Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
J Card Surg ; 36(9): 3381-3383, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34091957

RESUMO

We present the case of a 73-year-old male patient undergoing a modified Bentall-DeBono procedure in 2015 due to aortic stenosis and aortic aneurism involving the root. A bioprosthetic stented conduit made with a stented Edwards Perimount 21-mm bioprosthesis and a Vascutek Valsalva 28-mm Dacron graft was implanted along with a mitral annuloplasty. Five years later, due to early degeneration of the bioprosthesis and a progression of the mitral disease, he underwent a second surgical procedure where a Medtronic Mosaic 27-mm valve prosthesis was implanted in mitral position and a sutureless Livanova Perceval 23-mm valve in aortic position. Because of the difficulty in removing the previously implanted aortic prosthesis, the Perceval valve was inserted inside the frame of the PeriMount as an open "valve-in-valve" procedure. In October 2020, the patient underwent a ViV TAVI with a 23-mm Edwards Sapien 3 (Edwards Lifescience). After induction of general anesthesia and heparin administration, the procedure was performed via right femoral artery approach with preimplantation of two Proglides. After transfemoral insertion of a 14-French sheath, the aortic valve was crossed with a 0.035-in. straight guide-wire, taking care to avoid crossing the crowns of Perceval frame. After exchange of the standard wire with an extra-stiff 0.035-in. Safari wire, the Sapien-3 valve was advanced across the two previously implanted surgical valves and deployed at the level of the Perceval ring. After bioprosthesis deployment, peak-to-peak left ventricular aortic gradient was reduced from 51 to 16 mmHg.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Idoso , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Hemodinâmica , Humanos , Masculino , Desenho de Prótese , Resultado do Tratamento
2.
Surg Technol Int ; 33: 219-237, 2018 Nov 11.
Artigo em Inglês | MEDLINE | ID: mdl-30204929

RESUMO

When the original monograph on valvular prostheses was published in Surgical Technology International, back in 1993, transcatheter technology had not yet been invented. These techniques have been gradually revealed in subsequent issues. When we first considered writing a paper that described both surgical and transcatheter prosthesis, we realized that such a combined paper would be impractically large. Therefore, we decided to split our survey into more than one paper. This paper seeks to address the paucity of information available regarding transcatheter aortic valve implantation (TAVI) and similar devices. This publication may serve as a reference point for critically organizing information on an evolving topic. The following article deals with the large number of transcatheter devices related to valvular and ventricular pathologies: TAVI for the aortic and mitral valves, with a focus on indications, techniques and complications, as well as specific aortic devices, and devices to treat mitral regurgitation with non-conventional access. Every effort has been made to make the content relevant and up-to-date, which proved to be particularly challenging due to the continuous technological evolution which characterizes this field.


Assuntos
Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Doenças das Valvas Cardíacas/cirurgia , Valvas Cardíacas/cirurgia , Humanos , Desenho de Prótese , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/métodos , Substituição da Valva Aórtica Transcateter/tendências
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA