Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Appl Opt ; 40(34): 6292-300, 2001 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-18364935

RESUMO

Results of an intercalibration between the extreme-ultraviolet spectrometers Coronal Diagnostic Spectrometer (CDS) and Solar Ultraviolet Measurements of Emitted Radiation (SUMER) on board the Solar and Heliospheric Observatory (SOHO) are reported. The results of the joint observing program Intercal_01 are described, and intercalibration results up to July 2000 of both SUMER detectors A and B and of the CDS Normal Incidence Spectrometer (NIS) are presented. The instruments simultaneously observed radiance of emission lines at the center of the Sun, and three lines have been chosen for intercomparison: He i 584 A, Mg x 609 A, and Mg x 624 A. Initially the same area was observed by both instruments, but, after restrictions were imposed by the scanning mechanism of SUMER in November 1996, the instruments viewed areas of different sizes. Nevertheless, the temporal correlation between the two instruments remained good through June 1998, when contact with the SOHO spacecraft was lost. Until then the CDS instrument measured (33 ? 5)% and (38 ? 7)% (?1varsigma) higher intensity than SUMER in the He i 584-A line on average for detectors A and B, respectively. Data from SUMER detector B agreed well for Mg x 609 A and Mg x 624 A with the CDS intensities, showing offsets of (2 ? 10)% and (9 ? 15)%, much less than the data of detector A with offsets of (7 ? 8)% and (16 ? 7)% for the two lines, respectively, relative to CDS. Finally, the intercalibration measurements after the loss and recovery of the SOHO spacecraft are analyzed. The data for observations from November 1998 to July 2000 are compared, and it is shown that, although the responses of the instruments have changed, the CDS and the SUMER still perform well, and their temporal correlation is good.

2.
Appl Opt ; 38(34): 7035-46, 1999 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-18324248

RESUMO

The results of an intercalibration between the extreme ultraviolet spectrometers Coronal Diagnostic Spectrometer (CDS) and Solar Ultraviolet Measurements of Emitted Radiation (SUMER) onboard the Solar and Heliospheric Observatory (SOHO) are presented. During the joint observing program Intercal_01, CDS and SUMER were pointed at the same locations in quiet Sun areas and observed in the same wavelength bands located around the spectral lines He i 584 A, Mg x 609 A, and Mg x 624 A. The data sets analyzed here consist of raster images recorded by the CDS normal-incidence spectrometer and SUMER detector A and span the time from March 1996 to August 1996. Effects of the different spatial and spectral resolutions of both instruments have been investigated and taken into account in the analysis. We find that CDS measures generally a 30% higher intensity than SUMER in the He i 584-A line, while it measures 9% and 17% higher intensities in Mg x 609 A and Mg x 624 A, respectively. Both instruments show very good temporal correlation and stability, indicating that solar variations dominate over changes in instrumental sensitivity. Our analysis also provides in-flight estimates of the CDS spatial point-spread functions.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA