Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Eur J Nucl Med Mol Imaging ; 40(7): 1057-68, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23613103

RESUMO

PURPOSE: To evaluate the impact of dosimetry based on MAA SPECT/CT for the prediction of response, toxicity and survival, and for treatment planning in patients with hepatocellular carcinoma (HCC) treated with (90)Y-loaded glass microspheres (TheraSphere®). METHODS: TheraSphere® was administered to 71 patients with inoperable HCC. MAA SPECT/CT quantitative analysis was used for the calculation of the tumour dose (TD), healthy injected liver dose (HILD), and total injected liver dose. Response was evaluated at 3 months using EASL criteria. Time to progression (TTP) and overall survival (OS) were evaluated using the Kaplan-Meier method. Factors potentially associated with liver toxicity were combined to construct a liver toxicity score (LTS). RESULTS: The response rate was 78.8%. Median TD were 342 Gy for responding lesions and 191 Gy for nonresponding lesions (p < 0.001). With a threshold TD of 205 Gy, MAA SPECT/CT predicted response with a sensitivity of 100% and overall accuracy of 90%. Based on TD and HILD, 17 patients underwent treatment intensification resulting in a good response rate (76.4%), without increased grade III liver toxicity. The median TTP and OS were 5.5 months (2-9.5 months) and 11.5 months (2-31 months), respectively, in patients with TD <205 Gy and 13 months (10-16 months) and 23.2 months (17.5-28.5 months), respectively, in those with TD >205 Gy (p = 0.0015 and not significant). Among patients with portal vein thrombosis (PVT) (n = 33), the median TTP and OS were 4.5 months (2-7 months) and 5 months (2-8 months), respectively, in patients with TD <205 Gy and 10 months (6-15.2 months) and 21.5 months (12-28.5 months), respectively, in those with TD >205 Gy (p = 0.039 and 0.005). The median OS was 24.5 months (18-28.5 months) in PVT patients with TD >205 Gy and good PVT targeting on MAA SPECT/CT. The LTS was able to detect severe liver toxicity (n = 6) with a sensitivity of 83% and overall accuracy of 97%. CONCLUSION: Dosimetry based on MAA SPECT/CT was able to accurately predict response and survival in patients treated with glass microspheres. This method can be used to adapt the injected activity without increasing liver toxicity, thus defining a new concept of boosted selective internal radiation therapy (B-SIRT). This new concept and LTS enable fully personalized treatment planning with glass microspheres to be achieved.


Assuntos
Carcinoma Hepatocelular/radioterapia , Vidro/química , Neoplasias Hepáticas/radioterapia , Microesferas , Medicina de Precisão/métodos , Carcinoma Hepatocelular/diagnóstico por imagem , Feminino , Humanos , Fígado/efeitos da radiação , Neoplasias Hepáticas/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Radiometria , Planejamento da Radioterapia Assistida por Computador , Estudos Retrospectivos , Segurança , Análise de Sobrevida , Tomografia Computadorizada de Emissão de Fóton Único , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Radioisótopos de Ítrio/efeitos adversos , Radioisótopos de Ítrio/uso terapêutico
2.
Trials ; 18(1): 306, 2017 07 06.
Artigo em Inglês | MEDLINE | ID: mdl-28683837

RESUMO

BACKGROUND: Interventional radiology includes a range of minimally invasive image-guided diagnostic and therapeutic procedures that have become routine clinical practice. Each procedure involves a percutaneous needle insertion, often guided using computed tomography (CT) because of its availability and usability. However, procedures remain complicated, in particular when an obstacle must be avoided, meaning that an oblique trajectory is required. Navigation systems track the operator's instruments, meaning the position and progression of the instruments are visualised in real time on the patient's images. A novel electromagnetic navigation system for CT-guided interventional procedures (IMACTIS-CT®) has been developed, and a previous clinical trial demonstrated improved needle placement accuracy in navigation-assisted procedures. In the present trial, we are evaluating the clinical benefit of the navigation system during the needle insertion step of CT-guided procedures in the thoraco-abdominal region. METHODS/DESIGN: This study is designed as an open, multicentre, prospective, randomised, controlled interventional clinical trial and is structured as a standard two-arm, parallel-design, individually randomised trial. A maximum of 500 patients will be enrolled. In the experimental arm (navigation system), the procedures are carried out using navigation assistance, and in the active comparator arm (CT), the procedures are carried out with conventional CT guidance. The randomisation is stratified by centre and by the expected difficulty of the procedure. The primary outcome of the trial is a combined criterion to assess the safety (number of serious adverse events), efficacy (number of targets reached) and performance (number of control scans acquired) of navigation-assisted, CT-guided procedures as evaluated by a blinded radiologist and confirmed by an expert committee in case of discordance. The secondary outcomes are (1) the duration of the procedure, (2) the satisfaction of the operator and (3) the irradiation dose delivered, with (4) subgroup analysis according to the expected difficulty of the procedure, as well as an evaluation of (5) the usability of the device. DISCUSSION: This trial addresses the lack of published high-level evidence studies in which navigation-assisted CT-guided interventional procedures are evaluated. This trial is important because it addresses the problems associated with conventional CT guidance and is particularly relevant because the number of interventional radiology procedures carried out in routine clinical practice is increasing. TRIAL REGISTRATION: ClinicalTrials.gov identifier: NCT01896219 . Registered on 5 July 2013.


Assuntos
Abdome/diagnóstico por imagem , Fenômenos Eletromagnéticos , Radiografia Intervencionista/instrumentação , Tórax/diagnóstico por imagem , Tomografia Computadorizada por Raios X/instrumentação , Protocolos Clínicos , Desenho de Equipamento , França , Humanos , Agulhas , Valor Preditivo dos Testes , Estudos Prospectivos , Punções , Doses de Radiação , Exposição à Radiação , Interpretação de Imagem Radiográfica Assistida por Computador , Radiografia Intervencionista/efeitos adversos , Radiografia Intervencionista/métodos , Projetos de Pesquisa , Software , Fatores de Tempo , Tomografia Computadorizada por Raios X/efeitos adversos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA