Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 50
Filtrar
1.
Am Heart J ; 263: 123-132, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37192698

RESUMO

BACKGROUND: Stress echocardiography (SE) is one of the most commonly used diagnostic imaging tests for coronary artery disease (CAD) but requires clinicians to visually assess scans to identify patients who may benefit from invasive investigation and treatment. EchoGo Pro provides an automated interpretation of SE based on artificial intelligence (AI) image analysis. In reader studies, use of EchoGo Pro when making clinical decisions improves diagnostic accuracy and confidence. Prospective evaluation in real world practice is now important to understand the impact of EchoGo Pro on the patient pathway and outcome. METHODS: PROTEUS is a randomized, multicenter, 2-armed, noninferiority study aiming to recruit 2,500 participants from National Health Service (NHS) hospitals in the UK referred to SE clinics for investigation of suspected CAD. All participants will undergo a stress echocardiogram protocol as per local hospital policy. Participants will be randomized 1:1 to a control group, representing current practice, or an intervention group, in which clinicians will receive an AI image analysis report (EchoGo Pro, Ultromics Ltd, Oxford, UK) to use during image interpretation, indicating the likelihood of severe CAD. The primary outcome will be appropriateness of clinician decision to refer for coronary angiography. Secondary outcomes will assess other health impacts including appropriate use of other clinical management approaches, impact on variability in decision making, patient and clinician qualitative experience and a health economic analysis. DISCUSSION: This will be the first study to assess the impact of introducing an AI medical diagnostic aid into the standard care pathway of patients with suspected CAD being investigated with SE. TRIAL REGISTRATION: Clinicaltrials.gov registration number NCT05028179, registered on 31 August 2021; ISRCTN: ISRCTN15113915; IRAS ref: 293515; REC ref: 21/NW/0199.


Assuntos
Doença da Artéria Coronariana , Ecocardiografia sob Estresse , Humanos , Inteligência Artificial , Medicina Estatal , Doença da Artéria Coronariana/diagnóstico por imagem , Angiografia Coronária/métodos
2.
Medicina (Kaunas) ; 58(8)2022 Aug 12.
Artigo em Inglês | MEDLINE | ID: mdl-36013554

RESUMO

Background and Objectives: Interest in artificial intelligence (AI) for outcome prediction has grown substantially in recent years. However, the prognostic role of AI using advanced cardiac magnetic resonance imaging (CMR) remains unclear. This systematic review assesses the existing literature on AI in CMR to predict outcomes in patients with cardiovascular disease. Materials and Methods: Medline and Embase were searched for studies published up to November 2021. Any study assessing outcome prediction using AI in CMR in patients with cardiovascular disease was eligible for inclusion. All studies were assessed for compliance with the Checklist for Artificial Intelligence in Medical Imaging (CLAIM). Results: A total of 5 studies were included, with a total of 3679 patients, with 225 deaths and 265 major adverse cardiovascular events. Three methods demonstrated high prognostic accuracy: (1) three-dimensional motion assessment model in pulmonary hypertension (hazard ratio (HR) 2.74, 95%CI 1.73−4.34, p < 0.001), (2) automated perfusion quantification in patients with coronary artery disease (HR 2.14, 95%CI 1.58−2.90, p < 0.001), and (3) automated volumetric, functional, and area assessment in patients with myocardial infarction (HR 0.94, 95%CI 0.92−0.96, p < 0.001). Conclusion: There is emerging evidence of the prognostic role of AI in predicting outcomes for three-dimensional motion assessment in pulmonary hypertension, ischaemia assessment by automated perfusion quantification, and automated functional assessment in myocardial infarction.


Assuntos
Hipertensão Pulmonar , Infarto do Miocárdio , Inteligência Artificial , Humanos , Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética , Valor Preditivo dos Testes , Prognóstico , Medição de Risco
3.
J Cardiovasc Magn Reson ; 19(1): 13, 2017 Feb 08.
Artigo em Inglês | MEDLINE | ID: mdl-28173819

RESUMO

BACKGROUND: It is unknown whether circumferential strain is associated with prognosis after treatment of aortic stenosis (AS). We aimed to characterise strain in severe AS, using myocardial tagging cardiovascular magnetic resonance (CMR), prior to and following Transcatheter Aortic Valve Implantation (TAVI) and Surgical Aortic Valve Replacement (SAVR), and determine whether abnormalities in strain were associated with outcome. METHODS: CMR was performed pre- and 6 m post-intervention in 98 patients (52 TAVI, 46 SAVR; 77 ± 8 years) with severe AS. TAVI patients were older (80.9 ± 6.4 vs. 73.0 ± 7.0 years, p < 0.01) with a higher STS score (2.06 ± 0.6 vs. 6.03 ± 3.4, p < 0.001). Tagged cine images were acquired at the basal, mid and apical LV levels with a complementary spatial modulation of magnetization (CSPAMM) pulse sequence. Circumferential strain, strain rate and rotation were calculated using inTag© software. RESULTS: No significant change in basal or mid LV circumferential strain, or of diastolic strain rate, was seen following either intervention. However, a significant and comparable decline in LV torsion and twist was observed (SAVR: torsion 14.08 ± 8.40 vs. 7.81 ± 4.51, p < 0.001, twist 16.17 ± 7.01 vs.12.45 ± 4.78, p < 0.01; TAVI: torsion 14.43 ± 4.66 vs. 11.20 ± 4.62, p < 0.001, twist 16.08 ± 5.36 vs. 12.36 ± 5.21, p < 0.001) which likely reflects an improvement towards normal physiology following relief of AS. Over a maximum 6.0y follow up, there were 23 (16%) deaths following valve intervention. On multivariable Cox analysis, baseline mid LV circumferential strain was significantly associated with all-cause mortality (hazard ratio, 1.03; 1.01-1.05; p = 0.009) independent of age, LV ejection fraction and STS mortality risk score. ROC analysis indicated a mid LV circumferential strain > -18.7% was associated with significantly reduced survival. CONCLUSION: TAVI and SAVR procedures are associated with comparable declines in rotational LV mechanics at 6 m, with largely unchanged strain and strain rates. Pre-operative peak mid LV circumferential strain is associated with post-operative mortality.


Assuntos
Estenose da Valva Aórtica/diagnóstico por imagem , Imagem Cinética por Ressonância Magnética , Contração Miocárdica , Função Ventricular Esquerda , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/cirurgia , Área Sob a Curva , Fenômenos Biomecânicos , Distribuição de Qui-Quadrado , Inglaterra , Feminino , Implante de Prótese de Valva Cardíaca , Humanos , Interpretação de Imagem Assistida por Computador , Estimativa de Kaplan-Meier , Masculino , Análise Multivariada , Valor Preditivo dos Testes , Modelos de Riscos Proporcionais , Estudos Prospectivos , Curva ROC , Recuperação de Função Fisiológica , Fatores de Risco , Índice de Gravidade de Doença , Software , Estresse Mecânico , Volume Sistólico , Torção Mecânica , Substituição da Valva Aórtica Transcateter , Resultado do Tratamento
4.
J Cardiovasc Magn Reson ; 19(1): 16, 2017 Feb 20.
Artigo em Inglês | MEDLINE | ID: mdl-28215181

RESUMO

BACKGROUND: Regional contractile dysfunction is a frequent finding in hypertrophic cardiomyopathy (HCM). We aimed to investigate the contribution of different tissue characteristics in HCM to regional contractile dysfunction. METHODS: We prospectively recruited 50 patients with HCM who underwent cardiovascular magnetic resonance (CMR) studies at 3.0 T including cine imaging, T1 mapping and late gadolinium enhancement (LGE) imaging. For each segment of the American Heart Association model segment thickness, native T1, extracellular volume (ECV), presence of LGE and regional strain (by feature tracking and tissue tagging) were assessed. The relationship of segmental function, hypertrophy and tissue characteristics were determined using a mixed effects model, with random intercept for each patient. RESULTS: Individually segment thickness, native T1, ECV and the presence of LGE all had significant associations with regional strain. The first multivariable model (segment thickness, LGE and ECV) demonstrated that all strain parameters were associated with segment thickness (P < 0.001 for all) but not ECV. LGE (Beta 2.603, P = 0.024) had a significant association with circumferential strain measured by tissue tagging. In a second multivariable model (segment thickness, LGE and native T1) all strain parameters were associated with both segment thickness (P < 0.001 for all) and native T1 (P < 0.001 for all) but not LGE. CONCLUSION: Impairment of contractile function in HCM is predominantly associated with the degree of hypertrophy and native T1 but not markers of extracellular fibrosis (ECV or LGE). These findings suggest that impairment of contractility in HCM is mediated by mechanisms other than extracellular expansion that include cellular changes in structure and function. The cellular mechanisms leading to increased native T1 and its prognostic significance remain to be established.


Assuntos
Cardiomiopatia Hipertrófica/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Imagem Cinética por Ressonância Magnética/métodos , Contração Miocárdica , Miocárdio/patologia , Função Ventricular Esquerda , Adulto , Fenômenos Biomecânicos , Cardiomiopatia Hipertrófica/patologia , Cardiomiopatia Hipertrófica/fisiopatologia , Estudos de Casos e Controles , Meios de Contraste/administração & dosagem , Feminino , Fibrose , Humanos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Compostos Organometálicos/administração & dosagem , Valor Preditivo dos Testes , Estudos Prospectivos , Estresse Mecânico , Volume Sistólico , Remodelação Ventricular
5.
J Cardiovasc Magn Reson ; 19(1): 73, 2017 Sep 25.
Artigo em Inglês | MEDLINE | ID: mdl-28946878

RESUMO

BACKGROUND: Expansion of the myocardial extracellular volume (ECV) is a surrogate measure of focal/diffuse fibrosis and is an independent marker of prognosis in chronic heart disease. Changes in ECV may also occur after myocardial infarction, acutely because of oedema and in convalescence as part of ventricular remodelling. The objective of this study was to investigate changes in the pattern of distribution of regional (normal, infarcted and oedematous segments) and global left ventricular (LV) ECV using semi-automated methods early and late after reperfused ST-elevation myocardial infarction (STEMI). METHODS: Fifty patients underwent cardiovascular magnetic resonance (CMR) imaging acutely (24 h-72 h) and at convalescence (3 months). The CMR protocol included: cines, T2-weighted (T2 W) imaging, pre-/post-contrast T1-maps and LGE-imaging. Using T2 W and LGE imaging on acute scans, 16-segments of the LV were categorised as normal, oedema and infarct. 800 segments (16 per-patient) were analysed for changes in ECV and wall thickening (WT). RESULTS: From the acute studies, 325 (40.6%) segments were classified as normal, 246 (30.8%) segments as oedema and 229 (28.6%) segments as infarct. Segmental change in ECV between acute and follow-up studies (Δ ECV) was significantly different for normal, oedema and infarct segments (0.8 ± 6.5%, -1.78 ± 9%, -2.9 ± 10.9%, respectively; P < 0.001). Normal segments which demonstrated deterioration in wall thickening at follow-up showed significantly increased Δ ECV compared with normal segments with preserved wall thickening at follow up (1.82 ± 6.05% versus -0.10 ± 6.88%, P < 0.05). CONCLUSION: Following reperfused STEMI, normal myocardium demonstrates subtle expansion of the extracellular volume at 3-month follow up. Segmental ECV expansion of normal myocardium is associated with worsening of contractile function.


Assuntos
Coração/fisiopatologia , Imageamento por Ressonância Magnética/métodos , Infarto do Miocárdio/patologia , Miocárdio/patologia , Edema/diagnóstico por imagem , Edema/fisiopatologia , Feminino , Fibrose , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/fisiopatologia , Estudos Prospectivos , Reino Unido , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/fisiopatologia
6.
Am Heart J ; 175: 101-11, 2016 05.
Artigo em Inglês | MEDLINE | ID: mdl-27179729

RESUMO

BACKGROUND: Cardiac adaptation to aortic stenosis (AS) appears to differ according to sex, but reverse remodeling after aortic valve replacement has not been extensively described. The aim of the study was to determine using cardiac magnetic resonance imaging whether any sex-related differences exist in AS in terms of left ventricular (LV) remodeling, myocardial fibrosis, and reverse remodeling after valve replacement. METHODS: One hundred patients (men, n = 60) with severe AS undergoing either transcatheter or surgical aortic valve replacement underwent cardiac magnetic resonance scans at baseline and 6 months after valve replacement. RESULTS: Despite similar baseline comorbidity and severity of AS, women had a lower indexed LV mass than did men (65.3 ± 18.4 vs 81.5 ± 21.3 g/m(2), P < .001) and a smaller indexed LV end-diastolic volume (87.3 ± 17.5 vs 101.2 ± 28.6 mL/m(2), P = .002) with a similar LV ejection fraction (58.6% ± 10.2% vs 54.8% ± 12.9%, P = .178). Total myocardial fibrosis mass was similar between sexes (2.3 ± 4.1 vs 1.3 ± 1.1 g, P = .714), albeit with a differing distribution according to sex. After aortic valve replacement, men had more absolute LV mass regression than did women (18.3 ± 10.6 vs 12.7 ± 8.8 g/m(2), P = .007). When expressed as a percentage reduction of baseline indexed LV mass, mass regression was similar between the sexes (men 21.7% ± 10.1% vs women 18.4% ± 11.0%, P = .121). There was no sex-related difference in postprocedural LV ejection fraction or aortic regurgitation. Sex was not found to be a predictor of LV reverse remodeling on multiple regression analysis. CONCLUSIONS: There are significant differences in the way that male and female hearts adapt to AS. Six months after aortic valve replacement, there are no sex-related differences in reverse remodeling, but superior reverse remodeling in men as a result of their more adverse remodeling profile at baseline.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca/métodos , Ventrículos do Coração , Função Ventricular Esquerda , Remodelação Ventricular , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/cirurgia , Feminino , Ventrículos do Coração/patologia , Ventrículos do Coração/fisiopatologia , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Tamanho do Órgão , Período Pós-Operatório , Fatores Sexuais , Estatística como Assunto , Volume Sistólico , Reino Unido
7.
Magn Reson Med ; 75(3): 1290-300, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25946025

RESUMO

PURPOSE: To compare methods designed to minimize or correct signal nonlinearity in quantitative myocardial dynamic contrast-enhanced (DCE) MRI. METHODS: DCE-MRI studies were simulated and data acquired in eight volunteers. Signal nonlinearity was corrected using either a dual-bolus approach or model-based correction using proton-density weighted imaging (conventional or dual-sequence acquisition) or T1 data (native or bookend). Scanning of healthy and infarcted myocardium at 3 T was simulated, including noise, saturation imperfection and T1 measurement error. Data were analyzed using model-based deconvolution with a one-compartment (mono-exponential) model. RESULTS: Substantial variation between methods was demonstrated in volunteers. In simulations the dual-bolus method proved stable for realistic levels of saturation efficiency but demonstrated bias due to residual nonlinearity. Model-based methods performed ideally in the absence of confounding error sources and were generally robust to noise or saturation imperfection, except for native T1 based correction which was highly sensitive to the latter. All methods demonstrated large variation in accuracy above an over-saturation level where baseline signal was nulled. For the dual-sequence approach this caused substantial bias at the saturation efficiencies observed in volunteers. CONCLUSION: The choice of nonlinearity correction method in myocardial DCE-MRI impacts on accuracy and precision of estimated parameters, particularly in the presence of nonideal saturation.


Assuntos
Técnicas de Imagem Cardíaca/métodos , Circulação Coronária/fisiologia , Imageamento por Ressonância Magnética/métodos , Algoritmos , Simulação por Computador , Meios de Contraste , Humanos , Dinâmica não Linear , Sensibilidade e Especificidade
8.
J Cardiovasc Magn Reson ; 18(1): 48, 2016 08 17.
Artigo em Inglês | MEDLINE | ID: mdl-27535657

RESUMO

BACKGROUND: Athletic training leads to remodelling of both left and right ventricles with increased myocardial mass and cavity dilatation. Whether changes in cardiac strain parameters occur in response to training is less well established. In this study we investigated the relationship in trained athletes between cardiovascular magnetic resonance (CMR) derived strain parameters of cardiac function and fitness. METHODS: Thirty five endurance athletes and 35 age and sex matched controls underwent CMR at 3.0 T including cine imaging in multiple planes and tissue tagging by spatial modulation of magnetization (SPAMM). CMR data were analysed quantitatively reporting circumferential strain and torsion from tagged images and left and right ventricular longitudinal strain from feature tracking of cine images. Athletes performed a maximal ramp-incremental exercise test to determine the lactate threshold (LT) and maximal oxygen uptake (V̇O2max). RESULTS: LV circumferential strain at all levels, LV twist and torsion, LV late diastolic longitudinal strain rate, RV peak longitudinal strain and RV early and late diastolic longitudinal strain rate were all lower in athletes than controls. On multivariable linear regression only LV torsion (beta = -0.37, P = 0.03) had a significant association with LT. Only RV longitudinal late diastolic strain rate (beta = -0.35, P = 0.03) had a significant association with V̇O2max. CONCLUSIONS: This cohort of endurance athletes had lower LV circumferential strain, LV torsion and biventricular diastolic strain rates than controls. Increased LT, which is a major determinant of performance in endurance athletes, was associated with decreased LV torsion. Further work is needed to understand the mechanisms by which this occurs.


Assuntos
Atletas , Cardiomegalia Induzida por Exercícios , Imagem Cinética por Ressonância Magnética , Resistência Física , Aptidão Física , Função Ventricular Esquerda , Função Ventricular Direita , Remodelação Ventricular , Adulto , Fenômenos Biomecânicos , Estudos de Casos e Controles , Estudos Transversais , Teste de Esforço , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Consumo de Oxigênio , Valor Preditivo dos Testes , Estudos Prospectivos , Torção Mecânica , Adulto Jovem
9.
J Cardiovasc Magn Reson ; 18(1): 37, 2016 06 10.
Artigo em Inglês | MEDLINE | ID: mdl-27287000

RESUMO

BACKGROUND: Aortic stiffness is increasingly used as an independent predictor of adverse cardiovascular outcomes. We sought to compare the impact of transcatheter aortic valve implantation (TAVI) and surgical aortic valve replacement (SAVR) upon aortic vascular function using cardiovascular magnetic resonance (CMR) measurements of aortic distensibility and pulse wave velocity (PWV). METHODS AND RESULTS: A 1.5 T CMR scan was performed pre-operatively and at 6 m post-intervention in 72 patients (32 TAVI, 40 SAVR; age 76 ± 8 years) with high-risk symptomatic severe aortic stenosis. Distensibility of the ascending and descending thoracic aorta and aortic pulse wave velocity were determined at both time points. TAVI and SAVR patients were comparable for gender, blood pressure and left ventricular ejection fraction. The TAVI group were older (81 ± 6.3 vs. 72.8 ± 7.0 years, p < 0.05) with a higher EuroSCORE II (5.7 ± 5.6 vs. 1.5 ± 1.0 %, p < 0.05). At 6 m, SAVR was associated with a significant decrease in distensibility of the ascending aorta (1.95 ± 1.15 vs. 1.57 ± 0.68 × 10(-3)mmHg(-1), p = 0.044) and of the descending thoracic aorta (3.05 ± 1.12 vs. 2.66 ± 1.00 × 10(-3)mmHg(-1), p = 0.018), with a significant increase in PWV (6.38 ± 4.47 vs. 11.01 ± 5.75 ms(-1), p = 0.001). Following TAVI, there was no change in distensibility of the ascending aorta (1.96 ± 1.51 vs. 1.72 ± 0.78 × 10(-3)mmHg(-1), p = 0.380), descending thoracic aorta (2.69 ± 1.79 vs. 2.21 ± 0.79 × 10(-3)mmHg(-1), p = 0.181) nor in PWV (8.69 ± 6.76 vs. 10.23 ± 7.88 ms(-1), p = 0.301) at 6 m. CONCLUSIONS: Treatment of symptomatic severe aortic stenosis by SAVR but not TAVI was associated with an increase in aortic stiffness at 6 months. Future work should focus on the prognostic implication of these findings to determine whether improved patient selection and outcomes can be achieved.


Assuntos
Aorta Torácica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca , Imagem Cinética por Ressonância Magnética , Substituição da Valva Aórtica Transcateter , Rigidez Vascular , Idoso , Idoso de 80 Anos ou mais , Aorta Torácica/fisiopatologia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Inglaterra , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Masculino , Valor Preditivo dos Testes , Estudos Prospectivos , Análise de Onda de Pulso , Índice de Gravidade de Doença , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
10.
MAGMA ; 29(5): 733-8, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27038934

RESUMO

OBJECTIVES: To compare Dixon water-fat suppression with spectral pre-saturation with inversion recovery (SPIR) at 3T for coronary magnetic resonance angiography (MRA) and to demonstrate the feasibility of fat suppressed coronary MRA at 3T without administration of a contrast agent. MATERIALS AND METHODS: Coronary MRA with Dixon water-fat separation or with SPIR fat suppression was compared on a 3T scanner equipped with a 32-channel cardiac receiver coil. Eight healthy volunteers were examined. Contrast-to-noise ratio (CNR), signal-to-noise ratio (SNR), right coronary artery (RCA), and left anterior descending (LAD) coronary artery sharpness and length were measured and statistically compared. Two experienced cardiologists graded the visual image quality of reformatted Dixon and SPIR images (1: poor quality to 5: excellent quality). RESULTS: Coronary MRA images in healthy volunteers showed improved contrast with the Dixon technique compared to SPIR (CNR blood-fat: Dixon = 14.9 ± 2.9 and SPIR = 13.9 ± 2.1; p = 0.08, CNR blood-myocardium: Dixon = 10.2 ± 2.7 and SPIR = 9.11 ± 2.6; p = 0.1). The Dixon method led to similar fat suppression (fat SNR with Dixon: 2.1 ± 0.5 vs. SPIR: 2.4 ± 1.2, p = 0.3), but resulted in significantly increased SNR of blood (blood SNR with Dixon: 19.9 ± 4.5 vs. SPIR: 15.5 ± 3.1, p < 0.05). This means the residual fat signal is slightly lower with the Dixon compared to the SIPR technique (although not significant), while the SNR of blood is significantly higher with the Dixon technique. Vessel sharpness of the RCA was similar for Dixon and SPIR (57 ± 7 % vs. 56 ± 9 %, p = 0.2), while the RCA visualized vessel length was increased compared to SPIR fat suppression (107 ± 21 vs. 101 ± 21 mm, p < 0.001). For the LAD, vessel sharpness (50 ± 13 % vs. 50 ± 7 %, p = 0.4) and vessel length (92 ± 46 vs. 90 ± 47 mm, p = 0.4) were similar with both techniques. Consequently, the Dixon technique resulted in an improved visual score of the coronary arteries in the water fat separated images of healthy subjects (RCA: 4.6 ± 0.5 vs. 4.1 ± 0.7, p = 0.01, LAD: 4.1 ± 0.7 vs. 3.5 ± 0.8, p = 0.007). CONCLUSIONS: Dixon water-fat separation can significantly improve coronary artery image quality without the use of a contrast agent at 3T.


Assuntos
Tecido Adiposo/diagnóstico por imagem , Angiografia Coronária , Vasos Coronários/diagnóstico por imagem , Angiografia por Ressonância Magnética , Imageamento por Ressonância Magnética , Adulto , Meios de Contraste/química , Feminino , Voluntários Saudáveis , Humanos , Masculino , Pessoa de Meia-Idade , Razão Sinal-Ruído , Água
11.
JAMA ; 316(10): 1051-60, 2016 Sep 13.
Artigo em Inglês | MEDLINE | ID: mdl-27570866

RESUMO

IMPORTANCE: Among patients with suspected coronary heart disease (CHD), rates of invasive angiography are considered too high. OBJECTIVE: To test the hypothesis that among patients with suspected CHD, cardiovascular magnetic resonance (CMR)-guided care is superior to National Institute for Health and Care Excellence (NICE) guidelines-directed care and myocardial perfusion scintigraphy (MPS)-guided care in reducing unnecessary angiography. DESIGN, SETTING, AND PARTICIPANTS: Multicenter, 3-parallel group, randomized clinical trial using a pragmatic comparative effectiveness design. From 6 UK hospitals, 1202 symptomatic patients with suspected CHD and a CHD pretest likelihood of 10% to 90% were recruited. First randomization was November 23, 2012; last 12-month follow-up was March 12, 2016. INTERVENTIONS: Patients were randomly assigned (240:481:481) to management according to UK NICE guidelines or to guided care based on the results of CMR or MPS testing. MAIN OUTCOMES AND MEASURES: The primary end point was protocol-defined unnecessary coronary angiography (normal fractional flow reserve >0.8 or quantitative coronary angiography [QCA] showing no percentage diameter stenosis ≥70% in 1 view or ≥50% in 2 orthogonal views in all coronary vessels ≥2.5 mm diameter) within 12 months. Secondary end points included positive angiography, major adverse cardiovascular events (MACEs), and procedural complications. RESULTS: Among 1202 symptomatic patients (mean age, 56.3 years [SD, 9.0]; women, 564 [46.9%] ; mean CHD pretest likelihood, 49.5% [SD, 23.8%]), number of patients with invasive coronary angiography after 12 months was 102 in the NICE guidelines group (42.5% [95% CI, 36.2%-49.0%])], 85 in the CMR group (17.7% [95% CI, 14.4%-21.4%]); and 78 in the MPS group (16.2% [95% CI, 13.0%-19.8%]). Study-defined unnecessary angiography occurred in 69 (28.8%) in the NICE guidelines group, 36 (7.5%) in the CMR group, and 34 (7.1%) in the MPS group; adjusted odds ratio of unnecessary angiography: CMR group vs NICE guidelines group, 0.21 (95% CI, 0.12-0.34, P < .001); CMR group vs the MPS group, 1.27 (95% CI, 0.79-2.03, P = .32). Positive angiography proportions were 12.1% (95% CI, 8.2%-16.9%; 29/240 patients) for the NICE guidelines group, 9.8% (95% CI, 7.3%-12.8%; 47/481 patients) for the CMR group, and 8.7% (95% CI, 6.4%-11.6%; 42/481 patients) for the MPS group. A MACE was reported at a minimum of 12 months in 1.7% of patients in the NICE guidelines group, 2.5% in the CMR group, and 2.5% in the MPS group (adjusted hazard ratios: CMR group vs NICE guidelines group, 1.37 [95% CI, 0.52-3.57]; CMR group vs MPS group, 0.95 [95% CI, 0.46-1.95]). CONCLUSIONS AND RELEVANCE: In patients with suspected angina, investigation by CMR resulted in a lower probability of unnecessary angiography within 12 months than NICE guideline-directed care, with no statistically significant difference between CMR and MPS strategies. There were no statistically significant differences in MACE rates. TRIAL REGISTRATION: Clinicaltrials.gov Identifier: NCT01664858.


Assuntos
Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Estenose Coronária/diagnóstico por imagem , Imagem de Perfusão do Miocárdio , Procedimentos Desnecessários/estatística & dados numéricos , Idoso , Angina Pectoris/diagnóstico por imagem , Angina Pectoris/etiologia , Angiografia Coronária/efeitos adversos , Vasos Coronários/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Imagem de Perfusão do Miocárdio/efeitos adversos , Assistência ao Paciente/normas , Guias de Prática Clínica como Assunto
12.
Radiology ; 276(3): 732-40, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25923223

RESUMO

PURPOSE: To investigate the pharmacology and potential clinical utility of splenic switch-off to identify understress in adenosine perfusion cardiac magnetic resonance (MR) imaging. MATERIALS AND METHODS: Splenic switch-off was assessed in perfusion cardiac MR examinations from 100 patients (mean age, 62 years [age range, 18-87 years]) by using three stress agents (adenosine, dobutamine, and regadenoson) in three different institutions, with appropriate ethical permissions. In addition, 100 negative adenosine images from the Clinical Evaluation of MR Imaging in Coronary Heart Disease (CE-MARC) trial (35 false and 65 true negative; mean age, 59 years [age range, 40-73 years]) were assessed to ascertain the clinical utility of the sign to detect likely pharmacologic understress. Differences in splenic perfusion were compared by using Wilcoxon signed rank or Wilcoxon rank sum tests, and true-negative and false-negative findings in CE-MARC groups were compared by using the Fisher exact test. RESULTS: The spleen was visible in 99% (198 of 200) of examinations and interobserver agreement in the visual grading of splenic switch-off was excellent (κ = 0.92). Visually, splenic switch-off occurred in 90% of adenosine studies, but never in dobutamine or regadenoson studies. Semiquantitative assessments supported these observations: peak signal intensity was 78% less with adenosine than at rest (P < .001), but unchanged with regadenoson (4% reduction; P = .08). Calculated peak splenic divided by myocardial signal intensity (peak splenic/myocardial signal intensity) differed between stress agents (adenosine median, 0.34; dobutamine median, 1.34; regadenoson median, 1.13; P < .001). Failed splenic switch-off was significantly more common in CE-MARC patients with false-negative findings than with true-negative findings (34% vs 9%, P < .005). CONCLUSION: Failed splenic switch-off with adenosine is a new, simple observation that identifies understressed patients who are at risk for false-negative findings on perfusion MR images. These data suggest that almost 10% of all patients may be understressed, and that repeat examination of individuals with failed splenic switch-off may significantly improve test sensitivity.


Assuntos
Adenosina , Técnicas de Imagem Cardíaca/métodos , Dobutamina , Teste de Esforço/métodos , Angiografia por Ressonância Magnética , Purinas , Pirazóis , Baço/fisiologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Humanos , Pessoa de Meia-Idade , Perfusão , Estudos Retrospectivos , Adulto Jovem
13.
Am Heart J ; 169(1): 17-24.e1, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25497243

RESUMO

BACKGROUND: A number of investigative strategies exist for the diagnosis of coronary heart disease (CHD). Despite the widespread availability of noninvasive imaging, invasive angiography is commonly used early in the diagnostic pathway. Consequently, approximately 60% of angiograms reveal no evidence of obstructive coronary disease. Reducing unnecessary angiography has potential financial savings and avoids exposing the patient to unnecessary risk. There are no large-scale comparative effectiveness trials of the different diagnostic strategies recommended in international guidelines and none that have evaluated the safety and efficacy of cardiovascular magnetic resonance. TRIAL DESIGN: CE-MARC 2 is a prospective, multicenter, 3-arm parallel group, randomized controlled trial of patients with suspected CHD (pretest likelihood 10%-90%) requiring further investigation. A total of 1,200 patients will be randomized on a 2:2:1 basis to receive 3.0-T cardiovascular magnetic resonance-guided care, single-photon emission computed tomography-guided care (according to American College of Cardiology/American Heart Association appropriate-use criteria), or National Institute for Health and Care Excellence guidelines-based management. The primary (efficacy) end point is the occurrence of unnecessary angiography as defined by a normal (>0.8) invasive fractional flow reserve. Safety of each strategy will be assessed by 3-year major adverse cardiovascular event rates. Cost-effectiveness and health-related quality-of-life measures will be performed. CONCLUSIONS: The CE-MARC 2 trial will provide comparative efficacy and safety evidence for 3 different strategies of investigating patients with suspected CHD, with the intension of reducing unnecessary invasive angiography rates. Evaluation of these management strategies has the potential to improve patient care, health-related quality of life, and the cost-effectiveness of CHD investigation.


Assuntos
Doença das Coronárias/diagnóstico , Imagem Cinética por Ressonância Magnética/métodos , Ensaios Clínicos Controlados Aleatórios como Assunto , Tomografia Computadorizada de Emissão de Fóton Único , Angiografia Coronária/estatística & dados numéricos , Doença das Coronárias/diagnóstico por imagem , Doença das Coronárias/economia , Análise Custo-Benefício , Humanos , Imagem Cinética por Ressonância Magnética/economia , Qualidade de Vida , Projetos de Pesquisa , Medição de Risco , Procedimentos Desnecessários/estatística & dados numéricos
14.
J Magn Reson Imaging ; 42(4): 946-53, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25857628

RESUMO

PURPOSE: To demonstrate the feasibility of an automatic adaptive acquisition sequence. Magnetic resonance perfusion pulse sequences often leave potential acquisition time unused in patients with lower heart-rates (HR) and smaller body size. MATERIALS AND METHODS: A perfusion technique was developed that automatically adapts to HR and field-of-view by maximizing in-plane spatial resolution while maintaining temporal resolution every cardiac cycle. Patients (n = 10) and volunteers (n = 10) were scanned with both a standard resolution and adaptive method. Image quality was scored, signal-to-noise ratio (SNR) calculated, and width of dark-rim artifact (DRA) measured. RESULTS: The acquired spatial resolution of the adaptive sequence (1.92 × 1.92 mm(2) ± 0.34) was higher than the standard resolution (2.42 × 2.42 mm(2) ) (P < 0.0001). Mean DRA width was reduced using the adaptive pulse sequence (1.94 ± 0.60 mm vs. 2.82 ± 0.65 mm, P < 0.0001). The signal-to-noise ratio (SNR) was higher with the standard pulse sequence (6.7 ± 2.2 vs. 3.8 ± 1.8, P < 0.0001). There was no difference in image quality score between sequences in either volunteers (1.1 ± 0.31 vs. 1.0 ± 0.0, P = 0.34) or patients (1.3 ± 0.48 vs. 1.3 ± 0.48, P = 1.0). CONCLUSION: Optimizing the use of available imaging time during first-pass perfusion with a magnetic resonance imaging pulse sequence that adapts image acquisition duration to HR and patient size is feasible. Acquired in-plane spatial resolution is improved, the DRA is reduced, and while SNR is reduced with the adaptive sequence consistent with the lower voxel size used, image quality is maintained.


Assuntos
Técnicas de Imagem de Sincronização Cardíaca/métodos , Doença da Artéria Coronariana/patologia , Teste de Esforço/métodos , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Imagem de Perfusão do Miocárdio/métodos , Adulto , Idoso , Tamanho Corporal , Estudos de Viabilidade , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Pessoa de Meia-Idade , Medicina de Precisão/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Adulto Jovem
15.
J Cardiovasc Magn Reson ; 17(1): 6, 2015 Jan 31.
Artigo em Inglês | MEDLINE | ID: mdl-25638228

RESUMO

BACKGROUND: Diffuse myocardial fibrosis may be quantified with cardiovascular magnetic resonance (CMR) by calculating extra-cellular volume (ECV) from native and post-contrast T1 values. Accurate ECV calculation is dependent upon the contrast agent having reached equilibrium within tissue compartments. Previous studies have used infusion or single bolus injections of contrast to calculate ECV. In clinical practice however, split dose contrast injection is commonly used as part of stress/rest perfusion studies. In this study we sought to assess the effects of split dose versus single bolus contrast administration on ECV calculation. METHODS: Ten healthy volunteers and five patients ( 4 ischaemic heart disease, 1 hypertrophic cardiomyopathy) were studied on a 3.0 Tesla (Philips Achieva TX) MR system and underwent two (patients) or three (volunteers) separate CMR studies over a mean of 12 and 30 days respectively. Volunteers underwent one single bolus contrast study (Gadovist 0.15mmol/kg). In two further studies, contrast was given in two boluses (0.075mmol/kg per bolus) as part of a clinical adenosine stress/rest perfusion protocol, boluses were separated by 12 minutes. Patients underwent one bolus and one stress perfusion study only. T1 maps were acquired pre contrast and 15 minutes following the single bolus or second contrast injection. RESULTS: ECV agreed between bolus and split dose contrast administration (coefficient of variability 5.04%, bias 0.009, 95% CI -3.754 to 3.772, r2 = 0.973, p = 0.001)). Inter-study agreement with split dose administration was good (coefficient of variability, 5.67%, bias -0.018, 95% CI -4.045 to 4.009, r2 = 0.766, p > 0.001). CONCLUSION: ECV quantification using split dose contrast administration is reproducible and agrees well with previously validated methods in healthy volunteers, as well as abnormal and remote myocardium in patients. This suggests that clinical perfusion CMR studies may incorporate assessment of tissue composition by ECV based on T1 mapping.


Assuntos
Meios de Contraste/administração & dosagem , Matriz Extracelular/patologia , Imagem Cinética por Ressonância Magnética , Miocárdio/patologia , Compostos Organometálicos/administração & dosagem , Adenosina , Adulto , Cardiomiopatia Hipertrófica/patologia , Relação Dose-Resposta a Droga , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/patologia , Vasodilatadores
16.
J Cardiovasc Magn Reson ; 17: 59, 2015 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-26174854

RESUMO

BACKGROUND: The CE-MARC study assessed the diagnostic performance investigated the use of cardiovascular magnetic resonance (CMR) in patients with suspected coronary artery disease (CAD). The study used a multi-parametric CMR protocol assessing 4 components: i) left ventricular function; ii) myocardial perfusion; iii) viability (late gadolinium enhancement (LGE)) and iv) coronary magnetic resonance angiography (MRA). In this pre-specified CE-MARC sub-study we assessed the diagnostic accuracy of the individual CMR components and their combinations. METHODS: All patients from the CE-MARC population (n = 752) were included using data from the original blinded-read. The four individual core components of the CMR protocol was determined separately and then in paired and triplet combinations. Results were then compared to the full multi-parametric protocol. RESULTS: CMR and X-ray angiography results were available in 676 patients. The maximum sensitivity for the detection of significant CAD by CMR was achieved when all four components were used (86.5%). Specificity of perfusion (91.8%), function (93.7%) and LGE (95.8%) on its own was significantly better than specificity of the multi-parametric protocol (83.4%) (all P < 0.0001) but with the penalty of decreased sensitivity (86.5% vs. 76.9%, 47.4% and 40.8% respectively). The full multi-parametric protocol was the optimum to rule-out significant CAD (Likelihood Ratio negative (LR-) 0.16) and the LGE component alone was the best to rue-in CAD (LR+ 9.81). Overall diagnostic accuracy was similar with the full multi-parametric protocol (85.9%) compared to paired and triplet combinations. The use of coronary MRA within the full multi-parametric protocol had no additional diagnostic benefit compared to the perfusion/function/LGE combination (overall accuracy 84.6% vs. 84.2% (P = 0.5316); LR- 0.16 vs. 0.21; LR+ 5.21 vs. 5.77). CONCLUSIONS: From this pre-specified sub-analysis of the CE-MARC study, the full multi-parametric protocol had the highest sensitivity and was the optimal approach to rule-out significant CAD. The LGE component alone was the optimal rule-in strategy. Finally the inclusion of coronary MRA provided no additional benefit when compared to the combination of perfusion/function/LGE. TRIAL REGISTRATION: Current Controlled Trials ISRCTN77246133.


Assuntos
Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico , Circulação Coronária , Vasos Coronários/patologia , Vasos Coronários/fisiopatologia , Angiografia por Ressonância Magnética/métodos , Imagem Cinética por Ressonância Magnética/métodos , Imagem de Perfusão do Miocárdio/métodos , Idoso , Doença da Artéria Coronariana/patologia , Doença da Artéria Coronariana/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Reprodutibilidade dos Testes , Função Ventricular Esquerda
17.
Echocardiography ; 32(9): 1432-4, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25736174

RESUMO

Tuberous sclerosis complex (TSC) is a neurocutaneous syndrome and multisystem disorder with autosomal dominant inheritance and variable penetrance. Cardiac rhabdomyomas have been reported in 50-64% of patients with TSC and transthoracic echocardiography is established as the primary imaging modality for their detection. The precise functional assessment of the left ventricle in these patients requires clarification. We report a case of a 19-year-old male with known TSC who was referred for outpatient transthoracic echocardiography (TTE) to investigate for the presence of cardiac rhabdomyomas. TTE demonstrated multiple rhabdomyomas with a normal ejection fraction but altered global and regional deformation on speckle tracking. The regional longitudinal strain was notably reduced in the anterior septum (-11%) and inferior septum (-15%). The global circumferential strain (GCS) was significantly reduced at -15.6%. The distribution of regional circumferential strain reduction for the mid-ventricular segment correlated with the location of cardiac rhabdomyomas.


Assuntos
Ecocardiografia Tridimensional , Ventrículos do Coração/diagnóstico por imagem , Esclerose Tuberosa/diagnóstico por imagem , Adulto , Diagnóstico Diferencial , Humanos , Masculino , Reprodutibilidade dos Testes , Adulto Jovem
18.
Clin Exp Hypertens ; 37(4): 308-16, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25271354

RESUMO

BACKGROUND: Increased arterial stiffness independently predicts adverse prognosis. While different antihypertensive strategies produce different magnitudes of left ventricular hypertrophy (LVH) regression, there are no comparative data on how these strategies affect arterial stiffness. The aim was to determine the longitudinal change in aortic stiffness following the treatment of essential hypertension with two mechanistically different antihypertensive treatment strategies. METHODS AND RESULTS: Forty-two patients with essential hypertension and CMR confirmed with LVH were randomly assigned to antihypertensive regimes for 6 months. Treatment strategies were designed either to inhibit the renin-angiotensin-aldosterone system (RAAS) and the sympathetic nervous system (SNS) (valsartan and moxonidine, group VM) or to have neutral effect on these systems (bendroflumethiazide and amlodipine, group BA). Both treatment groups underwent identical baseline and a 6-month follow-up CMR and were compared with a healthy age-matched control group. Baseline aortic distensibility (AD) was lower in both hypertensive groups compared with controls (2.8 × 10(-3 )mmHg(-1) in group VM (p = 0.001) and 3.3 × 10(-3 )mmHg(-1) group BA (p = 0.039) compared with 4.5 × 10(-3 )mmHg(-1) in the control group). AD increased after antihypertensive therapy (VM: 2.8 × 10(-3 )mmHg(-1)-4.2 × 10(-3 )mmHg(-1) (p = 0.001); BA 3.3 × 10(-3 )mmHg(-1)-4.6 × 10(-3 )mmHg(-1) (p < 0.01)). In both treatment groups AD returned to a level comparable with the normal control group (p = 0.81) after 6 months. CONCLUSIONS: In patients with essential hypertension and LVH, AD was lower than in matched normal controls. Despite the opposing pharmacological mechanisms utilised across the treatment groups, the improvement in AD was similar, suggesting that blood pressure reduction per se may be more important than RAAS and SNS inhibition for the improvement of aortic remodelling.


Assuntos
Bloqueadores do Receptor Tipo 1 de Angiotensina II/administração & dosagem , Anti-Hipertensivos/administração & dosagem , Aorta Torácica/fisiopatologia , Hipertensão/tratamento farmacológico , Hipertrofia Ventricular Esquerda/fisiopatologia , Imagem Cinética por Ressonância Magnética/métodos , Remodelação Vascular/fisiologia , Adulto , Idoso , Anlodipino/administração & dosagem , Aorta Torácica/efeitos dos fármacos , Aorta Torácica/patologia , Bendroflumetiazida/administração & dosagem , Relação Dose-Resposta a Droga , Quimioterapia Combinada , Hipertensão Essencial , Feminino , Seguimentos , Ventrículos do Coração/patologia , Ventrículos do Coração/fisiopatologia , Humanos , Hipertensão/complicações , Hipertensão/fisiopatologia , Hipertrofia Ventricular Esquerda/diagnóstico , Hipertrofia Ventricular Esquerda/etiologia , Imidazóis/administração & dosagem , Masculino , Pessoa de Meia-Idade , Simpatolíticos , Resultado do Tratamento , Valsartana/administração & dosagem , Remodelação Vascular/efeitos dos fármacos , Rigidez Vascular/efeitos dos fármacos
19.
J Cardiovasc Magn Reson ; 16: 86, 2014 Oct 28.
Artigo em Inglês | MEDLINE | ID: mdl-25356834

RESUMO

BACKGROUND: Intramyocardial hemorrhage (IMH) identified by cardiovascular magnetic resonance (CMR) is an established prognostic marker following acute myocardial infarction (AMI). Detection of IMH by T2-weighted or T2 star CMR can be limited by long breath hold times and sensitivity to artefacts, especially at 3T. We compared the image quality and diagnostic ability of susceptibility-weighted magnetic resonance imaging (SW MRI) with T2-weighted and T2 star CMR to detect IMH at 3T. METHODS: Forty-nine patients (42 males; mean age 58 years, range 35-76) underwent 3T cardiovascular magnetic resonance (CMR) 2 days following re-perfused AMI. T2-weighted, T2 star and SW MRI images were obtained. Signal and contrast measurements were compared between the three methods and diagnostic accuracy of SW MRI was assessed against T2w images by 2 independent, blinded observers. Image quality was rated on a 4-point scale from 1 (unusable) to 4 (excellent). RESULTS: Of 49 patients, IMH was detected in 20 (41%) by SW MRI, 21 (43%) by T2-weighted and 17 (34%) by T2 star imaging (p = ns). Compared to T2-weighted imaging, SW MRI had sensitivity of 93% and specificity of 86%. SW MRI had similar inter-observer reliability to T2-weighted imaging (κ = 0.90 and κ = 0.88 respectively); both had higher reliability than T2 star (κ = 0.53). Breath hold times were shorter for SW MRI (4 seconds vs. 16 seconds) with improved image quality rating (3.8 ± 0.4, 3.3 ± 1.0, 2.8 ± 1.1 respectively; p < 0.01). CONCLUSIONS: SW MRI is an accurate and reproducible way to detect IMH at 3T. The technique offers considerably shorter breath hold times than T2-weighted and T2 star imaging, and higher image quality scores.


Assuntos
Hemorragia/diagnóstico , Imagem Cinética por Ressonância Magnética/métodos , Infarto do Miocárdio/terapia , Traumatismo por Reperfusão Miocárdica/diagnóstico , Miocárdio/patologia , Intervenção Coronária Percutânea/efeitos adversos , Adulto , Idoso , Meios de Contraste , Feminino , Gadolínio DTPA , Hemorragia/etiologia , Hemorragia/patologia , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/diagnóstico , Traumatismo por Reperfusão Miocárdica/etiologia , Traumatismo por Reperfusão Miocárdica/patologia , Variações Dependentes do Observador , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Fatores de Tempo , Resultado do Tratamento
20.
J Cardiovasc Magn Reson ; 16: 34, 2014 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-24886614

RESUMO

BACKGROUND: Aberrant coronary arteries represent a diverse group of congenital disorders. Post-mortem studies reveal a high risk of exercise-related sudden cardiac death in those with an anomalous coronary artery originating from the opposite sinus of Valsalva (ACAOS) with an inter-arterial course. There is little documentation of lifetime history and long-term follow-up of patients with coronary artery anomalies. METHODS: Patients with anomalous coronary arteries undergoing cardiovascular magnetic resonance over a 15-year period were identified and classified by anatomy and course. Medical records were reviewed for major adverse cardiovascular events (MACE). Revascularisation or myocardial infarction counted only if occurring in the distribution of the anomalous artery. RESULTS: Consecutive patients with coronary artery anomalies were retrospectively identified (n = 172). Median follow-up time was 4.3 years (IQR 2.5-7.8, maximum 15.6). 116 patients had ACAOS of which 64 (55%) had an inter-arterial course (IAC) and 52 (45%) did not. During follow up 110 ACAOS patients were alive, 5 died and 1 lost to follow-up.ACAOS patients experienced 58 MACE events (5 cardiovascular deaths, 5 PCI, 24 CABG and 24 had myocardial infarction). 47 MACE events occurred in ACAOS with IAC and 11 in those without (p < 0.0001), the statistical difference driven by surgical revascularisation and myocardial infarction. CONCLUSIONS: In life, patients with an anomalous coronary artery originating from the opposite sinus of Valsalva taking an IAC have higher rates of both myocardial infarction and surgical revascularisation during long-term follow up, compared to those without IAC.


Assuntos
Anomalias dos Vasos Coronários/diagnóstico , Vasos Coronários/patologia , Imageamento por Ressonância Magnética , Seio Aórtico/anormalidades , Centros de Atenção Terciária , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Pré-Escolar , Ponte de Artéria Coronária , Anomalias dos Vasos Coronários/complicações , Anomalias dos Vasos Coronários/mortalidade , Anomalias dos Vasos Coronários/patologia , Anomalias dos Vasos Coronários/terapia , Inglaterra , Humanos , Lactente , Estimativa de Kaplan-Meier , Pessoa de Meia-Idade , Infarto do Miocárdio/etiologia , Infarto do Miocárdio/mortalidade , Infarto do Miocárdio/terapia , Intervenção Coronária Percutânea , Valor Preditivo dos Testes , Prognóstico , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA