Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 39
Filtrar
1.
Eur Heart J ; 35(22): 1486-95, 2014 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-24419806

RESUMO

AIMS: To provide a comprehensive histopathological validation of cardiac magnetic resonance (CMR) and endocardial voltage mapping of acute and chronic atrial ablation injury. METHODS AND RESULTS: 16 pigs underwent pre-ablation T2-weighted (T2W) and late gadolinium enhancement (LGE) CMR and high-density voltage mapping of the right atrium (RA) and both were repeated after intercaval linear radiofrequency ablation. Eight pigs were sacrificed following the procedure for pathological examination. A further eight pigs were recovered for 8 weeks, before chronic CMR, repeat RA voltage mapping and pathological examination. Signal intensity (SI) thresholds from 0 to 15 SD above a reference SI were used to segment the RA in CMR images and segmentations compared with real lesion volumes. The SI thresholds that best approximated histological volumes were 2.3 SD for LGE post-ablation, 14.5 SD for T2W post-ablation and 3.3 SD for LGE chronically. T2-weighted chronically always underestimated lesion volume. Acute histology showed transmural injury with coagulative necrosis. Chronic histology showed transmural fibrous scar. The mean voltage at the centre of the ablation line was 3.3 mV pre-ablation, 0.6 mV immediately post-ablation, and 0.3 mV chronically. CONCLUSION: This study presents the first histopathological validation of CMR and endocardial voltage mapping to define acute and chronic atrial ablation injury, including SI thresholds that best match histological lesion volumes. An understanding of these thresholds may allow a more informed assessment of the underlying atrial substrate immediately after ablation and before repeat catheter ablation for atrial arrhythmias.


Assuntos
Ablação por Cateter/efeitos adversos , Eletrodiagnóstico/métodos , Traumatismos Cardíacos/patologia , Angiografia por Ressonância Magnética/métodos , Doença Aguda , Animais , Técnicas de Imagem Cardíaca/métodos , Doença Crônica , Meios de Contraste , Feminino , Átrios do Coração/patologia , Compostos Organometálicos , Suínos , Porco Miniatura
3.
Int J Clin Pract ; 67(8): 733-9, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23869676

RESUMO

INTRODUCTION: A significant number of patients experience inappropriate shock therapy (IST) from implantable cardioverter-defibrillators (ICD). An increasing number of patients with advanced heart failure receive combined ICD and cardiac resynchronisation therapy devices (CRT-D). The incidence of IST in this group is less well described. We aimed to assess the incidence and predictors of IST in CRT-D patients. METHODS: A retrospective cohort study of prospectively collected data on patients who received an ICD and CRT-D between October 2007 and January 2009 at our institution were studied. The primary outcome measures were the IST event rate and all-cause mortality. RESULTS: A total of 185 patients with ICD/CRT-D (100/85) were included in the analysis. Eighteen patients experienced 35 episodes of IST during the follow-up (21 ± 13 months). There was a significantly lower IST cumulative event rate in the CRT-D vs. ICD group, 5% (CI: 1-13%) vs. 19% (95% CI: 11-30%) by 24 months, (p = 0.017). The majority of the IST was caused by atrial arrhythmias with atrial fibrillation accounting for 28 episodes of IST in nine patients. Multivariate analysis using Cox hazard model including baseline characteristics and coexisting appropriate shock therapy showed that a history of atrial fibrillation/flutter was the strongest independent predictor of IST with a hazard ratio of 3.53 (p = 0.019). CONCLUSION: Patients with CRT-D had a significantly lower incidence of IST compared with patients receiving an ICD. Given that atrial arrhythmia remained the commonest trigger for IST, our finding lends support to the hypothesis that CRT may reduce atrial fibrillation burden in patients receiving CRT-D.


Assuntos
Fibrilação Atrial/terapia , Dispositivos de Terapia de Ressincronização Cardíaca/efeitos adversos , Desfibriladores Implantáveis/efeitos adversos , Insuficiência Cardíaca/terapia , Idoso , Terapia de Ressincronização Cardíaca/mortalidade , Causas de Morte , Terapia Combinada , Falha de Equipamento , Feminino , Humanos , Masculino , Estudos Prospectivos , Estudos Retrospectivos
4.
Europace ; 14(6): 914-5, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22120991

RESUMO

Phrenic nerve stimulation (PNS) is a frequent occurrence in patients implanted with a cardiac resynchronization therapy device. We present a case where identification of the left pericardiophrenic vein, which runs alongside the phrenic nerve, was used to guide left ventricular lead placement in order to minimize the risk of PNS.


Assuntos
Pontos de Referência Anatômicos/diagnóstico por imagem , Terapia de Ressincronização Cardíaca/métodos , Eletrodos Implantados , Isquemia Miocárdica/terapia , Nervo Frênico/anatomia & histologia , Veias/anatomia & histologia , Terapia de Ressincronização Cardíaca/efeitos adversos , Eletrodos Implantados/efeitos adversos , Próteses Valvulares Cardíacas , Humanos , Lasers , Masculino , Pessoa de Meia-Idade , Flebografia , Implantação de Prótese/métodos , Insuficiência da Valva Tricúspide/cirurgia
5.
Pacing Clin Electrophysiol ; 35(2): 204-14, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22040178

RESUMO

BACKGROUND: Response to cardiac resynchronization therapy (CRT) is reduced in patients with posterolateral scar. Multipolar pacing leads offer the ability to select desirable pacing sites and/or stimulate from multiple pacing sites concurrently using a single lead position. Despite this potential, the clinical evaluation and identification of metrics for optimization of multisite CRT (MCRT) has not been performed. METHODS: The efficacy of MCRT via a quadripolar lead with two left ventricular (LV) pacing sites in conjunction with right ventricular pacing was compared with single-site LV pacing using a coupled electromechanical biophysical model of the human heart with no, mild, or severe scar in the LV posterolateral wall. RESULT: The maximum dP/dt(max) improvement from baseline was 21%, 23%, and 21% for standard CRT versus 22%, 24%, and 25% for MCRT for no, mild, and severe scar, respectively. In the presence of severe scar, there was an incremental benefit of multisite versus standard CRT (25% vs 21%, 19% relative improvement in response). Minimizing total activation time (analogous to QRS duration) or minimizing the activation time of short-axis slices of the heart did not correlate with CRT response. The peak electrical activation wave area in the LV corresponded with CRT response with an R(2) value between 0.42 and 0.75. CONCLUSION: Biophysical modeling predicts that in the presence of posterolateral scar MCRT offers an improved response over conventional CRT. Maximizing the activation wave area in the LV had the most consistent correlation with CRT response, independent of pacing protocol, scar size, or lead location.


Assuntos
Estimulação Cardíaca Artificial/métodos , Sistema de Condução Cardíaco/fisiopatologia , Insuficiência Cardíaca/fisiopatologia , Modelos Cardiovasculares , Disfunção Ventricular Esquerda/fisiopatologia , Simulação por Computador , Feminino , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/prevenção & controle , Frequência Cardíaca , Humanos , Pessoa de Meia-Idade , Resultado do Tratamento , Disfunção Ventricular Esquerda/complicações , Disfunção Ventricular Esquerda/prevenção & controle
6.
Int J Clin Pract ; 66(2): 218-25, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22257047

RESUMO

BACKGROUND: The rising number of device implantation has seen a parallel in the rising numbers of lead extraction. Herein we have analysed our experience in cardiac device and lead extraction in a single tertiary centre over the last decade. METHOD: Retrospective analysis of all consecutive patients undergoing lead extractions performed between 2001 and 2010. Procedural success and complications as defined by the Heart Rhythm Society policy. RESULTS: A total of 745 leads were extracted with a procedural success of 98.9% [382 cases; partial success in 6.9% (26) cases] and failure in 1.1% (4). Major complication rate was 1% (four cases) and minor complication rate was 3.6%. By both univariate and multivariate analysis only duration of lead implantation was an indicator for success (p < 0.0001). The mean implantation time for failed lead extraction was 203 ± 64 months compared with 71.8 ± 16.5 months in the successful cohort (p < 0.0001). Laser-assisted extraction was required in 176 cases. With regard to extraction indication, lead malfunction/recall showed a significant increase during the study period (p = 0.03). On time trend analysis the rise in coronary sinus (CS) lead extraction over time was significant. (p = 0.02) Despite a trend for increased laser use over time this did not achieve statistical significance, p = 0.06. CONCLUSIONS: A decade's experience of percutaneous lead extraction suggests that a high procedural success rate with a low complication rate is achieved in a high-volume centre. During this time, an increase in both defibrillator and CS lead explantation and a rising trend in laser assistance with almost 50% of cases needing laser usage were observed.


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca , Remoção de Dispositivo/tendências , Adulto , Idoso , Idoso de 80 Anos ou mais , Remoção de Dispositivo/efeitos adversos , Remoção de Dispositivo/métodos , Endocardite/etiologia , Feminino , Humanos , Terapia a Laser/métodos , Terapia a Laser/tendências , Masculino , Pessoa de Meia-Idade , Falha de Prótese/tendências , Infecções Relacionadas à Prótese/prevenção & controle , Estudos Retrospectivos , Sepse/etiologia , Resultado do Tratamento , Adulto Jovem
7.
Int J Clin Pract ; 65(3): 281-8, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21314865

RESUMO

AIMS: Current guidelines advocate cardiac resynchronisation therapy (CRT) in patients with class III/IV New York Heart Association (NYHA) heart failure, depressed left ventricular function and a broad QRS. However, a significant proportion of patients do not derive any benefit from CRT. The aim of this study was to identify clinical, electrocardiographic and echocardiographic predictors of response to CRT. METHODS: A retrospective analysis of patients undergoing CRT in our institution was performed. A favourable clinical response to CRT was defined as an improvement in NYHA Heart failure class of ≥ 1 and lack of hospitalisation with heart failure. Comparisons were made between responders and non-responders in terms of baseline characteristics and potential predictors of CRT response (QRS width, presence of left bundle branch block, atrial fibrillation, evidence of mechanical dyssynchrony on echocardiography and LV lead position). RESULTS: A total of 164 patients had full follow-up data. The mean follow-up was 293 days. Of patients undergoing CRT, 90 (58.9%) had a favourable clinical response to CRT. Predictors of a lack of clinical response to CRT were male gender (p = 0.012) and chronic obstructive pulmonary disease (COPD) (0.008). Pre-implant echocardiographic dyssynchrony assessment appeared not to predict response to CRT (p = 0.87); however, there was a trend towards a positive response in those patients with significant dyssynchrony (p = 0.09) defined as interventricular delay > 40 ms or maximal LV delay of > 80 ms. CONCLUSION: Male gender and coexisting COPD were shown to be independent predictors of non-response to CRT in this cohort of patients fulfilling current criteria for CRT.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca/terapia , Doença Pulmonar Obstrutiva Crônica/complicações , Idoso , Fibrilação Atrial/complicações , Fibrilação Atrial/terapia , Desfibriladores Implantáveis , Feminino , Insuficiência Cardíaca/complicações , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores Sexuais , Resultado do Tratamento
8.
Int J Clin Pract ; 64(8): 1140-7, 2010 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-20642712

RESUMO

Cardiac rhythm management devices (pacemakers) are being increasingly implanted worldwide not only for symptomatic bradycardia, but also for the management of arrhythmia and heart failure. Their use in more elderly patients with significant comorbidities is rising steeply and consequently long-term complications are increasingly arising. Such an increase in device therapy is being paralleled by an increase in the requirement for system extraction. Safe lead extraction is central to the management of much of the complications related to pacemakers. The most common indication for lead extraction is system infection Adhesions in chronically implanted leads can become major obstacles to safe lead extraction and life-threatening bleeding and cardiac perforations may occur. Over the last 20 years, specific tools and techniques for transvenous lead extraction have been developed to assist in freeing the lead body from the adhesions. This article provides a comprehensive review of the indications, tools, techniques and outcomes for transvenous lead extraction. The success rate largely depends on the time from implant. Up to 12 months from implant, it is rare that traction alone will not suffice. For longer lead implant duration, no single technique is sufficient to address all extractions, but laser provides the best chance of extracting the entire lead. Operator experience is vital in determining success as familiarity of a wide array of techniques will increase the likelihood of uncomplicated extraction. Long implantation time, lack of operator experience, ICD lead type and female gender are risk factors for life-threatening complications. Lead extraction should therefore, ideally be performed in high volume centres with experienced staff and on-site support from a cardiothoracic surgical team able to deal with bleeding complications from cardiovascular perforation.


Assuntos
Desfibriladores Implantáveis , Remoção de Dispositivo/métodos , Marca-Passo Artificial , Cardiologia/educação , Competência Clínica/normas , Remoção de Dispositivo/efeitos adversos , Remoção de Dispositivo/instrumentação , Educação de Pós-Graduação em Medicina , Humanos , Consentimento Livre e Esclarecido , Terapia a Laser/métodos , Infecções Relacionadas à Prótese/cirurgia , Instrumentos Cirúrgicos
9.
Heart Rhythm ; 17(8): 1262-1270, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32272230

RESUMO

BACKGROUND: Epicardial pacing increases risk of ventricular tachycardia (VT) in patients with ischemic cardiomyopathy (ICM) when pacing in proximity to scar. Endocardial pacing may be less arrhythmogenic as it preserves the physiological sequences of activation and repolarization. OBJECTIVE: The purpose of this study was to determine the relative arrhythmogenic risk of endocardial compared to epicardial pacing, and the role of the transmural gradient of action potential duration (APD) and pacing location relative to scar on arrhythmogenic risk during endocardial pacing. METHODS: Computational models of ICM patients (n = 24) were used to simulate left ventricular (LV) epicardial and endocardial pacing 0.2-3.5 cm from a scar. Mechanisms were investigated in idealized models of the ventricular wall and scar. Simulations were run with/without a 20-ms transmural APD gradient in the physiological direction and with the gradient inverted. Dispersion of repolarization was computed as a surrogate of VT risk. RESULTS: Patient-specific models with a physiological APD gradient predict that endocardial pacing decreases VT risk (34%; P <.05) compared to epicardial pacing when pacing in proximity to scar (0.2 cm). Endocardial pacing location does not significantly affect VT risk, but epicardial pacing at 0.2 cm compared to 3.5 cm from scar increases it (P <.05). Inverting the transmural APD gradient reverses this trend. Idealized models predict that propagation in the direction opposite to APD gradient decreases VT risk. CONCLUSION: Endocardial pacing is less arrhythmogenic than epicardial pacing when pacing proximal to scar and is less susceptible to pacing location relative to scar. The physiological repolarization sequence during endocardial pacing mechanistically explains reduced VT risk compared to epicardial pacing.


Assuntos
Estimulação Cardíaca Artificial/métodos , Cicatriz/complicações , Simulação por Computador , Ventrículos do Coração/fisiopatologia , Taquicardia Ventricular/terapia , Cicatriz/fisiopatologia , Endocárdio , Humanos , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/fisiopatologia
10.
J Interv Card Electrophysiol ; 57(1): 115-123, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31201592

RESUMO

PURPOSE: It is uncertain whether right ventricular (RV) lead position in cardiac resynchronization therapy impacts response. There has been little detailed analysis of the activation patterns in RV septal pacing (RVSP), especially in the CRT population. We compare left bundle branch block (LBBB) activation patterns with RV pacing (RVP) within the same patients with further comparison between RV apical pacing (RVAP) and RVSP. METHODS: Body surface mapping was undertaken in 14 LBBB patients after CRT implantation. Nine patients had RVAP, 5 patients had RVSP. Activation parameters included left ventricular total activation time (LVtat), biventricular total activation time (VVtat), interventricular electrical synchronicity (VVsync), and dispersion of left ventricular activation times (LVdisp). The direction of activation wave front was also compared in each patient (wave front angle (WFA)). In silico computer modelling was applied to assess the effect of RVAP and RVSP in order to validate the clinical results. RESULTS: Patients were aged 64.6 ± 12.2 years, 12 were male, 8 were ischemic. Baseline QRS durations were 157 ± 18 ms. There was no difference in VVtat between RVP and LBBB but a longer LVtat in RVP (102.8 ± 19.6 vs. 87.4 ± 21.1 ms, p = 0.046). VVsync was significantly greater in LBBB (45.1 ± 20.2 vs. 35.9 ± 17.1 ms, p = 0.01) but LVdisp was greater in RVP (33.4 ± 5.9 vs. 27.6 ± 6.9 ms, p = 0.025). WFA did rotate clockwise with RVP vs. LBBB (82.5 ± 25.2 vs. 62.1 ± 31.7 op = 0.026). None of the measurements were different to LBBB with RVSP; however, the differences were preserved with RVAP for VVsync, LVdisp, and WFA. In silico modelling corroborated these results. CONCLUSIONS: RVAP activation differs from LBBB where RVSP appears similar. TRIAL REGISTRATION: (ClinicalTrials.gov identifier: NCT01831518).


Assuntos
Bloqueio de Ramo/terapia , Terapia de Ressincronização Cardíaca/métodos , Ventrículos do Coração , Idoso , Mapeamento Potencial de Superfície Corporal , Simulação por Computador , Eletrocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada por Raios X
11.
J Med Econ ; 22(5): 464-470, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30744444

RESUMO

BACKGROUND AND AIMS: Infection is a serious and expensive complication of Cardiac Implantable Electronic Device (CIED) procedures. A retrospective based cost analysis was performed to estimate Trust level savings of using the TYRX antibacterial envelope as a primary prevention measure against infection in a tertiary referral centre in South London, UK. METHODS: A retrospective cohort of heart failure patients with reduced ejection fraction undergoing Implantable Cardioverter Defibrillator (ICD) or Cardiac Resynchronization Therapy (CRT) procedures were evaluated. Decision-analytic modelling was performed to determine economic savings of using the envelope during CIED procedure vs CIED procedure alone. RESULTS: Over a 12 month follow-up period following CIED procedure, the observed infection rate was 3.14% (n = 5/159). The average cost of a CIED infection inpatient admission was £41,820 and, further to economic analysis, the additional costs attributable to infection was calculated at £62,213.94. A cost saving of £624 per patient by using TYRX during CIED procedure as a primary preventative measure against infection was estimated. CONCLUSIONS: TYRX would be a cost-saving treatment option amongst heart failure patients undergoing ICD and CRT device procedures based on analysis in the local geographical area of South London. If upscaled to the UK population, we estimate potential cost savings for the National Health Service (NHS).


Assuntos
Antibioticoprofilaxia/economia , Dispositivos de Terapia de Ressincronização Cardíaca/economia , Desfibriladores Implantáveis/economia , Insuficiência Cardíaca/cirurgia , Infecções Relacionadas à Prótese/prevenção & controle , Análise Custo-Benefício , Técnicas de Apoio para a Decisão , Humanos , Modelos Econômicos , Infecções Relacionadas à Prótese/economia , Estudos Retrospectivos , Centros de Atenção Terciária , Reino Unido
12.
Med Image Anal ; 57: 197-213, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31326854

RESUMO

BACKGROUND: Cardiac Resynchronization Therapy (CRT) is one of the few effective treatments for heart failure patients with ventricular dyssynchrony. The pacing location of the left ventricle is indicated as a determinant of CRT outcome. OBJECTIVE: Patient specific computational models allow the activation pattern following CRT implant to be predicted and this may be used to optimize CRT lead placement. METHODS: In this study, the effects of heterogeneous cardiac substrate (scar, fast endocardial conduction, slow septal conduction, functional block) on accurately predicting the electrical activation of the LV epicardium were tested to determine the minimal detail required to create a rule based model of cardiac electrophysiology. Non-invasive clinical data (CT or CMR images and 12 lead ECG) from eighteen patients from two centers were used to investigate the models. RESULTS: Validation with invasive electro-anatomical mapping data identified that computer models with fast endocardial conduction were able to predict the electrical activation with a mean distance errors of 9.2 ±â€¯0.5 mm (CMR data) or (CT data) 7.5 ±â€¯0.7 mm. CONCLUSION: This study identified a simple rule-based fast endocardial conduction model, built using non-invasive clinical data that can be used to rapidly and robustly predict the electrical activation of the heart. Pre-procedural prediction of the latest electrically activating region to identify the optimal LV pacing site could potentially be a useful clinical planning tool for CRT procedures.


Assuntos
Terapia de Ressincronização Cardíaca , Técnicas Eletrofisiológicas Cardíacas , Sistema de Condução Cardíaco/fisiopatologia , Insuficiência Cardíaca/fisiopatologia , Interpretação de Imagem Assistida por Computador/métodos , Imagem Cinética por Ressonância Magnética , Tomografia Computadorizada por Raios X , Eletrocardiografia , Mapeamento Epicárdico , Humanos , Valor Preditivo dos Testes
13.
Phys Med Biol ; 60(20): 8087-108, 2015 Oct 21.
Artigo em Inglês | MEDLINE | ID: mdl-26425860

RESUMO

Determination of the cardiorespiratory phase of the heart has numerous applications during cardiac imaging. In this article we propose a novel view-angle independent near-real time cardiorespiratory motion gating and coronary sinus (CS) catheter tracking technique for x-ray fluoroscopy images that are used to guide cardiac electrophysiology procedures. The method is based on learning CS catheter motion using principal component analysis and then applying the derived motion model to unseen images taken at arbitrary projections, using the epipolar constraint. This method is also able to track the CS catheter throughout the x-ray images in any arbitrary subsequent view. We also demonstrate the clinical application of our model on rotational angiography sequences. We validated our technique in normal and very low dose phantom and clinical datasets. For the normal dose clinical images we established average systole, end-expiration and end-inspiration gating success rates of 100%, 85.7%, and 92.3%, respectively. For very low dose applications, the technique was able to track the CS catheter with median errors not exceeding 1 mm for all tracked electrodes. Average gating success rates of 80.3%, 71.4%, and 69.2% were established for the application of the technique on clinical datasets, even with a dose reduction of more than 10 times. In rotational sequences at normal dose, CS tracking median errors were within 1.2 mm for all electrodes, and the gating success rate was 100%, for view angles from RAO 90° to LAO 90°. This view-angle independent technique can extract clinically useful cardiorespiratory motion information using x-ray doses significantly lower than those currently used in clinical practice.


Assuntos
Técnicas de Imagem de Sincronização Cardíaca/métodos , Seio Coronário/diagnóstico por imagem , Eletrofisiologia , Cardiopatias/diagnóstico por imagem , Coração/diagnóstico por imagem , Imagens de Fantasmas , Técnicas de Imagem de Sincronização Respiratória/métodos , Ablação por Cateter , Seio Coronário/fisiopatologia , Fluoroscopia/métodos , Coração/fisiopatologia , Cardiopatias/terapia , Humanos , Processamento de Imagem Assistida por Computador/métodos , Movimento (Física) , Análise de Componente Principal , Respiração , Razão Sinal-Ruído , Raios X
14.
Heart Rhythm ; 12(6): 1183-91, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25680307

RESUMO

BACKGROUND: Permanent cardiac pacemakers have historically been considered a contraindication to magnetic resonance imaging (MRI). OBJECTIVE: The purpose of the ProMRI/ProMRI AFFIRM Study, which was a multicenter, prospective, single-arm, nonrandomized study, was to evaluate the clinical safety of the Biotronik ProMRI Pacemaker System under specific MRI conditions. METHODS: The ProMRI Study (in the United States) and the ProMRI AFFIRM study (outside the United States) with identical design enrolled 272 patients with stable baseline pacing indices implanted with an Entovis or Evia pacemaker (DR-T or SR-T) and Setrox or Safio 53-cm or 60-cm lead. Device interrogation was performed at enrollment, pre-MRI and post-MRI scan, and 1 and 3 months post-MRI. End-points were (1) freedom from MRI- and pacing system-related serious adverse device effects (SADEs) through 1 month post-MRI, (2) freedom from atrial and ventricular MRI-induced pacing threshold increase (>0.5 V), and (3) freedom from P- and R-wave amplitude attenuation (<50%), or P wave <1.5 mV, or R wave <5.0 mV at 1 month post-MRI. RESULTS: Two hundred twenty-six patients completed the MRI and 1-month post-MRI follow-up. No adverse events related to the implanted system and the MRI procedure occurred, resulting in an SADE-free rate of 100.0% (229/229, P <.001). Freedom from atrial and ventricular pacing threshold increase was 99.0% (189/191, P = .003) and 100% (217/217, P <.001), respectively. Freedom from P- and R- wave amplitude attenuation was 99.4% (167/168, P <.001) and 99.5% (193/194, P <.001), respectively. CONCLUSION: The results of the ProMRI/ProMRI AFFIRM studies demonstrate the clinical safety and efficacy of the ProMRI pacemaker system in patients subjected to head and lower lumbar MRI conditions.


Assuntos
Cabeça , Vértebras Lombares , Imageamento por Ressonância Magnética , Marca-Passo Artificial , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Imageamento por Ressonância Magnética/efeitos adversos , Masculino , Pessoa de Meia-Idade , Marca-Passo Artificial/efeitos adversos , Estudos Prospectivos
15.
Heart ; 81(4): 404-11, 1999 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-10092568

RESUMO

BACKGROUND: Myocardial stunning is known to occur following a single episode of effort angina in patients with coronary artery disease. The effect on left ventricular (LV) function of repeated episodes of ischaemia is unknown. OBJECTIVES: To investigate the effects of repeated episodes of exercise induced ischaemia on LV function in patients with chronic stable angina. METHODS: Patients with significant coronary artery disease and normal LV function underwent two episodes of symptom limited treadmill exercise separated by three different time intervals: either 30 minutes (group A, n = 14); 60 minutes (group B, n = 14); or 240 minutes (group C, n = 14). Quantitative stress echocardiography was performed at repeated intervals between the two exercises and for 240 minutes following the second test. RESULTS: For all groups there was no difference between the degree of ischaemia judged by maximal ST depression during the two tests. All episodes of exercise induced ischaemia produced prolonged abnormalities of LV systolic and diastolic function despite rapid normalisation of haemodynamic and ECG changes. In group A (30 minutes) these abnormalities were less pronounced after the second test than after the first, while in group B (60 minutes) they were more severe and long lasting. In group C (240 minutes) the two tests produced similar abnormalities of LV function. CONCLUSIONS: Prolonged abnormalities of LV function occurred following exercise induced ischaemia with a time course consistent with myocardial stunning. The severity and degree of LV dysfunction caused by a further episode of ischaemia appear to be dependent on the time interval between ischaemic episodes.


Assuntos
Angina Pectoris/fisiopatologia , Teste de Esforço , Isquemia Miocárdica/fisiopatologia , Disfunção Ventricular Esquerda/fisiopatologia , Análise de Variância , Angina Pectoris/diagnóstico por imagem , Ecocardiografia , Humanos , Precondicionamento Isquêmico Miocárdico , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/diagnóstico por imagem , Miocárdio Atordoado/diagnóstico por imagem , Recidiva , Disfunção Ventricular Esquerda/diagnóstico por imagem
16.
Heart ; 83(3): 283-9, 2000 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-10677406

RESUMO

OBJECTIVE: To determine whether pharmacological stress leads to prolonged but reversible left ventricular dysfunction in patients with coronary artery disease, similar to that seen after exercise. DESIGN: A randomised crossover study of recovery time of systolic and diastolic left ventricular function after exercise and dobutamine induced ischaemia. SUBJECTS: 10 patients with stable angina, angiographically proven coronary artery disease, and normal left ventricular function. INTERVENTIONS: Treadmill exercise and dobutamine stress were performed on different days. Quantitative assessment of systolic and diastolic left ventricular function was performed using transthoracic echocardiography at baseline and at regular intervals after each test. RESULTS: Both forms of stress led to prolonged but reversible systolic and diastolic dysfunction. There was no difference in the maximum double product (p = 0.53) or ST depression (p = 0.63) with either form of stress. After exercise, ejection fraction was reduced at 15 and 30 minutes compared with baseline (mean (SEM), -5.6 (1.5)%, p < 0.05; and -6.1 (2.2)%, p < 0. 01), and at 30 and 45 minutes after dobutamine (-10.8 (1.8)% and -5. 5 (1.8)%, both p < 0.01). Regional analysis showed a reduction in the worst affected segment 15 and 30 minutes after exercise (-27.9 (7.2)% and -28.6 (5.7)%, both p < 0.01), and at 30 minutes after dobutamine (-32 (5.3)%, p < 0.01). The isovolumic relaxation period was prolonged 45 minutes after each form of stress (p < 0.05). CONCLUSIONS: In patients with coronary artery disease, dobutamine induced ischaemia results in prolonged reversible left ventricular dysfunction, presumed to be myocardial stunning, similar to that seen after exercise. Dobutamine induced ischaemia could therefore be used to study the pathophysiology of this phenomenon further in patients with coronary artery disease.


Assuntos
Cardiotônicos , Doença das Coronárias/fisiopatologia , Dobutamina , Exercício Físico , Disfunção Ventricular Esquerda/fisiopatologia , Idoso , Estudos Cross-Over , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/etiologia , Isquemia Miocárdica/fisiopatologia , Miocárdio Atordoado/fisiopatologia
17.
Indian Heart J ; 48(6): 721-5, 1996.
Artigo em Inglês | MEDLINE | ID: mdl-9062030

RESUMO

Hibernating myocardium is a potentially reversible form of left ventricular (LV) dysfunction the treatment of which improves function and prognosis. The identification of viable myocardium is critical in deciding which patients undergo revascularisation. Stunning is a clinically relevant phenomenon and it has been suggested that repeated episodes of stunning may cause chronic LV dysfunction. If this is the case then pharmacological agents which prevent stunning could represent a potential treatment of chronic LV dysfunction in patients with CAD.


Assuntos
Doença das Coronárias/fisiopatologia , Miocárdio Atordoado , Disfunção Ventricular Esquerda/fisiopatologia , Animais , Ecocardiografia , Humanos , Miocárdio Atordoado/diagnóstico , Miocárdio Atordoado/fisiopatologia , Tomografia Computadorizada de Emissão
18.
Hosp Med ; 63(11): 672-5, 2002 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-12474612

RESUMO

The implantable cardioverter defibrillator is the optimal treatment for both primary and secondary prevention in patients with previous aborted sudden death and with life-threatening cardiac arrhythmias. This article will review the indications and the evidence supporting implantable cardioverter defibrillator use.


Assuntos
Arritmias Cardíacas/terapia , Desfibriladores Implantáveis , Arritmias Cardíacas/economia , Análise Custo-Benefício , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis/economia , Seguimentos , Parada Cardíaca/economia , Parada Cardíaca/prevenção & controle , Humanos , Guias de Prática Clínica como Assunto
20.
J Mech Behav Biomed Mater ; 20: 259-71, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23499249

RESUMO

Patient-specific cardiac modelling can help in understanding pathophysiology and predict therapy effects. This requires the personalization of the geometry, kinematics, electrophysiology and mechanics. We use the Bestel-Clément-Sorine (BCS) electromechanical model of the heart, which provides reasonable accuracy with a reduced parameter number compared to the available clinical data at the organ level. We propose a preliminary specificity study to determine the relevant global parameters able to differentiate the pathological cases from the healthy controls. To this end, a calibration algorithm on global measurements is developed. This calibration method was tested successfully on 6 volunteers and 2 heart failure cases and enabled to tune up to 7 out of the 14 necessary parameters of the BCS model, from the volume and pressure curves. This specificity study confirmed domain-knowledge that the relaxation rate is impaired in post-myocardial infarction heart failure and the myocardial stiffness is increased in dilated cardiomyopathy heart failures.


Assuntos
Algoritmos , Sistema de Condução Cardíaco/fisiopatologia , Cardiopatias/fisiopatologia , Imagem Cinética por Ressonância Magnética/métodos , Modelos Cardiovasculares , Contração Miocárdica , Miocárdio/patologia , Calibragem , Simulação por Computador , Humanos , Projetos Piloto , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA