Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
2.
J Clin Med ; 13(10)2024 May 08.
Artigo em Inglês | MEDLINE | ID: mdl-38792300

RESUMO

Background: Retrograde intrarenal surgery (RIRS) using flexible ureterorenoscopes is a cornerstone approach for renal stone removal, yet it carries a significant risk of postoperative urinary tract infection (UTI). With the emergence of single-use ureterorenoscopes, there is growing interest in their potential to mitigate this risk. This study aimed to compare the postoperative infection rates between single-use and multi-use ureterorenoscopes in RIRS procedures and to identify predictors of postoperative UTI. Methods: Data were collected from 112 consecutive patients who underwent RIRS for renal stones between March 2022 and September 2023. Peri-operative variables including age, gender, body mass index (BMI), stone size, stone location, type of ureterorenoscope, Hounsfield Units (HU), pre-operative hydronephrosis, laboratory analysis, and operative time were evaluated. Univariate and multivariate logistic regression analyses were performed to assess the predictors of postoperative UTI. Results: Of the cohort, 77 surgeries (68.7%) utilized multi-use ureterorenoscopes, while 35 (31.3%) utilized single-use devices. Stone diameter, number of stones, type of ureterorenoscope, and operative time were significant predictors of postoperative UTI in the univariate analysis. Multivariable logistic regression showed that operative time (OR, 1.3; 95% CI, 0.55-0.99; p = 0.03) and type of ureterorenoscope (multi-use vs. single-use) (OR, 1.14; 95% CI, 1.08-1.2; p < 0.001) were independent predictors of postoperative UTI. Conclusions: In conclusion, this study highlights that multi-use ureterorenoscopes and prolonged operative time are associated with an increased risk of postoperative UTI in RIRS procedures. Careful pre-operative evaluation and meticulous patient selection are essential to minimize the occurrence of postoperative UTIs and optimize patient outcomes in RIRS for renal stones.

3.
J Pers Med ; 13(6)2023 Jun 19.
Artigo em Inglês | MEDLINE | ID: mdl-37374002

RESUMO

In the age of information, new platforms are consulted by patients to acquire consciousness about medical treatments. The aim of this study was to assess the level of understanding and feasibility of video consensus (VC) administration in patients scheduled for radical prostatectomy (RP), comparing it with standard informed consensus (SIC). According to the European Association of Urology Patient Information, we set up a video content for RP that was translated in Italian and implemented with information about possible perioperative and postoperative complications, days of hospitalization etc. From 2021 to 2022, all patients undergoing RP at our institution were prospectively included in this study. Patients received an SIC and after that, a VC about RP. After two consensuses were administered, patients received a preformed Likert 10 scale and STAI questionnaires. On the RP dataset, 276 patients were selected and 552 questionnaires for both SIC and VC were evaluated. Out of these, the median age was 62 years (IQR 60-65). Patients reported a higher overall satisfaction for VC (8.8/10) compared to the traditional informed consent (6.9/10). Therefore, VC may play a role in the future of surgery, improving the consciousness and satisfaction of patients and reducing preoperative anxiety.

4.
J Pers Med ; 13(8)2023 Aug 06.
Artigo em Inglês | MEDLINE | ID: mdl-37623483

RESUMO

Since its introduction in the early 2000s, robotic surgery has represented a significative innovation within a minimally invasive surgery approach. A variety of robotic platforms have been made available throughout the years, and the outcomes related to those platforms have been described in the literature for many types of surgeries. Medtronic's HugoTM RAS system is one of the newest robotic generations launched, but because of its recent placing on the field, comprehensive clinical data are still lacking. The aim of the present state of the art is to address the current literature concerning the use of the HugoTM RAS robot in order to report its feasibility, safety and clinical applications in different surgical branches. Two reviewers independently conducted a search on the "PubMed" electronic database, using the keywords "Hugo" and "Hugo RAS". After the initial screening of 35 results, a total of 15 articles concerning the Hugo RAS system were selected for the review, including both oncological and benign surgery. Patients' demographic and baseline data were compared including, when available, docking system times, complications and oncological outcomes in the fields of urologic, gynecologic and general surgery. With reference to urological procedures, a total of 156 robot-assisted radical prostatectomies, 10 robot-assisted partial nephrectomies, and 5 robot-assisted adrenalectomies were performed, involving a total of 171 patients. The surgical branch in which the Hugo system found its major application was urology, which was followed by gynecology and general surgery. The Hugo RAS system by Medtronic represents an innovative and safe surgical platform, with excellent perspective for the future and different clinical applications in many surgical branches. More studies are needed to validate the safety and results from this new robotic platform.

5.
J Pers Med ; 13(9)2023 Sep 13.
Artigo em Inglês | MEDLINE | ID: mdl-37763140

RESUMO

The current literature relating to the novel HugoTM RAS System lacks consistent data concerning the bedside features of robot-assisted partial nephrectomy (RAPN). To describe the trocar placement and docking settings for RAPN with a three-arm configuration to streamline the procedure with HugoTM RAS, between October 2022 and April 2023, twenty-five consecutive off-clamp RAPNs for renal tumors with the HugoTM RAS System were performed. We conceived a trouble-free three-arm setting to ease and standardize RAPN trocar placement and docking settings with HugoTM RAS. Perioperative data were collected. Post-operative complications were reported according to the Clavien-Dindo classification. The eGFR was calculated according to the CKD-EPI formula. Continuous variables were presented as the median and IQR, while frequencies were reported as categorical variables. Off-clamp RAPNs were successfully performed in all cases without the need for conversion or additional port placement. The median age and BMI were 69 years (IQR, 60-73) and 27.3 kg/m2 (IQR, 25.7-28.1), respectively. The median tumor size and R.E.N.A.L. score were 32.5 mm (IQR, 26-43.7) and 6 (IQR, 5-7), respectively. Two patients were affected by cT2 renal tumors. The median docking and console time were 5 (IQR, 5-6) and 90 min (IQR, 68-135.75 min), respectively, with slightly progressive improvements in the docking time achieved. No intraoperative complications occurred alongside clashes between instruments or with the bed assistant. In experienced hands, this simplified three-instrument configuration of the HugoTM RAS System for off-clamp RAPN resulted in feasible and safe practice, providing patient-tailored trocar placement and docking with non-inferior peri-perioperative outcomes to other robotic platforms.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA