Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 46
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
Int Ophthalmol ; 42(3): 747-756, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34622374

RESUMO

KEY MESSAGES: Visual acuity is the most used method to assess visual function in children. Contrast sensitivity complements the information provided for visual acuity, but it is not commonly used in clinical practice. Digital devices are increasingly used as a method to evaluate visual function, due to multiple advantages. Testing with these devices can improve the evaluation of visual development in children from a few months of age. Visual acuity and contrast sensitivity tests, using eye tracking technology, are able to measure visual function in children across a wide range of ages, objectively, quickly and without need of an experienced examiner. PURPOSE: To report age-normative values for grating visual acuity and contrast sensitivity in healthy children using a digital device with eye tracking technology and to validate the grating acuity test. METHODS: In the first project of the study, we examined healthy children aged between 6 months and 7 years with normal ophthalmological assessment. Grating visual acuity (VA) and contrast sensitivity (CS) were assessed using a preferential gaze paradigm with a DIVE (Device for an Integral Visual Examination) assisted with eye tracking technology to provide age norms. For the validation project, we compared LEA grating test (LGT) with DIVE VA in a group of children aged between 6 months and 4 years with normal and abnormal visual development. RESULTS: Fifty-seven children (2.86 ± 1.55 years) were examined with DIVE VA test and 44 successfully completed DIVE CS test (3.06 ± 1.41 years). Both, VA and CS values increased with age, mainly along the first two years of life. Sixty-nine patients (1.34 ± 0.61 years) were included in the DIVE VA test validation. The mean difference between LGT and DIVE VA was - 1.05 ± 4.54 cpd with 95% limits of agreement (LoA) of - 9.95-7.84 cpd. Agreement between the two tests was higher in children younger than 1 year with a mean difference of - 0.19 ± 4.02 cpd. CONCLUSIONS: DIVE is an automatic, objective and reliable tool to assess several visual function parameters in children, and it has good agreement with classical VA tests, especially for the first stage of life.


Assuntos
Sensibilidades de Contraste , Oftalmologia , Criança , Tecnologia de Rastreamento Ocular , Humanos , Lactente , Testes Visuais/métodos , Acuidade Visual
2.
Ultrasound Obstet Gynecol ; 43(1): 41-7, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23836499

RESUMO

OBJECTIVE: To assess the effects of late small-for-gestational-age (SGA) birth and late prematurity on cognitive outcomes and structural changes in the central nervous system at primary school age, using a novel approach to examine changes in neuronal integrity of the retina. METHODS: We conducted a cross-sectional study of 347 children aged 6-13 years, including in the analysis only infants born after 34 weeks' gestation. We recorded all perinatal outcomes through a survey of parents. Neuronal damage was evaluated using optical coherence tomography of the retina. In a subgroup of 112 children aged 6-8 years, visuospatial perception was evaluated with the Children's Bender Visual Motor Gestalt Test. RESULTS: The proportions of SGA and late preterm children were 11.8 and 6.3%, respectively. Prematurity and SGA were simultaneously present in five children. When compared with controls, SGA children showed significantly lower than average retinal nerve fiber layer (RNFL) thickness (94.1 vs 98.8 µm; P = 0.007) and an increased percentage of abnormal Bender scores (27.3 vs 6.2%; P = 0.017) (odds ratio 5.6 (95% CI, 1.2-26.8)). These differences increased when late SGA infants with a birth weight below the 3(rd) percentile were compared with SGA infants with a birth weight between the 3(rd) and 10(th) percentiles and with controls, for RNFL thickness (92.5 vs 94.6 and 98.8 µm, respectively; P = 0.021) and abnormal Bender tests (33.3 vs 25.0 and 6.2%, respectively; P = 0.036). However, no differences were found in retinal structure and visuomotor performance between late preterm and term infants. CONCLUSIONS: These data suggest that late SGA and late prematurity induce a distinct neuronal pattern of structural changes that persist at school age. Late-onset SGA infants are at increased risk for axonal loss in the retina and present specific visuomotor difficulties.


Assuntos
Desenvolvimento Infantil , Transtornos Cognitivos/fisiopatologia , Recém-Nascido Prematuro , Recém-Nascido Pequeno para a Idade Gestacional , Nervo Óptico/fisiopatologia , Retina/fisiopatologia , Tomografia de Coerência Óptica , Adolescente , Criança , Transtornos Cognitivos/diagnóstico , Estudos Transversais , Feminino , Humanos , Masculino , Razão de Chances , Inquéritos e Questionários , Testes Visuais
3.
Ultrasound Obstet Gynecol ; 40(3): 297-303, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22740299

RESUMO

OBJECTIVE: To assess cognitive outcomes and structural changes in the central nervous system, the latter using a novel approach to examine changes in neuronal integrity of the optic nerve, in children at 5-6½ years of age who were born small-for-gestational age (SGA) at term having shown normal umbilical artery (UA) Doppler. METHODS: We compared neuronal damage, cognitive deficits and visuospatial perception in two cohorts of infants, one born SGA (n = 40) and one born appropriate-for-gestational age (AGA) (n = 39) in weight. Neuronal damage was evaluated using optical coherence tomography (OCT) of the optic nerve. Cognitive deficits were assessed with the Wechsler Preschool and Primary Scale of Intelligence (WPPSI) test. Visuospatial perception was evaluated with Rey-Osterreich Complex Figure (ROCF) tasks. RESULTS: Children from the SGA group had a significantly thinner average retinal nerve fiber layer (RNFL) compared with those from the AGA group (98.2 vs 104.5 µm, P = 0.012). Children from the SGA group exhibited impaired performance in copy tasks on the ROCF (3.27 vs 3.56, P = 0.036) and a higher rate of suboptimal WPPSI test performance intelligence quotient scores (15% vs 0%; P = 0.025) compared with those from the AGA group. CONCLUSION: Term infants with normal UA Doppler born SGA are at increased risk for cognitive deficits and axonal loss in the RNFL at the age of 5-6½ years.


Assuntos
Axônios/patologia , Sistema Nervoso Central/fisiopatologia , Transtornos Cognitivos/fisiopatologia , Nervo Óptico/fisiopatologia , Tomografia de Coerência Óptica/métodos , Ultrassonografia Doppler/métodos , Artérias Umbilicais/diagnóstico por imagem , Adulto , Criança , Pré-Escolar , Feminino , Humanos , Recém-Nascido , Recém-Nascido Pequeno para a Idade Gestacional , Percepção , Ultrassonografia Pré-Natal
4.
Mult Scler ; 17(7): 830-7, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21300734

RESUMO

OBJECTIVE: The objective of this research was to study the effect of optic neuritis (ON) on axonal damage in multiple sclerosis (MS) patients. Specifically, we compared changes over 2 years in the retinal nerve fibre layer (RNFL) between affected and contralateral eyes in MS patients with a prior history of ON. METHODS: Thirty-four patients with one unilateral definitive episode of ON were included and underwent a complete ophthalmic examination, optical coherence tomography (OCT), scanning laser polarimetry, visual evoked potentials (VEP) and pattern electroretinogram (pERG). All patients were re-evaluated at 12 and 24 months. Parameters were compared between ON-affected and contralateral eyes in an initial exploration and over the course of the follow-up. Correlations between parameter changes were analysed. RESULTS: RNFL thickness and functional parameters showed more affection in ON eyes (p ≤ 0.05), but changes in measurements during the study were similar between both groups of eyes. CONCLUSIONS: Progressive axonal loss can be detected in the optic nerve, but ON is not a risk factor for increased chronic damage in MS patients without ophthalmic relapses. Loss of the RNFL is caused by progressive degeneration associated with the disease.


Assuntos
Axônios/patologia , Esclerose Múltipla Recidivante-Remitente/diagnóstico , Nervo Óptico/patologia , Neurite Óptica/diagnóstico , Neurônios Retinianos/patologia , Adulto , Idoso , Atrofia , Progressão da Doença , Eletrorretinografia , Potenciais Evocados Visuais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Esclerose Múltipla Recidivante-Remitente/patologia , Esclerose Múltipla Recidivante-Remitente/fisiopatologia , Nervo Óptico/fisiopatologia , Neurite Óptica/patologia , Neurite Óptica/fisiopatologia , Valor Preditivo dos Testes , Medição de Risco , Fatores de Risco , Polarimetria de Varredura a Laser , Espanha , Fatores de Tempo , Tomografia de Coerência Óptica , Campos Visuais , Adulto Jovem
5.
Arch Soc Esp Oftalmol (Engl Ed) ; 94(1): 18-24, 2019 Jan.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-30270036

RESUMO

PURPOSE: To assess structural changes in the retina using optical coherence tomography (OCT) in children prenatally exposed to toxic substances. METHODS: The study included a total of 49 infants, aged between 5 and 18years, exposed to toxic substances during pregnancy. Among the exposed children, 25 were exposed to tobacco, 20 were exposed to alcohol, and 4 children were exposed to other drugs of abuse. All children underwent a complete ophthalmology examination, including an OCT. The results were compared against a control group composed of 25 infants, age matched with controlled pregnancy, and not exposed to toxic substances. RESULTS: Children prenatally exposed to toxic substances showed significantly thinner average retinal nerve fibre layer (RNFL) compared with control children (81.5 vs. 99.7µm; P<.005), as well as RNFL thinning in its four quadrants (superior RNFL: 97.5 vs. 127.5µm; P<.005; nasal RNFL: 61.5 vs. 72.3µm; P<.005; inferior RNFL: 99.8 vs. 128.6µm; P<.005, temporal RNFL: 58.3 vs. 68.2µm; P<.005). Exposed children also exhibited a thinner ganglion cell layer (72.9 vs. 85.9; P<.005). Greater RNFL thinning was observed in children exposed to drugs of abuse (RNFL thinner average=72), followed by children exposed to alcohol (RNFL thinner average=72.9), and finally the least affected were those children exposed to tobacco during pregnancy (RNFL=94.6). CONCLUSION: Toxic substances during pregnancy interfere in retinal development. These results strengthen the evidence about the avoidance of any toxic substance during pregnancy.


Assuntos
Depressores do Sistema Nervoso Central , Etanol , Drogas Ilícitas , Nicotiana , Efeitos Tardios da Exposição Pré-Natal , Retina/crescimento & desenvolvimento , Adolescente , Criança , Pré-Escolar , Estudos Transversais , Feminino , Humanos , Masculino , Análise por Pareamento , Tamanho do Órgão , Gravidez , Análise de Regressão , Retina/efeitos dos fármacos , Retina/patologia , Tomografia de Coerência Óptica , Acuidade Visual
6.
Arch Soc Esp Oftalmol ; 82(10): 615-21, 2007 Oct.
Artigo em Espanhol | MEDLINE | ID: mdl-17929204

RESUMO

PURPOSE: To compare the central corneal thickness, measured with an ultrasound pachymeter, in normal subjects, those with ocular hypertension, glaucoma suspects and patients with preperimetric glaucoma. METHODS: 61 normal eyes (control group), 131 eyes with ocular hypertension, 62 glaucoma suspects (optic nerve head morphology compatible with glaucoma) and 36 patients with preperimetric glaucoma (abnormal short-wavelength automated perimetry) were prospectively and consecutively selected. Scatter plots of central corneal thickness, against the intraocular pressure values were calculated for each of the study groups. Ultrasound pachymetry measurements were compared between those with normal eyes and the other groups. RESULTS: Ocular hypertensive subjects had higher pachymetry values than the control group (p=0.009). No differences were found in the central corneal thickness between normal eyes and those who were glaucoma suspects, and between normal and preperimetric glaucomatous eyes. A mild direct logarithmic correlation was evident between central corneal thickness and the Goldmann tonometry result in the ocular hypertensive group. CONCLUSIONS: Ocular hypertensive subjects had thicker corneas than the other groups studied. Glaucoma suspects and preperimetric glaucoma patients had similar corneal thickness to the control group.


Assuntos
Córnea/patologia , Glaucoma/patologia , Adulto , Idoso , Humanos , Pessoa de Meia-Idade , Hipertensão Ocular/patologia , Estudos Prospectivos
7.
Work ; 57(3): 351-361, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28621697

RESUMO

BACKGROUND: This research was conducted in the Brazilian granite mining sector. After epidemiological studies, it was established that professional pneumoconiosis is related to the inhalation of dust. Therefore, the Brazilian mining health and safety regulatory standard made it compulsory to provide humidification throughout the extraction and mineral treatment processes. OBJECTIVE: To develop the concept of systemic appropriation of the technological innovations that aim to protect the worker's health. Until now, appropriation has usually been presented in its individual dimensions. In this article, the focus is placed on the collective and organizational aspects of this appropriation. METHODS: Two methodological approaches were used: interviews with the different individuals involved in order to report the history of the implementation of technical devices which meet the humidification norm; and ergonomic analysis of the work of the operators who used these devices. RESULTS: The appropriation of the technical devices occurred at two distinct levels: 1) Individual, related to the direct contact of the operator with the instrument; 2) Systemic, as the effects of the innovation propagated through the system affecting interdependent tasks, adaptation of the work organization and new production strategies. CONCLUSIONS: The implementation of prevention norms require innovations which are necessarily accompanied by transformations in the companies' techniques, work and management.


Assuntos
Poeira/prevenção & controle , Mineração/instrumentação , Mineração/métodos , Exposição Ocupacional/prevenção & controle , Dióxido de Silício , Brasil , Ergonomia , Humanos , Mineradores
8.
Res Dev Disabil ; 62: 166-173, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28171826

RESUMO

BACKGROUND: Infants born prematurely or with low birth weight are at increased risk of visual perceptual impairment. Face recognition is a high-order visual ability important for social development, which has been rarely assessed in premature or low birth weight children. AIMS: To evaluate the influence of prematurity and low birth weight on face recognition skills. METHODS: Seventy-seven children were evaluated as part of a prospective cohort study. They were divided into premature and term birth cohorts. Children with a birth weight below the 10th centile were considered small for gestational age. All children underwent a full ophthalmologic assessment and evaluation of face recognition skills using the Facial Memory subtest from the Test of Memory and Learning. RESULTS: Premature infants scored worse on immediate face recognition compared to term infants. However, after adjusting for birth weight, prematurity was not associated with worse outcomes. Independent of gestational age, outcomes of low birth weight children were worse than those of appropriate birth weight children, for immediate face recognition (odds ratio [OR], 5.14; 95% confidence interval [CI], 1.32-21.74) and for face memory (OR, 4.48; 95% CI, 1.14-16.95). CONCLUSIONS: Being born small for gestational age is associated with suboptimal face recognition skills, even in children without major neurodevelopmental problems.


Assuntos
Peso ao Nascer , Reconhecimento Facial/fisiologia , Idade Gestacional , Memória/fisiologia , Prosopagnosia/fisiopatologia , Estudos de Casos e Controles , Criança , Pré-Escolar , Estudos de Coortes , Feminino , Humanos , Recém-Nascido de Baixo Peso , Recém-Nascido Prematuro , Recém-Nascido Pequeno para a Idade Gestacional , Masculino , Estudos Prospectivos , Fatores de Risco
9.
Arch Soc Esp Oftalmol ; 81(3): 135-40, 2006 Mar.
Artigo em Espanhol | MEDLINE | ID: mdl-16572356

RESUMO

PURPOSE: To evaluate the diagnostic ability of the Moorfields regression analysis (MRA; neuroretinal rim sector-based analysis) by means of confocal scanning laser. METHODS: 200 eyes were included in this study: 101 normal subjects and 99 glaucoma patients (standard automated perimetry with glaucomatous defects -MD or CPSD with p<0.02 or a cluster of three or more points with p<0.05 or a cluster of two or more points with p<0.01 or abnormal Glaucoma Hemifield Test). All subjects underwent a full ophthalmic evaluation, visual field evaluation by means of a Humphrey Field Analyzer, 24-2 full threshold strategy, and optic disc topography by Heidelberg retina tomograph (HRT-II). The outcome parameters were sensitivity and specificity of the MRA for each sector. RESULTS: The highest sensitivity in detecting structural defects based on MRA (p<0.05) was observed in the nasal-superior sector (48%) and nasal-inferior sector (45%); however the highest specificity was found in the temporal-superior (98%) and inferior (98%) sectors. The highest sensitivity for MRA (p<0.01) was found in the temporal-inferior sector (31%) and nasal-superior sector (30%) while the temporal-superior and inferior-sectors showed the highest specificity (100%). The diagnosis of glaucoma based on the presence of any sector alteration showed sensitivity figures of 67% with p<0.05 and 46% with p<0.01 and specificity values of 84% with p<0.05 and 96% with p<0.01. CONCLUSIONS: The analysis of the distribution of the neuroretinal rim by means of HRT-II contributes effectively to the diagnosis of glaucoma based on perimetry in a sample derived from a Spanish population.


Assuntos
Glaucoma de Ângulo Aberto/diagnóstico , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos Transversais , Feminino , Glaucoma de Ângulo Aberto/fisiopatologia , Humanos , Masculino , Microscopia Confocal , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Retina/fisiopatologia , Sensibilidade e Especificidade , Testes de Campo Visual/métodos , Campos Visuais
10.
Arch Soc Esp Oftalmol ; 81(4): 205-11, 2006 Apr.
Artigo em Espanhol | MEDLINE | ID: mdl-16688644

RESUMO

PURPOSE: To evaluate the reproducibility of repeated quantitative measurements of optic nerve head topography and retinal nerve fiber layer thickness. METHODS: This study included 32 normal subjects, 41 patients with ocular hypertension and 33 patients with glaucoma. The study groups were defined by the intraocular pressure levels, optic disc stereo-photographs and perimetric performance. Optic disc and retinal nerve fiber layer assessments were performed by ocular coherence tomography (OCT III, Zeiss Instruments). OCT examination was repeated three times in each subject and the coefficient of variability was elaborated for each parameter and group of the study, and compared among them. RESULTS: The average retinal nerve fiber layer thickness measurement showed the best reproducibility figures with a coefficient of variability of 5.9%. The inferior quadrant and the 10, 6 and 7 clock-hours (coefficients of variability 6.3%, 7.4%, 7.5% and 8.6% respectively) showed higher reproducibility. The optic nerve head assessment showed the best reproducibility for the cup-to-disc ratios (vertical, horizontal and area ratios), with a coefficient of variability of 5.0%, 4.2% and 6.6% respectively. Although differences among groups were barely statistically significant, the glaucoma group showed coefficients of variability higher than the other two groups. CONCLUSIONS: Optic nerve head analysis and retinal nerve fiber layer thickness can be reproducibly assessed by OCT. The reproducibility of the device supports its potential use for ocular hypertension follow-up, although its use in glaucoma patients may present difficulties in some parameters.


Assuntos
Disco Óptico/patologia , Doenças do Nervo Óptico/diagnóstico , Células Ganglionares da Retina/patologia , Tomografia de Coerência Óptica , Feminino , Glaucoma/diagnóstico , Humanos , Pressão Intraocular , Masculino , Pessoa de Meia-Idade , Hipertensão Ocular/diagnóstico , Reprodutibilidade dos Testes , Acuidade Visual
11.
Arch Soc Esp Oftalmol ; 81(9): 537-44, 2006 Sep.
Artigo em Espanhol | MEDLINE | ID: mdl-17016786

RESUMO

OBJECTIVE: To compare retinal nerve fiber layer (RNFL) measurements performed with Stratus OCT 3000 in normal, ocular hypertensive, pre-perimetric and glaucomatous eyes. METHODS: 98 normal subjects, 156 ocular hypertensives with short-wavelength automated perimetry (SWAP), 21 ocular hypertensives with altered SWAP (pre-perimetric glaucoma) and 66 glaucomatous eyes were included in the study. Diagnostic groups were classified based on intraocular pressure, optic nerve head appearance, achromatic automatic perimetry and SWAP. RNFL parameters were obtained using a Stratus OCT 3000 (Humphrey Zeiss instruments). RNFL measurements were compared among the groups. RESULTS: RNFL average thickness, superior, inferior and nasal quadrant thickness, and each 12 clock-hour positions except for H9, H10 and H11 showed significant differences between glaucomatous and pre-perimetric glaucoma eyes. RNFL average thickness, inferior quadrant and H10 clock-hour position showed significant differences between normal and ocular hypertensive subjects. Pre-perimetric glaucomas and ocular hypertensives showed differences in H11 clock-hour position exclusively. CONCLUSION: RNFL measurements performed using Stratus OCT showed differences between the study groups. OCT may be as useful as SWAP in early glaucoma diagnosis.


Assuntos
Glaucoma/diagnóstico , Tomografia de Coerência Óptica/métodos , Feminino , Humanos , Pressão Intraocular , Masculino , Pessoa de Meia-Idade , Fibras Nervosas/patologia , Hipertensão Ocular/diagnóstico , Nervo Óptico/patologia , Curva ROC , Células Ganglionares da Retina/patologia , Sensibilidade e Especificidade , Testes de Campo Visual
12.
Arch Soc Esp Oftalmol ; 81(12): 693-700, 2006 Dec.
Artigo em Espanhol | MEDLINE | ID: mdl-17199163

RESUMO

PURPOSE: To evaluate the diagnostic ability of three digital imaging technologies (HRT-II, OCT and GDx VCC) in detecting glaucomatous damage. METHODS: A total of 427 eyes from 427 subjects were included in this cross-sectional study. Each subject was classified as healthy, ocular hypertensive or glaucomatous, according to intraocular pressure levels, standard automated perimetry and optic disc morphology. All of them underwent examination by means of HRT, OCT and GDx VCC. Receiver operating characteristic (ROC) curves were plotted and sensitivities at fixed specificities (85% and 95%) were calculated for each parameter assessed. RESULTS: The parameters with the higher diagnostic ability were: FSM discriminant function from HRT-II (AUC=0.899), retinal nerve fiber layer average thickness from OCT (AUC=0.929) and NFI from GDx VCC (AUC=0.879), with no statistically significant differences between them. CONCLUSION: The HRT-II, OCT and GDx VCC provide measurements of the retinal nerve fiber layer and the optic nerve head with high discriminating ability in open-angle glaucoma.


Assuntos
Técnicas de Diagnóstico Oftalmológico , Glaucoma de Ângulo Aberto/diagnóstico , Lasers , Tomografia de Coerência Óptica , Tomografia/métodos , Idoso , Estudos Transversais , Feminino , Humanos , Pressão Intraocular , Masculino , Pessoa de Meia-Idade , Fibras Nervosas/ultraestrutura , Disco Óptico/ultraestrutura , Curva ROC , Reprodutibilidade dos Testes , Retina/ultraestrutura , Sensibilidade e Especificidade
13.
Res Dev Disabil ; 59: 451-457, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27744269

RESUMO

BACKGROUND: Prematurity and low birth weight are known risk factors for cognitive and developmental impairments, and school failure. Visual perceptual and visual motor skills seem to be among the most affected cognitive domains in these children. AIMS: To assess the influence of prematurity and low birth weight in visual cognitive skills and school performance. METHODS: We performed a prospective cohort study, which included 80 boys and girls in an age range from 5 to 13. Subjects were grouped by gestational age at birth (preterm, <37 weeks; term, 37-42 weeks) and birth weight (small for gestational age (SGA), <10th centile; appropriate weight for gestational age (AGA), ≥10th centile). Each child underwent full ophthalmologic assessment and standardized testing of visual cognitive abilities (Test of Visual Perceptual Skills and Test of Visual Analysis Skills). Parents completed a questionnaire on school performance in children. RESULTS: Figure-ground skill and visual motor integration were significantly decreased in the preterm birth group, compared with term control subjects (figure-ground: 45.7 vs 66.5, p=0.012; visual motor integration, TVAS: (9.9 vs 11.8, p=0.018), while outcomes of visual memory (29.0 vs 47.7, p=0.012), form constancy (33.3 vs 52.8, p=0.019), figure-ground (37.4 vs 65.6, p=0.001), and visual closure (43.7 vs 62.6 p=0.016) testing were lower in the SGA (vs AGA) group. Visual cognitive difficulties corresponded with worse performance in mathematics (r=0.414, p=0.004) and reading (r=0.343, p=0.018). CONCLUSION: Specific patterns of visual perceptual and visual motor deficits are displayed by children born preterm or SGA, which hinder mathematics and reading performance.


Assuntos
Logro , Desenvolvimento Infantil , Cognição , Desempenho Psicomotor , Leitura , Percepção Visual , Adolescente , Peso ao Nascer , Criança , Pré-Escolar , Estudos de Coortes , Feminino , Idade Gestacional , Humanos , Recém-Nascido de Baixo Peso , Recém-Nascido Prematuro , Recém-Nascido Pequeno para a Idade Gestacional , Masculino , Matemática , Destreza Motora , Estudos Prospectivos , Instituições Acadêmicas
14.
Med Clin (Barc) ; 98(14): 545-8, 1992 Apr 11.
Artigo em Espanhol | MEDLINE | ID: mdl-1602856

RESUMO

BACKGROUND: The present forms of carrying out public health care have lead to probably more effective medicine but which at the same time has led to greater risks in violating patients' rights and welfare. At present, a series of arguments are been debated for soliciting the legalization of euthanasia as a form of avoiding possible abuses. Thus, the opinions and attitudes concerning legislation for active euthanasia in terminally ill patients were herein investigated. METHODS: An anonymous survey was elaborated in which 1,109 subjects from three sectors of the population participated: a) hospital personnel (doctors n = 346 and nurses n = 346) of the University Hospital San Carlos in Madrid, b) students (n = 261) of the University Complutense of Madrid, and c) retired people (n = 156) in an old age residence in the province of Madrid (Pinto). The sample was made up of a total of 446 males and 657 females with ages of between 20 and 90 years. RESULTS: Most of those surveyed were in agreement in determined circumstances or totally in agreement with legislation for active euthanasia in terminally ill patients (63%). With respect to acceptation to the practice of legislation for active euthanasia 63% were in agreement in determined circumstances or totally in agreement. Significant differences were found (p less than 0.05) in relation to age, sex, marital status, religion and political ideology of the subjects. CONCLUSIONS: Although the results found in this study concerning the opinions and attitudes on legislation for active euthanasia in terminally ill patients coincided when compared with other existing studies with respect to acceptation for legislation, a less favorable tendency to the same was evident.


Assuntos
Atitude , Eutanásia/legislação & jurisprudência , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Espanha
15.
An Med Interna ; 13(6): 285-7, 1996 Jun.
Artigo em Espanhol | MEDLINE | ID: mdl-8962960

RESUMO

We present a new case of pseudomyxoma peritonei secondary to a mucinous cystadenoma of the ovary, whose presenting symptoms were abdominal distension and bilateral hernias. This is an uncommon entity and diagnosis tends to be casual. Each day, ultrasonography and computed tomography are more useful in suspicion. Aggressive surgical debulking followed by intraperitoneal chemotherapy seem to be the better treatment, even though controversies persist.


Assuntos
Cistadenoma Mucinoso/complicações , Neoplasias Ovarianas/complicações , Pseudomixoma Peritoneal/etiologia , Idoso , Cistadenoma Mucinoso/diagnóstico , Cistadenoma Mucinoso/cirurgia , Feminino , Hérnia Inguinal/etiologia , Humanos , Pseudo-Obstrução Intestinal/etiologia , Pseudo-Obstrução Intestinal/cirurgia , Leiomioma , Linfonodos/patologia , Neoplasias Primárias Múltiplas , Neoplasias Ovarianas/diagnóstico , Neoplasias Ovarianas/cirurgia , Transtornos Respiratórios/complicações , Neoplasias Uterinas
16.
Work ; 41 Suppl 1: 89-94, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22316705

RESUMO

The aim of this paper is to present and discuss a French-Brazilian project (CAPES-COFECUB) centered on the relations between sustainable development, innovation and changes in work activities that accompany these innovations for sustainable development. Sustainable development calls for an integrated approach of three dimensions: social equity, economic viability and environmental sustainability. In order to achieve this integration, considerable innovations efforts are required. However, the work, understood as a productive act, is deeply lacking in the current researches. Starting from the idea that work is a "fundamental need" the goal of this project is to propose innovative methods that can be used for designing production systems from the perspective of sustainable development.


Assuntos
Conservação dos Recursos Naturais , Desenvolvimento de Programas , Carga de Trabalho , Brasil , França , Inovação Organizacional , Política
17.
Case Rep Ophthalmol Med ; 2012: 486167, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-23133771

RESUMO

Case Report. A 47-year-old man presented with blurred vision in the right eye. Ophthalmoscopic examination showed several placoid, pigmented lesions in the posterior pole and midperiphery of the retina of both eyes. Results. Patient referred a cutaneous malignant melanoma on the back skin removed 6 years ago. A systemic workup revealed multiple metastases in liver and spleen. After an exhaustive study we concluded that it was a dissemination of a cutaneous malignant melanoma with bilateral choroidal metastases, liver and spleen metastases. The patient obtained clinical ocular improvement after palliative chemotherapy, although he died in the following months. Pathological examination of the lesions confirmed the diagnosis of choroidal metastases from a malignant cutaneous melanoma. Conclusions. Monitoring patients who have had cutaneous malignant melanoma is very important, since melanoma metastases may occur even many years after the diagnosis of the primary tumor. Choroidal metastases from cutaneous melanoma are uncommon but we should be aware because their appearance worsens prognosis.

18.
Br J Ophthalmol ; 95(10): 1393-6, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21242584

RESUMO

BACKGROUND: To compare the efficacy, cosmesis and tolerance of two non-surgical treatments-imiquimod (IMQ) 5% cream and radiotherapy (RT)-to combat periocular nodular basal cell carcinoma (BCC). METHODS: Twenty-seven patients with clinical and histopathological diagnosis of nodular BCC on the eyelid were included and randomly selected: 15 patients were treated with IMQ 5% cream once daily, 5 days/week for 6 weeks, and 12 patients were treated with RT. RESULTS: All tumours showed histopathological remission within 3 months of the treatment, and sustained clinical remission was documented in each patient after 24 months' follow-up. Treatment tolerability was rated as moderate with IMQ and good with RT. Functional results were better in patients treated with IMQ. Loss of eyelashes was reported for most of the patients treated with RT. CONCLUSIONS: IMQ and RT therapies are effective for treating eyelid nodular BCCs. Cosmesis and functional results were better with IMQ, while tolerability was higher with RT.


Assuntos
Aminoquinolinas/uso terapêutico , Antineoplásicos/uso terapêutico , Carcinoma Basocelular/tratamento farmacológico , Carcinoma Basocelular/radioterapia , Neoplasias Palpebrais/tratamento farmacológico , Neoplasias Palpebrais/radioterapia , Idoso , Idoso de 80 Anos ou mais , Aminoquinolinas/efeitos adversos , Antineoplásicos/efeitos adversos , Carcinoma Basocelular/patologia , Neoplasias Palpebrais/patologia , Feminino , Seguimentos , Humanos , Imiquimode , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Indução de Remissão , Resultado do Tratamento
19.
Arch Soc Esp Oftalmol ; 85(6): 209-14, 2010 Jun.
Artigo em Espanhol | MEDLINE | ID: mdl-21074096

RESUMO

OBJECTIVE: To evaluate the effect of pathogenic treatments in the reduction of the retinal nerve fibre layer (RNFL) in patients with Multiple Sclerosis (MS) by means of ocular imaging technologies. MATERIAL AND METHODS: A total 155 eyes of 79 patients with MS were enrolled in this study. All patients underwent a complete ophthalmic examination including best corrected visual acuity using Snellen chart, colour vision using Ishihara pseudoisochromatic plates, visual field examination, optical coherence tomography (OCT), scanning laser polarimetry (GDx) and visual evoked potentials. The patients were re-evaluated after a one year period and changes were assessed in order to detect differences between treatments using the Anova statistical test. The patients were divided into four groups: 1) Patients without treatment, 2) Patients treated with interferon beta-1a, 3) Subjects who received interferon beta-1b, 4) Patients treated using glatiramer acetate. RESULTS: There were no statistically significant differences between patients with or without treatment and between the four groups (P>0.05, t test), but functional and structural parameters showed greater loss in RNFL thickness in non-treated patients. Temporal quadrant RNFL thickness measured by OCT was the parameter with the highest variation (reduction of 4.97µm in patients without treatment vs 1.08µm in treated patients). CONCLUSIONS: MS pathogenic treatment may be a protective factor in the RNFL loss that is associated to the disease progression. More studies are needed.


Assuntos
Esclerose Múltipla/complicações , Esclerose Múltipla/tratamento farmacológico , Doenças Retinianas/etiologia , Doenças Retinianas/prevenção & controle , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Retina/patologia , Doenças Retinianas/patologia , Adulto Jovem
20.
Case Rep Neurol ; 2(3): 139-144, 2010 Nov 12.
Artigo em Inglês | MEDLINE | ID: mdl-21113284

RESUMO

An unusual presentation of Devic's neuromyelitis optica (NMO) disease associated with bilateral internuclear ophthalmoplegia (INO) is described. A 32-year-old pregnant patient was diagnosed with NMO. First symptoms were headache and sudden visual loss in her right eye (RE). Eighteen months ago, she reported other neurologic symptoms such as paresthesia. Based on her visual field, fundoscopy and Ishihara test, she was diagnosed with retrobulbar neuritis of the RE. After delivery, new neurologic symptoms resembling transverse myelitis appeared. She was treated with methylprednisolone and plasmapheresis, which improved her visual acuity; however, a sudden bilateral INO appeared, with adduction defect and nystagmus with abduction in both eyes. No improvement was obtained after treatment with azathioprine and rituximab. Paresis of the legs and the right arm persisted, but double vision and OIN gradually disappeared. At the end, the patient had a residual exophoria in the RE and nystagmus with abduction in the left eye. Prevalence of NMO is lower than one case per one million inhabitants, and it is not likely to affect the encephalic trunk; furthermore, bilateral INO in NMO is rare. Two major criteria and at least two of the three minor ones are required to confirm a NMO diagnosis, and our patient fulfilled these diagnosis criteria.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA