Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Radiat Res ; 171(2): 225-35, 2009 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-19267549

RESUMO

Space radiation hazards are recognized as a key concern for human space flight. For long-term interplanetary missions, they constitute a potentially limiting factor since current protection limits for low-Earth orbit missions may be approached or even exceeded. In such a situation, an accurate risk assessment requires knowledge of equivalent doses in critical radiosensitive organs rather than only skin doses or ambient doses from area monitoring. To achieve this, the MATROSHKA experiment uses a human phantom torso equipped with dedicated detector systems. We measured for the first time the doses from the diverse components of ionizing space radiation at the surface and at different locations inside the phantom positioned outside the International Space Station, thereby simulating an extravehicular activity of an astronaut. The relationships between the skin and organ absorbed doses obtained in such an exposure show a steep gradient between the doses in the uppermost layer of the skin and the deep organs with a ratio close to 20. This decrease due to the body self-shielding and a concomitant increase of the radiation quality factor by 1.7 highlight the complexities of an adequate dosimetry of space radiation. The depth-dose distributions established by MATROSHKA serve as benchmarks for space radiation models and radiation transport calculations that are needed for mission planning.


Assuntos
Radiação Cósmica , Modelos Anatômicos , Voo Espacial , Humanos
2.
Z Med Phys ; 18(4): 233-43, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-19205293

RESUMO

The radiation exposure in space by cosmic radiation can be reduced through careful mission planning and constructive measures as example the provision of a radiation shelter, but it cannot be completely avoided. The reason for that are the extreme high energies of particles in this field and the herewith connected high penetration depth in matter. For missions outside the magnetosphere ionizing radiation is recognized as the key factor through its impact on crew health and performance. In absence of sporadic solar particle events the radiation exposure in Low Earth orbit (LEO) inside Spacecraft is determined by the galactic cosmic radiation (protons and heavier ions) and by the protons inside the South Atlantic Anomaly (SAA), an area where the radiation belt comes closer to the earth surface due to a displacement of the magnetic dipole axes from the Earth's center. In addition there is an albedo source of neutrons produced as interaction products of the primary galactic particles with the atoms of the earth atmosphere. Outside the spacecraft the dose is dominated by the electrons of the horns of the radiation belt located at about 60" latitude in Polar Regions. The radiation field has spatial and temporal variations in dependence of the Earth magnetic field and the solar cycle. The complexity of the radiation field inside a spacecraft is further increased through the interaction of the high energy components with the spacecraft shielding material and with the body of the astronauts. In interplanetary missions the radiation belt will be crossed in a couple of minutes and therefore its contribution to their radiation exposure is quite small, but subsequently the protection by the Earth magnetic field is lost, leaving only shielding measures as exposure reduction means. The report intends to describe the radiation field in space, the interaction of the particles with the magnetic field and shielding material and give some numbers on the radiation exposure in low earth orbits and in interplanetary missions.


Assuntos
Astronautas , Radiação Cósmica/efeitos adversos , Planeta Terra , Monitoramento de Radiação/métodos , Voo Espacial , Astronave , Luz Solar/efeitos adversos , Campos Eletromagnéticos/efeitos adversos , Humanos
3.
Radiat Prot Dosimetry ; 120(1-4): 387-96, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16766573

RESUMO

The radiation exposure in space missions can be reduced by careful mission planning and appropriate measures, such as provision of a radiation shelter, but it cannot be eliminated. The reason for that is the high penetration capability of the radiation components owing to their high energies. Radiation is therefore an acknowledged primary concern for manned spaceflight and is a potentially limiting factor for long-term orbital and interplanetary missions. The radiation environment is a complex mixture of charged particles of solar and galactic origin and of the radiation belts, as well as of secondary particles produced in interactions of the galactic cosmic particles with the nuclei of atmosphere of the earth. The complexity even increases by placing a spacecraft into this environment owing to the interaction of the radiation components with the shielding material. Therefore it is a challenge to provide for appropriate measurements in this radiation field, coping with the limited resources on experiment power and mass. Solid-state dosemeters were already chosen for measurements in the first manned flights. Thermoluminescence dosemeters (TLDs) and plastic nuclear track detectors (PNTD) especially found a preferred application because they are light-weighted, need no power supply and they are tissue-equivalent. Most of the data available until 1996 were gathered by using these passive detectors; this especially holds for heavy ion particle spectra. The systems, supplemented by converter foils or fission detectors and bubble detectors, provide information on dose, particle flux-, energy- and linear energy transfer spectra of the ionising radiation and neutron fluxes and doses. From 1989, silicon detectors were used for dose and flux measurements and later on for particle spectrometry. Silicon detectors were demonstrated as a powerful tool for the description of space radiation environment. Optical simulated luminescence (OSL) detectors have now been introduced as a new system in space research. Both, OSL and superheated drop detectors are candidates for personal dosimetry systems. The article will summarise past results, and results of measurements performed recently on the ISS, and conclude with future aspects.


Assuntos
Radiação Cósmica , Exposição Ocupacional/análise , Semicondutores , Voo Espacial/instrumentação , Voo Espacial/tendências , Dosimetria Termoluminescente/instrumentação , Dosimetria Termoluminescente/tendências , Desenho de Equipamento , Análise de Falha de Equipamento , Previsões , Humanos , Voo Espacial/métodos , Avaliação da Tecnologia Biomédica , Dosimetria Termoluminescente/métodos
4.
Radiat Prot Dosimetry ; 120(1-4): 442-5, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16644992

RESUMO

On 29 January 2004 the MATROSHKA facility was launched with a Russian Progress to the International Space Station. MATROSHKA is an ESA project, which has been achieved under the direction of the German Aerospace Center (DLR). The project is a cooperation of >16 research institutes from all over the world and is currently the biggest international experiment in radiation dosimetry ever performed in space. The facility simulates, as exact as possible, an astronaut during an extravehicular activity. It was successfully installed outside the Russian segment 'Zvezda' on 26 February 2004 and will remain there for a 1.5 year exposure period. The main task of the facility is to measure particle fluence and energy spectra, dose and dose rates outside and inside--including organ dose determination--in an anthropomorphic phantom mounted on the outside of the Space Station with passive and active dosemeter systems.


Assuntos
Radiação Cósmica , Exposição Ocupacional/análise , Proteção Radiológica/instrumentação , Voo Espacial/instrumentação , Dosimetria Termoluminescente/instrumentação , Carga Corporal (Radioterapia) , Relação Dose-Resposta à Radiação , Desenho de Equipamento , Análise de Falha de Equipamento , Doses de Radiação , Eficiência Biológica Relativa , Reprodutibilidade dos Testes , Federação Russa , Sensibilidade e Especificidade , Voo Espacial/métodos , Propriedades de Superfície , Dosimetria Termoluminescente/métodos
5.
Life Sci Space Res (Amst) ; 8: 38-51, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26948012

RESUMO

Most accelerator-based space radiation experiments have been performed with single ion beams at fixed energies. However, the space radiation environment consists of a wide variety of ion species with a continuous range of energies. Due to recent developments in beam switching technology implemented at the NASA Space Radiation Laboratory (NSRL) at Brookhaven National Laboratory (BNL), it is now possible to rapidly switch ion species and energies, allowing for the possibility to more realistically simulate the actual radiation environment found in space. The present paper discusses a variety of issues related to implementation of galactic cosmic ray (GCR) simulation at NSRL, especially for experiments in radiobiology. Advantages and disadvantages of different approaches to developing a GCR simulator are presented. In addition, issues common to both GCR simulation and single beam experiments are compared to issues unique to GCR simulation studies. A set of conclusions is presented as well as a discussion of the technical implementation of GCR simulation.


Assuntos
Radiação Cósmica , Laboratórios , Radiobiologia , Pesquisa , Estados Unidos , United States National Aeronautics and Space Administration
6.
Radiat Prot Dosimetry ; 166(1-4): 290-4, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25969529

RESUMO

In this study, results are presented from the on-board radiation assessment detector (RAD) of Mars Science Laboratory (MSL). RAD is designed to measure the energetic particle radiation environment, which consists of galactic cosmic rays (GCRs) and solar energetic particles (SEPs) as well as secondary particles created by nuclear interactions of primary particles in the shielding (during cruise) or Martian soil and atmosphere (surface measurements). During the cruise, RAD collected data on space radiation from inside the craft, thus allowing for a reasonable estimation of what a human crew travelling to/from Mars might be exposed to. On the surface of Mars, RAD is shielded by the atmosphere (from above) and the planet itself (from below). RAD measures the first detailed radiation data from the surface of another planet, and they are highly relevant for planning future crewed missions. The results for radiation dose and dose equivalent (a quantity most directly related to human health risk) are presented during the cruise phase, as well as on the Martian surface. Dose and dose equivalent are dominated by the continuous GCR radiation, but several SEP events were also detected and are discussed here.


Assuntos
Radiação Cósmica , Meio Ambiente Extraterreno , Marte , Modelos Teóricos , Exposição Ocupacional/prevenção & controle , Atividade Solar , Voo Espacial , Astronautas , Exposição Ambiental/efeitos adversos , Humanos , Proteção Radiológica , Medição de Risco
7.
J Radiat Res ; 43 Suppl: S59-62, 2002 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-12793731

RESUMO

Lithium fluoride thermoluminescence (TL) detectors, with different Li composition (Li-6 and Li-7) and various activators (LiF:Mg,Ti, LiF:Mg,Cu,P), are widely used for dosimetry in space. The primary radiation field in space is composed of fast electrons, protons and heavy charged particles (HCP). By its interaction with the structures of the spacecraft, this field may be modified inside the crew cabin. Therefore, calibration of TL detectors against a dose of gamma-rays is not sufficient for relating the TL readout to absorbed dose or to quantities relevant in radiation protection, without suitable correction. We introduce and calculate the detection efficiency, eta, relative to gamma-ray dose, of lithium fluoride detectors after proton and heavy charged particle (HCP) irradiation. We calculate eta for MCP-N (LiF:Mg,Cu,P) and for MTS-N (LiF:Mg,Ti) using microdosimetric models. The microdosimetric distributions used in these models (for HCP of charges between Z=1 to Z=8 and in the energy range between 0.3 MeV/amu and 20 MeV/amu) are calculated using an analytical model, based on the results of Monte Carlo simulated charged particle tracks using the MOCA-14 code. The ratio etaMCP-N/etaMTS-N for protons of stopping power (in water) below 10 keV/microm lies in the range between 0.65 and 1.0 and for HCP with Z>1--between 0.3 and 0.6. The stopping power of the particle is found not to be a unique parameter to scale the response of TL detectors. The combination of response of LiF:Mg,Cu,P and LiF:Mg,Cu,P detectors can be more suitable for a dose correction in space radiation fields.


Assuntos
Radiação Cósmica , Transferência Linear de Energia , Modelos Teóricos , Dosimetria Termoluminescente , Simulação por Computador , Meio Ambiente Extraterreno , Método de Monte Carlo , Dosimetria Termoluminescente/instrumentação
8.
Science ; 343(6169): 1244797, 2014 Jan 24.
Artigo em Inglês | MEDLINE | ID: mdl-24324275

RESUMO

The Radiation Assessment Detector (RAD) on the Mars Science Laboratory's Curiosity rover began making detailed measurements of the cosmic ray and energetic particle radiation environment on the surface of Mars on 7 August 2012. We report and discuss measurements of the absorbed dose and dose equivalent from galactic cosmic rays and solar energetic particles on the martian surface for ~300 days of observations during the current solar maximum. These measurements provide insight into the radiation hazards associated with a human mission to the surface of Mars and provide an anchor point with which to model the subsurface radiation environment, with implications for microbial survival times of any possible extant or past life, as well as for the preservation of potential organic biosignatures of the ancient martian environment.


Assuntos
Radiação Cósmica , Exobiologia , Meio Ambiente Extraterreno , Marte , Deinococcus/fisiologia , Deinococcus/efeitos da radiação , Humanos , Compostos Orgânicos/análise , Doses de Radiação , Voo Espacial , Propriedades de Superfície/efeitos da radiação
9.
Astrobiology ; 12(5): 374-86, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22680684

RESUMO

The multi-user facility EXPOSE-E was designed by the European Space Agency to enable astrobiology research in space (low-Earth orbit). On 7 February 2008, EXPOSE-E was carried to the International Space Station (ISS) on the European Technology Exposure Facility (EuTEF) platform in the cargo bay of Space Shuttle STS-122 Atlantis. The facility was installed at the starboard cone of the Columbus module by extravehicular activity, where it remained in space for 1.5 years. EXPOSE-E was returned to Earth with STS-128 Discovery on 12 September 2009 for subsequent sample analysis. EXPOSE-E provided accommodation in three exposure trays for a variety of astrobiological test samples that were exposed to selected space conditions: either to space vacuum, solar electromagnetic radiation at >110 nm and cosmic radiation (trays 1 and 3) or to simulated martian surface conditions (tray 2). Data on UV radiation, cosmic radiation, and temperature were measured every 10 s and downlinked by telemetry. A parallel mission ground reference (MGR) experiment was performed on ground with a parallel set of hardware and samples under simulated space conditions. EXPOSE-E performed a successful 1.5-year mission in space.


Assuntos
Exobiologia , Arquitetura de Instituições de Saúde , Voo Espacial , Radiação Cósmica , Planeta Terra , Desenho de Equipamento , Raios Ultravioleta
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA