrana Timpânica
4.
Lijec Vjesn ; 137(11-12): 372-6, 2015.
Artigo em Hr | MEDLINE | ID: mdl-26975068

RESUMO

The physical properties of plaster bandages are a very important factor in achieving the basic functions of immobilization (maintaining bone fragments in the best possible position), which directly affects the speed and quality of fracture healing. This paper compares the differences between the physical properties of plaster bandages (mass, specific weight, drying rate, elasticity and strength) and records the differences in plaster modeling of fast bonding 10 cm wide plaster bandages, from three different manufacturers: Safix plus (Hartmann, Germany), Cellona (Lohman Rauscher, Austria) and Gipsan (Ivo Lola Ribar ltd., Croatia). Plaster tiles from ten layers of plaster, dimension 10 x 10 cm were made. The total number of tiles from each manufacturer was 48. The water temperature of 22 °C was used for the first 24 tiles and 34 'C was used for the remainder. The average specific weight of the original packaging was: Cellona (0.52 g/cm3), Gipsan (0.50 g/cm3), Safix plus (0.38 g/cm3). Three days after plaster tile modeling an average specific weight of the tiles was: Gipsan (1.15 g/cm3), Safix plus (1.00 g/cm3), Cellona (1.10 g/cm3). The average humidity of 50% for Safix plus and Cellona plaster tiles was recorded 18 hours after modeling, while for the Gipsan plaster tiles, this humidity value was seen after 48 hours. On the third day after plaster modeling the average humidity of the plaster tiles was 30% for Gipsan, 24% for Safix and 16% for Cellona. Cellona plaster tiles made with 34 °C water achieved the highest elasticity (11.75±3.18 MPa), and Gipsan plaster tiles made with 22 °C had the lowest (7.21±0.9 MPa). Cellona plaster tiles made with 34 °C water showed maximum material strength (4390±838 MPa), and Gipsan plaster tiles made with 22 °C water showed the lowest material strength (771±367 MPa). The rigidity and strength of Cellona and Gipsan plaster are higher in tiles made in warmer water, and for Safix plus are higher in tiles made in cooler water. All three types of plaster differentiate in physical properties. The differences in mass and specific weight before and after plaster modeling are minimal. There are greater differences in drying rate, elasticity and strength between the three different plaster materials.


Assuntos
Bandagens , Sulfato de Cálcio/uso terapêutico , Bandagens/classificação , Sulfato de Cálcio/química , Croácia , Dessecação , Alemanha , Fenômenos Mecânicos
5.
J Hazard Mater ; 441: 129880, 2023 01 05.
Artigo em Inglês | MEDLINE | ID: mdl-36067557

RESUMO

Coal ash deposited in open landfills is a potential source of environmental pollutants due to the contained toxic element content. The weathered coal ash used in this study additionally contains enhanced activity concentrations of 238U series radionuclides. This study aimed to determine the physiological effects of enhanced ionizing radiation and toxic elements on five plant species (smilo grass, sticky fleabane, blackberry, mastic and pine tree) inhabiting the coal ash disposal site. Among the potentially toxic measured elements, contents of Sb, As and especially V significantly exceeded their respective levels at the control site, as well as the content of 238U and its progenies. Significant changes in photosynthetic pigments were recorded following chronic exposure to the plants growing on the coal ash site. Different responses were also observed in the plant species regarding the activity of catalase and glutathione-S-transferase (GST). The level of lipid peroxidation markedly increased in plants from the disposal site, except in blackberry, wherein GST activity was the strongest, indicating an important role of that enzyme in the adaptation to coal ash pollutants. The results of this study suggest that the modulation of the studied biochemical parameters in plants growing on coal ash is primarily species-dependent.


Assuntos
Poluentes Radioativos do Ar , Urânio , Poluentes Radioativos do Ar/análise , Catalase , Carvão Mineral/análise , Cinza de Carvão/análise , Cinza de Carvão/toxicidade , Glutationa , Plantas , Centrais Elétricas , Radioisótopos/análise , Transferases , Urânio/toxicidade
6.
Arh Hig Rada Toksikol ; 73(2): 94-106, 2022 Jul 07.
Artigo em Inglês | MEDLINE | ID: mdl-35792772

RESUMO

An enormous increase in the application of wireless communication in recent decades has intensified research into consequent increase in human exposure to electromagnetic (EM) radiofrequency (RF) radiation fields and potential health effects, especially in school children and teenagers, and this paper gives a snap overview of current findings and recommendations of international expert bodies, with the emphasis on exposure from Wi-Fi technology indoor devices. Our analysis includes over 100 in vitro, animal, epidemiological, and exposure assessment studies (of which 37 in vivo and 30 covering Wi-Fi technologies). Only a small portion of published research papers refers to the "real" health impact of Wi-Fi technologies on children, because they are simply not available. Results from animal studies are rarely fully transferable to humans. As highly controlled laboratory exposure experiments do not reflect real physical interaction between RF radiation fields with biological tissue, dosimetry methods, protocols, and instrumentation need constant improvement. Several studies repeatedly confirmed thermal effect of RF field interaction with human tissue, but non-thermal effects remain dubious and unconfirmed.


Assuntos
Ondas de Rádio , Tecnologia , Adolescente , Animais , Criança , Humanos , Ondas de Rádio/efeitos adversos
7.
Radiat Prot Dosimetry ; 188(3): 361-371, 2020 Jun 24.
Artigo em Inglês | MEDLINE | ID: mdl-31885046

RESUMO

Radiation protection and radiation dosimetry strongly rely on measurements performed by dosimetry instrumentation. Two categories of dosimetry instrumentation prevail: personal dosemeters and survey meters. Passive dosemeters were for many years the base of personal and area dosimetry (environmental, including workplace). Survey meters have been long-established between area meters due to their dose rate measurement capability, but just over a decade ago, debates over possibility that electronic personal dosemeters (EPDs) could replace passive personal dosemeters as legal monitoring devices have started. These debates have now branched into the use of EPDs, but also survey meters in various exposure scenarios, where some concerns have been reported. These concerns were mostly related to the response in pulsed X-ray fields and poor energy response. This article summarizes recent literature related to electronic dosemeters for strongly penetrating photon radiation and covers technologies used in contemporary EPDs and survey meters, their performance and future perspectives.


Assuntos
Exposição Ocupacional , Monitoramento de Radiação , Proteção Radiológica , Exposição Ocupacional/análise , Doses de Radiação , Radiação Ionizante , Tecnologia
8.
Coll Antropol ; 32 Suppl 2: 181-4, 2008 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19138023

RESUMO

Diagnostic radiology's basic task is to provide high quality diagnostic image information about anatomic detail or ongoing physiological process within patient's body, where such information can not be provided using alternative diagnostic method which excludes the use of ionizing radiation. Ensuring adequate clinical diagnostic information together with the least possible exposure of the patient to radiation (As Low As Reasonably Achievable--ALARA principle) at the lowest costs is quality assurance (QA) program's main goal--optimization of radiological practice. Implementation of QA program does not mean just meeting legal requirements regarding quality control (QC) of X-ray and associated equipment and areas where they are installed but also implies optimum use of equipment, human and material resources inspected trough film rejection analysis and monitoring of patient doses received in particular radiological diagnostic examinations. In Republic of Croatia QA program in diagnostic radiology has not been yet systematically implemented in any medical institution. Except for legally bounded QC of X-ray equipment, other aspects of QA program are not conducted due to many reasons such as lack of educated staff and adequate measuring equipment, absence of obligatory legal acts, poor financial situation in Croatian health care system and many others. Implementation of QA program in diagnostic radiology departments of Croatian medical institutions is an imperative in order to harmonize the good practice with other countries in EU.


Assuntos
Garantia da Qualidade dos Cuidados de Saúde/organização & administração , Radiografia/normas , Saúde Radiológica/normas , Croácia , Implementação de Plano de Saúde , Humanos
9.
Arh Hig Rada Toksikol ; 68(4): 298-307, 2017 Dec 20.
Artigo em Inglês | MEDLINE | ID: mdl-29337685

RESUMO

The ERICA project (Environmental Risk from Ionising Contaminants: Assessment and Management) was co-funded by the European Union as part of the 6th Framework Programme (FP EURATOM). The project was carried out between 2004 and 2007 as the collective work of 15 organisations in seven European countries. Two significant outputs of the project are the ERICA Integrated Approach and the ERICA Tool. The ERICA Integrated Approach consists of three elements: assessment, risk characterisation and management. The ERICA Tool is a practical implementation of the assessment component of the ERICA Integrated Approach and has a three-tier structure. The aim of this review paper is to give a concise overview of ERICA project outputs and their structure, updates done since their first release in 2007, as well as to provide a context for their practical application in environmental radiation protection and radiological risk assessments for various engineering scenarios.


Assuntos
Exposição Ambiental/análise , Monitoramento de Radiação/métodos , Radiação Ionizante , Europa (Continente) , Humanos , Medição de Risco
10.
Acta Clin Croat ; 56(4): 600-608, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29590712

RESUMO

Plaster splints are used daily in surgical and orthopedic fields in order to immobilize injured children and adults. The aim of this study was to measure the aerodynamic diameter and concentration of dust particles in the air caused by sawing plaster splints (calcium sulfate dehy-drate). We performed fractional measurements of airborne dust particles. The measured particles, which can potentially be inhaled, may have a specific negative effect on human health. Measurements were conducted in laboratory research facilities that simulated hospital conditions within a casting room and the associated waiting room. Measurements within the casting room were made using two particle collector devices and one laser photometer. The measurement for the simulated waiting room was performed using the same principles and devices. The collected plaster dust particles differed in aerodynamic diameter and concentration according to the various locations observed. The highest concentration of particles of all sizes was recorded at the site of cast sawing. There was direct correlation between distance from the source and concentration of airborne particles; this concentration was lowest in the waiting room. The concentrations of plaster dust recorded were lower than the recommended minimal limit values for total and respiratory fractions in Croatia. Accordingly, it can be assumed that sawing of plaster splints has no harmful health effects on the exposed patients and health personnel.


Assuntos
Moldes Cirúrgicos , Poeira , Adulto , Criança , Croácia , Humanos , Tamanho da Partícula
11.
Injury ; 46 Suppl 6: S103-6, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26596415

RESUMO

INTRODUCTION: The bone healing process is very complex. In simple terms, bone healing comprises three basic steps, the inflammation phase, the repair phase and the remodelling phase. The increase in blood flow around the fracture during the healing process increases the temperature of the surrounding tissue. Infrared thermography is a method of measuring body temperature that can detect temperature changes during bone healing. Studies on the application of thermography in traumatology are scarce, and there are no studies of thermal changes during normal bone healing. The authors have tried to determine the dynamics of thermal changes during bone healing. MATERIAL AND METHODS: The Flir ThermaCam B2 (FLIR Systems, Inc., Oregon, USA) was used for all measurements. Thermographic recordings were made one, three, five, 11 and 23 weeks after fracture. The contralateral, healthy, forearm was used for comparison. RESULTS: A total of 25 patients of mean age 65.9±10.4 years (range 50-80 years) with fracture of the distal radius were examined in this study. The mean temperature difference between healthy and fractured distal forearm one week after fracture was 1.20±0.48°C, three weeks after fracture was 1.42±0.54°C, five weeks after fracture was 1.04±0.53°C, 11 weeks after fracture was 0.50±0.30°C, and 23 weeks after fracture was 0.22±0.25°C. CONCLUSION: Preliminary findings during this research showed significant temperature changes during healing of distal radius fractures. Infrared thermography is a simple and reliable method in clinical practice that could be used as a good follow-up method in traumatology, but further investigations on more patients are needed.


Assuntos
Fixação Interna de Fraturas , Consolidação da Fratura , Inflamação/fisiopatologia , Fraturas do Rádio/fisiopatologia , Termografia , Articulação do Punho/fisiopatologia , Idoso , Feminino , Humanos , Inflamação/metabolismo , Masculino , Pessoa de Meia-Idade , Fraturas do Rádio/metabolismo , Amplitude de Movimento Articular , Termografia/métodos , Resultado do Tratamento
12.
J Hazard Mater ; 261: 584-92, 2013 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-23994657

RESUMO

Phosphogypsum (PG), a waste product in phosphate fertilizer production, is characterized by technically enhanced natural radioactivity. The presented investigation was performed on a PG deposition site in Croatia. A new approach in the determination of the spread of PG particles from the deposition site into the environment based on the PG particle radioactivity measurements is suggested and explained. The stationary diffusion model was assumed and employed to describe long term PG particle transfer into the surroundings. The advantage of this method is that it requires a minimal number of measurement locations and offers a realistic and reliable distribution of PG particles. The mass concentration of PG particles decreased to the distance of about 3m, at most up to 10 m from the deposition site edge. The results indicate that a unique mechanism of particle transport exists and the migration of PG particles by surface water is the dominant way of their spread. The particle current deduced from the measurements was very low, approximately 4.05 × 10(-2)kg/h, and the migration coefficient was approximately 1.69 × 10(-5)m(2)/h. The obtained results confirmed the initial hypothesis of the stationarity of the migration process, reached within about 6 years.


Assuntos
Sulfato de Cálcio , Modelos Teóricos , Fósforo , Poluentes do Solo , Difusão , Fertilizantes , Locais de Resíduos Perigosos , Resíduos Industriais , Movimentos da Água , Vento
13.
Arh Hig Rada Toksikol ; 60(1): 53-60, 2009 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-19329376

RESUMO

Radiation dosimetry in protection against ionising radiation involves research of all possible pathways through which natural or man-made radioactive materials can contaminate a habitat and actually harm its biota. It also takes into account natural and artificial (man-made) electromagnetic ionizing radiation (gamma and x radiation). This article presents a dosimetric study assessing exposure to man-made ionising radiation of local environment and total occupational exposure of two professional workers involved in characterisation, conditioning, and securing of unused radioactive sealed sources. The purpose of the study was to validate a new active electronic dosimeter (AED) of type ALARA OD and to develop a new monitoring method by tracing the external occupational exposure over real time. This method is used to continuously measure and record external radiation doses and, which is a novelty, establish dose rates receiving pattern as a function of real time. Occupational whole body dosimetric results obtained with AED were compared with results obtained with passive dosimetry (film badge and thermoluminiscence). Air, dust, and silicon sand samples were analysed by gamma-spectrometry to estimate internal exposure of the two workers to 222Rn due to inhalation or ingestion of dust and sand in indoor air. In order to establish total occupational exposure, control radon measurement was performed in the immediate environment and the external Hazard index (Hex) was calculated.


Assuntos
Exposição Ocupacional , Doses de Radiação , Monitoramento de Radiação , Radiometria/instrumentação , Poluentes Radioativos do Ar/análise , Radiação de Fundo , Humanos , Proteção Radiológica , Radônio/análise
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA