Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 32
Filtrar
1.
J Arthroplasty ; 2024 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-38823519

RESUMO

INTRODUCTION: The reconstruction of acetabular defects in total hip arthroplasty (THA) can be challenging. An option to treat uncontained acetabular defects is to use modular tantalum augments in combination with cementless press-fit cups. However, modularity is associated with an increased risk of debonding and mechanical failure. In addition, metal wear particles can be released due to micromotions at the implant interface. Clinical data on the long-term results of this treatment strategy is limited. The purposes of this study were: (1) to evaluate the clinical and radiological outcome of complex THA using modular trabecular metal augments and uncemented revision cups; (2) to investigate the blood tantalum concentrations in these patients at mid-term (mean 4.5 year) follow-up; and (3) to report complications and mechanisms of failure related to this procedure. MATERIALS AND METHODS: In this single-center study, we retrospectively reviewed data from a consecutive cohort of 27 patients who underwent complex acetabular defect reconstruction using a modular tantalum acetabular augment in combination with an uncemented tantalum cup. We evaluated the implant survival, and the radiological and clinical outcomes after a mean follow-up of 4.5 years (SD 2.1; range 2.5 to 10.6 years) using patient-reported outcome scores (PROMs). Blood samples were analyzed regarding tantalum concentration and compared with a control group. RESULTS: The cumulative survival rate at 4.5 years with the endpoint "revision of the acetabular component for aseptic loosening" was 94.4% (95% confidence interval (CI) 71.6 to 99.2) and 82.9% (95 % CI 60.5 to 93.3) for the endpoint "revision for any reason." The PROMs improved significantly up to the latest follow-up, and radiographic data showed no signs of loosening or implant migration. Median blood tantalum concentrations were significantly higher in the study group (0.15 µg/L) compared to the control group (0.002 µg/L) (P < 0.001). CONCLUSIONS: This study demonstrated acceptable clinical and radiological results of cementless revision THA using modular trabecular metal implants for the reconstruction of large acetabular defects. Tantalum concentrations were significantly higher in patients who had tantalum implants compared to the control group, however, the systemic and local effects of an increased tantalum exposure are not yet fully understood and have to be further investigated.

2.
Arch Orthop Trauma Surg ; 144(3): 1369-1377, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37872437

RESUMO

INTRODUCTION: Modular femoral components allow for patient-specific restoration of hip joint geometry and the reconstruction of extensive bone defects in revision total hip arthroplasty (THA); however, potential problems of modular implants such as taper corrosion and the risk of implant fracture continue to be of concern. The aim of the present study was to evaluate the clinical and radiological results of a cementless modular revision stem following revision surgery due to aseptic loosening and periprosthetic fracture and to assess patient-reported outcome measures (PROMs) in these patients at mid-term follow-up. MATERIALS AND METHODS: In this study, a consecutive cohort of 75 patients who underwent primary revision THA at our institution using a modular cementless stem design (MRP-TITAN stem) was retrospectively evaluated at a mean follow-up of 7.7 years. Kaplan-Meier survivorship analyses were performed with revision of the femoral component for any reason as the end point. The Harris-Hip Score, the UCLA Activity Score, the Forgotten Joint Score and the SF-12 Score were used for clinical assessment. We used the Wilcoxon signed rank test to compare pre- and postoperative clinical scores. RESULTS: Overall stem survival with the endpoint stem re-revision for any reason was 85.4% at a mean follow-up of 7.7 years (range 2.4-14 years). Stem survival was 89.5% in the aseptic loosening group and 78.3% in the periprosthetic fracture group with no statistically significant difference between both groups (p = 0.107). One patient had to be revised due to taper fracture. PROMs improved significantly up to the latest follow-up, and radiographic evaluation showed full osseointegration of all stems in this cohort. CONCLUSIONS: Revision THA using a modular cementless titanium revision stem demonstrated adequate clinical and radiological results at mid- to long-term follow-up in this cohort. Cementless revision stems are a useful treatment option to restore the anatomy, especially in deformed hips and in complex revision hip arthroplasty. However, there are some significant disadvantages related to an increased risk of mechanical failure such as corrosion/fretting damage and implant fracture. Future high-quality prospective studies with longer follow-up are necessary to confirm the supposed advantages.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Fraturas Periprotéticas , Humanos , Artroplastia de Quadril/efeitos adversos , Seguimentos , Fraturas Periprotéticas/diagnóstico por imagem , Fraturas Periprotéticas/cirurgia , Fraturas Periprotéticas/etiologia , Estudos Retrospectivos , Estudos Prospectivos , Desenho de Prótese , Reoperação , Falha de Prótese , Resultado do Tratamento
3.
Knee Surg Sports Traumatol Arthrosc ; 31(9): 3947-3955, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37093235

RESUMO

PURPOSE: Due to low incidence of isolated lateral osteoarthritis (OA), there are limited data on whether a fixed-bearing (FB) or a mobile-bearing (MB) design is superior for lateral unicompartmental knee replacement (UKR). The aim of this matched-pairs analysis was to compare both designs in terms of implant survival and clinical outcome. METHODS: Patients who received MB-UKR (Group A) and FB-UKR (Group B) at a single centre were matched according to gender, age at time of surgery and body mass index (BMI). Survivorship analysis was performed with the endpoint set as "revision for any reason". Clinical outcome was assessed using the Oxford knee score (OKS), visual analogue scale for pain (VAS), patients' satisfaction, University of California Los Angeles activity scale (UCLA) and the Tegner activity score (TAS). RESULTS: A total of 60 matched pairs were included with a mean follow-up (FU) of 3.4 ± 1.3 (range 1.2-5.0) years in Group A and 2.7 ± 1.2 (range 1.0-5.0) years in Group B. Survivorship between both groups differed significantly (Group A: 78.7%; Group B: 98.3%, p = 0.003) with bearing dislocation being the most common reason for revision in Group A (46.2%). The relative and absolute risk reduction were 92.2% and 20%, respectively, with 5 being the number needed to treat. There were no differences in OKS (Group A: 41.6 ± 6.5; Group B: 40.4 ± 7.7), VAS (Group A: 2.9 ± 3.2; Group B: 1.6 ± 2.2), UCLA (Group A: 5.7 ± 1.3; Group B: 5.9 ± 1.8) and TAS (Group A: 3.0 ± 1.0; Group B: 3.1 ± 1.2) between both groups on follow-up. CONCLUSION: Despite modern prosthesis design and surgical technique, implant survival of lateral MB-UKR is lower than that of FB-UKR on the short- to mid-term due to bearing dislocation as the most common cause of failure. Since clinical results are equivalent in both groups, FB-UKR should be preferred in treatment of isolated lateral OA. LEVEL OF EVIDENCE: Retrospective case-control study, Level III.


Assuntos
Artroplastia do Joelho , Luxações Articulares , Prótese do Joelho , Osteoartrite do Joelho , Humanos , Artroplastia do Joelho/métodos , Estudos Retrospectivos , Estudos de Casos e Controles , Osteoartrite do Joelho/cirurgia , Osteoartrite do Joelho/etiologia , Reoperação , Desenho de Prótese , Luxações Articulares/cirurgia , Dor/cirurgia , Resultado do Tratamento , Articulação do Joelho/cirurgia
4.
Arch Orthop Trauma Surg ; 143(9): 5849-5856, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36917240

RESUMO

INTRODUCTION: The aim of the current study was to demonstrate short- to mid-term survivorship as well as clinical outcome of lateral unicompartmental knee replacement (UKR) with a fixed-bearing (FB) design from a non-designer center using the Oxford Fixed Lateral prosthesis. MATERIALS AND METHODS: This single-center retrospective cohort study reports the results of 133 consecutive lateral FB-UKR. Survivorship analysis was performed with different endpoints and clinical outcome was measured using the Oxford-Knee-Score (OKS), American-Knee-Society-Score (AKSS-O), range-of-motion (ROM) and visual-analog-scale for pain (VAS). RESULTS: There were two revision surgeries with conversion to total knee replacements (TKR) due to persistent pain resulting in a survival rate of 98.5% (95% CI 93.5-99.6) with a mean follow-up (FU) of 3.3 ± 1.8 years (range 1-8.5). All outcome scores, VAS and ROM showed a significant improvement at final FU (p < 0.001). The OKS improved from 26 ± 7.8 (range 11-45) preoperatively to 39 ± 8.3 (range 13-48), the AKSS-O from 49.2 ± 14.6 (range 18-90) to 81.8 ± 15.1 (range 40-100), the AKSS-F from 53 ± 23.7 (range 0-100) to 80.4 ± 21.4 (range 5-100) and the ROM from 118 ± 17 (range 90-160) to 134 ± 9.5 (range 100-155). CONCLUSIONS: The short- to mid-term results following lateral FB-UKR demonstrate a high survivorship and good clinical outcome from an independent series. We, therefore, suggest that FB-UKR is a safe treatment option for isolated lateral OA if sufficient surgical experience is provided. LEVEL OF EVIDENCE: Retrospective cohort study, level IV.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho , Humanos , Artroplastia do Joelho/métodos , Estudos Retrospectivos , Osteoartrite do Joelho/cirurgia , Resultado do Tratamento , Reoperação , Dor/cirurgia , Articulação do Joelho/cirurgia , Seguimentos
5.
Arch Orthop Trauma Surg ; 143(6): 3077-3084, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35849185

RESUMO

INTRODUCTION: The aim of the present study was to assess clinical outcome and mid-term survivorship of mobile-bearing unicompartmental knee arthroplasty in patients 50 years of age or younger. METHODS: This study reports the results of 119 patients (130 knees) following mobile-bearing medial UKA. Primary indication was advanced osteoarthritis or avascular necrosis of the femoral condyle. The anterior cruciate ligament (ACL) as well as the collateral ligaments were functionally intact, the varus deformity was manually correctable and there was no evidence of osteoarthritis in the lateral compartment. Survivorship analysis was performed with different endpoints and clinical outcome was measured using the Oxford Knee Score (OKS), American Knee Society Score and Functional Score (AKSS-O, AKSS-F), range of motion (ROM), Tegner activity score, University of California Los Angeles score (UCLA) and visual analogue scale for pain (VAS). RESULTS: The survival rate was 96.6% at 6.5 years (95% CI 98.7-91.3%; number at risk: 56) and 91.7% (95% CI 96.7-80%; number at risk: 22) at 10 years for the endpoint device related revisions and 91.5% at 6.5 years (95% CI 95.4-84.5%; number at risk: 56) and 86.8% (95% CI 93-76.2%; number at risk: 22) at 10 years for the endpoint revision for any reason. Outcome scores, VAS and ROM showed significant improvements (p < 0.001). The mean OKS increased from 26.7 (standard deviation (sd): 7.2) preoperatively to 40.9 (sd: 7.6) at final follow-up, the mean AKSS-O from 48.3 (sd: 13.3) to 87.8 (sd: 14.4) and the mean ROM from 118° (sd: 16.7) to 125° (sd: 11.4). The radiological analysis revealed progression of degenerative changes in the lateral compartment in 39.6% of patients without affecting the functional outcome. CONCLUSIONS: Medial mobile-bearing UKA is a viable surgical treatment option in young patients with significant improvements in knee function and pain. Further follow-up is necessary to evaluate the long-term efficacy. LEVEL OF EVIDENCE: Retrospective cohort study, Level III.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho , Humanos , Artroplastia do Joelho/efeitos adversos , Prótese do Joelho/efeitos adversos , Estudos Retrospectivos , Resultado do Tratamento , Articulação do Joelho/cirurgia , Dor/etiologia , Seguimentos
6.
Acta Orthop ; 94: 321-327, 2023 07 04.
Artigo em Inglês | MEDLINE | ID: mdl-37409417

RESUMO

PURPOSE: We aimed to determine the minimum 20-year survival rates of a cementless press-fit cup in young patients. PATIENTS AND METHODS: This is a retrospective, single-center, multi-surgeon cohort study investigating the minimum 20-year clinical and radiological outcome of the first 121 consecutive total hip replacements (THRs) using a cementless, press-fit cup (Allofit, Zimmer, Warsaw, IN, USA) performed between 1999 and 2001. 28-mm metal-on-metal (MoM) and ceramic-on-conventionally not highly crosslinked polyethylene (CoP) bearings were used in 71% and 28%, respectively. Median patient age at surgery was 52 (range 21-60) years. Kaplan-Meier survival analysis was conducted for different endpoints. RESULTS: The 22-year survival rate for the endpoint aseptic cup or inlay revision was 94% (95% confidence interval [CI] 87-96) and 99% (CI 94-100) for aseptic cup loosening. 20 patients (21 THRs; 17%) had died and 5 (5 THRs; 4%) were lost to follow-up. No THR showed evidence of radiographic cup loosening. Osteolysis was observed in 40% of THRs with MoM and 77% with CoP bearings. 88% of THRs with CoP bearings showed significant polyethylene wear. CONCLUSION: The investigated cementless press-fit cup, which is still in clinical use today, showed excellent long-term survival rates in patients under the age of 60 years at surgery. However, osteolysis due to polyethylene and metal wear was frequently observed and is a matter of concern in the third decade after surgery.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Osteólise , Humanos , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Artroplastia de Quadril/efeitos adversos , Prótese de Quadril/efeitos adversos , Seguimentos , Estudos Retrospectivos , Estudos de Coortes , Falha de Prótese , Metais , Polietileno , Desenho de Prótese , Reoperação
7.
J Shoulder Elbow Surg ; 28(3): 539-546, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30518478

RESUMO

BACKGROUND: Products from metal wear have been identified as a potential cause of adverse local tissue reactions and implant failure in total hip arthroplasty. However, the role of metal ion exposure in patients after total shoulder replacement is unclear. The objective of the present study was to determine in vivo blood metal ion levels of cobalt, chromium, and titanium in patients after anatomic total shoulder arthroplasty (TSA) or reverse TSA. METHODS: A consecutive series of patients after anatomic TSA or reverse TSA was evaluated retrospectively. After exclusion of patients with additional metal implants, 40 patients with unilateral anatomic TSA (n = 20) or reverse TSA (n = 20) were available for whole-blood metal ion analysis at a mean follow-up of 28 ± 9.6 months. Twenty-three healthy individuals without metal implants served as a control group. RESULTS: Mean cobalt ion concentrations were 0.18 µg/L (range, 0.1-0.66 µg/L), 0.15 µg/L (range, 0.03-0.48 µg/L), and 0.11 µg/L (range, 0.03-0.19 µg/L), mean chromium ion levels were 0.48 µg/L (range, 0.17-2.41 µg/L), 0.31 µg/L (range, 0.09-1.26 µg/L), and 0.14 µg/L (range, 0.04-0.99 µg/L), and mean titanium ion concentrations were 1.31 µg/L (range, 0.75-4.52 µg/L), 0.84 µg/L (range, 0.1-1.64 µg/L), and 0.62 µg/L (range, 0.32-2.14 µg/L) in the reverse TSA group, the anatomic TSA group, and the control group, respectively. CONCLUSIONS: TSA resulted in elevated metal ion levels compared with healthy controls, although overall metal ion concentrations measured in this study were relatively low. The role of local metal ion exposure in patients with total shoulder replacements should be further investigated.


Assuntos
Artroplastia do Ombro/instrumentação , Cromo/sangue , Cobalto/sangue , Prótese de Ombro , Titânio/sangue , Idoso , Idoso de 80 Anos ou mais , Artroplastia do Ombro/métodos , Estudos de Casos e Controles , Estudos Transversais , Feminino , Seguimentos , Humanos , Íons/sangue , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Estudos Retrospectivos , Prótese de Ombro/efeitos adversos
8.
BMC Musculoskelet Disord ; 19(1): 18, 2018 01 17.
Artigo em Inglês | MEDLINE | ID: mdl-29343231

RESUMO

BACKGROUND: Physical activity and regular participation in recreational sports gain importance in patients' lifestyle after knee arthroplasty. Cementless unicompartimental Knee replacement with the Oxford System has been introduced into clinical routine. Currently there is no data reporting on the physical activity, return to sports rate and quality of live after medial cementless Oxford Unicompartimental Knee Replacement (OUKR). METHODS: This retrospective cohort study reports on the functional outcome of the first 27 consecutive patients (30 knees) that were consecutively treated with a cementless medial OUKR between 2007 and 2009 in our hospital. Physical activity and quality of life were measured using the Tegner-Score, the UCLA-Activity Score, the Schulthess Clinical Activity Questionnaire and the SF-36 Score. The patients' satisfaction with the outcome was measured using a visual analogue scale. RESULTS: Mean age at surgery was 62.5 years. Patients showed a rapid recovery with 17 out of 27 patients returning to sports within 3 months, 24 within 6 months after surgery. The Return-to-activity-rate was 100%. 10 out of 27 patients showed a high activity level (UCLA ≥7 points) with a mean postoperative UCLA-Score of 6.1 points. CONCLUSIONS: Patients recover rapidly after cementless OUKR with a return to sports rate of 100% and patients are able to participate in high impact sports disciplines.


Assuntos
Atividades Cotidianas , Artroplastia do Joelho/métodos , Exercício Físico/fisiologia , Recuperação de Função Fisiológica/fisiologia , Atividades Cotidianas/psicologia , Idoso , Artroplastia do Joelho/psicologia , Cimentos Ósseos , Estudos de Coortes , Exercício Físico/psicologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Tempo
9.
Arch Orthop Trauma Surg ; 137(7): 1011-1017, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28439705

RESUMO

PURPOSE: Cemented unicompartmental knee replacement (UKR) has proven excellent long-term survival rates and functional scores in Price et al. (Clin Orthop Relat Res 435:171-180, 2005), Price and Svard (Clin Orthop Relat Res 469(1):174-179, 2011) and Murray et al. (Bone Joint Surg Br 80(6):983-989, 1998). The main causes for revision, aseptic loosening and pain of unknown origin might be addressed by cementless UKR in Liddle et al. (Bone Joint J 95-B(2):181-187, 2013), Pandit et al. (J Bone Joint Surg Am 95(15):1365-1372, 2013), National Joint Registry for England, Wales and Northern Ireland: 10th Annual Report 2013 ( http://www.njrcentre.org.uk/njrcentre/Portals/0/Documents/England/Reports/10th_annual_report/NJR%2010th%20Annual%20Report%202013%20B.pdf , 2013), Swedish Knee Arthroplasty Register: Annual Report 2013 ( http://www.myknee.se/pdf/SKAR2013_Eng.pdf , 2013). METHODS: This single-centre retrospective cohort study reports the 5-year follow-up results of our first 30 consecutively implanted cementless Oxford UKR (OUKR). Clinical outcome was measured using the OKS, AKSS, range of movement and level of pain (visual analogue scale). The results were compared to cemented OUKR in a matched-pair analysis. RESULTS: Implant survival was 89.7%. One revision each was performed due to tibial fracture, progression of osteoarthritis (OA) and inlay dislocation. The 5-year survival rate of the cementless group was 89.7% and of the cemented group 94.1%. Both groups showed excellent postoperative clinical scores. CONCLUSIONS: Cementless fixation shows good survival rates and clinical outcome compared to cemented fixation.


Assuntos
Prótese do Joelho , Osteoartrite do Joelho/cirurgia , Desenho de Prótese , Idoso , Artroplastia do Joelho/métodos , Cimentos Ósseos , Estudos de Coortes , Feminino , Seguimentos , Alemanha , Humanos , Masculino , Medição da Dor , Dor Pós-Operatória , Sistema de Registros , Estudos Retrospectivos
10.
J Arthroplasty ; 30(2): 249-53, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25445853

RESUMO

Aseptic loosening and focal osteolysis are the most common reasons for knee arthroplasty failure. The best treatment remains unclear. We reviewed the literature on the treatment of revision knee arthroplasty using bony structural allografts (476 cases) and porous metal cones (223 cases) to determine if a difference in the revision failure rates was discernable. The failure rates were compared using a logistic regression model with adjustment for discrepancies in FU time and number of grafts used (femoral, tibial, or both). In this analysis, the porous implant shows a significantly decreased loosening rate in AORI 2 and 3 defects. The overall failure rate was also substantially lower in the porous metal group than the structural allograft group; little difference in the infection rates was noted.


Assuntos
Artroplastia do Joelho , Osteólise/cirurgia , Materiais Biocompatíveis , Transplante Ósseo , Humanos , Prótese do Joelho , Metais , Desenho de Prótese , Falha de Prótese , Reoperação , Transplante Homólogo
11.
J Clin Med ; 12(4)2023 Feb 20.
Artigo em Inglês | MEDLINE | ID: mdl-36836231

RESUMO

The number of unicompartmental knee replacements (UKR) is increasing. Alongside various advantages, the revision rate of cemented UKR is higher compared to total knee arthroplasty (TKR). In contrast, cementless fixation shows reduced revision rates, compared to the cemented UKR. However, most of the recent literature is based on designer-dependent studies. In this retrospective, single-center cohort study, we investigated patients who underwent cementless Oxford UKR (OUKR) between 2012 and 2016 in our hospital with a minimum follow-up of five years. Clinical outcome was evaluated using the OKS, AKSS-O, AKSS-F, FFbH-OA, UCLA, SF-36, EQ-5D-3L, FJS, ROM, pain, and satisfaction measures. Survival analysis was performed with reoperation and revision as endpoints. We included 201 patients (216 knees) for clinical evaluation. All outcome parameters increased significantly from pre- to postoperative stages. The five-year survival rate was 96.1% for revision surgery and 94.9% for reoperation. The main reasons for revision were the progression of osteoarthritis, inlay dislocation, and tibial overstuffing. Two iatrogenic tibial fractures appeared. Cementless OUKR shows excellent clinical outcome and high survival rates after five years. The tibial plateau fracture in cementless UKR represents a serious complication and requires modification of the surgical technique.

12.
J Clin Med ; 12(16)2023 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-37629462

RESUMO

Knee range of motion and patient-reported outcome measures (PROMs) are often used as screening tools to assess the severity of knee osteoarthritis and guide the decision to refer patients to an arthroplasty clinic. However, there is little understanding regarding the correlation between these factors. Thus, the purpose of this study was to determine the correlation between patient-reported clinical function measured with the Oxford Knee Score (OKS), pain assessed using the visual analog scale (VAS), knee range of motion (ROM), and characteristic radiographic features in patients with advanced osteoarthritis of the knee. A prospective analysis of a consecutive series of 138 patients with advanced unilateral osteoarthritis (OA) of the knee was performed. The severity of radiographic OA was classified according to the most commonly used Kellgren and Lawrence classification (K&L). Spearman's rank correlation analysis and multiple linear regression analysis were performed. The OKS was used as a dependent variable and was adjusted for pain, ROM, and nine standardized radiographic parameters on multiple views of the tibiofemoral and patellofemoral joint. OKS and pain correlated weakly with the K&L grade (r = -0.289; p = 0.001; r = 0.258; p = 0.002). K&L grade and the degree of patellofemoral joint space narrowing were identified as independent factors being associated with a poorer OKS (coefficient -4.528, p = 0.021; coefficient -2.211, p = 0.038). Slightly worse results were identified for OKS and pain in patients with K&L grade 4 osteoarthritis compared to patients with K&L grade 3 osteoarthritis (∆OKS 5.5 points, p < 0.001; ∆VAS 1.7 points, p = 0.003). There was no significant difference for passive range of motion between patients with K&L grade 3 or 4. When counseling patients with advanced knee osteoarthritis who may be eligible for knee arthroplasty, it is essential to give primary consideration to pain levels and self-reported limitations experienced during daily activities. Relying solely on knee ROM and PROMs is not an effective screening method for guiding the decision to refer patients to an arthroplasty clinic.

13.
J Clin Med ; 12(2)2023 Jan 12.
Artigo em Inglês | MEDLINE | ID: mdl-36675564

RESUMO

Unicompartmental knee replacement (UKR) has increased in popularity in recent years, especially in young patients with high demands on their athletic ability. To date, there are no data available on the physical activity of young patients following lateral UKR. The aim of this study was to demonstrate return-to-activity rate and sporting activity of patients aged 60 years or younger following lateral UKR with a fixed-bearing (FB) prosthesis. Thirty-seven patients aged 60 years or younger after lateral FB-UKR were included. Sporting activities were assessed using the University of California Los Angeles activity scale (UCLA) and the Tegner activity score (TAS). Clinical outcome was measured using the Oxford Knee Score (OKS), range of motion (ROM) and visual analogue scale (VAS). The mean follow-up (FU) was 3.1 ± 1.5 years and the mean age at surgery was 52.8 ± 3.1 years. The return-to-activity rate was 87.5% and 49% of patients were highly active postoperatively as defined by an UCLA score of 7 or higher. All clinical parameters increased significantly postoperatively. We demonstrated a high return-to-activity rate with nearly half of the patients achieving high activity levels. Longer FU periods are necessary to evaluate the effect of activity on implant survival.

14.
Stem Cell Res Ther ; 13(1): 168, 2022 04 27.
Artigo em Inglês | MEDLINE | ID: mdl-35477424

RESUMO

BACKGROUND: Fully functional regeneration of skeletal defects by multipotent progenitor cells requires that differentiating cells gain the specific mechano-competence needed in the target tissue. Using cartilage neogenesis as an example, we asked whether proper phenotypic differentiation of mesenchymal stromal cells (MSC) into chondrocytes in vitro will install the adequate biological mechano-competence of native articular chondrocytes (AC). METHODS: The mechano-competence of human MSC- and AC-derived neocartilage was compared during differentiation for up to 35 days. The neocartilage layer was subjected to physiologic dynamic loading in a custom-designed bioreactor and assayed for mechano-sensitive gene and pathway activation, extracellular matrix (ECM) synthesis by radiolabel incorporation, nitric oxide (NO) and prostaglandin E2 (PGE2) production. Input from different pathways was tested by application of agonists or antagonists. RESULTS: MSC and AC formed neocartilage of similar proteoglycan content with a hardness close to native tissue. Mechano-stimulation on day 21 and 35 induced a similar upregulation of mechano-response genes, ERK phosphorylation, NO production and PGE2 release in both groups, indicating an overall similar transduction of external mechanical signals. However, while AC maintained or enhanced proteoglycan synthesis after loading dependent on tissue maturity, ECM synthesis was always significantly disturbed by loading in MSC-derived neocartilage. This was accompanied by significantly higher COX2 and BMP2 background expression, > 100-fold higher PGE2 production and a weaker SOX9 stimulation in response to loading in MSC-derived neocartilage. Anabolic BMP-pathway activity was not rate limiting for ECM synthesis after loading in both groups. However, NFκB activation mimicked the negative loading effects and enhanced PGE2 production while inhibition of catabolic NFκB signaling rescued the load-induced negative effects on ECM synthesis in MSC-derived neocartilage. CONCLUSIONS: MSC-derived chondrocytes showed a higher vulnerability to be disturbed by loading despite proper differentiation and did not acquire an AC-like mechano-competence to cope with the mechanical stress of a physiologic loading protocol. Managing catabolic NFκB influences was one important adaptation to install a mechano-resistance closer to AC-derived neocartilage. This new knowledge asks for a more functional adaptation of MSC chondrogenesis, novel pharmacologic co-treatment strategies for MSC-based clinical cartilage repair strategies and may aid a more rational design of physical rehabilitation therapy after AC- versus MSC-based surgical cartilage intervention.


Assuntos
Cartilagem Articular , Células-Tronco Mesenquimais , Cartilagem Articular/metabolismo , Células Cultivadas , Condrócitos/metabolismo , Humanos , Células-Tronco Mesenquimais/metabolismo , NF-kappa B/metabolismo , Prostaglandinas E/metabolismo , Proteoglicanas/metabolismo
15.
Bone Joint Res ; 11(2): 82-90, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35124977

RESUMO

AIMS: The cemented Oxford unicompartmental knee arthroplasty (OUKA) features two variants: single and twin peg OUKA. The purpose of this study was to assess the stability of both variants in a worst-case scenario of bone defects and suboptimal cementation. METHODS: Single and twin pegs were implanted randomly allocated in 12 pairs of human fresh-frozen femora. We generated 5° bone defects at the posterior condyle. Relative movement was simulated using a servohydraulic pulser, and analyzed at 70°/115° knee flexion. Relative movement was surveyed at seven points of measurement on implant and bone, using an optic system. RESULTS: At the main fixation zone, the twin peg shows less relative movement at 70°/115°. At the transition zone, relative movements are smaller for the single peg for both angles. The single peg shows higher compression at 70° flexion, whereas the twin peg design shows higher compression at 115°. X-displacement is significantly higher for the single peg at 115°. CONCLUSION: Bony defects should be avoided in OUKA. The twin peg shows high resilience against push-out force and should be preferred over the single peg. Cite this article: Bone Joint Res 2022;11(2):82-90.

16.
Knee ; 34: 34-41, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34875496

RESUMO

BACKGROUND: The indications and outcomes of semi- or fully-constrained knee implants in primary total knee arthroplasty (TKA) are still controversially discussed. The present study aims to evaluate the mid-term results and complications of a modular/non-modular rotating-hinge implant in complex primary TKA. METHODS: Eighty-two patients (86 knees) following primary TKA were retrospectively evaluated with a mean follow-up of 63 months. The functional outcome was assessed using the American Knee Society Score (AKSS) and the Oxford Knee Score (OKS). A Visual Analog Scale (VAS) was used to determine pain levels. Implant survival and reoperation rateswere estimated using competing risk analysis. Cox regression analysis wasperformed to evaluate the influence of modularity on implant survival. RESULTS: The survival rate with the endpoint implant revision was 90% (95 %CI:83-98%) and the survival rate with the endpoint all reoperations was 84% (95 %CI:75-94%) at 7 years. The AKSS improved significantly from 24 (SD 14.9, range:0-69) preoperatively to 83 (SD 14.3, range:57-100) postoperatively (p < 0.001); functional AKSS improved significantly from 27 (SD 24.3, range:0-100) to 46 (SD: 32.9, range 0-100) (p = 0.003), and OKS from 19 (SD: 8.3, range:5-43) to 29 (SD: 10.7, range:6-48), respectively (p < 0.0001). VAS decreased significantly from 8 (SD: 2.6, range:0-10) preoperatively to 3 (SD: 2.9, range:0-9) postoperatively (p < 0.0001). There was no significant influence of modularity on revision rates comparing modular to non-modular implants (p = 0.072). CONCLUSIONS: The present rotating-hinge implant provides substantial improvement in function and reduction of pain with good implant survival in the mid-term. Modularity was not associated with higher rates of revision.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Artroplastia do Joelho/efeitos adversos , Artroplastia do Joelho/métodos , Humanos , Articulação do Joelho/cirurgia , Desenho de Prótese , Reoperação , Estudos Retrospectivos , Resultado do Tratamento
17.
Biomedicines ; 10(9)2022 Aug 29.
Artigo em Inglês | MEDLINE | ID: mdl-36140212

RESUMO

Emerging evidence indicates that regulatory T cells (Treg) intervene in the inflammatory processes that drive osteoarthritis (OA). However, whether polarized Tregs affect clinical features of the disease in the short- or long-term, and if so, what their role in OA-related pain and functional disability really is, remains elusive. Thus, the aim of the current study was to characterize the infiltration profile of Tregs in systemic (peripheral blood) and joint-derived (synovial fluid and synovial membrane) samples from patients with knee OA in relation to OA-induced symptoms. To this end, Treg infiltration (CD4+CD25+/high CD127low/-) was analyzed in matched samples of peripheral blood (PB), synovial fluid (SF) and synovial membrane (SM) from a total of 47 patients undergoing elective knee arthroplasty using flow cytometry. At the same time, knee pain and function were assessed and correlated with Treg proportions in different compartments (PB, SF, SM). Interestingly, matched-pair analysis revealed significantly higher Treg proportions in joint-derived samples than in PB, which was mainly attributed to the high Treg frequency in SF. Moreover, we found significant associations between infiltrating Tregs and OA-related symptoms which indicate that lower Treg proportions-especially in the SM-are related to increased pain and functional disability in knee OA. In conclusion, this study highlights the importance of local cellular inflammatory processes in OA pathology. Intra-articular Treg infiltration might play an important role not only in OA pathogenesis but also in the development of OA-related symptoms.

18.
J Knee Surg ; 34(11): 1212-1219, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32268405

RESUMO

Physical activity is essential for overall health. For patients undergoing knee arthroplasty, questions about the implant's suitability for sports arise. The general recommendations for physical activity with knee replacements are often based upon experts' opinions, with a lack of scientific data. This study was performed at an independent high-volume center and aimed to investigate what level of activity patients can achieve and how they perform with a well-functioning cementless unicompartmental knee replacement (UKR). Possible differences in outcome in regards to patients' body mass index (BMI) were also examined. A total of 228 knees treated with cementless Oxford UKR (OUKR) were followed up after a mean of 37.1 months. Tegner's and UCLA (University of California, Los Angeles) scores were obtained to assess the level of physical activity. The Schulthess Clinical Activity Questionnaire was assessed for detailed information on practiced sports, and the SF-36 questionnaire was evaluated to analyze patients' quality of life. The return to activity rate was 92.9%. In total, 64% of the physically active patients had already taken up sports within 3 months after surgery. Mean Tegner's score was at 3.5, and mean UCLA score was at 6.3. High impact sports were not performed very often after surgery. Higher BMI showed a negative correlation with the numbers of sports (rsp = -0.289) as well as Tegner's (rsp = -0.222) and UCLA (rsp = -0.383) scores. The SF-36 scores were comparably good to those in an age-equivalent standard reference group. In conclusion, cementless OUKR allows a fast return to activity with a high level of physical exercise. Patients with increased BMI tend to practice less types of sports with decreased activity scores.


Assuntos
Artroplastia do Joelho , Osteoartrite do Joelho , Esportes , Exercício Físico , Humanos , Osteoartrite do Joelho/cirurgia , Qualidade de Vida , Volta ao Esporte , Resultado do Tratamento
19.
J Clin Med ; 9(5)2020 May 14.
Artigo em Inglês | MEDLINE | ID: mdl-32423118

RESUMO

(1) Background: Studies show several advantages of unicompartmental knee replacement (UKR) over total knee replacements (TKR), whereas registry based revision rates of UKR are significantly higher than for TKA. Registry data report lower revision rates for cementless UKR compared to cemented UKR. The aim of this study was to assess clinical and radiological results of cementless Oxford UKR (OUKR) in an independent cohort. (2) Methods: This retrospective cohort study examines a consecutive series of 228 cementless OUKR. Clinical outcome was measured using functional scores (Oxford Knee Score (OKS), American Knee Society Score (AKSS), Hannover Functional Ability Questionnaire for Osteoarthritis (FFbH-OA), range of motion (ROM)), pain and satisfaction. Radiographs were analyzed regarding the incidence of radiolucent lines (RL), implant positioning, and their possible impact on clinical outcome. (3) Results: At a mean follow-up of 37.1 months, the two and three year revision free survival-rates were 97.5% and 96.9%. Reasons for revision surgery were progression of osteoarthritis, inlay dislocation and pain. All clinical outcome scores showed a significant improvement from pre- to postoperative. The incidence of RL around the implant was highest within the first year postoperatively (36%), and decreased (5%) within the second year. Their presence was not correlated with inferior clinical outcome. Implant positioning showed no influence on clinical outcome. (4) Conclusion: Cementless OUKR showed excellent clinical outcome and survival rates, with reliable osteointegration. Neither the incidence of radiolucent lines nor implant positioning were associated with inferior clinical outcome.

20.
J Clin Med ; 9(9)2020 Sep 06.
Artigo em Inglês | MEDLINE | ID: mdl-32899901

RESUMO

(1) Background: The objective of the present study was to investigate peripheral blood lymphocyte subpopulations in patients with small diameter metal-on-metal total hip arthroplasty (MoM THA) and elevated blood metal ion concentrations at long-term follow-up. The hypothesis was that increased blood metal ion levels or the presence of adverse local tissue reactions (ALTR) would be associated with changes in the peripheral expression of lymphocyte subpopulations, which could potentially serve as early diagnostic markers for metal wear related complications. (2) Methods: Peripheral blood samples were analyzed for leucocyte subgroups (CD3+, CD4+, CD8+, CD14+, CD16+/CD56+, CD25+/CD127-, CD19+, IFN-γ+, IL-4+ and IL-17A+ cells) in 34 patients with elevated blood metal ion levels (combined cobalt and chromium levels >2 µg/L) following small head MoM THA at a mean follow-up of 15.6 years. Fifteen patients with small head MoM THA and blood metal ion levels within the normal range and 15 patients with conventional ceramic-on-polyethylene THA served as control groups. In addition, blood metal ion levels and leucocyte subpopulations were compared between patients with and without adverse local tissue reactions (ALTR), which was investigated by MRI in 27 patients of the study cohort. (3) Results: There was a significant decrease in the levels of IFN-γ+ Type-1 T helper cells (Th1) in patients with MoM THA compared to the ceramic-on-polyethylene control group (p < 0.001). No statistically significant differences in the cell counts of other lymphocyte subpopulations were found between the three groups. Cobalt ion levels were significantly higher in patients with ALTR (p < 0.001) compared to the non-ALTR group, but no differences in the levels of lymphocyte subsets were found between the two groups. (4) Conclusions: No adverse systemic effects with respect to peripheral blood leucocyte subpopulations could be detected in the present study in patients following THA with a small diameter MoM articulation at long-term follow-up. We found a significant decrease of IFN-γ+ Th1 cells in patients with MoM THA compared to the control group, but no differences in the peripheral expression of leucocyte subpopulations were seen between patients with and without ALTR. Future studies with larger patient cohorts and additional histopathological investigations could help to better understand the role of Th1 cells and other cell lines of the adaptive immune system in the development of metal wear related complications after total joint replacement.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA