Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
PLoS One ; 19(7): e0307558, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39052663

RESUMO

BACKGROUND: Accurate tumor volume estimation is important for evaluating the response to radionuclide therapy and external beam radiotherapy as well as to other pharmaceuticals. A common method for monitoring the growth of subcutaneous tumors in pre-clinical models and assessing the treatment response is to measure the tumor length and width by external calipers to estimate its volume. This procedure relies on an assumption of a spheroidal tumor shape wherein the tumor depth equals the width and can yield considerably inaccuracies. Ultrasound imaging is a non-invasive technique that can measure all three axes of the tumor and might be an alternative to caliper measurement with potentially greater accuracy and comparable ease-of-use and throughput. Both 2D and 3D ultrasound imaging are possible, the former offering short scan times without the need for anesthesia and heating-valuable factors for longitudinal studies in large animal cohorts. Nevertheless, tumor volume estimation accuracy by 2D ultrasound imaging has seen limited investigation. In this study we have evaluated the accuracy of tumor volume estimation by caliper and 2D ultrasound with comparisons to reference measurements by magnetic resonance imaging (MRI) in a pre-clinical model of prostate cancer treated with either external beam radiotherapy, radionuclide therapy, or no treatment. RESULTS: Tumor volumes were measured longitudinally in 29 mice by caliper, ultrasound, and MRI before and after external beam radiotherapy, [177Lu]Lu-PSMA-617 radionuclide therapy, or no treatment. Caliper measurements had a marked bias, overestimating the tumor volumes by a median of 150% compared to MRI. Ultrasound measurements were markedly more accurate, with a median bias of -21% compared to MRI. CONCLUSION: Ultrasound imaging is a reliable and accurate method for tumor volume estimation in pre-clinical models of radiotherapy, whereas caliper measurements are prone to overestimation.


Assuntos
Imageamento por Ressonância Magnética , Neoplasias da Próstata , Carga Tumoral , Ultrassonografia , Animais , Ultrassonografia/métodos , Imageamento por Ressonância Magnética/métodos , Camundongos , Masculino , Neoplasias da Próstata/radioterapia , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Humanos , Linhagem Celular Tumoral , Ensaios Antitumorais Modelo de Xenoenxerto
2.
Am J Nucl Med Mol Imaging ; 13(4): 147-155, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37736493

RESUMO

We have previously investigated the biodistribution and therapy effect of a humanized monoclonal antibody targeting free prostate-specific antigen (fPSA) intended for theranostics of hormone-refractory prostate cancer. In the present study, we evaluated the off-target effect and different linear energy transfer (LET) radionuclides without the effect of PSA targeting by using an antibody with the same scaffold as previously used immunoconjugates but with random, non-specific, antigen binding region. This allows us to identify alterations generated by specific targeting and those related to passive bystander effects, such as enhanced permeability and retention (EPR). A control humanized IgG monoclonal antibody (hIgG1) and an isotype control IgG monoclonal antibody were conjugated with the chelator CHX-A"-DTPA. The immunoconjugate was radiolabeled with either Lutetium-177 ([177Lu]Lu) or Indium-111 ([111In]In). A biodistribution study in mice carrying LNCaP xenografts, was performed to evaluate the non-specific uptake of [177Lu]Lu-hIgG1 in tumors and normal organs. Further, therapy studies of [177Lu]Lu and [111In]In labeled IgG were performed in BALB/c mice carrying LNCaP xenografts. Tumor tissues of treated xenografts and control were sectioned and immunohistochemically stained for Ki67 and PSA. The highest tumor uptake for the [177Lu]Lu-hIgG1 was seen at 72 hours (7.2±2 %IA/g), when comparing the tumor uptake of the fPSA targeting antibody to the non-specific antibody, the non-specific antibody contributes to half of the tumor uptake at 72 h. The liver uptake was 3.1±0.5 %IA/g at 24 h, 2.8±0.5 %IA/g at 72 h and 1.3±0.6 %IA/g at 120 h in LNCaP xenografts, which was approximately three times lower at 24 h and two times lower at 72 h than for the antibody with preserved targeting. Immunohistochemical labeling showed a reduction of PSA expression and a reduction of Ki67 labeled cells in the [111In]In treated LNCaP tumors, compared to vehicle and [177Lu]Lu treated mice. In conclusion, we found that specific targeting might negatively influence normal organ uptake when targeting secreted antigens. Furthermore, different energy deposition i.e. linear energy transfer of a radionuclide might have diverse effects on receptor expression and cell proliferation in tumors.

3.
Cancers (Basel) ; 13(14)2021 Jul 11.
Artigo em Inglês | MEDLINE | ID: mdl-34298682

RESUMO

BACKGROUND: The humanized monoclonal antibody (mAb) hu5A10 specifically targets and internalizes prostate cancer cells by binding to prostate specific antigen (PSA). Preclinical evaluations have shown that hu5A10 is an excellent vehicle for prostate cancer (PCa) radiotheranostics. We studied the impact of different chelates and conjugation ratios on hu5A10's target affinity, neonatal fc-receptor interaction on in vivo targeting efficacy, and possible enhanced therapeutic efficacy. METHODS: In our experiment, humanized 5A10 (hu5A10) was conjugated with DOTA or DTPA at a molar ratio of 3:1, 6:1, and 12:1. Surface plasmon resonance (SPR) was used to study antigen and FcRn binding to the antibody conjugates. [111In]hu5A10 radio-immunoconjugates were administered intravenously into BALB/c mice carrying subcutaneous LNCaP xenografts. Serial Single-photon emission computed tomography (SPECT) images were obtained during the first week. Tumors were harvested and radionuclide distribution was analyzed by autoradiography along with microanatomy and immunohistochemistry. RESULTS: As seen by SPR, the binding to PSA was clearly affected by the chelate-to-antibody ratio. Similarly, FcRn (neonatal fc-receptor) interacted less with antibodies conjugated at high ratios of chelator, which was more pronounced for DOTA conjugates. The autoradiography data indicated a higher distribution of radioactivity to the rim of the tumor for lower ratios and a more homogenous distribution at higher ratios. Mice injected with ratio 3:1 111In-DOTA-hu5A10 showed no significant difference in tumor volume when compared to mice given vehicle over a time period of 3 weeks. Mice given a similar injection of ratio 6:1 111In-DOTA-hu5A10 or 6:1 111In-DTPA-hu5A10 or 12:1 111In-DTPA-hu5A10 showed significant tumor growth retardation. Conclusions: The present study demonstrated that the radiolabeling strategy could positively modify the hu5A10's capacity to bind PSA and complex with the FcRn-receptor, which resulted in more homogenous activity distribution in tumors and enhanced therapy efficacy.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA