Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 30
Filtrar
1.
Opt Express ; 31(4): 5414-5425, 2023 Feb 13.
Artigo em Inglês | MEDLINE | ID: mdl-36823822

RESUMO

We report a directly modulated distributed feedback laser operating in gain-switching mode for preparing the coherent states required for the Gaussian-modulated coherent-state (GMCS) continuous-variable quantum key distribution (CV-QKD) protocol. The proposed single-component quantum transmitter design eliminates the need for external modulators, decreasing the complexity of GMCS CV-QKD systems. The experimental results demonstrate a potential asymptotic secret key rate value of 2.63 Mbps over an 11-km fiber link, making the directly modulated GMCS transmitter particularly suitable for metropolitan optical networks where compactness, robustness, and low cost are key desirable features.

2.
Opt Express ; 29(10): 14815-14827, 2021 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-33985195

RESUMO

We present a versatile transmitter capable of performing both discrete variable and continuous variable quantum key distribution protocols (DV-QKD and CV-QKD, respectively). Using this transmitter, we implement a time-bin encoded BB84 DV-QKD protocol over a physical quantum channel of 47 km and a GG02 CV-QKD protocol with true local oscillator over a 10.5 km channel, achieving secret key rates of 4.1 kbps and 1 Mbps for DV- and CV-QKD, respectively. The reported transmitter scheme is particularly suitable for re-configurable optical networks where the QKD protocol is selected to optimize the performance according to the parameters of the links.

3.
Nature ; 526(7575): 682-6, 2015 Oct 29.
Artigo em Inglês | MEDLINE | ID: mdl-26503041

RESUMO

More than 50 years ago, John Bell proved that no theory of nature that obeys locality and realism can reproduce all the predictions of quantum theory: in any local-realist theory, the correlations between outcomes of measurements on distant particles satisfy an inequality that can be violated if the particles are entangled. Numerous Bell inequality tests have been reported; however, all experiments reported so far required additional assumptions to obtain a contradiction with local realism, resulting in 'loopholes'. Here we report a Bell experiment that is free of any such additional assumption and thus directly tests the principles underlying Bell's inequality. We use an event-ready scheme that enables the generation of robust entanglement between distant electron spins (estimated state fidelity of 0.92 ± 0.03). Efficient spin read-out avoids the fair-sampling assumption (detection loophole), while the use of fast random-basis selection and spin read-out combined with a spatial separation of 1.3 kilometres ensure the required locality conditions. We performed 245 trials that tested the CHSH-Bell inequality S ≤ 2 and found S = 2.42 ± 0.20 (where S quantifies the correlation between measurement outcomes). A null-hypothesis test yields a probability of at most P = 0.039 that a local-realist model for space-like separated sites could produce data with a violation at least as large as we observe, even when allowing for memory in the devices. Our data hence imply statistically significant rejection of the local-realist null hypothesis. This conclusion may be further consolidated in future experiments; for instance, reaching a value of P = 0.001 would require approximately 700 trials for an observed S = 2.4. With improvements, our experiment could be used for testing less-conventional theories, and for implementing device-independent quantum-secure communication and randomness certification.

4.
Opt Express ; 28(10): 14547-14559, 2020 May 11.
Artigo em Inglês | MEDLINE | ID: mdl-32403493

RESUMO

We report a plug-and-play continuous variable quantum key distribution system (CV-QKD) with Gaussian modulated quadratures and a true local oscillator. The proposed configuration avoids the need for frequency locking two narrow line-width lasers. To minimize Rayleigh back-scattering, we utilize two independent fiber strands for the distribution of the laser and the transmission of the quantum signals. We further demonstrate the quantum-classical co-existing capability of our system by injecting high-power classical light in both fibers. A secret key rate up to 0.88 Mb/s is obtained by using two fiber links of 13 km and up to 0.3 Mb/s when adding 4 mW of classical light in the optical fiber used for transmitting the quantum signal. The reported performance indicates that the proposed QKD scheme has the potential to become an effective low-cost solution for metropolitan optical networks.

5.
Opt Lett ; 40(17): 3962-5, 2015 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-26368687

RESUMO

We present a proof-of-concept experiment aimed at increasing the sensitivity of Fiber-Bragg-gratings temperature sensors by making use of a weak-value-amplification scheme. The technique requires only linear optics elements for its implementation and appears as a promising method for increasing the sensitivity than state-of the-art sensors can currently provide. The device implemented here is able to generate a shift of the centroid of the spectrum of a pulse of ∼0.035 nm/°C, a nearly fourfold increase in sensitivity over the same fiber-Bragg-grating system interrogated using standard methods.

6.
Analyst ; 140(22): 7734-41, 2015 Nov 21.
Artigo em Inglês | MEDLINE | ID: mdl-26455518

RESUMO

We introduce a new image cytometer design for the detection of very small particulates and demonstrate its capability in water analysis. The device is a compact microscope composed of off-the-shelf components, such as a light emitting diode (LED) source, a complementary metal-oxide-semiconductor (CMOS) image sensor, and a specific combination of optical lenses that allow, through an appropriate software, Fourier transform processing of the sample volume. Waterborne microorganisms, such as Escherichia coli (E. coli), Legionella pneumophila (L. pneumophila) and phytoplankton, are detected by interrogating the volume sample either in a fluorescent or label-free mode, i.e. with or without fluorescein isothiocyanate (FITC) molecules attached to the micro-organisms, respectively. We achieve a sensitivity of 50 cells per ml, which can be further increased to 0.2 cells per ml by pre-concentrating an initial sample volume of 500 ml with an ad hoc fluidic system. We also prove the capability of the proposed image cytometer of differentiating microbiological populations by size with a resolution of 3 µm and operating in real contaminated water.


Assuntos
Escherichia coli/isolamento & purificação , Citometria por Imagem/instrumentação , Legionella pneumophila/isolamento & purificação , Microbiologia da Água , Desenho de Equipamento , Fluoresceína-5-Isotiocianato/análise , Corantes Fluorescentes/análise , Citometria por Imagem/economia , Microscopia/instrumentação , Semicondutores
7.
Opt Express ; 22(2): 1645-54, 2014 Jan 27.
Artigo em Inglês | MEDLINE | ID: mdl-24515170

RESUMO

We demonstrate a high bit-rate quantum random number generator by interferometric detection of phase diffusion in a gain-switched DFB laser diode. Gain switching at few-GHz frequencies produces a train of bright pulses with nearly equal amplitudes and random phases. An unbalanced Mach-Zehnder interferometer is used to interfere subsequent pulses and thereby generate strong random-amplitude pulses, which are detected and digitized to produce a high-rate random bit string. Using established models of semiconductor laser field dynamics, we predict a regime of high visibility interference and nearly complete vacuum-fluctuation-induced phase diffusion between pulses. These are confirmed by measurement of pulse power statistics at the output of the interferometer. Using a 5.825 GHz excitation rate and 14-bit digitization, we observe 43 Gbps quantum randomness generation.

8.
Opt Express ; 20(11): 12247-60, 2012 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-22714214

RESUMO

Optical beam steering is a key element in many industrial and scientific applications like in material processing, information technologies, medical imaging and laser display. Even though galvanometer-based scanners offer flexibility, speed and accuracy at a relatively low cost, they still lack the necessary control over the polarization required for certain applications. We report on the development of a polarization steerable system assembled with a fiber polarization controller and a galvanometric scanner, both controlled by a digital signal processor board. The system implements control of the polarization decoupled from the pointing direction through a feed-forward control scheme. This enables to direct optical beams to a desired direction without affecting its initial polarization state. When considering the full working field of view, we are able to compensate polarization angle errors larger than 0.2 rad, in a temporal window of less than ∼ 20 ms. Given the unification of components to fully control any polarization state while steering an optical beam, the proposed system is potentially integrable and robust.


Assuntos
Eletrônica , Lasers , Refratometria/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Retroalimentação
9.
Opt Express ; 20(7): 7112-8, 2012 Mar 26.
Artigo em Inglês | MEDLINE | ID: mdl-22453393

RESUMO

All-optical-fiber Fabry-Perot interferometers (FPIs) with microcavities of different shapes were investigated. It was found that the size and shape of the cavity plays an important role on the performance of these interferometers. To corroborate the analysis, FPIs with spheroidal cavities were fabricated by splicing a photonic crystal fiber (PCF) with large voids and a conventional single mode fiber (SMF), using an ad hoc splicing program. It was found that the strain sensitivity of FPIs with spheroidal cavities can be controlled through the dimensions of the spheroid. For example, a FPI whose cavity had a size of ~10x60 µm exhibited strain sensitivity of ~10.3 pm/µÎµ and fringe contrast of ~38 dB. Such strain sensitivity is ~10 times larger than that of the popular fiber Bragg gratings (~1.2 pm/µÎµ) and higher than that of most low-finesse FPIs. The thermal sensitivity of our FPIs is extremely low (~1pm/°C) due to the air cavities. Thus, a number of temperature-independent ultra-sensitive microscopic sensors can be devised with the interferometers here proposed since many parameters can be converted to strain. To this end, simple vibration sensors are demonstrated.


Assuntos
Tecnologia de Fibra Óptica/instrumentação , Interferometria/instrumentação , Refratometria/instrumentação , Transdutores , Desenho de Equipamento , Análise de Falha de Equipamento , Miniaturização
10.
Nanotechnology ; 23(39): 395603, 2012 Oct 05.
Artigo em Inglês | MEDLINE | ID: mdl-22972183

RESUMO

We show that graphene can be used as a protective layer for transparent electrodes made of materials which would otherwise deteriorate when exposed to the environment. In particular, we investigate aluminum-doped zinc oxides and ultrathin copper films capped with a one-atom graphene layer in damp heat (95% relative humidity and 95 °C) and high temperature (up to 180 °C) conditions. The results clearly indicate that a graphene layer can strongly reduce degradation of the electrodes' electrical, optical properties and surface morphology, thus preserving the functionality of the transparent electrodes. The proposed technique is particularly suitable for flexible optoelectronic devices thanks to the mechanical strength of graphene when subjected to bending.

11.
Opt Express ; 19(21): 20665-72, 2011 Oct 10.
Artigo em Inglês | MEDLINE | ID: mdl-21997077

RESUMO

Random numbers are essential for applications ranging from secure communications to numerical simulation and quantitative finance. Algorithms can rapidly produce pseudo-random outcomes, series of numbers that mimic most properties of true random numbers while quantum random number generators (QRNGs) exploit intrinsic quantum randomness to produce true random numbers. Single-photon QRNGs are conceptually simple but produce few random bits per detection. In contrast, vacuum fluctuations are a vast resource for QRNGs: they are broad-band and thus can encode many random bits per second. Direct recording of vacuum fluctuations is possible, but requires shot-noise-limited detectors, at the cost of bandwidth. We demonstrate efficient conversion of vacuum fluctuations to true random bits using optical amplification of vacuum and interferometry. Using commercially-available optical components we demonstrate a QRNG at a bit rate of 1.11 Gbps. The proposed scheme has the potential to be extended to 10 Gbps and even up to 100 Gbps by taking advantage of high speed modulation sources and detectors for optical fiber telecommunication devices.

12.
Opt Express ; 19(5): 3825-34, 2011 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-21369207

RESUMO

A novel integrated optical source capable of emitting faint pulses with different polarization states and with different intensity levels at 100 MHz has been developed. The source relies on a single laser diode followed by four semiconductor optical amplifiers and thin film polarizers, connected through a fiber network. The use of a single laser ensures high level of indistinguishability in time and spectrum of the pulses for the four different polarizations and three different levels of intensity. The applicability of the source is demonstrated in the lab through a free space quantum key distribution experiment which makes use of the decoy state BB84 protocol. We achieved a lower bound secure key rate of the order of 3.64 Mbps and a quantum bit error ratio as low as 1.14×10⁻² while the lower bound secure key rate became 187 bps for an equivalent attenuation of 35 dB. To our knowledge, this is the fastest polarization encoded QKD system which has been reported so far. The performance, reduced size, low power consumption and the fact that the components used can be space qualified make the source particularly suitable for secure satellite communication.


Assuntos
Amplificadores Eletrônicos , Tecnologia de Fibra Óptica/instrumentação , Lasers de Estado Sólido , Iluminação/instrumentação , Refratometria/instrumentação , Medidas de Segurança , Desenho Assistido por Computador , Desenho de Equipamento , Análise de Falha de Equipamento
13.
Opt Express ; 18(26): 27181-90, 2010 Dec 20.
Artigo em Inglês | MEDLINE | ID: mdl-21196995

RESUMO

We report on an integrated acousto-optic filter in domain inverted LiNbO3 using a coplanar electrode configuration, which can achieve complete optical switching at electrical powers as low as 50 mW. These values are more than one order of magnitude lower than previously reported results [Opt. Lett. 34, 3205 (2009)]. In order to design the low power consumption devices, we have calculated surface acoustic wave excitation, propagation and acousto-optic interaction in the domain inverted LiNbO3 superlattice using scalar approximation and FEM analysis. Results from both modeling techniques are in good agreement with the experiments, including direct measurement of the acoustic displacement using laser interferometry and acousto-optic performance.


Assuntos
Acústica/instrumentação , Nióbio/química , Dispositivos Ópticos , Óxidos/química , Transdutores , Desenho Assistido por Computador , Fontes de Energia Elétrica , Desenho de Equipamento , Análise de Falha de Equipamento , Integração de Sistemas
14.
Opt Lett ; 34(20): 3205-7, 2009 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-19838274

RESUMO

We report an integrated acousto-optic polarization converter exploiting a novel surface acoustic superlattice (S-ASL) transducer. The S-ASL transducer is made of a ZX-cut periodically poled lithium niobate (PPLN) crystal with uniform coplanar electrodes for surface acoustic wave (SAW) generation. For a PPLN period of 20 microm the SAW is excited at an rf of about 190 MHz, while the phase matching occurs at an optical wavelength of around 1456 nm. The measured mode conversion efficiency of 90% at an input rf power of 1 W and the 3 dB optical bandwidth of 2.5 nm confirm the confinement of the SAW between the electrode gap and the constructive interaction along the whole 10 mm electrode length.


Assuntos
Acústica , Óptica e Fotônica/métodos , Amplificadores Eletrônicos , Eletrodos , Desenho de Equipamento , Equipamentos e Provisões , Tecnologia de Fibra Óptica , Humanos , Nióbio/química , Dispositivos Ópticos , Óxidos/química , Propriedades de Superfície , Transdutores
15.
Nanotechnology ; 20(27): 275204, 2009 Jul 08.
Artigo em Inglês | MEDLINE | ID: mdl-19528671

RESUMO

We report on the possibility of using a thin Ni layer, instead of ITO, as a semitransparent hole-injecting electrode for bottom polymer LEDs. Thin metal layers of Ni were deposited by a sputtering technique and their electrical and optical properties with different deposition times have been investigated. Both square resistance and transmittance were seen to decrease with deposition time (thickness). The films showed a transmittance of around 30-40%, which is quite low compared to the 86% of ITO, while their square resistance was higher than that of ITO. Nevertheless, diodes based on a blue emitting polymer, polyfluorene (PFO), showed the same efficiency for either ITO or thin Ni electrodes, although the Ni transmittance is around 2.5 times lower than the ITO transmittance. Such preliminary results definitively suggest that indium-free organic devices can be achieved.

16.
Opt Express ; 15(17): 10739-43, 2007 Aug 20.
Artigo em Inglês | MEDLINE | ID: mdl-19547429

RESUMO

Domain inversion is used in a simple fashion to improve significantly the performance of a waveguide electro-optic modulator in z-cut LiNbO(3). The waveguide arms of the Mach-Zehnder interferometer are placed in opposite domain-oriented regions under the same, narrower and more efficient electrode, so that opposite phase shifts (push-pull effect) can still be achieved despite the arms being subjected to the same electric field. Switching voltages close to 2 V are obtained, which allow 10Gb/s modulation with inexpensive drivers, such as those used for electro-absorption modulators, which deliver driving voltages well below 3V.

17.
Biomed Opt Express ; 8(2): 1240-1249, 2017 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-28271014

RESUMO

We introduce an image cytometer (I-CYT) for the analysis of phytoplankton in fresh and marine water environments. A linear quantification of cell numbers was observed covering several orders of magnitude using cultures of Tetraselmis and Nannochloropsis measured by autofluorescence in a laboratory environment. We assessed the functionality of the system outside the laboratory by phytoplankton quantification of samples taken from a marine water environment (Dutch Wadden Sea, The Netherlands) and a fresh water environment (Lake Ijssel, The Netherlands). The I-CYT was also employed to study the effects of two ballast water treatment systems (BWTS), based on chlorine electrolysis and UV sterilization, with the analysis including the vitality of the phytoplankton. For comparative study and benchmarking of the I-CYT, a standard flow cytometer was used. Our results prove a limit of detection (LOD) of 10 cells/ml with an accuracy between 0.7 and 0.5 log, and a correlation of 88.29% in quantification and 96.21% in vitality, with respect to the flow cytometry results.

18.
ACS Appl Mater Interfaces ; 7(10): 5938-43, 2015 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-25710848

RESUMO

A graphene (Gr) on a polyimide (PI) polymer film (Gr-PI film), obtained by a direct peel-off technique, is proposed and investigated. Thanks to its high transparency, electrical conductivity, mechanical strength, and chemical durability, the Gr-PI film is an ideal substrate for flexible electronic and optoelectronic devices, including transistors, light-emitting diodes, and plasmonic antennas. It is obtained using a straightforward method. After spin coating and curing a PI film on Gr previously grown on Cu, one can separate the Gr-PI film from the Cu foil thanks to the difference in the adhesive energy between the Gr-Cu and Gr-PI interfaces. The resulting Gr-PI film shows an average electrical sheet resistance ranging from 520 to 860 Ω/sq and a very high optical transmission (>90%), which have allowed the demonstration of a transparent heater. The surface morphology of the Gr-PI film follows that of the Cu foil, with the latter maintaining its surface properties and allowing in this way its reuse in subsequent chemical vapor deposition growth. The method can also be applied to patterned Gr, as is demonstrated for nanosize ribbons with a width of a few tens of nanometers.

19.
Opt Lett ; 34(3): 325-7, 2009 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-19183646

RESUMO

Transparent electrodes made of single-component ultrathin (<10 nm) metal films (UTMFs) are obtained by sputtering deposition. We show that the optical transparency of the deposited films (chromium and nickel) is comparable to that of indium tin oxide (ITO) in the visible and near-infrared range (0.4-2.5 microm), while it can be significantly higher in the ultraviolet (175-400 nm) and mid-infrared (2.5-25 microm) regions. Despite their very small thickness, the deposited UTMFs are also uniform and continuous over the 10 cm substrate, as it is confirmed by the measured low electrical resistivity. The excellent optical and electrical properties, stability, compatibility with active materials, process simplicity, and potential low cost make UTMFs high-quality transparent electrodes for the optoelectronics industry, seriously competing with widely used transparent conductive oxides, such as ITO.

20.
Opt Lett ; 25(23): 1720-2, 2000 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-18066325

RESUMO

Optical parametric interaction in isotropic third-order nonlinear media with magneto-optic properties is investigated. It is shown that new phase-matching conditions with a magneto-optic contribution are possible. In particular, we study four-wave mixing and electric field-induced three-wave parametric processes in the presence of a magnetic field applied along the direction of propagation of the interacting waves. Control of the new phase-matching branches can be achieved by tuning of the magnetic field.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA