RESUMO
OBJECTIVES: Endoscopic retrograde cholangiopancreatography (ERCP) represents the gold standard for jaundice palliation in patients with distal malignant biliary obstruction (DMBO). Biliary drainage using electrocautery lumen apposing metal stent (EC-LAMS) is currently a well-established procedure when ERCP fails. In a palliative setting the endoscopic ultrasound-guided gallbladder drainage (EUS-GBD) could represent an easy and valid option. We performed a prospective study with a new EC-LAMS with the primary aim to assess the clinical success rate of EUS-GBD as a first-line approach to the palliation of DMBO. METHODS: In all, 37 consecutive patients undergoing EUS-GBD with a new EC-LAMS were prospectively enrolled. Clinical success was defined as bilirubin level decrease >15% within 24 h and >50% within 14 days after EC-LAMS placement. RESULTS: The mean age was 73.5 ± 10.8 years; there were 17 male patients (45.9%). EC-LAMS placement was technically feasible in all patients (100%) and the clinical success rate was 100%. Four patients (10.8%) experienced adverse events, one bleeding, one food impaction, and two cystic duct obstructions because of disease progression. No stent-related deaths were observed. The mean hospitalization was 7.7 ± 3.4 days. Median overall survival was 4 months (95% confidence interval 1-8). CONCLUSION: Endoscopic ultrasound-guided gallbladder drainage with the new EC-LAMS is a valid option in palliative endoscopic biliary drainage as a first-step approach in low survival patients with malignant jaundice unfit for surgery. A smaller diameter EC-LAMS should be preferred, particularly if the drainage is performed through the stomach, to avoid potential food impaction, which could result in stent dysfunction.
Assuntos
Colestase , Icterícia , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Vesícula Biliar , Estudos Prospectivos , Colestase/diagnóstico por imagem , Colestase/etiologia , Colestase/cirurgia , Endossonografia/métodos , Icterícia/complicações , Drenagem/métodos , Stents/efeitos adversos , Colangiopancreatografia Retrógrada Endoscópica/métodos , Ultrassonografia de Intervenção/métodosRESUMO
Mediastinal collection secondary to necrotic acute pancreatitis, is an extremely rare event caused by the posterior rupture of the pancreatic duct into the retroperitoneal space with the penetration of the pancreatic fluid through the diaphragmatic orifices. Infection of the necrotic collection may occur with a consequent substantial increase of the mortality rate. Due to the rarity of this severe condition, no consensus is known about the management of infected mediastinal necrotic collections. We reported the case of a 61-year-old male who was critically unwell secondary to a large mediastinal necrotic collections after necrotic acute pancreatitis with no improvement after surgery. The patient was successfully treated by EUS-guided trans-esophageal drainage using the AXIOS Electrocautery Enhanced Delivery System™. This procedure proved in this case to be a safe and effective option for the management of infected necrotic mediastinal collections.
Assuntos
Drenagem/instrumentação , Eletrocoagulação/instrumentação , Endossonografia , Pancreatite Necrosante Aguda/terapia , Ultrassonografia de Intervenção , Drenagem/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Suco Pancreático , Pancreatite Necrosante Aguda/diagnóstico por imagem , Stents Metálicos Autoexpansíveis , Tomografia Computadorizada por Raios XRESUMO
Adequate biliary drainage with endoscopic or percutaneous placement of self-expandable metal stents represents the goal of palliation in patients with inoperable malignant obstruction of the biliary tree. As an adjunct to stenting, various tissue ablation treatments have been proposed with conflicting results. The aim of this study was to test the effect on biliary tissue of a new ablation technique based on Nd:YAG laser light delivery. The study was conducted on ex vivo specimens of 18 healthy farm pigs, using cystic ducts that are the simplest biliary structures to isolate and cannulate ex vivo. A 22G cannula was positioned into the cystic duct and a quartz optical fibre, with a prototypal cooling system, was inserted into the cannula. Nd:YAG laser output powers of 10, 12, and 15 W were tested, with a total delivered energy of 1000 J in continuous mode in each case. After laser treatment, histological analysis was performed. At macroscopical examination, no lesions of the external wall of the cystic ducts were detected. At histopathological examination, a coagulative necrosis involving the entire mucosa up to the muscolaris propria without significant changes of periductal tissues was observed in all specimens. This study shows the possibility of using Nd:YAG laser on ex vivo porcine biliary ducts with the effect of obtaining a coagulative necrosis involving the whole mucosa.
Assuntos
Angioplastia , Ductos Biliares/efeitos da radiação , Lasers de Estado Sólido , Animais , Doenças dos Ductos Biliares/cirurgia , Ductos Biliares/patologia , Ductos Biliares/cirurgia , Ducto Cístico/cirurgia , Feminino , Humanos , Fotocoagulação a Laser , Necrose , Sus scrofa , TemperaturaRESUMO
BACKGROUND: Laser ablation (LA) with a neodymium-doped yttrium aluminum garnet (Nd:YAG) laser is a minimally invasive approach able to achieve a high rate of complete tissue necrosis. In a previous study we described the feasibility of EUS-guided Nd:YAG pancreas LA performed in vivo in a porcine model. OBJECTIVE: To establish the best laser setting of Nd:YAG lasers for pancreatic tissue ablation. A secondary aim was to investigate the prediction capability of a mathematical model on ablation volume. DESIGN: Ex vivo animal study. SETTING: Hospital animal laboratory. SUBJECTS: Explanted pancreatic glands from 60 healthy farm pigs. INTERVENTION: Laser output powers (OP) of 1.5, 3, 6, 10, 15, and 20 W were supplied. Ten trials for each OP were performed under US guidance on ex vivo healthy porcine pancreatic tissue. MAIN OUTCOME MEASUREMENTS: Ablation volume (Va) and central carbonization volume (Vc) were measured on histologic specimens as the sum of the lesion areas multiplied by the thickness of each slide. The theoretical model of the laser-tissue interaction was based on the Pennes equation. RESULTS: A circumscribed ablation zone was observed in all histologic specimens. Va values grow with the increase of the OP up to 10 W and reach a plateau between 10 and 20 W. The trend of Vc values rises constantly until 20 W. The theoretical model shows a good agreement with experimental Va and Vc for OP between 1.5 and 10 W. LIMITATIONS: Ex vivo study. CONCLUSION: Volumes recorded suggest that the best laser OP could be the lowest one to obtain similar Va with smaller Vc in order to avoid the risk of thermal injury to the surrounding tissue. The good agreement between the two models demonstrates the prediction capability of the theoretical model on laser-induced ablation volume in an ex vivo animal model and supports its potential use for estimating the ablation size at different laser OPs.
Assuntos
Terapia a Laser/métodos , Lasers de Estado Sólido , Pâncreas/cirurgia , Alumínio , Animais , Modelos Animais , Neodímio , Cirurgia Assistida por Computador/métodos , Suínos , Ultrassonografia de Intervenção/métodos , ÍtrioRESUMO
Background and study aims Endoscopic retrograde cholangiopancreatography (ERCP) represents the gold standard for jaundice palliation in malignant biliary obstruction (MBO) patients. Biliary drainage using electrocautery lumen apposing metal stent (EC-LAMS) is currently a well-established procedure when ERCP fails. We aimed to assess the technical and clinical success of a new EC-LAMS as the first approach to the palliation of malignant jaundice due to MBO in patients unfit for surgery. Patients and methods Twenty-five consecutive patients undergoing endoscopic-guided biliary drainage with the new EC-LAMS were prospectively enrolled. Clinical success was defined as bilirubin level decrease >â15â% 24 hours after EC-LAMS placement. Results Mean age was 76.6â±â11.56 years, and male patients were 10 (40â%). EC-LAMS placement was technically feasible in 24 patients (96â%) and clinical success rate was 100â%. Only one patient (4â%) experienced a misplacement rescued by an immediate second EC-LAMS placement. The mean duration of hospital stay was 4.66â±â4.22 days. The median overall survival was 7 months (95â% CI 1-7). Conclusions In this preliminary study, the new EC-LAMS seems to allow a single-step palliative endoscopic therapy in patients affected by jaundice due to MBO, with high technical and clinical success and low adverse events. Further large prospective studies are warranted to validate these results.
RESUMO
BACKGROUND: Laser ablation with a neodymium:yttrium aluminum garnet (Nd:YAG) laser can achieve a high rate of complete tissue necrosis and has been applied as a minimally invasive, palliative option in hepatocellular carcinoma, liver metastasis in colorectal cancer, and malignant thyroid nodules. OBJECTIVE: To assess the in vivo feasibility of EUS-guided laser ablation with an Nd:YAG laser of normal pancreatic tissue of a porcine model. DESIGN: Prospective investigation. SETTING: Hospital animal laboratory. SUBJECTS: Eight pigs. INTERVENTIONS: EUS-guided puncture of the pancreatic tail with a laser-beam fiber. An Nd:YAG laser (1.064 nm) was used, with an output power of 2 and 3 W and a total delivered energy of 500 and 1000 J in continuous mode. MAIN OUTCOME MEASUREMENTS: The 24-hour follow-up of the pigs was focused on clinical and laboratory aspects. Results of histological studies of the pancreas were obtained 24 hours after the procedure on necroscopy tissue. RESULTS: There were no technical limitations to the performance of the procedure. Tissue necrosis, localized in the pancreatic parenchyma, was observed in all animals on histological examination. The volume of ablation tissue ranged from a mean of 314 mm(3) to 483 mm(3). The ablation area ranged from a mean of 49 mm(2) to 80 mm(2). No major postprocedure complications were recorded, and all the pigs survived at 24 hours. LIMITATION: Animal study. CONCLUSIONS: EUS-guided laser ablation of the pancreas with an Nd:YAG laser is feasible in a porcine model.
Assuntos
Endossonografia/métodos , Terapia a Laser/métodos , Lasers de Estado Sólido/uso terapêutico , Pâncreas/cirurgia , Animais , Modelos Animais de Doenças , Estudos de Viabilidade , Seguimentos , Imageamento Tridimensional , Pâncreas/diagnóstico por imagem , Projetos Piloto , Estudos Prospectivos , SuínosRESUMO
Metronidazole-induced encephalopathy (MIE) is a rare and often under-recognized iatrogenic condition. The diagnosis should be considered in metronidazole-treated patients presenting with acute encephalopathy, unprovoked seizures and cerebellar signs. While typical magnetic resonance imaging (MRI) findings strongly support the diagnosis, electroencephalography (EEG) features have been rarely reported and poorly described. We present a longitudinal EEG assessment in one patient with encephalopathy due to metronidazole toxicity who presented a peculiar EEG pattern presentation and evolution. During the acute phase of encephalopathy, the EEG showed a monomorphic, sharply contoured theta activity symmetrically represented over frontal regions with an anterior-posterior progression which evolved in parallel with clinical worsening. Together with a systematic review of the literature, we discuss whether this EEG activity may represent a distinct neurophysiological correlate of 'cerebellar encephalopathy'.
RESUMO
BACKGROUND AND AIM: Endoscopic full-thickness resection (EFTR) provides complete en-bloc resection with a histopathological evaluation of submucosal, muscular, and serosal layers. The aim of this study was to investigate the efficacy and safety of a novel over-the-scope device for colorectal EFTR. MATERIAL AND METHODS: In this retrospective, observational, open-label case study, a total of 20 patients with superficial colorectal neoplasms, underwent EFTR using a new endoscopic full-thickness resection device (FTRD; Ovesco Endoscopy, Tübingen, Germany). Endoscopic treatment outcomes (technical success, rate of EFTR, adverse events) and early follow-up at three months, were analyzed. RESULTS: We reported a 100% of technical success, defined as full-thickness resection. Among the R1 resections, histology was negative for neoplasm. Non-lifting adenomas had histology positive for adenocarcinoma: seven T1/G1/sm1; one T1/G1/sm2; one, who underwent a surgical resection, T1/G1/sm3. Mean size of the resected lesions was 26mm, ranging from 10 to 42mm. One (5%) patient developed abdominal pain, fever and leukocytosis and was treated conservatively with medical therapy. In all specimens, histological complete resection was confirmed. CONCLUSIONS: EFTR is a feasible and effective technique that could become a valid alternative to EMR and ESD in the management of recurrent adenomas, no-lifting lesions and scars of R1 resections. However, prospective studies are needed to further evaluate the device and technique.