Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
BMC Anesthesiol ; 21(1): 205, 2021 08 16.
Artigo em Inglês | MEDLINE | ID: mdl-34399681

RESUMO

BACKGROUND: Anesthesia leads to impairments in central and peripheral thermoregulatory responses. Inadvertent perioperative hypothermia is hence a common perioperative complication, and is associated with coagulopathy, increased surgical site infection, delayed drug metabolism, prolonged recovery, and shivering. However, surveys across the world have shown poor compliance to perioperative temperature management guidelines. Therefore, we evaluated the prevalent practices and attitudes to perioperative temperature management in the Asia-Pacific region, and determined the individual and institutional factors that lead to noncompliance. METHODS: A 40-question anonymous online questionnaire was distributed to anesthesiologists and anesthesia trainees in six countries in the Asia-Pacific (Singapore, Malaysia, Philippines, Thailand, India and South Korea). Participants were polled about their current practices in patient warming and temperature measurement across the preoperative, intraoperative and postoperative periods. Questions were also asked regarding various individual and environmental barriers to compliance. RESULTS: In total, 1154 valid survey responses were obtained and analyzed. 279 (24.2%) of respondents prewarm, 508 (44.0%) perform intraoperative active warming, and 486 (42.1%) perform postoperative active warming in the majority of patients. Additionally, 531 (46.0%) measure temperature preoperatively, 767 (67.5%) measure temperature intraoperatively during general anesthesia, and 953 (82.6%) measure temperature postoperatively in the majority of patients. The availability of active warming devices in the operating room (p < 0.001, OR 10.040), absence of financial restriction (p < 0.001, OR 2.817), presence of hospital training courses (p = 0.011, OR 1.428), and presence of a hospital SOP (p < 0.001, OR 1.926) were significantly associated with compliance to intraoperative active warming. CONCLUSIONS: Compliance to international perioperative temperature management guidelines in Asia-Pacific remains poor, especially in small hospitals. Barriers to compliance were limited temperature management equipment, lack of locally-relevant standard operating procedures and training. This may inform international guideline committees on the needs of developing countries, or spur local anesthesiology societies to publish their own national guidelines.


Assuntos
Temperatura Corporal , Hipotermia/prevenção & controle , Monitorização Intraoperatória , Assistência Perioperatória , Padrões de Prática Médica/estatística & dados numéricos , Anestesiologistas , Ásia , Estudos Transversais , Humanos , Complicações Intraoperatórias/prevenção & controle , Inquéritos e Questionários
2.
J Anesth ; 30(6): 1063-1066, 2016 12.
Artigo em Inglês | MEDLINE | ID: mdl-27510560

RESUMO

We report a case of drug-induced myoclonus possibly related to palonosetron, a second-generation 5-hydroxytryptamine-3 receptor antagonist which was administered as a prophylaxis for postoperative nausea and vomiting in a 28-year-old female. The recurrent episodes of myoclonus jerk involving the head, neck and shoulder persisted for a period of 4 days. The patient also exhibited an episode of severe bradycardia leading to hypotension 7 h after surgery. To our knowledge, this is the first report presenting these adverse events potentially associated with the use of palonosetron.


Assuntos
Antieméticos/efeitos adversos , Isoquinolinas/efeitos adversos , Mioclonia/induzido quimicamente , Quinuclidinas/efeitos adversos , Adulto , Antieméticos/uso terapêutico , Feminino , Humanos , Isoquinolinas/uso terapêutico , Palonossetrom , Náusea e Vômito Pós-Operatórios/prevenção & controle , Quinuclidinas/uso terapêutico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA