Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Int J Cardiol ; 277: 173-177, 2019 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-30409733

RESUMO

BACKGROUND: A significant proportion of patients receiving CRT are non-responders. We evaluated the efficacy of Cardiac Contractility Modulation in subjects with reduced LVEF who, despite cardiac resynchronization therapy (CRT), continued to experience clinically significant symptoms. METHODS: This was a multi-center, open label, treatment-only, feasibility study of 17 CRT non-responders who received CCM therapy. Changes in NYHA class, ejection fraction (EF), Minnesota Living with Heart Failure Questionnaire (MLWHFQ) score, and exercise tolerance (6 minute walk test; 6MWT and peak VO2) were analyzed over 6 months. Mortality and hospitalization rates were determined. RESULTS: Patients (82% male) were 69.4 ±â€¯9.6 years of age with baseline EF = 22.8 ±â€¯6.5%. Among primary endpoints, peak VO2 increased 1.1 ±â€¯1.6 ml/kg/min (p = 0.03) and MLWHFQ improved (-16 ±â€¯16 points; p < 0.01). Mean NYHA class improved (-0.33 ±â€¯0.49; p = 0.02), 6MWT increased (52 ±â€¯60 m; p < 0.01), while EF trended up (2.9 ±â€¯5.8%; p = 0.08) at 6 months. During the 6-month follow-up period, there were 18 hospitalizations in 9 subjects and 2 patients died. CONCLUSIONS: Patients with heart failure and reduced ejection fraction who remain moderately to severely symptomatic despite use of CRT, may benefit from CCM therapy with improvement in quality of life and exercise tolerance. A larger prospective study in this population is warranted.


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca/tendências , Terapia de Ressincronização Cardíaca/métodos , Terapia de Ressincronização Cardíaca/tendências , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/terapia , Contração Miocárdica/fisiologia , Idoso , Estudos de Viabilidade , Feminino , Insuficiência Cardíaca/mortalidade , Humanos , Masculino , Pessoa de Meia-Idade , Mortalidade/tendências , Volume Sistólico/fisiologia , Resultado do Tratamento
2.
Herzschrittmacherther Elektrophysiol ; 28(1): 64-66, 2017 Mar.
Artigo em Alemão | MEDLINE | ID: mdl-28185079

RESUMO

We report the case of a 38-year-old man who was implanted a subcutaneous implantable cardioverter-defibrillator (S-ICD) and then performed a skydive from a height of 3000 m. During the jump, he lost consciousness due to ventricular fibrillation (VF). The S­ICD detected the VF properly and successfully shocked the arrhythmia. Our illustrative case emphasizes the S­ICD as an appropriate therapy in patient with life-threatening arrhythmias even under extreme conditions.


Assuntos
Aeronaves , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Inconsciência/prevenção & controle , Fibrilação Ventricular/diagnóstico , Fibrilação Ventricular/prevenção & controle , Adulto , Humanos , Masculino , Resultado do Tratamento , Inconsciência/diagnóstico , Inconsciência/etiologia , Fibrilação Ventricular/complicações
3.
Int J Cardiol ; 183: 76-81, 2015 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-25662055

RESUMO

AIMS: To analyze long-term efficacy and survival in patients with chronic heart failure treated with cardiac contractility modulation. METHODS: 81 patients implanted with a CCM device between 2004 and 2012 were included in this retrospective analysis. Changes in NYHA class, ejection fraction (EF), Minnesota Living with Heart Failure Questionnaire, NT-proBNP and peak VO2 were analyzed during a mean follow up of 34.2 ± 28 months (6-123 months). Observed mortality rate was compared with that predicted by the MAGGIC Score. RESULTS: Patients were 61 ± 12 years old with EF 23 ± 7%. Heart failure was due to ischemic (n=48, 59.3%) or idiopathic dilated (n=33, 40.7%) cardiomyopathy. EF increased from 23.1 ± 7.9 to 29.4 ± 8.6% (p<0.05), mean NT-proBNP decreased from 4395 ± 3818 to 2762 ± 3490 ng/l (p<0.05) and mean peak VO2 increased from 13.9 ± 3.3 to 14.6 ± 3.5 ml/kg/min (p=0.1). The overall clinical responder rate (at least 1 class improvement of NYHA within 6 months or last follow-up) was 74.1%. 21 (25.9%) patients died during follow up, 11 (52.4%) due to cardiac conditions and 10 (47.6%) due to non-cardiac conditions. Mortality rates at 1 and 3 years were 5.2% and 29.5% compared to mortality rates estimated from the MAGGIC risk score of 18.4% (p<0.001) and 40% (p=ns), respectively. Log-Rank analysis of all events through 3 years of follow-up, however, was significantly less than predicted (p=0.022). CONCLUSIONS: CCM therapy improved quality of life, exercise capacity, NYHA class, EF and NT-proBNP levels during long-term follow up. Mortality rates appeared to be lower than estimated from the MAGGIC score.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/terapia , Idoso , Feminino , Insuficiência Cardíaca/sangue , Humanos , Masculino , Pessoa de Meia-Idade , Peptídeo Natriurético Encefálico/sangue , Fragmentos de Peptídeos/sangue , Estudos Retrospectivos , Volume Sistólico/fisiologia , Inquéritos e Questionários , Resultado do Tratamento , Função Ventricular Esquerda/fisiologia
4.
Eur J Radiol ; 81(11): 3294-9, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22819132

RESUMO

OBJECTIVE: To prospectively evaluate the diagnostic accuracy of quantitative cardiac CT parameters alone and in combination with troponin I for the assessment of right ventricular dysfunction (RVD) and adverse clinical events in patients with acute pulmonary embolism (PE). MATERIALS AND RESULTS: This prospective study had institutional review board approval and was HIPAA compliant. In total 83 patients with confirmed PE underwent echocardiography and troponin I serum level measurements within 24 h. Three established cardiac CT measurements for the assessment of RVD were obtained (RV/LVaxial, RV/LV4-CH, and RV/LVvolume). CT measurements and troponin I serum levels were correlated with RVD found on echocardiography and adverse clinical events according to Management Strategies and Prognosis in Pulmonary Embolism Trial-3 (MAPPET-3 criteria. 31 of 83 patients with PE had RVD on echocardiography and 39 of 83 patients had adverse clinical events. A RV/LVvolume ratio>1.43 showed the highest area under the curve (AUC) (0.65) for the prediction of adverse clinical events when compared to RV/LVaxial, RV/LV4Ch and troponin I. The AUC for the detection of RVD of RV/LVaxial, RV/LV4Ch, RV/LVvolume, and troponin I were 0.86, 0.86, 0.92, and 0.69, respectively. Combination of RV/LVaxial, RV/LV4Ch, RV/LVvolume with troponin I increased the AUC to 0.87, 0.87 and 0.93, respectively. CONCLUSION: A combination of cardiac CT parameters and troponin I measurements improves the diagnostic accuracy for detecting RVD and predicting adverse clinical events if compared to either test alone.


Assuntos
Angiografia Coronária/métodos , Embolia Pulmonar/sangue , Embolia Pulmonar/diagnóstico , Tomografia Computadorizada por Raios X/métodos , Troponina I/sangue , Disfunção Ventricular Direita/sangue , Disfunção Ventricular Direita/diagnóstico , Adulto , Idoso , Biomarcadores/sangue , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA