1.
Radiol Manage ; 38(2): 23-30; quiz 32, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27172649

RESUMO

This article is a review of the literature on Lean and Lean Management Systems and how they have been implemented in healthcare organizations and particularly in radiology departments. The review focuses on the elements required for a successful implementation of Lean by applying the principles of a Lean Management System instead of a Lean tools-only approach. This review shares the successes and failures from healthcare organizations' efforts to improve the quality and safety of the services they provide. There are a limited number of healthcare organizations in the literature who have shared their experiences and additional research is necessary to determine whether a Lean Management System is a viable alternative to the current management structure in healthcare.


Assuntos
Serviço Hospitalar de Radiologia/normas , Gestão da Qualidade Total/organização & administração , Educação Continuada
2.
J Breast Imaging ; 4(1): 61-69, 2022 Jan 27.
Artigo em Inglês | MEDLINE | ID: mdl-38422417

RESUMO

To facilitate the delivery of accurate and timely care to patients in complex environments, process improvement methodologies such as Lean can be very effective. Lean is a quality improvement methodology that seeks to add value for patients and employees by continuously improving processes and eliminating waste. At our institution, Lean principles were applied to improve efficiency and minimize waste in the diagnostic breast imaging reading room. This paper describes how we applied Lean principles, including plan-do-study-act testing, level-loading (heijunka), and visual management, to level the workload of the diagnostic radiologists in our practice. Implementation of these principles to improve the diagnostic workflow in breast imaging is described along with examples from our practice, including challenges and future opportunities.

3.
J Nucl Cardiol ; 18(5): 840-6, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21748520

RESUMO

BACKGROUND: A novel ultra-fast solid-state cardiac camera (Discovery NM 530c, General Electric) allows much shorter acquisition times compared to standard dual-detector SPECT cameras. This design enables investigation of the potential for early myocardial perfusion imaging (MPI) following a rest injection of technetium-99m (Tc-99m) rather than the conventional 45-60 minute delay in image acquisition. METHODS: A total of 30 patients underwent MPI at rest using Tc-99m sestamibi (n = 9) or tetrofosmin (n = 21). A 12 minute image acquisition in list mode was performed immediately following isotope injection. Patients also underwent a conventional delayed image acquisition 60 minutes following the rest isotope injection (image acquisition over 4 minutes). The immediate 12 minute acquisition was divided into three 4-minute intervals for image reconstruction (0-4, 4-8, and 8-12 minutes). The perfusion images were interpreted by two experienced physicians who evaluated each study for overall image quality (good, acceptable, or unacceptable) and graded each image using the summed rest score (SRS) and the standard 17-segment, 5-point scale model. RESULTS: The images acquired in the 0-8 minute time interval were predominantly uninterpretable due to excessive blood pool uptake. The images acquired in the 8-12 minute time interval were interpretable and compared to the conventional images obtained at 60 minutes. Overall image quality was better on the 60 minute image (17 good, 13 acceptable) compared with 8-12 minute image (3 good, 25 acceptable, 2 unacceptable). Sixteen of the 30 patients had an improvement in overall image quality by at least one category using the 60 minute delayed image. Nine of the 30 patients (2 Tc-99m sestamibi; 7 Tc-99m tetrofosmin) had at least one uninterpretable myocardial segment due to liver and/or bowel overlapping the myocardium on the 8-12 minute images vs 1 patient (1 myocardial segment) with this problem on the 60 minute delayed images (P = .005). Uninterpretable segments (total of 16) on the 8-12 minute images were confined to the apex and inferior wall. The mean SRS of the interpretable 8-12 minute images (n = 21) was 3.2 (95% confidence intervals; 1.0, 5.4) compared to 1.6 (95% confidence intervals; 0, 3.3) on the 60 minute delayed images in those patients (P = .005). CONCLUSIONS: Overall image quality was better with fewer uninterpretable studies and a lower SRS on the rest images obtained at 60 minutes compared to early image acquisition (8-12 minutes following isotope injection). These findings do not support the routine use of early image acquisition with this new solid-state ultra-fast camera system.


Assuntos
Processamento de Imagem Assistida por Computador/normas , Imagem de Perfusão do Miocárdio/instrumentação , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Imagem de Perfusão do Miocárdio/normas , Compostos Organofosforados , Compostos de Organotecnécio , Tecnécio Tc 99m Sestamibi , Fatores de Tempo
4.
Qual Manag Health Care ; 22(4): 293-305, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24088878

RESUMO

We used the systems engineering technique of discrete event simulation modeling to assist in increasing patient access to positron emission tomographic examinations in the Department of Nuclear Medicine at Mayo Clinic, Rochester. The model was used to determine the best universal slot length to address the specific access challenges of a destination medical center such as Mayo Clinic. On the basis of the modeling, a new schedule was implemented in April 2012 and our before and after data analysis shows an increase of 2.4 scans per day. This was achieved without requiring additional resources or negatively affecting patient waiting, staff satisfaction (as evaluated by day length), or examination quality.


Assuntos
Agendamento de Consultas , Eficiência Organizacional , Acessibilidade aos Serviços de Saúde , Medicina Nuclear/métodos , Tomografia por Emissão de Pósitrons , Simulação por Computador , Humanos , Objetivos Organizacionais , Fatores de Tempo