RESUMO
PURPOSE: The purpose of this retrospective study is to compare the results of electrically evoked compound action potential (ECAP) measurements using automatic auditory response telemetry (AutoART) with those obtained by ART in adults. The study also aimed to evaluate the predictive value of intraoperative ART and AutoART ECAPs for speech intelligibility (SI) and hearing success (HS), and to determine if cochlear nerve (CN) cross-sectional area (CSA) obtained preoperatively by magnetic resonance imaging (MRI) scans could predict ART and AutoART ECAPs and SI and HS outcome. METHODS: The study analyzed and correlated ART and AutoART ECAP thresholds at electrodes E2, E6, and E10, as well as averaged ECAP thresholds over electrodes E1-E12, using data from 32 implants. Correlations were also examined for ART and AutoART ECAP slopes. In addition, averaged ART and AutoART ECAP thresholds and slopes over all 12 electrodes for each participant were correlated with CN CSA measured from MRI sequences. SI of the monosyllabic Freiburg Speech Test at 65 dB sound pressure level was examined along with averaged ART and AutoART thresholds and slopes over all 12 electrodes. A parallel analysis was performed for HS, derived from the difference between baseline and 6-month SI. Finally, correlations between CN CSA and SI, as well as CN CSA and HS were examined. RESULTS: The results of the study showed a significant positive correlation between ART and AutoART ECAP thresholds and as well as slopes for E2, E6, E10 and averaged thresholds and slopes of E1-E12. However, no significant correlation was observed between ART and AutoART averaged ECAP thresholds and slopes and either SI and HS or CN CSA. Furthermore, no significant correlation was found between CN CSA and SI and HS. CONCLUSION: While AutoART is a reliable and safe program for measuring ECAPs in adults, the study found no preoperative prognostic information on intraoperative ECAP results using parameters extracted from current MRI sequences or pre-/intraoperative information on subsequent hearing outcome using ECAP and CN CSA.
Assuntos
Implantes Cocleares , Nervo Coclear , Potenciais Evocados Auditivos , Imageamento por Ressonância Magnética , Humanos , Nervo Coclear/diagnóstico por imagem , Estudos Retrospectivos , Masculino , Pessoa de Meia-Idade , Feminino , Adulto , Idoso , Imageamento por Ressonância Magnética/métodos , Potenciais Evocados Auditivos/fisiologia , Implante Coclear/métodos , Telemetria/métodos , Inteligibilidade da Fala/fisiologia , Adulto Jovem , Valor Preditivo dos Testes , Limiar Auditivo/fisiologia , Potenciais de Ação/fisiologiaRESUMO
PURPOSE: The focus on treating patients with Menière's Disease (MD) lies on the reduction of vertigo attacks and the preservation of sensory function. Endolympathic hydrops is considered as an epiphenomenon in MD, which can potentially be altered by endolymphatic sac surgery (ESS). Purpose of the study was to investigate the influences on vertigo control through manipulation of the perilymphatic system with or without ESS. METHODS: Retrospective data analysis of 86 consecutive patients with MD according to current diagnostic criteria after endolymphatic sac surgery alone (ESSalone; n = 45), cochlear implantation (CI) alone (CIalone; n = 12), and ESS with CI (ESS + CI; n = 29), treated at a tertiary referral center. MAIN OUTCOME MEASURES: vertigo control, speech perception pre- and postoperatively. RESULTS: Gender, side, and preoperative treatment were similar in all groups. Age was younger in the ESSalone-group with 56.2 ± 13.0 years (CIalone = 64.2 ± 11.4 years; ESS + CI = 63.1 ± 9.7 years). Definitive MD was present in all the CIalone, in 79.3% of the ESS + CI and in 59.6% of the ESSalone-patients. Likewise, vertigo control rate was 100% in the CIalone, 89.7% in the ESS + CI and 66.0% in the ESSalone-group. CONCLUSIONS: Vertigo control was improved in all three groups, however, superior in groups treated with CI, potentially contributed by the manipulation of both the endo- and perilymphatic systems. A more systematic characterization of the patients with larger case numbers and documentation of follow up data would be needed to evaluate a clinical effect more properly.
Assuntos
Implante Coclear , Saco Endolinfático , Doença de Meniere , Percepção da Fala , Humanos , Doença de Meniere/complicações , Doença de Meniere/cirurgia , Doença de Meniere/diagnóstico , Estudos Retrospectivos , Saco Endolinfático/cirurgia , Vertigem/etiologia , Vertigem/cirurgia , Cóclea/cirurgiaRESUMO
PURPOSE: The Oldenburg Sentence Test (OLSA) is a German matrix test designed to determine speech recognition thresholds (SRT). It is widely used for hearing-aids and cochlear implant fitting, but an age-adjusted standard is still lacking. In addition, knowing that the ability to concentrate is an important factor in OLSA performance, we hypothesized that OLSA performance would depend on the time of day it was administered. The aim of this study was to propose an age standardization for the OLSA and to determine its diurnal performance. METHODS: The Gutenberg Health Study is an ongoing population-based study and designed as a single-centre observational, prospective cohort study. Participants were interviewed about common otologic symptoms and tested with pure-tone audiometry and OLSA. Two groups-subjects with and without hearing loss-were established. The OLSA was performed in two runs. The SRT was evaluated for each participant. Results were characterized by age in 5-year cohorts, gender and speech recognition threshold (SRT). A time stamp with an hourly interval was also implemented. RESULTS: The mean OLSA SRT was - 6.9 ± 1.0 dB (group 1 male) and - 7.1 ± 0.8 dB (group 1 female) showing an inverse relationship with age in the whole cohort, whereas a linear increase was observed in those without hearing loss. OLSA-SRT values increased more in males than in females with increasing age. No statistical significance was found for the diurnal performance. CONCLUSIONS: A study with 2900 evaluable Oldenburg Sentence Tests is a novelty and representative for the population of Mainz and its surroundings. We postulate an age- and gender-standardized scale for the evaluation of the OLSA. In fact, with an intergroup standard deviation (of about 1.5 dB) compared to the age dependence of 0.7 dB/10 years, this age normalization should be considered as clinically relevant.
Assuntos
Implantes Cocleares , Surdez , Auxiliares de Audição , Perda Auditiva , Percepção da Fala , Feminino , Humanos , Masculino , Perda Auditiva/diagnóstico , Estudos Prospectivos , Inteligibilidade da Fala , Teste do Limiar de Recepção da Fala/métodosRESUMO
BACKGROUND: The hearing success of patients with bimodal fitting, utilizing both a cochlear implant (CI) and a hearing aid (HA), varies considerably: While some patients benefit from bimodal CI and HA, others do not. OBJECTIVES: This retrospective study aimed to investigate speech perception in bimodally fitted patients and compare it with the cochlear coverage (CC). METHODS: The CC was calculated with the OTOPLAN software, measuring the cochlear duct length on temporal bone CT scans of 39 patients retrospectively. The patients were categorized into two groups: CC ≤â¯65% (CC500) and CC >â¯65% (CC600). Monaural speech intelligibility for monosyllables at a sound pressure level (SPL) of 65â¯dB in a free-field setting was assessed before and after CI at various time points. The two groups, one with preoperative HA and one with postoperative CI, were compared. Additionally, speech intelligibility was correlated with CC in the entire cohort before CI and at the last available follow-up (last observation time, LOT). RESULTS: Overall, there was no significant difference in speech intelligibility between CC500 and CC600 patients, with both groups demonstrating a consistent improvement after implantation. While CC600 patients tended to exhibit earlier improvement in speech intelligibility, CC500 patients showed a slower initial improvement within the first 3 months but demonstrated a steeper learning curve thereafter. At LOT, the two patient groups converged, with no significant differences in expected speech intelligibility. There was no significant relationship between unimodal/unilateral free-field speech intelligibility and CC. Interestingly, patients with a CC of 70-75% achieved the highest speech intelligibility. CONCLUSION: Despite of the lack of a significant correlation between CC and speech perception, patients appeared to reach their maximum in unimodal/unilateral speech perception primarily at a coverage level of 70-75%. Nevertheless, further investigation is warranted, as CC500 was associated with shorter cochlear duct length, and different types of electrodes were used in both groups.
Assuntos
Implante Coclear , Implantes Cocleares , Auxiliares de Audição , Percepção da Fala , Humanos , Estudos RetrospectivosRESUMO
PURPOSE: The aim of the study was to develop the German Hearing in Noise Test (HINT) with female speaker by fulfilling the recommendations by International Collegium of Rehabilitative Audiology (ICRA) for using a female speaker to create new multilingual speech tests and to determine norms and to compare these norms with German male speech tests-the male speakers HINT and the Oldenburg Sentence Test (OLSA). METHODS: The HINT with a female speaker consists of the same speech material as the male speaking HINT. After recording the speech material, 10 normal hearing subjects were included to determine the performance-intensity function (PI function). 24 subjects were part of the measurements to determine the norms and compare them with the norms of male HINT and OLSA. Comparably, adaptive, open-set methods under headphones (HINT) and sound field (OLSA) were used. RESULTS: Acoustic phonetic analysis demonstrated significant difference in mean fundamental frequency, its range and mean speaking rate between both HINT speakers. The calculated norms by three of the tested four conditions of the HINT with a female speaker are not significantly different from the norms with a male speaker. No significant effect of the speaker's gender of the first HINT measurement and no significant correlation between the threshold results of the HINT and the OLSA were determined. CONCLUSIONS: The Norms for German HINT with a female speaker are comparable to the norms of the HINT with a male speaker. The speech intelligibility score of the HINT does not depend on the speakers' gender despite significant difference of acoustic-phonetic parameters between the female and male HINT speaker's voice. Instead, the speech intelligibility rating must be seen as a function of the used speech material.
Assuntos
Ruído , Percepção da Fala , Humanos , Masculino , Feminino , Limiar Auditivo , Mascaramento Perceptivo , Testes Auditivos , Inteligibilidade da Fala , Teste do Limiar de Recepção da Fala/métodosRESUMO
PURPOSE: Treatment of Menière's Disease (MD) comprises an array of both non-destructive and destructive treatment options. In patients who are therapy-refractory to non-destructive medical treatment, endolymphatic mastoid shunt surgery (EMSS) is both recommended and debated controversially. The aim of this study was to investigate safety in terms of hearing, vestibular function, complication rate, and efficacy with regards to vertigo control of EMSS in patients with MD according to the current diagnostic criteria of 2015. METHODS: Retrospective analysis of 47 consecutive patients with definite or probable MD with description of demographic parameters, pre- and postoperative MD treatment, pre- and postoperative audiometric (pure tone audiometry) and vestibular (caloric testing) results. The parameters were compared between patients with and without postoperative vertigo control. RESULTS: 31/47 patients (66.0%) had improved vertigo control postoperatively. Postoperative hearing and vestibular preservation were predominantly stable. No significant differences between patients with improved vertigo control and patients with no change or worse vertigo episodes were found. In the treatment refractory group, 4 patients required a revision EMSS and 6 a destructive MD treatment (5 gentamicin intratympanically, 1 labyrinthectomy). No peri- or postsurgical complications were reported. CONCLUSIONS: EMSS was found to be beneficial in two thirds of the patients with definite or probable Morbus Menière and a safe procedure regarding hearing and vestibular preservation with no postoperative complications. Therefore, EMSS should be considered before inducing destructive treatment options, such as intratympanic gentamicin application or labyrinthectomy.
Assuntos
Anastomose Endolinfática , Doença de Meniere , Vestíbulo do Labirinto , Humanos , Doença de Meniere/complicações , Doença de Meniere/cirurgia , Estudos Retrospectivos , Processo Mastoide/cirurgia , Vertigem/etiologia , Anastomose Endolinfática/efeitos adversos , Gentamicinas/uso terapêuticoRESUMO
BACKGROUND: For patients with single sided deafness (SSD) or severe asymmetric sensorineural hearing loss (ASHL), cochlear implantation remains the only solution to restore bilateral hearing capacity. Prognostically, the duration of hearing loss in terms of audiological outcome is not yet clear. Therefore, the aim of this study was to retrospectively investigate the influence of subjective deafness duration on postoperative speech perception after cochlear implantation for SSD as well as its impact on quality of life. MATERIALS AND METHODS: The present study included a total of 36 adults aged 50.2 ± 15.5 years who underwent CI for SSD/ASHL at our clinic between 2010 and 2015. Patients were audiometrically assessed at 3 and 12-36 months postoperatively. Test results were correlated with self-reported duration of deafness. Quality of life was assessed by questionnaire. RESULTS: Mean duration of deafness was 193.9 ± 185.7 months. The side-separated hearing threshold showed an averaged target range between 30 and 40 dB HL. Freiburg monosyllable test increased from 0% pre-operatively to 20% after 3 months (p = 0.001) and to 50% after 12-36 months (p = 0.002). There was a significant correlation between audiometric outcome and subjective deafness duration at 12-36 months postoperatively (r = - 0.564; p = 0.02) with a cutoff for open-set monosyllable recognition at a duration of deafness of greater than 408 months. Quality of life was significantly improved by CI. CONCLUSIONS: CI implantation in unilaterally deafened patients provides objective and subjective benefits. Duration of deafness is unlikely to be an independent negative predictive factor and thus should not generally be considered as contraindication.
Assuntos
Implante Coclear , Implantes Cocleares , Surdez , Perda Auditiva Neurossensorial , Perda Auditiva Unilateral , Percepção da Fala , Adulto , Humanos , Perda Auditiva Unilateral/cirurgia , Inteligibilidade da Fala , Surdez/cirurgia , Surdez/reabilitação , Estudos Retrospectivos , Qualidade de Vida , Resultado do Tratamento , Audição , Perda Auditiva Neurossensorial/cirurgiaRESUMO
BACKGROUND: Hearing success in bimodally hearing patients with a cochlear implant (CI) and a hearing aid (HA) exhibits different results: while some benefit from bimodal CI and HA, others do not. OBJECTIVE: The aim of this study was to investigate hearing success in terms of speech perception in bimodally fitted patients in relation to the cochlear coverage (CC) of the CI electrodes. MATERIALS AND METHODS: Using the OTOPLAN software (CAScination AG, Bern, Switzerland), CC was retrospectively measured from CT scans of the temporal bone of 39 patients, who were then categorized into two groups: CCâ¯≤ 65% (CC500) and CCâ¯> 65% (CC600). Monaural speech intelligibility for monosyllables at a sound pressure level (SPL) of 65â¯dB in open field was assessed at various timepoints, preoperatively with HA and postoperatively with CI, and compared between the groups. In addition, speech intelligibility was correlated with CC in the entire cohort before surgery and during follow-up (FU). RESULTS: Overall, no significant differences in speech intelligibility were found between CC500 and CC600 patients at any of the FU timepoints. However, both CC500 and CC600 patients showed a steady improvement in speech intelligibility after implantation. While CC600 patients tended to show an earlier improvement in speech intelligibility, CC500 patients tended to show a slower improvement during the first 3 months and a steeper learning curve thereafter. The two patient groups converged during FU, with no significant differences in speech intelligibility. There was no significant relationship between unimodal/unilateral free-field speech intelligibility and CC. However, patients with a CC of 70-75% achieved maximum speech intelligibility. CONCLUSION: Despite a nonsignificant correlation between CC and speech discrimination, patients seem to reach their maximum in unimodal/unilateral speech understanding mainly at 70-75% coverage. However, there is room for further investigation, as CC500 was associated with a shorter cochlear duct length (CDL), and long and very long electrodes were used in both groups.
Assuntos
Implante Coclear , Implantes Cocleares , Percepção da Fala , Humanos , Estudos Retrospectivos , AudiçãoRESUMO
OBJECTIVES: In pediatric audiology, objective techniques for hearing threshold estimation in infants and children with profound or severe hearing loss play a key role. Auditory brainstem responses (ABR) and auditory steady-state responses (ASSR) are available for frequency-dependent hearing threshold estimations and both techniques show strong correlations but sometimes with considerable differences. The aim of the study was to compare hearing threshold estimations in children with and without cochlear and cochlear nerve malformations. METHODS: Two groups with profound or severe hearing loss were retrospectively compared. In 20 ears (15 children) with malformation of the inner ear and/or cochlear nerve hypoplasia and a control group of 20 ears (11 children) without malformation, ABR were measured with the Interacoustics Eclipse EP25 ABR system® (Denmark) with narrow-band CE-chirps® at 500, 1000, 2000 and 4000 Hz and compared to ASSR at the same center frequencies under similar conditions. RESULTS: ABR and ASSR correlated significantly in both groups (r = 0.413 in malformation group, r = 0.82 in control group). The malformation group showed a significantly lower percentage of "equal" hearing threshold estimations than the control group. In detail, patients with isolated cochlear malformation did not differ significantly from the control group, whereas patients with cochlear nerve hypoplasia showed significantly greater differences. CONCLUSION: ABR and ASSR should be used jointly in the diagnostic approach in children with suspected profound or severe hearing loss. A great difference in hearing threshold estimation between these techniques could hint at the involvement of cochlear nerve or cochlear nerve hypoplasia itself.
Assuntos
Potenciais Evocados Auditivos do Tronco Encefálico , Perda Auditiva , Estimulação Acústica/métodos , Limiar Auditivo/fisiologia , Criança , Nervo Coclear , Potenciais Evocados Auditivos do Tronco Encefálico/fisiologia , Perda Auditiva/diagnóstico , Humanos , Lactente , Estudos RetrospectivosRESUMO
Correct execution of hearing tests is essential for audiologic diagnostics and selection of treatment by the ENT physician. Especially in the case of pure-tone and speech audiometry, incorrectly performed audiometric masking can lead to false measurement results. Often, hearing that is too good is feigned by overhearing in the contralateral ear. Herein, a masking strategy is described by which errors in the execution of masking can be recognized and corrected. The aim of this paper is to identify and prevent the most common errors made during the masking process in pure-tone and speech audiometry.
Assuntos
Audiometria , Percepção da Fala , Audiometria de Tons Puros/métodos , Audiometria da Fala , Limiar Auditivo , Audição , Mascaramento PerceptivoRESUMO
OBJECTIVES: The aims of this study were to develop a German Hearing In Noise Test (HINT) using the same methodology as with previous HINT tests; to develop sentence lists for measuring speech reception thresholds (SRTs); and to determine test-retest reliability and norms for measures obtained under headphones. DESIGN: The following steps were followed: develop and record sentences, synthesise masking noise, determine the performance-intensity (PI) function, equalise sentence difficulty in the masking noise. Form sentence lists of equal difficulty. Measure SRTs for normal hearing individuals to determine practice/learning effects, test-retest reliability, and norms. STUDY SAMPLE: Three groups of adults (median age = 25 years) with average better ear pure-tone averages (PTAs) ≤ 5 dB HL participated. RESULTS: The 12 20-sentence lists were well-matched phonemically and did not differ significantly in difficulty. Test-retest reliability 95% confidence intervals ranged from 1.3 to 2.5 dB. Norms in quiet and in noise exhibited the same pattern as those for other HINT languages. German norms were approximately 2 dB lower than other languages in the noise conditions. CONCLUSIONS: The German HINT materials are comparable to those for other languages and are partially consistent with recommendations for construction of multilingual speech tests. They can be used for comparing and pooling research results from the international research community.
Assuntos
Idioma , Percepção da Fala , Adulto , Audição , Humanos , Reprodutibilidade dos Testes , Teste do Limiar de Recepção da FalaRESUMO
PURPOSE: Free text reports (FTR) of head and neck ultrasound studies are currently deployed in most departments. Because of a lack of composition and language, these reports vary greatly in terms of quality and reliability. This may impair the learning process during residency. The purpose of the study was to analyze the longitudinal effects of using structured reports (SR) of head and neck ultrasound studies during residency. METHODS: Attending residents (n = 24) of a tripartite course on head and neck ultrasound, accredited by the German Society for Ultrasound in Medicine (DEGUM), were randomly allocated to pictures of common diseases. Both SRs and FTRs were compiled. All reports were analyzed concerning completeness, acquired time and legibility. Overall user contentment was evaluated by a questionnaire. RESULTS: SRs achieved significantly higher ratings regarding completeness (95.6% vs. 26.4%, p < 0.001), description of pathologies (72.2% vs. 58.9%, p < 0.001) and legibility (100% vs. 52.4%, p < 0.001) with a very high inter-rater reliability (Fleiss' kappa 0.9). Reports were finalized significantly faster (99.1 s vs. 115.0 s, p < 0.001) and user contentment was significantly better when using SRs (8.3 vs. 6.3, p < 0.001). In particular, only SRs showed a longitudinally increasing time efficiency (- 20.1 s, p = 0.036) while maintaining consistent completeness ratings. CONCLUSIONS: The use of SRs of head and neck ultrasound studies results in an increased longitudinal time-efficiency while upholding the report quality at the same time. This may indicate an additive learning effect of structured reporting. Superior outcomes in terms of comprehensiveness, legibility and time-efficiency can be observed immediately after implementation.
Assuntos
Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Internato e Residência/normas , Prontuários Médicos/normas , Ultrassonografia/normas , Adulto , Documentação/normas , Feminino , Controle de Formulários e Registros/normas , Cabeça/diagnóstico por imagem , Humanos , Masculino , Pescoço/diagnóstico por imagem , Sistemas de Informação em Radiologia/normas , Reprodutibilidade dos Testes , Inquéritos e QuestionáriosRESUMO
PURPOSE: Wideband-tympanometry (WBT) could give more informative data about the tympanic condition than the conventional tympanometry. In the actual literature, the clinical profit of wideband-tympanometry in pediatric audiological settings is not well evaluated. The aim of this study was to analyze the additional clinical benefit. METHODS: 150 children (281 ears) with normal hearing, at the age from 11 days up to 14;10 years, checked with pure tone audiometry or auditory brainstem responses (ABR) participated in this retrospective study. We divided in four age ranges (≤ 6 month; > 6 month ≤ 3 years; > 3 years ≤ 11 years; > 11 years). All children were evaluated with ENT examination including ear microscopy, conventional 226-Hz or 1000-Hz tympanometry and WBT. Ear canal volumes were determined. RESULTS: Compared with literature data, our patients aged ≤ 3 years showed smaller mean ear canal volumes (≤ 4 ml). We found a good statistical correlation between the WBT-results and 1000-Hz tympanometry but a rare correlation between WBT-results and ear microscopic findings. In the patients with pathologic ear microscopic results in all groups of age, a significant reduction of WBT-absorbance in 1000 Hz and 2000 Hz was found. CONCLUSIONS: This study confirms that WBT collects additive data to detect the correct middle ear status. In pediatric audiology, WBT is an additional useful method to value middle ear problems and to analyze the character of infantile hearing loss. Standard guidelines for the interpretation of the pediatric population are needed. Hence, it will be necessary to determine these findings in a larger number of infantile ears.
Assuntos
Testes de Impedância Acústica/métodos , Perda Auditiva/diagnóstico , Adolescente , Fatores Etários , Audiologia , Audiometria de Tons Puros/métodos , Criança , Pré-Escolar , Meato Acústico Externo/anatomia & histologia , Potenciais Evocados Auditivos do Tronco Encefálico , Feminino , Perda Auditiva/etiologia , Humanos , Lactente , Masculino , Otite Média com Derrame/complicações , Otite Média com Derrame/diagnóstico , Estudos Retrospectivos , Membrana TimpânicaRESUMO
There is currently no standardized method for reporting audiological, surgical and subjective outcome measures in clinical trials with active middle ear implants (AMEIs). It is often difficult to compare studies due to data incompatibility and to perform meta-analyses across different centres is almost impossible. A committee of ENT and audiological experts from Germany, Austria and Switzerland decided to address this issue by developing new minimal standards for reporting the outcomes of AMEI clinical trials. The consensus presented here aims to provide a recommendation to enable better inter-study comparability.
Assuntos
Auxiliares de Audição , Perda Auditiva Neurossensorial/cirurgia , Prótese Ossicular , Avaliação de Resultados em Cuidados de Saúde/normas , Áustria , Consenso , Alemanha , Audição , Testes Auditivos , Humanos , Suíça , Resultado do TratamentoRESUMO
OBJECTIVE: A psychoacoustic procedure designed for the precise assessment of perceptional threshold (T-level) in cochlear implant (CI) users is presented. The impact of this procedure on speech perception was investigated. DESIGN: Individual T-level measurements were obtained with the proposed procedure and three different speech processor fitting conditions were applied: (1) fitting familiar to the subject, T-levels unchanged, (2) T-level set to thresholds determined with the new procedure, (3) T-level set to thresholds determined with the new procedure, but T-level is decreased by 10 clinical units (CU). The impact of the different fitting conditions was measured by means of categorical loudness scaling (CLS) and speech perception tests in quiet and noise. STUDY SAMPLE: A prospective study at a tertiary referral university hospital. 18 experienced postlingually deafened cochlear implanted adult subjects. RESULTS: Average sound-field thresholds obtained by CLS were lowest in condition using the new procedure yielding a larger dynamic range with significantly higher speech scores in quiet compared to those with a subject's commonly used programme, and significantly improved in noise even after reducing T-levels by 10 CU. CONCLUSION: The precise determination of T-levels by means of the proposed procedure improved performance in several speech recognition tasks. Compared to the default behavioural setting, T-level increased on median by 9 CU. Average speech reception threshold in noise for soft speech levels (50 dB sound pressure level) decreased by 1 dB.
Assuntos
Limiar Auditivo , Implantes Cocleares/psicologia , Surdez/psicologia , Percepção da Fala , Teste do Limiar de Recepção da Fala/métodos , Adulto , Idoso , Surdez/terapia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Ruído , Estudos Prospectivos , Adulto JovemRESUMO
The aim of this study was to examine the functional hearing results regarding speech perception and auditory sound localization in a high-resolution directional hearing setup following implantation with a new bone conduction device (MED-EL Bonebridge, Innsbruck, Austria). In addition, we assessed the patient acceptance of the Bonebridge system using a questionnaire. The study design is retrospective study. The setting is University Hospital Frankfurt. 18 patients implanted with a Bonebridge device from May 2012 to January 2015 were participated in this study. Speech perception in quiet was tested with the Freiburg monosyllable test at a presentation level of 65 dB SPL. Speech perception in noise was tested post-operatively with the Oldenburg sentence test (OLSA) in best-aided condition. We assessed auditory sound localization with a high-resolution directional hearing setup. To evaluate the acceptance by patients using the Bonebridge in daily life, we used a modified questionnaire. The overall average of functional hearing gain (n = 18) was 29.3 dB (±20.7 dB). Speech perception of monosyllabic words in quiet improved by 20.7% on average, compared with the pre-operative aided condition. Mean speech reception thresholds (SRTs) of the Oldenburg sentence test (OLSA) improved significantly from -3.8 dB SNR (range -5.7 to 5.8 dB SNR) to -5.2 dB SNR (range -6.3 to -0.6 dB SNR) after implantation. Regarding localization abilities, no significant difference was found between the unaided and aided conditions following Bonebridge implantation. A survey of patients' acceptance and handling of the Bonebridge implant in daily life revealed high patient satisfaction. All patients accepted and benefited from the implanted system. No infections or adverse surgical effects occurred. Speech perception significantly improved in quiet and in noise. No significant difference in sound localization was observed. Acceptance of the Bonebridge implant, tested with a modified questionnaire, was high.
Assuntos
Condução Óssea/fisiologia , Auxiliares de Audição/normas , Perda Auditiva/cirurgia , Implantação de Prótese/instrumentação , Localização de Som , Percepção da Fala/fisiologia , Adulto , Idoso , Áustria , Feminino , Testes Auditivos/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Ruído/efeitos adversos , Satisfação do Paciente , Desenho de Prótese , Melhoria de Qualidade , Estudos Retrospectivos , Inquéritos e QuestionáriosRESUMO
BACKGROUND: While hearing aids for a contralateral routing of signals (CROS-HA) and bone conduction devices have been the traditional treatment for single-sided deafness (SSD) and asymmetric hearing loss (AHL), in recent years, cochlear implants (CIs) have increasingly become a viable treatment choice, particularly in countries where regulatory approval and reimbursement schemes are in place. Part of the reason for this shift is that the CI is the only device capable of restoring bilateral input to the auditory system and hence of possibly reinstating binaural hearing. Although several studies have independently shown that the CI is a safe and effective treatment for SSD and AHL, clinical outcome measures in those studies and across CI centers vary greatly. Only with a consistent use of defined and agreed-upon outcome measures across centers can high-level evidence be generated to assess the safety and efficacy of CIs and alternative treatments in recipients with SSD and AHL. METHODS: This paper presents a comparative study design and minimum outcome measures for the assessment of current treatment options in patients with SSD/AHL. The protocol was developed, discussed, and eventually agreed upon by expert panels that convened at the 2015 APSCI conference in Beijing, China, and at the CI 2016 conference in Toronto, Canada. RESULTS: A longitudinal study design comparing CROS-HA, BCD, and CI treatments is proposed. The recommended outcome measures include (1) speech in noise testing, using the same set of 3 spatial configurations to compare binaural benefits such as summation, squelch, and head shadow across devices; (2) localization testing, using stimuli that rove in both level and spectral content; (3) questionnaires to collect quality of life measures and the frequency of device use; and (4) questionnaires for assessing the impact of tinnitus before and after treatment, if applicable. CONCLUSION: A protocol for the assessment of treatment options and outcomes in recipients with SSD and AHL is presented. The proposed set of minimum outcome measures aims at harmonizing assessment methods across centers and thus at generating a growing body of high-level evidence for those treatment options.
Assuntos
Implante Coclear/métodos , Consenso , Surdez/reabilitação , Auxiliares de Audição , Perda Auditiva Unilateral/reabilitação , Percepção da Fala , Implantes Cocleares , Surdez/fisiopatologia , Perda Auditiva Unilateral/fisiopatologia , Humanos , Estudos Longitudinais , Ruído , Estudos Prospectivos , Qualidade de Vida , Localização de Som , Inquéritos e Questionários , Zumbido , Resultado do TratamentoRESUMO
OBJECTIVE: The aim of this study is to simulate speech perception with combined electric-acoustic stimulation (EAS), verify the advantage of combined stimulation in normal-hearing (NH) subjects, and then compare it with cochlear implant (CI) and EAS user results from the authors' previous study. Furthermore, an automatic speech recognition (ASR) system was built to examine the impact of low-frequency information and is proposed as an applied model to study different hypotheses of the combined-stimulation advantage. Signal-detection-theory (SDT) models were applied to assess predictions of subject performance without the need to assume any synergistic effects. DESIGN: Speech perception was tested using a closed-set matrix test (Oldenburg sentence test), and its speech material was processed to simulate CI and EAS hearing. A total of 43 NH subjects and a customized ASR system were tested. CI hearing was simulated by an aurally adequate signal spectrum analysis and representation, the part-tone-time-pattern, which was vocoded at 12 center frequencies according to the MED-EL DUET speech processor. Residual acoustic hearing was simulated by low-pass (LP)-filtered speech with cutoff frequencies 200 and 500 Hz for NH subjects and in the range from 100 to 500 Hz for the ASR system. Speech reception thresholds were determined in amplitude-modulated noise and in pseudocontinuous noise. Previously proposed SDT models were lastly applied to predict NH subject performance with EAS simulations. RESULTS: NH subjects tested with EAS simulations demonstrated the combined-stimulation advantage. Increasing the LP cutoff frequency from 200 to 500 Hz significantly improved speech reception thresholds in both noise conditions. In continuous noise, CI and EAS users showed generally better performance than NH subjects tested with simulations. In modulated noise, performance was comparable except for the EAS at cutoff frequency 500 Hz where NH subject performance was superior. The ASR system showed similar behavior to NH subjects despite a positive signal-to-noise ratio shift for both noise conditions, while demonstrating the synergistic effect for cutoff frequencies ≥300 Hz. One SDT model largely predicted the combined-stimulation results in continuous noise, while falling short of predicting performance observed in modulated noise. CONCLUSIONS: The presented simulation was able to demonstrate the combined-stimulation advantage for NH subjects as observed in EAS users. Only NH subjects tested with EAS simulations were able to take advantage of the gap listening effect, while CI and EAS user performance was consistently degraded in modulated noise compared with performance in continuous noise. The application of ASR systems seems feasible to assess the impact of different signal processing strategies on speech perception with CI and EAS simulations. In continuous noise, SDT models were largely able to predict the performance gain without assuming any synergistic effects, but model amendments are required to explain the gap listening effect in modulated noise.
Assuntos
Estimulação Acústica , Implantes Cocleares , Estimulação Elétrica , Percepção da Fala , Interface para o Reconhecimento da Fala , Adulto , Estudos de Casos e Controles , Implante Coclear , Simulação por Computador , Feminino , Humanos , Masculino , Modelos Teóricos , Ruído , Razão Sinal-Ruído , Adulto JovemRESUMO
INTRODUCTION: Electrically evoked compound action potentials (ECAPs) are used for intra-/postoperative monitoring with intracochlear stimulation of cochlear implants. ECAPs are recorded in MED-EL (Innsbruck, Austria) implants using auditory response telemetry (ART), which has been further developed with automatic threshold determination as AutoART. The success of an ECAP measurement also depends on the number of available spiral ganglion cells and the bipolar neurons of the cochlear nerve (CN). It is assumed that a higher population of spiral ganglion cell implies a larger CN cross-sectional area (CSA), which consequently affects ECAP measurements. METHODS: Intraoperative ECAP measurements from 19 implanted ears of children aged 8 to 18 months were retrospectively evaluated. A comparison and correlation of ART/AutoART ECAP thresholds/slopes at electrodes E2 (apical), E6 (medial), E10 (basal), and averaged E1 to E12 with CN CSA on magnetic resonance imaging was performed. RESULTS: A Pearson correlation of the ART/AutoART ECAP thresholds/slopes for E2/E6/E10 and the averaged electrodes E1 to E12 showed a significant correlation. The CN CSA did not correlate significantly with the averaged ART/AutoART ECAP thresholds/slopes across all 12 electrodes. SUMMARY: AutoART provides reliable measurements and is therefore a suitable alternative to ART. No significant influence of CN CSA on ECAP thresholds/slopes was observed. A predictive evaluation of the success of ECAP measurements based on CN CSA for a clinical setting cannot be made according to the present data.
Assuntos
Implante Coclear , Implantes Cocleares , Criança , Lactente , Humanos , Pré-Escolar , Estudos Retrospectivos , Potenciais Evocados Auditivos/fisiologia , Implante Coclear/métodos , Nervo Coclear/fisiologia , Potenciais de Ação/fisiologia , Estimulação ElétricaRESUMO
OBJECTIVE: The aim of the study was to measure and compare speech perception in users of electric-acoustic stimulation (EAS) supported by a hearing aid in the unimplanted ear and in bilateral cochlear implant (CI) users under different noise and sound field conditions. Gap listening was assessed by comparing performance in unmodulated and modulated Comité Consultatif International Téléphonique et Télégraphique (CCITT) noise conditions, and binaural interaction was investigated by comparing single source and multisource sound fields. METHODS: Speech perception in noise was measured using a closed-set sentence test (Oldenburg Sentence Test, OLSA) in a multisource noise field (MSNF) consisting of a four-loudspeaker array with independent noise sources and a single source in frontal position (S0N0). Speech simulating noise (Fastl-noise), CCITT-noise (continuous), and OLSA-noise (pseudo continuous) served as noise sources with different temporal patterns. Speech tests were performed in two groups of subjects who were using either EAS (n = 12) or bilateral CIs (n = 10). All subjects in the EAS group were fitted with a high-power hearing aid in the opposite ear (bimodal EAS). The average group score on monosyllable in quiet was 68.8% (EAS) and 80.5% (bilateral CI). A group of 22 listeners with normal hearing served as controls to compare and evaluate potential gap listening effects in implanted patients. RESULTS: Average speech reception thresholds in the EAS group were significantly lower than those for the bilateral CI group in all test conditions (CCITT 6.1 dB, p = 0.001; Fastl-noise 5.4 dB, p < 0.01; Oldenburg-(OL)-noise 1.6 dB, p < 0.05). Bilateral CI and EAS user groups showed a significant improvement of 4.3 dB (p = 0.004) and 5.4 dB (p = 0.002) between S0N0 and MSNF sound field conditions respectively, which signifies advantages caused by bilateral interaction in both groups. Performance in the control group showed a significant gap listening effect with a difference of 6.5 dB between modulated and unmodulated noise in S0N0, and a difference of 3.0 dB in MSNF. The ability to "glimpse" into short temporal masker gaps was absent in both groups of implanted subjects. CONCLUSIONS: Combined EAS in one ear supported by a hearing aid on the contralateral ear provided significantly improved speech perception compared with bilateral cochlear implantation. Although the scores for monosyllable words in quiet were higher in the bilateral CI group, the EAS group performed better in different noise and sound field conditions. Furthermore, the results indicated that binaural interaction between EAS in one ear and residual acoustic hearing in the opposite ear enhances speech perception in complex noise situations. Both bilateral CI and bimodal EAS users did not benefit from short temporal masker gaps, therefore the better performance of the EAS group in modulated noise conditions could be explained by the improved transmission of fundamental frequency cues in the lower-frequency region of acoustic hearing, which might foster the grouping of auditory objects.