Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 341
Filtrar
1.
Clin Anat ; 2024 May 08.
Artigo em Inglês | MEDLINE | ID: mdl-38715464

RESUMO

The dysplastic hip is characterized by incomplete coverage of the femoral head, resulting in increased risk of early osteoarthritis. The morphological variation of the hip joint is diverse and clear differences exist between females and males. The aim of this observational study was therefore to investigate the relationship between the morphology of the hip, sex, and hip dysplasia using a three-dimensional model. Statistical shape models of the combined femur and pelvic bones were created from bilateral hips of 75 patients. Using manual angle measurements and regression analysis, the characteristic shape differences associated with sex and hip dysplasia were determined. The model showed clear differences associated with sex and hip dysplasia. We found that the acetabular anteversion in females was significantly higher (p < 0.0001) than in males while no significant difference in acetabular anteversion was found between normal and dysplastic hips (p = 0.11). The model showed that decreased acetabular anteversion resulted in the appearance of the cross-over sign and the prominent ischial spine sign commonly associated with retroversion. Sex could be predicted with an area under the curve of 0.99 and hip dysplasia could be predicted with an area under the curve of ≥0.73. Our findings suggest that retroversion is a result of decreased anteversion of the acetabulum and is primarily associated with sex. This finding should be taken into account during the reorientation of the acetabulum in the surgical treatment of hip dysplasia.

2.
Acta Orthop ; 95: 121-129, 2024 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-38391197

RESUMO

BACKGROUND AND PURPOSE: Cementless arthroplasty fixation relies on early bone ingrowth and may be poor in patients with low proximal tibial bone density or abnormal bone turnover. We aimed first to describe the baseline bone properties in patients undergoing medial unicompartmental knee replacement (UKR), and second to investigate its association with cemented and cementless tibial component migration until 2 years. METHODS: A subset investigation of 2 patient groups from a 3-armed randomized controlled trial was conducted. There were 26 cemented and 25 cementless medial UKRs with twin-pegged femoral components. Volumetric bone mineral density (vBMD) and microstructure of the excised medial tibial plateau were ascertained with µCT. Bone turnover was estimated using dynamic histomorphometry (eroded surface/bone surface = ES/BS, osteoid surface/bone surface = OS/BS, mineralizing surface/bone surface = MS/BS). Tibial component migration in 4 feature points was followed for 2 years with radiostereometry. RESULTS: At the 2-year follow-up, the cementless tibial components migrated 0.38 mm (95% confidence interval [CI] 0.14-0.62) total translation more than the cemented components at the posterior feature point. The greatest migration in the cementless group was subsidence at the posterior feature point of 0.66 mm (CI 0.48-0.84) until 6 weeks, and from 3 months the components were stable. Cemented tibial components subsided very little. Between 1- and 2-year follow-ups, no cementless but 4 cemented tibial components revealed continuous migration. OS/BS was half of the ES/BS. No µCT or histomorphometric parameters showed any clinically relevant correlation with tibial component migration at the posterior feature point for either cemented or cementless UKR at 6 weeks' or 2 years' follow-up after adjustment for age, BMI, and sex. CONCLUSION: Preoperative vBMD, bone turnover, and microstructure were not associated with postoperative tibial component migration of cemented and cementless medial UKR.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho , Humanos , Artroplastia do Joelho/efeitos adversos , Densidade Óssea , Prótese do Joelho/efeitos adversos , Falha de Prótese , Articulação do Joelho/cirurgia , Cimentos Ósseos , Desenho de Prótese , Resultado do Tratamento , Osteoartrite do Joelho/cirurgia
3.
Mol Genet Genomics ; 298(2): 329-342, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36454308

RESUMO

Developmental dysplasia of the hip (DDH) is a common condition involving instability of the hip with multifactorial etiology. Early diagnosis and treatment are critical as undetected DDH is an important cause of long-term hip complications. Better diagnostics may be achieved through genetic methods, especially for patients with positive family history. Several candidate genes have been reported but the exact molecular etiology of the disease is yet unknown. In the present study, we performed whole exome sequencing of DDH patients from 28 families with at least two affected first-degree relatives. Four genes previously not associated with DDH (METTL21B, DIS3L2, PPP6R2, and TM4SF19) were identified with the same variants shared among affected family members, in more than two families. Among known association genes, we found damaging variants in DACH1, MYH10, NOTCH2, TBX4, EVC2, OTOG, and SHC3. Mutational burden analysis across the families identified 322 candidate genes, and enriched pathways include the extracellular matrix, cytoskeleton, ion-binding, and detection of mechanical stimulus. Taken altogether, our data suggest a polygenic mode of inheritance for DDH, and we propose that an impaired transduction of the mechanical stimulus is involved in the etiopathological mechanism. Our findings refine our current understanding of candidate causal genes in DDH, and provide a foundation for downstream functional studies.


Assuntos
Displasia do Desenvolvimento do Quadril , Luxação Congênita de Quadril , Humanos , Sequenciamento do Exoma , Luxação Congênita de Quadril/genética , Luxação Congênita de Quadril/diagnóstico , Luxação Congênita de Quadril/patologia , Linhagem , Dinamarca
4.
Arch Orthop Trauma Surg ; 143(9): 5957-5965, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36802237

RESUMO

INTRODUCTION: Dual mobility implants have been successful in reducing postoperative hip dislocation but mid-term results of cup migration and polyethylene wear are missing in the literature. Therefore, we measured migration and wear at 5-year follow-up using radiostereometric analysis (RSA). MATERIALS AND METHODS: A cohort of 44 patients (mean age 73, 36 female) with heterogeneous indications for hip arthroplasty but all with a high risk of hip dislocation received total hip replacement (THA) with The Anatomic Dual Mobility X3 monoblock acetabular construct and a highly crosslinked polyethylene liner. RSA images and Oxford Hip Scores were obtained perioperatively and 1, 2, and 5 years postoperatively. Cup migration and polyethylene wear were calculated using RSA. RESULTS: Mean 2-year proximal cup translation was 0.26 mm (95% CI 0.17; 0.36). Proximal cup translation was stable from 1- to 5-year follow-up. Mean 2-year cup inclination (z-rotation) was 0.23° (95% CI - 0.22; 0.68) and was greater in patients with osteoporosis compared to patients without osteoporosis (p = 0.04). Using 1-year follow-up as baseline, the 3D polyethylene wear rate was 0.07 mm/year (0.05; 0.10). Oxford hip scores improved 19 (95% CI 14; 24) points from mean 21 (range 4; 39) at baseline, to 40 (9; 48) 2 years postoperatively. There were no progressive radiolucent lines > 1 mm. There was 1 revision for offset correction. CONCLUSIONS: Anatomic Dual Mobility monoblock cups were well-fixed, the polyethylene wear rate was low, and the clinical outcomes were good until 5-year follow-up suggesting good implant survival in patients of different age groups and with heterogeneous indications for THA.


Assuntos
Artroplastia de Quadril , Luxação do Quadril , Prótese de Quadril , Humanos , Feminino , Polietileno , Luxação do Quadril/cirurgia , Falha de Prótese , Desenho de Prótese , Acetábulo/cirurgia , Artroplastia de Quadril/métodos , Seguimentos
5.
Arch Orthop Trauma Surg ; 143(2): 1071-1080, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35113240

RESUMO

INTRODUCTION: The Exeter short stem (ESS) is 25 mm shorter than the standard length v40 Exeter stem (Stryker) and intended for a narrow femoral diaphysis. The purpose of the study was to evaluate the migration pattern of the cemented ESS. MATERIAL AND METHOD: In a prospective single-center cohort study, 23 patients (21 female) mean age 78 (range 70-89) with hip osteoarthritis and Dorr Type A femurs were included. Preoperative DXA was used to group patients into normal (> - 1) and low (< - 1) T-score. Components were the collarless polished double-tapered Exeter short stem type N°1 L125. Patients were followed for 2 years with model-based RSA (stem migration), regular hip radiographs (stem position and cementation quality), Oxford Hip Score (OHS) and VAS pain. RESULTS: At 2-year follow-up, the stems subsided 1.48 mm (CI 95% 1.69; 1.26) and retroverted 0.45° (CI 95% 0.01; 0.88). From 12 to 24 months, stem subsidence was 0.18 mm (CI 95% 0.1; 0.25) (p = 0.001) and retroversion was - 0.04° (CI 95% - 0.27; 0.18) (p = 0.70). T-score and stem subsidence correlated (rho = 0.48; p = 0.025) and patients with normal T-score (n = 7) had 0.42 mm (CI 95% - 0.01; 0.85) less subsidence as compared to patients with low T-score (n = 15) (p = 0.054). Stems in varus position (n = 9) subsided 1.7 mm (CI 95% 1.35; 2.05) compared to 1.33 mm (CI 95% 1.05; 1.60) for stems in neutral position (n = 13) (p = 0.07). Postoperative cementation quality did not influence 2-year stem migration. OHS improved to 40.7 (CI 95% 36.8; 44.7) and VAS pain at rest and activity decreased to 5 mm and 10 mm, respectively (p < 0.001). CONCLUSION: The 2-year migration pattern of the cemented ESS was similar to reports for the cemented standard length Exeter stem. Low preoperative T-score and varus stem-position showed a tendency for higher stem migration and should be studied as risk factors for failure in larger studies of cemented polished stems.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Feminino , Idoso , Análise Radioestereométrica , Prótese de Quadril/efeitos adversos , Seguimentos , Estudos Prospectivos , Estudos de Coortes , Desenho de Prótese , Dor/etiologia , Falha de Prótese
6.
Arch Orthop Trauma Surg ; 143(9): 5967-5976, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36802238

RESUMO

BACKGROUND: Pseudotumors and muscle atrophy have been associated with metal-on-metal (MoM) resurfacing hip arthroplasty (RHA). We aimed to investigate the influence of the anterolateral (AntLat) and the posterior (Post) surgical approach on the location, grade and prevalence of pseudotumors and muscle atrophy in MoM RHA. PATIENTS AND METHODS: Forty-nine patients were randomized to MoM RHA by the AntLat (n = 25) or the Post (n = 24) approach at Aarhus University Hospital. Patients underwent metal artifact reduction sequence (MARS) magnetic resonance imaging (MRI) scans for investigation of location, grade and prevalence of pseudotumors and muscle atrophy. Plain radiographs, metal-ions concentrations and clinical outcome scores were evaluated to compare outcomes of the surgical approaches. RESULTS: MRI-detected pseudotumors were seen in 7 of 18 patients (39%) in the AntLat group and in 12 of 22 patients (55%) in the Post group (p = 0.33). Pseudotumors were mainly located anterolaterally to the hip joint in the AntLat group and postero-lateral to the hip joint in the Post group. Higher grades of muscle atrophy of the caudal part of the gluteus medius and minimus (p < 0.004) were seen in the AntLat group, and higher grades of muscle atrophy of the small external rotators were seen in the Post group (p < 0.001). The AntLat group had higher anteversion angles of mean 15.3° (range 6.1-7.5) versus mean 11.5° (range 4.9-22.5) in the Post group (p = 0.02). Metal-ion concentrations and clinical outcome scores were similar between groups (p > 0.08). CONCLUSION: Muscle atrophy and pseudotumor location after MoM RHA follow the surgical approach used for implantation. This knowledge may help differentiate between "normal postoperative appearance" and "MoM disease."


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Próteses Articulares Metal-Metal , Humanos , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/métodos , Metais , Imageamento por Ressonância Magnética/métodos , Atrofia Muscular/diagnóstico por imagem , Atrofia Muscular/etiologia , Desenho de Prótese , Cobalto
7.
Arch Orthop Trauma Surg ; 143(12): 7169-7183, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37568057

RESUMO

BACKGROUND: The component design and fixation method of joint arthroplasty may affect component migration and survival. The aim of this study was to compare fixation of cementless twin-peg (CLTP), cemented twin-peg (CTP) and cemented single-peg (CSP) femoral components of medial unicompartmental knee replacement (UKR). METHODS: Eighty patients (mean age = 63 years, 48 males) with medial knee osteoarthritis were randomized in three ways to CLTP (n = 25), CTP (n = 26) or CSP (n = 29) femoral UKR components. The patients were followed 5 years postoperatively with RSA, bone mineral density (BMD), PROMs and radiological evaluation of radiolucent lines (RLL), femoral component flexion angle and complications. RESULTS: At the 5-year follow-up, femoral component total translation was comparable between the three groups (p = 0.60). Femoral component internal rotation was 0.50° (95% CI 0.3; 0.69) for the CLTP group, 0.58° (95% CI 0.38; 0.77) for the CTP group and 0.25° (95% CI 0.07; 0.43) for the CSP group (p = 0.01). BMD decreased peri-prosthetically (range - 11.5%; - 14.0%) until 6-month follow-up and increased toward the 5-year follow-up (range - 3.6%; - 5.8%). BMD change did not correlate with component migration. Lower flexion angle was correlated with higher 5-year subsidence, total translation, varus rotation and maximum total point motion (p = 0.01). Two patients (1 CLTP, 1 CTP) had RLL in the posterior zone. There were two revisions. CONCLUSION: At 5-year follow-up, fixation of UKA femoral components with twin-peg was not superior to the single-peg design. Cementless and cemented twin-peg femoral components had similar fixation. A lower flexion angle was correlated with higher component migration.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho , Masculino , Humanos , Pessoa de Meia-Idade , Artroplastia do Joelho/métodos , Desenho de Prótese , Osteoartrite do Joelho/cirurgia , Radiografia , Resultado do Tratamento , Articulação do Joelho/cirurgia , Falha de Prótese , Cimentos Ósseos
8.
Knee Surg Sports Traumatol Arthrosc ; 30(9): 3100-3113, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35099597

RESUMO

PURPOSE: Cementless tibial components migrate initially until osseointegration and preserve periprosthetic bone. Cemented tibial components are fixed from surgery but loose periprosthetic bone. Little is known about bone formation and resorption biomarkers in relation to component fixation and bone mineral density (BMD) changes of cementless and cemented total knee arthroplasty. We hypothesize a similar migration of cemented and cementless tibial components between 1- and 2-year follow-up indicating a stable long-term fixation. METHODS: In a prospective patient-blinded randomized study, we compared cementless (n = 27) and cemented (n = 26) tibial components with radiostereometry measured migration (MTPM = Maximum Total Point Motion: point of component that migrates the most) and changes in BMD and biochemical bone turnover markers (BTMs) until 24 months after surgery. RESULTS: The mean MTPM between 12 and 24 months were similar between groups with - 0.06 mm (95% CI - 0.23; 0.11) in the cementless group compared to 0.02 mm (95% CI - 0.07; 0.11) in the cemented group. However, there was a higher proportion of cementless components (16/25) than cemented components (7/24) with continuous migration (MTPM > 0.2 mm) (p = 0.02). In the medial and anterior region below the tibial components, the BMD increased by mean 1.8% and 7.4% for cementless components and decreased by mean 8.6% and 4.2% for cemented components until 24-month follow-up. In both groups, BTMs initially showed increased bone resorption (CTx) and bone formation (P1NP) followed by normalization to pre-operative levels at 6 months post-surgery. CONCLUSION: More cementless components than cemented components showed continues migration which suggest a higher risk of early revision. Bone turnover increased post-surgery in both groups, but did not explain the difference in change in periprosthetic BMD. LEVEL OF EVIDENCE: I.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho , Cimentos Ósseos , Densidade Óssea , Remodelação Óssea , Seguimentos , Humanos , Estudos Prospectivos , Desenho de Prótese , Falha de Prótese
9.
Acta Orthop ; 93: 375-381, 2022 03 21.
Artigo em Inglês | MEDLINE | ID: mdl-35347340

RESUMO

BACKGROUND AND PURPOSE: Dual-mobility hip arthroplasty utilizes a freely rotating polyethylene acetabular liner to protect against dislocation. As liner motion has not been confirmed in vivo, we undertook this using dynamic radiostereometry (RSA). PATIENTS AND METHODS: 6 patients with Anatomical Dual Mobility acetabular components were included. Markers were implanted in the liners using a drill guide. Static RSA recordings and patient-reported outcome measures were obtained postoperatively and at 1-year follow-up. Dynamic RSA recordings were obtained at 1-year follow-up during passive hip movement: abduction/external rotation, adduction/internal rotation (modified FABER-FADIR), to end-range and at 45° hip flexion. Liner and neck movements were described as anteversion, inclination, and rotation. RESULTS: Liner movement during modified FABER-FADIR was detected in 12 of 16 patients. Median (range) absolute liner movements were: anteversion 10° (5-20), inclination 6° (2-12), and rotation 11° (5-48) relative to the cup. Median absolute change in the resulting liner/neck angle (small articulation) was 28° (12-46) and in liner/cup angle (larger articulation) was 6° (4-21). Static RSA showed changes in median liner anteversion from 7° (-12 to 23) postoperatively to 10° (-3 to 16) at 1-year follow-up and inclination from 42° (35-66) postoperatively to 59° (46-80) at 1-year follow-up. Liner/neck contact was associated with high initial liner anteversion (p = 0.01). INTERPRETATION: The polyethylene liner moves over time. 1 year after surgery the liner can move with or without liner/neck contact. The majority of movement is in the smaller articulation between head and liner.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Artroplastia de Quadril/efeitos adversos , Humanos , Polietileno , Análise Radioestereométrica , Amplitude de Movimento Articular
10.
Acta Orthop ; 93: 658-664, 2022 07 14.
Artigo em Inglês | MEDLINE | ID: mdl-35848733

RESUMO

BACKGROUND AND PURPOSE: BoneMaster (BM) is a thin electrochemically applied hydroxyapatite (HA) implant coating marketed with expectations of improved osseointegration properties but less polyethylene (PE) wear. We compared the midterm cup migration and PE wear of cementless porous-coated hemispherical cups with and without BM. PATIENTS AND METHODS: In this patient-blinded, randomized controlled trial, 53 patients with a mean age of 64 years (55-75) received total hip arthroplasty with a porous-coated (P) or porous and BoneMaster (PBM) coated Exceed cup and ArCom E1 infused PE. Patients were followed with RSA, Hip Osteoarthritis Outcome Score (HOOS), and Euro-Qol-5-3L (EQ-5D) at 3 and 6 months, and 1-, 2-, and 5-year follow-up. RESULTS: At 5-year follow-up, total translation and maximum total point motion was 0.28 mm (95% CI 0.08; 0.47) and 0.52 mm (CI 0.12; 0.93) higher in the PBM group than in the P group. PE wear was comparable between PBM and P cups, and 2D wear rate from 1-year follow-up to last follow-up was 0.03 mm (CI 0.02-0.03). The 5-year anterior translation was 0.05 mm (CI -0.10 to 0.21) in the normal BMD group and 0.40 mm (CI 0.22-0.57) in the osteopenia group. INTERPRETATION: At 5-year follow-up, Exceed cups in the PBM group migrated more than in the P group but the PE wear rate was low and similar. This study does not indicate any advantage of additional BoneMaster coating compared with porous coating alone on cementless hemispherical cups with regards to migration, polyethylene wear, and clinical outcomes.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Artroplastia de Quadril/efeitos adversos , Durapatita , Seguimentos , Humanos , Pessoa de Meia-Idade , Polietileno , Porosidade , Desenho de Prótese , Falha de Prótese , Titânio
11.
J Shoulder Elbow Surg ; 30(6): 1299-1308, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33548396

RESUMO

BACKGROUND: Several studies have confirmed a high rate of unexpected positive cultures (UPCs) after presumably aseptic revisions of shoulder arthroplasties; however, the impact on the outcome is still unclear. The purpose of this prospective study is to compare the patient-reported outcomes of standard revisions with and without the emergence of UPCs. METHODS: During a 3-year period, we included all patients who were revised for reasons other than suspicion of infection from 2 orthopedic centers. Five biopsies were obtained from every revision, and only cultures with the same bacteria in at least 3 biopsy specimens were classified as UPCs. All patients were assessed using the Oxford Shoulder Score (OSS) and range of motion preoperatively and after at least a 2-year follow-up. RESULTS: In this study, 124 patients were included, with a median follow-up of 29 months (range 29-32), and UPCs emerged after 27 revisions (22%), with Cutibacterium acnes accounting for 67% (18/27). At baseline, the OSS was 22 in both the culture-negative and UPC groups (P = .46). Then, at follow-up, the OSS was 37 in the culture-negative group and 35 in the UPC group (P = .91). The forward elevation increased significantly by 44° and 41°, respectively, in the 2 groups, but no statistically significant difference between the culture-negative group and the UPC group was found (P = .66). In contrast, the external rotation was unchanged after the revision, and again, no difference in the change between the culture-negative and UPC groups (P = .54) was observed. Subgroup analyses stratified by different implant designs revealed equal patterns with no statistical differences in outcome. CONCLUSION: We did not find a difference in outcome after a presumed aseptic revision regardless of the emergence of UPCs. Similarly, we could not demonstrate that patients with UPCs presented with poorer function at baseline compared with culture-negative patients. The clinical relevance of UPCs thus requires further evaluation, especially in the case of C acnes as a potential pathogenic versus a merely colonizing microbe.


Assuntos
Artroplastia do Ombro , Infecções Relacionadas à Prótese , Articulação do Ombro , Artroplastia do Ombro/efeitos adversos , Humanos , Propionibacterium acnes , Estudos Prospectivos , Infecções Relacionadas à Prótese/diagnóstico , Infecções Relacionadas à Prótese/etiologia , Infecções Relacionadas à Prótese/cirurgia , Reoperação , Estudos Retrospectivos , Articulação do Ombro/cirurgia
12.
Acta Orthop ; 92(3): 285-291, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33538223

RESUMO

Background and purpose - In patients with hip dysplasia, knowledge of hip muscle strength after periacetabular osteotomy is lacking. We investigated isometric hip muscle strength in patients with hip dysplasia, before and 1 year after periacetabular osteotomy, and compared this with healthy volunteers. Furthermore, we investigated whether pre- to post-surgical changes in self-reported pain and sporting function were associated with changes in isometric hip muscle strength.Patients and methods - Isometric hip muscle strength was assessed twice in 82 patients (11 men) with a mean age of 30 (SD 9) years, before and 1 year after surgery, and once in 50 healthy volunteers. Isometric hip muscle strength was assessed with a hand-held dynamometer. Copenhagen Hip and Groin Outcome Score was used to measure self-reported outcome.Results - Despite 1-year improvements in isometric hip flexion (0.1 Nm/kg; 95% CI 0.06-0.2) and abduction (0.1 Nm/kg; CI 0.02-0.2), the patients' muscle strength was 13-34% lower than the strength of the healthy volunteers both pre- and post-surgery (p < 0.01). Moreover, changes in self-reported pain were associated with changes in hip flexion (13 points per Nm/kg; CI 1-26) and abduction (14 points per Nm/kg; CI 3-25), while changes in self-reported sporting function were associated with changes in hip extension (9 points per Nm/kg; CI 1-18).Interpretation - Isometric hip muscle strength is impaired in symptomatic dysplastic hips measured before periacetabular osteotomy. 1 year after surgery, isometric hip flexion and abduction strength had improved but muscle strength did not reach that of healthy volunteers.


Assuntos
Acetábulo/cirurgia , Luxação do Quadril/fisiopatologia , Luxação do Quadril/cirurgia , Contração Isométrica/fisiologia , Força Muscular/fisiologia , Osteotomia , Adulto , Estudos de Casos e Controles , Estudos de Coortes , Feminino , Humanos , Masculino , Músculo Esquelético/fisiopatologia , Autorrelato , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
13.
Acta Orthop ; 92(6): 746-752, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34334093

RESUMO

Background and purpose - Tourniquet is widely used in orthopedic surgery to reduce intraoperative bleeding and improve visualization. We evaluated the effect of tourniquet application on peri- and postoperative cefuroxime concentrations in subcutaneous tissue, skeletal muscle, calcaneal cancellous bone, and plasma. The primary endpoint was the time for which the free cefuroxime concentration was maintained above the clinical breakpoint minimal inhibitory concentration (T > MIC) for Staphylococcus aureus (4 µg/mL).Patients and methods - 10 patients scheduled for hallux valgus or hallux rigidus surgery were included. Microdialysis catheters were placed for sampling of cefuroxime concentrations bilaterally in subcutaneous tissue, skeletal muscle, and calcaneal cancellous bone. A tourniquet was applied on the thigh of the leg scheduled for surgery (tourniquet duration time [range]: 65 minutes [58-77]). Cefuroxime (1.5 g) was administered intravenously 15 minutes prior to tourniquet inflation, followed by a second dose 6 hours later. Dialysates and venous blood samples were collected for 12 hours.Results - A cefuroxime concentration of 4 µg/mL was reached within 23 minutes in all compartments and patients. For cefuroxime the T > MIC (4 µg/mL) ranged between 4.8 and 5.4 hours across compartments, with similar results for the tourniquet and non-tourniquet leg. Comparable T > MIC and penetration ratios were found for the first and second dosing intervals.Interpretation - Administration of cefuroxime (1.5 g) 15 minutes prior to tourniquet inflation is safe in order to achieve tissue concentrations above 4 µg/mL throughout surgery. A tourniquet application time of approximately 1 hour did not affect the cefuroxime tissue penetration in the following dosing interval.


Assuntos
Cefuroxima/farmacocinética , Hallux Rigidus/cirurgia , Hallux Valgus/cirurgia , Procedimentos Ortopédicos/métodos , Torniquetes , Idoso , Antibacterianos/farmacocinética , Osso Esponjoso/metabolismo , Estudos de Coortes , Feminino , Humanos , Masculino , Testes de Sensibilidade Microbiana , Pessoa de Meia-Idade , Músculo Esquelético/metabolismo , Gordura Subcutânea/metabolismo , Fatores de Tempo
14.
J Antimicrob Chemother ; 75(8): 2206-2212, 2020 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-32413120

RESUMO

BACKGROUND: Pyogenic spondylodiscitis remains a therapeutic challenge, as demonstrated by divergent treatment guidelines. The combination of moxifloxacin and rifampicin may be an attractive treatment option for cases caused by staphylococci; however, previous studies have reported a reduction in plasma concentrations of moxifloxacin when coadministered with rifampicin. The magnitude of this reduction in spinal tissues is not known. OBJECTIVES: To investigate the effect of rifampicin on moxifloxacin tissue concentrations in vertebral cancellous bone, the intervertebral disc and subcutaneous adipose tissue under steady-state conditions using microdialysis in a porcine model. METHODS: Twenty female pigs were randomized into two groups of 10 pigs. Group A received 400 mg of moxifloxacin orally once daily for 3 days preoperatively. Group B received 400 mg of moxifloxacin orally once daily for 3 days preoperatively combined with 450 mg of rifampicin twice daily for 7 days preoperatively. Measurements were obtained from plasma, vertebral cancellous bone, the intervertebral disc and subcutaneous adipose tissue for 24 h. Microdialysis was applied for sampling in solid tissues. RESULTS: Coadministration of moxifloxacin and rifampicin demonstrated a reduction of free moxifloxacin concentrations in spinal tissues. Cmax and AUC0-24 in all tissue compartments decreased in the ranges of 66%-79% and 65%-76%, respectively. CONCLUSIONS: Using microdialysis, we demonstrated a significant reduction of moxifloxacin Cmax and AUC0-24 in the spinal tissues when coadministered with rifampicin.


Assuntos
Vértebras Cervicais , Rifampina , Animais , Feminino , Fluoroquinolonas , Microdiálise , Moxifloxacina , Plasma , Suínos
15.
Acta Anaesthesiol Scand ; 64(3): 368-377, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31650529

RESUMO

BACKGROUND: A femoral nerve block relieves pain after total hip arthroplasty, but its use is controversial due to motor paralysis accompanied by an increased risk of fall. Assumedly, the iliopsoas plane block (IPB) targets the hip articular branches of the femoral nerve without motor blockade. However, this has only been indicated in a cadaver study. Therefore, we designed this volunteer study. METHODS: Twenty healthy volunteers were randomly allocated to blinded paired active vs. sham IPB (5 mL lidocaine 18 mg/mL with epinephrine vs saline). The primary outcome was reduction of maximal force of knee extension after IPB compared to baseline. Secondary outcomes included reduction of maximal force of hip adduction, and the pattern of injectate spread assessed with magnetic resonance imaging. RESULTS: Mean (confidence interval) change of maximal force of knee extension from baseline to after IPB was -9.7 N (-22, 3.0) (P = .12) (n = 14). The injectate was consistently observed in an anatomically well-defined closed fascial compartment between the intra- and extra-pelvic components of the iliopsoas muscle anterior to the hip joint. CONCLUSION: We observed no significant reduction of maximal force of knee extension after an IPB. The injectate was contained in a fascial compartment previously shown to contain all sensory branches from the femoral nerve to the hip joint. The clinical consequence of selective anesthesia of all sensory femoral nerve branches from the hip could be a reduced risk of fall compared to a traditional femoral nerve block. Registration of Trial: The trial was prospectively registered in EudraCT (Reference: 2018-000089-12, https://www.clinicaltrialsregister.eu/ctr-search/search?query=2018-000089-12).


Assuntos
Anestésicos Locais/administração & dosagem , Nervo Femoral/efeitos dos fármacos , Lidocaína/administração & dosagem , Bloqueio Nervoso/métodos , Paresia/prevenção & controle , Adulto , Método Duplo-Cego , Epinefrina/administração & dosagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Músculos Psoas , Valores de Referência , Solução Salina/administração & dosagem , Adulto Jovem
16.
Clin Rehabil ; 34(1): 82-90, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31663369

RESUMO

OBJECTIVE: The aim of this study was to investigate the effect of adding four weeks preoperative progressive resistance training (PRT) to four weeks postoperative PRT on patient function, muscle strength, and other outcomes 12 months after total knee arthroplasty (TKA). DESIGN: Twelve-month follow-up data from a previously published randomized controlled trial. SETTING: Aarhus University Hospital, Silkeborg Regional Hospital, and Aarhus University. SUBJECTS: A total of 59 patients scheduled for TKA were enrolled in a single-blinded, clinical randomized controlled trial. INTERVENTIONS: Participants were randomized to preoperative PRT (intervention group) or to a control group who "lived as usual" the last four weeks before TKA. The intervention group completed four weeks preoperative and four weeks postoperative PRT, whereas the control group only completed four weeks postoperative PRT. Main follow-up measures were as follows: the 30-second Chair Stand Test (primary outcome), Timed Up and Go Test, walk tests, knee extensor, and knee flexor muscle strength and patient-reported outcomes. Statistical analyses were performed according to the intention-to-treat principle. RESULTS: No significant group differences were observed for the primary outcome 30-second Chair Stand Test (4.0 repetitions versus 2.4 repetitions, P = 0.067) or for other functional performance outcomes. The intervention group had significantly higher weight-normalized knee extensor muscle strength (0.5 Nm/kg versus 0.2 Nm/kg, P = 0.002) and knee flexor muscle strength (0.3 Nm/kg versus 0.2 Nm/kg, P = 0.042) in the operated leg when compared to the control group. No significant group differences for patient-reported outcomes. CONCLUSION: The study supports the use of short-term high-intensity resistance training before TKA as it induces a long-lasting effect on muscle strength, while it may have no discernible effect on functional performance.


Assuntos
Artroplastia do Joelho , Osteoartrite do Joelho/cirurgia , Treinamento Resistido , Idoso , Feminino , Seguimentos , Humanos , Articulação do Joelho/fisiopatologia , Masculino , Pessoa de Meia-Idade , Força Muscular/fisiologia , Osteoartrite do Joelho/fisiopatologia , Medidas de Resultados Relatados pelo Paciente , Equilíbrio Postural , Método Simples-Cego , Estudos de Tempo e Movimento
17.
Knee Surg Sports Traumatol Arthrosc ; 28(5): 1639-1647, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-31062043

RESUMO

PURPOSE: Patients with femoroacetabular impingement syndrome (FAIS) are young and middle-aged persons living physically active lives including sports activities. However, measurements of the physical activity level before and after hip arthroscopic surgery in patients with FAIS using both self-reported and objective accelerometer-based measures are lacking. Furthermore, comparing patients with a reference group of persons reporting no hip problems and conducting subgroup analyses investigating changes in physical activity level and self-reported outcomes according to pre-surgery activity level may further highlight the activity pattern for patients. METHODS: Sixty patients with FAIS eligible for hip arthroscopic surgery were consecutively included in a prospective cohort study (HAFAI cohort) together with 30 reference persons reporting no hip problems. Participants completed the Copenhagen Hip and Groin Outcome Score (HAGOS) together with questions regarding their sports activities. Furthermore, participants wore a three-axial accelerometer for five consecutive days during waking hours. The accelerometer-based data were analysed and presented as total activity and type, frequency and duration of activities. RESULTS: Patients experienced significant and clinically relevant changes in all HAGOS scores. 88% of patients participated in some kind of sports activity 1 year after surgery. Overall, objectively measured physical activity did not change from before to 1 year after surgery. However, subgroup analyses of the most sedentary patients preoperatively revealed significant changes towards a more active pattern. Compared to reference persons, patients performed less bicycling and running. CONCLUSION: Despite clinically relevant changes in self-reported outcomes, patients did not increase their overall physical activity level 1 year after surgery. Physical activity levels were lower in patients than in the reference group and patients continued bicycling and running less compared with the reference group. LEVEL OF EVIDENCE: II.


Assuntos
Artroscopia , Exercício Físico , Impacto Femoroacetabular/cirurgia , Medidas de Resultados Relatados pelo Paciente , Esportes , Acelerometria , Adulto , Artroscopia/métodos , Feminino , Articulação do Quadril/cirurgia , Humanos , Masculino , Estudos Prospectivos , Comportamento Sedentário , Autorrelato , Resultado do Tratamento
18.
Acta Orthop ; 91(3): 299-305, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32106751

RESUMO

Background and purpose - Few studies have evaluated the long- and mid-term outcomes after minimally invasive periacetabular osteotomy (PAO). We investigated: (1) the long-term hip survival rate after PAO; (2) the risk of complications and additional surgery after PAO; and (3) the hip function at different follow-up points.Patients and methods - We reviewed 1,385 hips (1,126 patients) who underwent PAO between January 2004 and December 2017. Through inquiry to the Danish National Patient Registry we identified conversions to total hip arthroplasty (THA) and complications after PAO. We evaluated the Hip disability and Osteoarthritis Outcome Score (HOOS) obtained preoperatively, and at 6 months, 2-, 5-, and 10-years' follow-up.Results - 73 of the 1,385 hips were converted to THA. The overall Kaplan-Meier hip survival rate was 80% (95% CI 68-88) at 14 years with a mean follow-up of 5 years (0.03-14). 1.1% of the hips had a complication requiring surgical intervention. The most common additional surgery was removal of screws (13%) and 11% received a hip arthroscopy. At the 2-year follow-up, HOOS pain improved by a mean of 26 points (CI 24-28) and a HOOS pain score > 50 was observed in 86%.Interpretation - PAO preserved 4 of 5 hips at 14 years, with higher age leading to lower survivorship. The PAO technique was shown to be safe; 1.1% of patients had a complication that demanded surgical intervention. The majority of the patients with preserved hips have no or low pain. The operation is effective with a good clinical outcome.


Assuntos
Acetábulo/cirurgia , Osteotomia/métodos , Adolescente , Adulto , Artroplastia de Quadril/estatística & dados numéricos , Dinamarca/epidemiologia , Feminino , Seguimentos , Articulação do Quadril/cirurgia , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Osteotomia/efeitos adversos , Osteotomia/estatística & dados numéricos , Sistema de Registros , Resultado do Tratamento , Adulto Jovem
19.
Acta Orthop ; 91(1): 26-32, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31698977

RESUMO

Background and purpose - BoneMaster (BM) is an electrochemically deposited hydroxyapatite (HA) implant-coating, which is evenly distributed, thin, and quickly resorbed. It is designed to stimulate osseointegration and early implant stability and alleviate longer-term HA-induced third-body polyethylene wear. This study evaluates early cup migration and functional outcomes of cementless porous-coated hemispherical cups with or without BM.Patients and methods - In a patient-blinded, randomized, controlled trial 53 patients at mean 64 years (55-75) with coxarthritis were operated with an Exceed cup (Zimmer Biomet) and Bi-Metric stem (Zimmer Biomet) with porous and BM coating (PBM) or with porous coating alone (P). Follow-ups were performed postoperatively and at 3, 6, 12, and 24 months. Effect measures were cup migration measured with RSA and PROMs.Results - At 6-month follow-up, proximal cup migration in the PBM group (0.09 mm, 95% CI 0.02-0.20) was higher than in the P group (0.25 mm, CI 0.15-0.35). At 1- and 2-year follow-up, cup migration in all 6 degrees of freedom was similar between groups (p > 0.2). From before surgery to 2-year follow-up, Oxford Hip Score (OHS) increased by 17 points (CI 14-20). Hip disability and Osteoarthritis Outcome Score (HOOS) increased in all sub-scores, but was more pronounced for PBM cups compared with P cups in the Symptoms sub-score (p = 0.04).Interpretation - Contrary to expectations, PBM cups had higher early migration than P cups. At 2-year follow-up, migration was similar between groups. There seems to be no early benefit of BM coating on acetabular cups.


Assuntos
Artroplastia de Quadril , Materiais Revestidos Biocompatíveis , Prótese de Quadril , Osseointegração , Osteoartrite do Quadril/cirurgia , Falha de Prótese , Idoso , Materiais Biocompatíveis , Durapatita , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Análise Radioestereométrica , Método Simples-Cego
20.
Acta Anaesthesiol Scand ; 63(1): 101-110, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30109702

RESUMO

BACKGROUND: Cutaneous nerve blockade may improve analgesia after hip surgery. Anaesthesia after the lateral femoral cutaneous (LFC) nerve block is too distal for complete coverage of most hip surgery incisions, which requires additional anaesthesia of the adjacent, proximal area. The transversalis fascia plane (TFP) block potentially anaesthetises the iliohypogastric and subcostal nerves. The primary aim of the present study was to investigate, if the TFP block provides cutaneous anaesthesia adjacent to the LFC nerve block. METHODS: Active vs placebo TFP blocks were compared in a paired randomised controlled trial (RCT) in 20 volunteers, who all had bilateral LFC nerve blocks. The day preceding the RCT, the area anaesthetised by a novel selective ultrasound guided subcostal nerve block was identified bilaterally in order to assess the contribution of the subcostal nerve to the area anaesthesia by the TFP block. RESULTS: Anaesthesia of the lateral hip region after TFP block was 80%. The cutaneous anaesthesia after active TFP block was in continuity with the LFC nerve block in 65%. Combined TFP and LFC nerve blockade significantly increased the coverage of hip surgery incisions compared to LFC nerve block alone. The success rate of blocking the subcostal nerve was 50% with the TFP block. CONCLUSION: The TFP block anaesthetises the skin proximal to the LFC nerve block by anaesthetising the iliohypogastric and subcostal nerves. TFP block as a supplement to LFC nerve block improves the coverage of the proximal surgical incisions used for hip surgery.


Assuntos
Quadril/cirurgia , Bloqueio Nervoso/métodos , Pele/inervação , Adulto , Feminino , Nervo Femoral , Humanos , Masculino
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA