Resultados 1 - 20 de 143
Filtrar
1.
J Vasc Interv Radiol ; 32(7): 941-949.e3, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33901695

RESUMO

PURPOSE: To investigate the magnitude of racial/ethnic differences in hospital mortality after transjugular intrahepatic portosystemic shunt (TIPS) creation for acute variceal bleeding and whether hospital care processes contribute to them. METHODS: Patients aged ≥18 years undergoing TIPS creation for acute variceal bleeding in the United States (n = 10,331) were identified from 10 years (2007-2016) available in the National Inpatient Sample. Hierarchical logistic regression was used to examine the relationship between patient race and inpatient mortality, controlling for disease severity, treatment utilization, and hospital characteristics. RESULTS: A total of 6,350 (62%) patients were White, 1,780 (17%) were Hispanic, and 482 (5%) were Black. A greater proportion of Black patients were admitted to urban teaching hospitals (Black, n = 409 (85%); Hispanic, n = 1,310 (74%); and White, n = 4,802 (76%); P < .001) and liver transplant centers (Black, n = 215 (45%); Hispanic, n = 401 (23%); and White, n = 2,267 (36%); P < .001). Being Black was strongly associated with mortality (Black, 32% vs non-Black, 15%; odds ratio, 3.0 [95% confidence interval, 1.6-5.8]; P = .001), as assessed using the risk-adjusted regression model. This racial disparity disappeared in a sensitivity analysis including only patients with a maximum Child-Pugh score of 13 (odds ratio 1.2 [95% confidence interval, 0.4-3.6]; P = .68), performed to compensate for the absence of Model for End-stage Liver Disease scores. Ethnoracial differences in access to teaching hospitals, liver transplant centers, first-line endoscopy, and transfusion did not significantly contribute (P > .05) to risk-adjusted mortality. CONCLUSIONS: Black patients have a 2-fold higher inpatient mortality than non-Black patients following TIPS creation for acute variceal bleeding, possibly related to greater disease severity before the procedure.


Assuntos
Doença Hepática Terminal , Varizes Esofágicas e Gástricas , Derivação Portossistêmica Transjugular Intra-Hepática , Adolescente , Adulto , Varizes Esofágicas e Gástricas/cirurgia , Hemorragia Gastrointestinal/cirurgia , Hospitais , Humanos , Derivação Portossistêmica Transjugular Intra-Hepática/efeitos adversos , Índice de Gravidade de Doença , Resultado do Tratamento , Estados Unidos
2.
J Vasc Interv Radiol ; 32(1): 23-32.e1, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33189539

RESUMO

PURPOSE: To demonstrate a stronger correlation and agreement of yttrium-90 (90Y) positron emission tomography (PET)/computed tomography (CT) measurements with explant liver tumor dosing compared with the standard model (SM) for radioembolization. MATERIALS AND METHODS: Hepatic VX2 tumors were implanted into New Zealand white rabbits, with growth confirmed by 7 T magnetic resonance imaging. Seventeen VX2 rabbits provided 33 analyzed tumors. Treatment volumes were calculated from manually drawn volumes of interest (VOI) with three-dimensional surface renderings. Radioembolization was performed with glass 90Y microspheres. PET/CT imaging was completed with scatter and attenuation correction. Three-dimensional ellipsoid VOI were drawn to encompass tumors on fused images. Tumors and livers were then explanted for inductively coupled plasma (ICP)-optical emission spectroscopy (OES) analysis of microsphere content. 90Y PET/CT and SM measurements were compared with reference standard ICP-OES measurements of tumor dosing with Pearson correlation and Bland-Altman analyses for agreement testing with and without adjustment for tumor necrosis. RESULTS: The median infused activity was 33.3 MBq (range, 5.9-152.9). Tumor dose was significantly correlated with 90Y PET/CT measurements (r = 0.903, P < .001) and SM estimates (r = 0.607, P < .001). Bland-Altman analyses showed that the SM tended to underestimate the tumor dosing by a mean of -8.5 Gy (CI, -26.3-9.3), and the degree of underestimation increased to a mean of -18.3 Gy (CI, -38.5-1.9) after the adjustment for tumor necrosis. CONCLUSIONS: 90Y PET/CT estimates were strongly correlated and had better agreement with reference measurements of tumor dosing than SM estimates.


Assuntos
Embolização Terapêutica , Neoplasias Hepáticas Experimentais/diagnóstico por imagem , Neoplasias Hepáticas Experimentais/radioterapia , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Doses de Radiação , Compostos Radiofarmacêuticos/administração & dosagem , Radioisótopos de Ítrio/administração & dosagem , Animais , Feminino , Necrose , Valor Preditivo dos Testes , Coelhos , Interpretação de Imagem Radiográfica Assistida por Computador , Carga Tumoral
3.
Radiology ; 297(2): 474-481, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32897162

RESUMO

Background Dialysis maintenance interventions account for billions of dollars in U.S. Medicare spending and are performed by multiple medical specialties. Whether Medicare costs differ by physician specialty is, to the knowledge of the authors, not known. Purpose To assess patency-adjusted costs of endovascular dialysis access maintenance by physician specialty. Materials and Methods In this retrospective longitudinal cohort study, patients who were beneficiaries of Medicare undergoing their first arteriovenous access placement in 2009 were identified by using billing codes in the 5% Limited Data Set. By tracking their utilization data through 2014, postintervention primary patency and aggregate payments associated with maintenance interventions were calculated. Unadjusted payments per year of access patency gain were compared across physician specialty. A general linear mixed-effects model adjusted for covariates was used, as follows: patient characteristics, access type (fistula vs graft), clinical severity, type of intervention (angioplasty, stent, thrombolysis), clinical location (hospital outpatient vs office-based laboratory), and resource utilization (operating room use, anesthesia use). Results First arteriovenous access was performed in 1479 beneficiaries (mean age, 63 years ± 15 [standard deviation]; 820 men) in 2009. Through 2014, 8166 maintenance interventions were performed in this cohort. Unadjusted mean Medicare payments for each incremental year of patency were as follows: $71 000 for radiologists, $89 000 for nephrologists, and $174 000 for surgeons. Billing for operating room (41.8% [792 of 1895], surgery; 10.2% [277 of 2709], nephrology; and 31.1% [1108 of 3562], radiology) and anesthesia (19.9% [377 of 1895], surgery; 2.6% [70 of 2709], nephrology; 4.7% [170 of 3562], radiology) varied by specialty and accounted for 407% and 132% higher payments, respectively. After adjusting for clinical severity and location, type of intervention, and resource utilization, nephrologists and surgeons had 59% (95% confidence interval: 44%, 73%; P < .001) and 57% (95% confidence interval: 43%, 72%; P < .001) higher payments, respectively, for the same patency gain compared with radiologists. Operating room use and anesthesia services were major drivers of higher cost, with 407% (95% confidence interval: 374%, 443%; P < .001) and 132% (95% confidence interval: 116%, 150%; P < .001) higher costs, respectively. Conclusion Patency-adjusted payments for hemodialysis access maintenance differed by physician specialty, driven partly by discrepant rates of billing for operating room and anesthesia use. © RSNA, 2020 Online supplemental material is available for this article. See also the editorial by White in this issue.


Assuntos
Medicare/economia , Medicina , Diálise Renal/economia , Custos e Análise de Custo , Feminino , Humanos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Estados Unidos
4.
J Vasc Interv Radiol ; 31(4): 614-621.e2, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32127322

RESUMO

PURPOSE: To describe national trends in peripheral endovascular interventions by physician specialty, anatomic segment of disease, and clinical location of service. MATERIALS AND METHODS: Current Procedural Terminology codes were used to identify claims for peripheral vascular interventions (PVIs) in 2011-2017 Physician Supplier Procedure Summary master files, which contain 100% Part B Medicare billing. Market share was defined as enrollment-adjusted proportion of billed PVI services for each specialty. Annual volume of billed services was additionally evaluated by clinical location (inpatient, outpatient, office-based laboratories) and anatomic segment of disease (iliac, femoral/popliteal, infrapopliteal). RESULTS: Aggregate PVI claims increased 31.3%, from 227,091 in 2011 to 298,127 in 2017. Annual market share remained relatively stable for all specialties: surgery, 48.3%-49.6%; cardiology, 37.2%-35.1%; radiology, 12.8%-13.3%. Accounting for Medicare enrollment, the volume of iliac interventions decreased by 18% over the study period, while femoral/popliteal interventions increased modestly (+7.5%) and infrapopliteal interventions increased (+46%). The greatest proportional increase in infrapopliteal claims occurred among radiologists (surgeons +40.4%, cardiologists +32.1%, radiologists +106.6%). Adjusting for enrollment, claims from office-based laboratories increased substantially (+305.7%), while hospital-based billing decreased (inpatient -25.7%, outpatient -12.9%). Office-based laboratory utilization increased dramatically with all specialties (surgery +331.8%, cardiology +256.0%, radiology +475.7%). CONCLUSIONS: Utilization of PVIs continues to increase, while specialty market shares have stabilized since 2011, leaving surgeons and cardiologists as the major providers of endovascular peripheral artery disease care. The greatest relative increases are occurring in infrapopliteal interventions and office-based laboratory procedures, where radiologist involvement has increased dramatically.


Assuntos
Procedimentos Endovasculares/tendências , Extremidade Inferior/irrigação sanguínea , Medicare/tendências , Doença Arterial Periférica/terapia , Padrões de Prática Médica/tendências , Especialização/tendências , Demandas Administrativas em Assistência à Saúde , Assistência Ambulatorial/tendências , Procedimentos Cirúrgicos Ambulatórios/tendências , Cardiologistas/tendências , Bases de Dados Factuais , Hospitalização/tendências , Humanos , Doença Arterial Periférica/diagnóstico por imagem , Doença Arterial Periférica/fisiopatologia , Radiologistas/tendências , Cirurgiões/tendências , Fatores de Tempo , Estados Unidos
5.
AJR Am J Roentgenol ; 214(1): 149-155, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31670588

RESUMO

OBJECTIVE. The objective of this study was to assess clinical practice characteristics of radiologists on the basis of American Board of Radiology (ABR) interventional radiology (IR) certification status. MATERIALS AND METHODS. Medicare-participating radiologists were linked with ABR diplomates using the ABR's public search engine. Radiologists with an interventional radiology/diagnostic radiology (IR/DR) certificate (offered since 2017) were deemed currently IR-certified (n = 2840), and those assigned a vascular and interventional radiology subspecialty certificate (now defunct by the ABR) were deemed previously IR-certified (n = 900). Physician characteristics were obtained from Centers for Medicare & Medicaid Services (CMS) data. RESULTS. Overall, the mean percentage work effort in IR was higher for radiologists currently IR-certified than it was for radiologists who were previously IR-certified (65.9% vs 30.6%). Although 41.2% of currently IR-certified diplomates had more than 90% IR work effort, 35.7% had 50% or less IR work effort. Radiologists with current IR certification versus those with previous IR certification were more likely to be in an academic practice (25.1% vs 8.4%), a larger practice (in a practice with ≥ 100 members, 41.2% vs 22.4%), and earlier career stages (≤ 20 years in practice, 46.5% vs 0.6%). Of the 10 services most commonly billed by currently versus previously IR-certified radiologists, two and zero, respectively, were invasive procedures. Of identified CMS-participating radiologists with more than 50% IR effort, 27.2% (727/2670) were neither previously nor currently IR-certified. CONCLUSION. Although radiologists maintaining IR certification have higher IR work effort than those whose IR certification has lapsed, they are heterogeneous with overall sizable noninvasive diagnostic imaging practices. Approximately one-quarter of radiologists with predominant IR practices have never obtained IR certification. Because current IR/DR maintenance of certification testing exclusively addresses IR practice, attention is warranted to ensure certification is relevant to all IR diplomates.


Assuntos
Padrões de Prática Médica , Radiologia Intervencionista/normas , Conselhos de Especialidade Profissional , Estudos Retrospectivos , Estados Unidos
6.
AJR Am J Roentgenol ; 215(4): 790-794, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32755356

RESUMO

OBJECTIVE. Utilization of retrievable inferior vena cava filters (rIVCFs) has come under increased scrutiny because of historically high rates of placement, generalized lack of retrieval when the inferior vena cava filter (IVCF) is no longer indicated, and reports of device-related complications. These events have led to an increased interest in IVCF retrieval, including the development of advanced endovascular retrieval techniques and the proliferation of specialized clinical practices for rIVCFs. We aim to describe the indications for IVCF retrieval, patient selection, procedural planning, and procedural complications and management. CONCLUSION. IVCFs continue to have a role in the prevention of pulmonary embolism in select patients. Rising awareness of device-related complications paired with historically low retrieval rates has prompted renewed emphasis and interest in filter retrieval. Diligent follow-up and procedural planning permit prompt and safe filter retrieval.


Assuntos
Remoção de Dispositivo/efeitos adversos , Seleção de Pacientes , Complicações Pós-Operatórias/etiologia , Embolia Pulmonar/prevenção & controle , Filtros de Veia Cava/efeitos adversos , Procedimentos Endovasculares , Humanos , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/terapia
7.
J Vasc Interv Radiol ; 29(4): 476-481.e1, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29373244

RESUMO

PURPOSE: To determine whether utilization and outcomes of dialysis access maintenance interventions vary by patient race or sex. MATERIALS AND METHODS: Data for this retrospective cohort study of first-time arteriovenous (AV) access recipients were drawn from a 5% sample of Medicare beneficiaries, containing claims from all clinical settings (2009-2014) in 2,693 patients who received their first AV fistula/graft in 2009. Maintenance interventions-angiography, angioplasty, thrombolysis, stent placement, and venous embolization-were identified by corresponding Current Procedural Terminology codes. Outcomes of primary patency (PP), postinterventional primary patency (PIPP), and postinterventional secondary patency (PISP) were calculated with utilization records. Associations between demographic data and patency times were evaluated by a multivariate survival approach, controlling for baseline differences in patient age, comorbid disease, type of dialysis access, and interventionist specialty. RESULTS: AV grafts (AVGs) were created with greater frequency in women (32% vs 23% in men; P < .001) and minority patients (39% in black, 32% in Hispanic, and 29% in Asian patients vs 21% in white patients; P < .001). Women were at greater hazards for loss of PP (hazard ratio [HR], 1.49; 95% confidence interval [CI], 1.09-2.14) and PIPP (HR, 1.42; 95% CI, 1.01-2.00). Black patients were at greater hazards for loss of PP (HR, 1.37; 95% CI, 1.23-1.54) and PISP (HR, 1.29; 95% CI, 1.01-1.65). AVG creation predisposed patients to patency loss in all models (P < .001). CONCLUSIONS: Dialysis access patency rates are lower for women and black patients. More frequent primary AVG creation in women and minority patients additionally predisposes these patients to patency loss.


Assuntos
Derivação Arteriovenosa Cirúrgica , Oclusão de Enxerto Vascular/etnologia , Oclusão de Enxerto Vascular/prevenção & controle , Diálise Renal , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Medicare , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores Sexuais , Resultado do Tratamento , Estados Unidos , Grau de Desobstrução Vascular
8.
AJR Am J Roentgenol ; 211(3): 672-676, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-30016144

RESUMO

OBJECTIVE: Pulmonary embolism (PE) is associated with a higher mortality rate in patients with congestive heart failure (CHF) than in those without heart failure. The purpose of this study was to evaluate if inferior vena cava (IVC) filter placement provides any mortality benefit in patients admitted with CHF and PE. MATERIALS AND METHODS: The 2005-2014 Nationwide Inpatient Sample (NIS) was used for this study. Adults (≥ 18 years old) with PE were identified using International Classification of Diseases, 9th revision, Clinical Modification (ICD-9-CM) diagnosis codes. Patients with CHF were identified using the Elixhauser comorbidity variable (CM_CHF) in the NIS database. IVC filter placement was identified using the ICD-9-CM procedure code 38.7 (interruption of the vena cava). A multivariate logistic regression model was used to determine the association of IVC filter placement with in-hospital mortality. The model was adjusted for demographics, hospital characteristics, comorbidities, and PE severity indexes (pressor dependence, mechanical ventilation, nonseptic shock, and use of thrombolytic therapy). RESULTS: During the study years, 425,877 patients with a comorbidity of CHF were hospitalized with PE (44% male; mean age, 71.5 years old). Of them, 67,237 patients (15.8%) received an IVC filter during the admission, and 50,338 (11.8%) died during the hospital stay. The all-cause in-hospital mortality rate among patients who received an IVC filter was 9.7% (6541 of 67,237 patients) compared with 12.2% (43,796 of 358,638 patients) among those without an IVC filter (p < 0.001), with an absolute risk reduction of 2.5%. The multivariate adjusted hazard ratio of in-hospital mortality associated with IVC filter placement was 0.535 (95% CI, 0.518-0.551; p < 0.001). CONCLUSION: A lower all-cause mortality rate was observed in patients with CHF and PE who received an IVC filter while hospitalized. In the absence of data from randomized controlled trials, this study suggests that IVC filters could help prevent in-hospital death among patients admitted with PE and CHF.


Assuntos
Insuficiência Cardíaca/mortalidade , Embolia Pulmonar/mortalidade , Filtros de Veia Cava , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Coortes , Feminino , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/terapia , Mortalidade Hospitalar , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Embolia Pulmonar/etiologia , Embolia Pulmonar/terapia , Taxa de Sobrevida , Resultado do Tratamento , Adulto Jovem
9.
Pediatr Radiol ; 48(2): 253-257, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-29119240

RESUMO

BACKGROUND: Inferior vena cava (IVC) filter placement in children has been described in literature, but there is variability with regard to their indications. No nationally representative study has been done to compare practice patterns of filter placements at adult and children's hospitals. OBJECTIVE: To perform a nationally representative comparison of IVC filter placement practices in children at adult and children's hospitals. MATERIALS AND METHODS: The 2012 Kids' Inpatient Database was searched for IVC filter placements in children <18 years of age. Using the International Classification of Diseases, 9th Revision (ICD-9) code for filter insertion (38.7), IVC filter placements were identified. A small number of children with congenital cardiovascular anomalies codes were excluded to improve specificity of the code used to identify filter placement. Filter placements were further classified by patient demographics, hospital type (children's and adult), United States geographic region, urban/rural location, and teaching status. Statistical significance of differences between children's or adult hospitals was determined using the Wilcoxon rank sum test. RESULTS: A total of 618 IVC filter placements were identified in children <18 years (367 males, 251 females, age range: 5-18 years) during 2012. The majority of placements occurred in adult hospitals (573/618, 92.7%). Significantly more filters were placed in the setting of venous thromboembolism in children's hospitals (40/44, 90%) compared to adult hospitals (246/573, 43%) (P<0.001). Prophylactic filters comprised 327/573 (57%) at adult hospitals, with trauma being the most common indication (301/327, 92%). The mean length of stay for patients receiving filters was 24.5 days in children's hospitals and 18.4 days in adult hospitals. CONCLUSION: The majority of IVC filters in children are placed in adult hospital settings. Children's hospitals are more likely to place therapeutic filters for venous thromboembolism, compared to adult hospitals where the prophylactic setting of trauma predominates.


Assuntos
Padrões de Prática Médica/estatística & dados numéricos , Embolia Pulmonar/prevenção & controle , Filtros de Veia Cava , Adolescente , Criança , Pré-Escolar , Bases de Dados Factuais , Feminino , Hospitais Pediátricos , Humanos , Masculino , Fatores de Risco , Estados Unidos
11.
Radiographics ; 37(4): 1236-1245, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28696849

RESUMO

Use of retrievable inferior vena cava filters (RIVCFs) has grown exponentially since their introduction into clinical practice, but many of these devices are not retrieved. Some are not retrieved due to poor clinical follow-up, but other devices remain in situ for extended periods because they present significant technical challenges during retrieval. Because of these and other factors, many of these devices were thus left in place permanently. However, recent data have placed a renewed emphasis on device retrieval due to increased risk of RIVCF-related complications, which are positively correlated with filter dwell time. Development of advanced filter retrieval techniques has had a significant impact on the removal of embedded RIVCFs, permitting retrieval of the majority of devices. The purpose of this article is to present an imaging and data review of the dominant device-related factors that complicate RIVCF retrieval and to describe the relevant advanced retrieval techniques to manage these factors. RIVCF imaging is frequently encountered in daily clinical practice via various imaging modalities. Therefore, diagnostic radiologists can play a vital role in identifying filter-related issues. Familiarity with the context for managing these issues in the interventional suite is essential for improving triage and care of patients with RIVCFs. © RSNA, 2017.


Assuntos
Remoção de Dispositivo/métodos , Diagnóstico por Imagem , Filtros de Veia Cava/efeitos adversos , Veia Cava Inferior/diagnóstico por imagem , Humanos , Fatores de Tempo
12.
Ann Vasc Surg ; 42: 64-70, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28288891

RESUMO

BACKGROUND: Compared to permanent inferior vena cava (IVC) filters, higher complication rates occur with long-term use of temporary IVC filters. We aimed to identify patient clinical factors at the time of placement that could predict failure to remove a temporary IVC filter. METHODS: A retrospective review was performed of both vascular surgery and interventional radiology prospective databases between December 2008 and December 2013. We analyzed a total number of 1,024 consecutive, temporary IVC filters stratified by whether retrieval was attempted or made permanent. Univariate, multivariate, and prediction modeling analyses with internal validation were performed on abstracted data, which included risk factors, treatment modalities, and indications for IVC filter placement. RESULTS: Of 1,024 temporary IVC filters, removal was attempted in 60% and no attempt at removal (kept permanent) in 40%. Of the 619 with attempted removal, the overall successful retrieval rate was 95%. The majority of filters were not attempted to be removed because of persistent filter indications (360 cases). Risk factors associated with IVC filter permanence included male sex, older age, history, or indication of venous thromboembolism (VTE) with inability to anticoagulate, malignancy, and neurologic condition. Risk factors most predictive of permanence in the multivariate model were malignancy (odds ratio [OR]: 3.0, P < 0.001) or neurologic disorder (OR: 2.69, P = 0.0005). Validation revealed our model had a sensitivity of 60.4% and specificity of 69.9%. CONCLUSIONS: Our study shows that patients who are more likely to have a temporary IVC filter kept permanent are more likely to be older males with a history of malignancy, neurologic condition, or VTE. These factors are also predictive of permanence and can be used in our predictive model to provide insight into the significant preoperative risk factors that should play into the decision-making process.


Assuntos
Remoção de Dispositivo , Implantação de Prótese/instrumentação , Filtros de Veia Cava , Tromboembolia Venosa/terapia , Adulto , Fatores Etários , Idoso , Chicago/epidemiologia , Bases de Dados Factuais , Remoção de Dispositivo/efeitos adversos , Humanos , Modelos Logísticos , Pessoa de Meia-Idade , Análise Multivariada , Neoplasias/epidemiologia , Doenças do Sistema Nervoso/epidemiologia , Razão de Chances , Padrões de Prática Médica , Implantação de Prótese/efeitos adversos , Estudos Retrospectivos , Fatores de Risco , Fatores Sexuais , Fatores de Tempo , Resultado do Tratamento , Tromboembolia Venosa/sangue , Tromboembolia Venosa/epidemiologia
13.
J Vasc Interv Radiol ; 27(6): 838-45, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26965361

RESUMO

PURPOSE: To elucidate trends in transjugular intrahepatic portosystemic shunt (TIPS) use and outcomes over the course of a decade, including predictors of inpatient mortality and extended length of hospital stay. MATERIALS AND METHODS: The Nationwide Inpatient Sample was interrogated for the most recent 10 years available: 2003-2012. TIPS procedures and associated diagnoses were identified via International Classification of Diseases (version 9) codes, with the latter categorized into primary diagnoses in a hierarchy of disease severity. Linear regression analysis was used to determine trends of TIPS use and outcomes over time. Independent predictors of mortality and extended length of stay were determined by logistic regression. RESULTS: A total of 55,145 TIPS procedures were captured during the study period. Annual procedural volume did not change significantly (5,979 in 2003, 5,880 in 2012). The majority of TIPSs were created for ascites and/or varices (84%). Inpatient mortality (12.5% in 2003, 10.6% in 2012; P < .05) decreased but varied considerably by diagnosis (from 3.7% to 59.3%), with a disparity between bleeding and nonbleeding varices (18.7% vs 3.8%; P < .01). Multivariate predictors of mortality (P < .001 for all) included primary diagnoses (bleeding varices, hepatorenal and abdominal compartment syndromes), patient characteristics (age > 80 y, black race), and sequelae of advanced cirrhosis (comorbid hepatocellular carcinoma, spontaneous bacterial peritonitis, encephalopathy, and coagulopathy). CONCLUSIONS: National TIPS inpatient mortality has decreased since 2003 while procedural volume has not changed. Postprocedural outcome is a function of patient demographic and socioeconomic factors and associated diagnoses. Independent predictors of poor outcome identified in this large national population study may aid clinicians in better assessing preprocedural risk.


Assuntos
Ascite/cirurgia , Varizes Esofágicas e Gástricas/cirurgia , Hipertensão Portal/cirurgia , Derivação Portossistêmica Transjugular Intra-Hepática/tendências , Padrões de Prática Médica/tendências , Adulto , Idoso , Idoso de 80 Anos ou mais , Ascite/diagnóstico , Ascite/mortalidade , Comorbidade , Bases de Dados Factuais , Varizes Esofágicas e Gástricas/diagnóstico , Varizes Esofágicas e Gástricas/mortalidade , Feminino , Mortalidade Hospitalar/tendências , Humanos , Hipertensão Portal/diagnóstico , Hipertensão Portal/mortalidade , Tempo de Internação/tendências , Modelos Lineares , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Derivação Portossistêmica Transjugular Intra-Hepática/efeitos adversos , Derivação Portossistêmica Transjugular Intra-Hepática/mortalidade , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Estados Unidos
14.
J Vasc Interv Radiol ; 27(8): 1140-7, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26852944

RESUMO

PURPOSE: To evaluate transjugular intrahepatic portosystemic shunt (TIPS) outcomes and procedure metrics with the use of three different image guidance techniques for portal vein (PV) access during TIPS creation. MATERIALS AND METHODS: A retrospective review of consecutive patients who underwent TIPS procedures for a range of indications during a 28-month study period identified a population of 68 patients. This was stratified by PV access techniques: fluoroscopic guidance with or without portography (n = 26), PV marker wire guidance (n = 18), or intravascular ultrasound (US) guidance (n = 24). Procedural outcomes and procedural metrics, including radiation exposure, contrast agent volume used, procedure duration, and PV access time, were analyzed. RESULTS: No differences in demographic or procedural characteristics were found among the three groups. Technical success, technical success of the primary planned approach, hemodynamic success, portosystemic gradient, and procedure-related complications were not significantly different among groups. Fluoroscopy time (P = .003), air kerma (P = .01), contrast agent volume (P = .003), and total procedural time (P = .02) were reduced with intravascular US guidance compared with fluoroscopic guidance. Fluoroscopy time (P = .01) and contrast agent volume (P = .02) were reduced with intravascular US guidance compared with marker wire guidance. CONCLUSIONS: Intravascular US guidance of PV access during TIPS creation not only facilitates successful TIPS creation in patients with challenging anatomy, as suggested by previous investigations, but also reduces important procedure metrics including radiation exposure, contrast agent volume, and overall procedure duration compared with fluoroscopically guided TIPS creation.


Assuntos
Hipertensão Portal/cirurgia , Veia Porta/cirurgia , Derivação Portossistêmica Transjugular Intra-Hepática , Radiografia Intervencionista , Ultrassonografia de Intervenção , Adolescente , Adulto , Idoso , Pontos de Referência Anatômicos , Dióxido de Carbono/administração & dosagem , Meios de Contraste/administração & dosagem , Feminino , Fluoroscopia , Humanos , Hipertensão Portal/diagnóstico por imagem , Hipertensão Portal/etiologia , Hipertensão Portal/fisiopatologia , Cirrose Hepática/complicações , Cirrose Hepática/diagnóstico , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Pressão na Veia Porta , Veia Porta/diagnóstico por imagem , Veia Porta/fisiopatologia , Derivação Portossistêmica Transjugular Intra-Hepática/efeitos adversos , Portografia , Doses de Radiação , Exposição à Radiação , Radiografia Intervencionista/efeitos adversos , Radiografia Intervencionista/métodos , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento , Ultrassonografia de Intervenção/efeitos adversos , Adulto Jovem
15.
J Vasc Interv Radiol ; 26(6): 865-9, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25791334

RESUMO

PURPOSE: To compare the retrievability of 2 potentially retrievable inferior vena cava filter devices. MATERIALS AND METHODS: A retrospective, institutional review board-approved study of Celect (Cook, Inc, Bloomington, Indiana) and Option (Rex Medical, Conshohocken, Pennsylvania) filters was conducted over a 33-month period at a single institution. Fluoroscopy time, significant filter tilt, use of adjunctive retrieval technique, and strut perforation in the inferior vena cava were recorded on retrieval. Fisher exact test and Mann-Whitney-Wilcoxon test were used for comparison. RESULTS: There were 99 Celect and 86 Option filters deployed. After an average of 2.09 months (range, 0.3-7.6 mo) and 1.94 months (range, 0.47-9.13 mo), respectively, 59% (n = 58) of patients with Celect filters and 74.7% (n = 65) of patients with Option filters presented for filter retrieval. Retrieval failure rates were 3.4% for Celect filters versus 7.7% for Option filters (P = .45). Median fluoroscopy retrieval times were 4.25 minutes for Celect filters versus 6 minutes for Option filters (P = .006). Adjunctive retrieval techniques were used in 5.4% of Celect filter retrievals versus 18.3% of Option filter retrievals (P = .045). The incidence of significant tilting was 8.9% for Celect filters versus 16.7% for Option filters (P = .27). The incidence of strut perforation was 43% for Celect filters versus 0% for Option filters (P < .0001). CONCLUSIONS: Retrieval rates for the Celect and Option filters were not significantly different. However, retrieval of the Option filter required a significantly increased amount of fluoroscopy time compared with the Celect filter, and there was a significantly greater usage of adjunctive retrieval techniques for the Option filter. The Celect filter had a significantly higher rate of strut perforation.


Assuntos
Remoção de Dispositivo/métodos , Procedimentos Endovasculares/métodos , Filtros de Veia Cava , Veia Cava Inferior , Adulto , Idoso , Idoso de 80 Anos ou mais , Chicago , Remoção de Dispositivo/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Flebografia , Desenho de Prótese , Doses de Radiação , Radiografia Intervencionista , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento , Lesões do Sistema Vascular/diagnóstico , Lesões do Sistema Vascular/etiologia , Filtros de Veia Cava/efeitos adversos , Veia Cava Inferior/diagnóstico por imagem , Veia Cava Inferior/lesões , Adulto Jovem
17.
Radiology ; 272(2): 587-97, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24678859

RESUMO

PURPOSE: To investigate the predictive value of transcatheter intraarterial perfusion (TRIP) magnetic resonance (MR) imaging-measured tumor perfusion changes during transarterial chemoembolization on transplant-free survival (TFS) in patients with unresectable hepatocellular carcinoma (HCC). MATERIALS AND METHODS: This HIPAA-compliant prospective study was approved by the institutional review board. Written informed consent was obtained from all patients. Fifty-one consecutive adult patients with surgically unresectable single or multifocal measurable HCC and adequate laboratory parameters who underwent chemoembolization in a combined MR imaging-interventional radiology suite between February 2006 and June 2010 were studied. Tumor perfusion changes during chemoembolization were measured by using TRIP MR imaging with area under the time-signal intensity curve calculation. The end point of the study was TFS. The authors assessed the correlation between the percentage perfusion reduction in the tumor during chemoembolization and TFS by using univariate and multivariate analyses. RESULTS: Fifty patients (mean age, 61 years; 39 men aged 42-87 years [mean age, 61 years] and 11 women aged 49-83 years [mean age, 62 years]) were eligible for the analysis. Patients with 35%-85% intraprocedural tumor area under the time-signal intensity curve reduction (n = 32) showed significantly improved median TFS compared with patients with an area under the time-signal intensity curve reduction outside this range (n = 18) (16.6 months [95% confidence interval: 11.2, 22.0 months] vs 9.3 months [95% confidence interval: 6.6, 12.0 months], respectively; P = .046; hazard ratio: 0.46; 95% confidence interval: 0.21, 1.00). The cumulative TFS rates in the 35%-85% and less than 35% or more than 85% perfusion reduction groups at 1, 2, and 5 years after chemoembolization were 66.4%, 42.2%, and 28.2% versus 33.8%, 16.9%, and 0%, respectively. CONCLUSION: The study shows evidence of an association between intraprocedural tumor perfusion reduction during chemoembolization and TFS and suggests the utility of TRIP MR imaging- measured tumor perfusion reduction as an intraprocedural imaging biomarker during chemoembolization.


Assuntos
Carcinoma Hepatocelular/terapia , Quimioembolização Terapêutica/métodos , Neoplasias Hepáticas/terapia , Angiografia por Ressonância Magnética/métodos , Imagem por Ressonância Magnética Intervencionista , Adulto , Idoso , Idoso de 80 Anos ou mais , Angiografia Digital , Antineoplásicos/administração & dosagem , Biomarcadores , Biópsia , Meios de Contraste/administração & dosagem , Feminino , Gadolínio DTPA/administração & dosagem , Humanos , Testes de Função Hepática , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Taxa de Sobrevida , Resultado do Tratamento , Carga Tumoral
18.
Semin Thromb Hemost ; 40(3): 401-6, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24610401

RESUMO

Many studies have supported the efficacy of inferior vena cava filters (IVCF) in the setting of venous thromboembolic disease, particularly in oncologic patients who are at increased risk. The advent of retrievable IVCF designs has prompted dramatically expanded use for patients with widely accepted indications but also disproportionately so in patients with so-called extended indications. At the same time, an alarming increase in filter-related complications has been reported both in the literature and through regulatory agencies, leading to government agency-issued warnings. The synergistic effect of these two interconnected phenomena is explained through a careful review of the evolution of IVCF device design. Critical differences exist when comparing retrievable IVCF and permanent IVCF. IVCF utilization can be optimized by prospectively identifying which patients are best served by a specific IVCF device. Careful follow-up strategies are also needed to ensure that all IVCFs are removed as soon as they are no longer needed. Finally, adjunctive techniques for removing "difficult" filters help maximize the number of IVCF removed and minimize IVCF left implanted needlessly.


Assuntos
Neoplasias/terapia , Filtros de Veia Cava/normas , Humanos , Neoplasias/sangue , Tromboembolia Venosa/prevenção & controle
19.
Eur J Nucl Med Mol Imaging ; 41(3): 486-93, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24114004

RESUMO

PURPOSE: To validate our initial pilot study and confirm sustained safety and tumor response of extended-shelf-life (90)Y glass microspheres. We hypothesized that for the same planned tissue dose, the increase in number of glass microspheres (decayed to the second week of their allowable shelf-life) administered for the same absorbed dose would result in better tumor distribution of the microspheres without causing additional adverse events. METHODS: Between June 2007 and January 2010, 134 patients underwent radioembolization with extended-shelf-life (90)Y glass microspheres; data from 84 new patients were combined with data from our 50-patient pilot study cohort. Baseline and follow-up imaging and laboratory data were obtained 1 and 3 months after therapy and every 3 months thereafter. Clinical and biochemical toxicities were prospectively captured and categorized according to the Common Terminology Criteria. Response in the index lesion was assessed using WHO and EASL guidelines. RESULTS: The mean delivered radiation dose was 123 Gy to the target liver tissue. The mean increase in number of microspheres with this approach compared to standard (90)Y glass microsphere dosimetry was 103%, corresponding to an increase from 3.84 to 7.78 million microspheres. Clinical toxicities included fatigue (89 patients, 66%), abdominal pain (49 patients, 36.6%), and nausea/vomiting (25 patients, 18.7%). Grade 3/4 bilirubin toxicity was seen in three patients (2%). Two (1%) of the initial 50-patient cohort showed gastroduodenal ulcers; gastroduodenal ulcers were not seen in any of the subsequent 84 patients. According to WHO and EASL guidelines, response rates were 48% and 57%, respectively, and 21% demonstrated a complete EASL response. CONCLUSION: This study showed sustained safety and efficacy of extended-shelf-life (90)Y glass microspheres in a larger, 134-patient cohort. The increase in number of microspheres administered theoretically resulted in better tumor distribution of the microspheres without an increase in adverse events.


Assuntos
Neoplasias dos Ductos Biliares/radioterapia , Carcinoma Hepatocelular/radioterapia , Colangiocarcinoma/radioterapia , Neoplasias Hepáticas/radioterapia , Microesferas , Compostos Radiofarmacêuticos/efeitos adversos , Radioisótopos de Ítrio/efeitos adversos , Idoso , Estabilidade de Medicamentos , Feminino , Seguimentos , Vidro , Humanos , Masculino , Pessoa de Meia-Idade , Compostos Radiofarmacêuticos/uso terapêutico , Radioisótopos de Ítrio/uso terapêutico
20.
J Vasc Interv Radiol ; 25(8): 1181-5, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24928649

RESUMO

PURPOSE: To compare the safety of permanent and retrievable inferior vena cava (IVC) filters by reviewing the U.S. Food and Drug Administration Manufacturer and User Facility Device Experience (MAUDE) database. MATERIALS AND METHODS: The MAUDE database was reviewed from January 1, 2009, to December 31, 2012. Product class search criteria were "filter, intravascular, cardiovascular." Type of device used and specific adverse events (AEs) were recorded. RESULTS: For the period January 2009-December 2012, 1,606 reported AEs involving 1,057 IVC filters were identified in the MAUDE database . Of reported AEs, 1,394 (86.8%) involved retrievable inferior vena cava filters (rIVCFs), and 212 (13.2%) involved permanent inferior vena cava filters (pIVCFs) (P < .0001). Reported AEs included fracture, migration, limb embolization, tilt, IVC penetration, venous thromboembolism and pulmonary embolism, IVC thrombus, and malfunctions during placement. Each specific AE was reported with significantly higher frequency in rIVCFs compared with pIVCFs. The most common reported complication with rIVCFs was fracture, whereas the most commonly reported complications with pIVCFs were placement malfunctions. For rIVCFs, the most commonly reported AE varied depending on filter brand. CONCLUSIONS: The MAUDE database reveals that complications occur with significantly higher frequency with rIVCFs compared with pIVCFs. This finding suggests that the self-reported complication rate with rIVCFs is significantly higher than the self-reported complication rate with pIVCFs.


Assuntos
Remoção de Dispositivo/efeitos adversos , Complicações Pós-Operatórias/etiologia , Implantação de Prótese/efeitos adversos , Implantação de Prótese/instrumentação , Filtros de Veia Cava/efeitos adversos , Bases de Dados Factuais , Migração de Corpo Estranho/etiologia , Humanos , Desenho de Prótese , Falha de Prótese , Fatores de Risco , Tromboembolia/etiologia , Fatores de Tempo , Resultado do Tratamento , Lesões do Sistema Vascular/etiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA