Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 58
Filtrar
1.
Faraday Discuss ; 250(0): 60-73, 2024 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-37975288

RESUMO

The development of chemical sensors has advanced due to an increase in demand; however, the potential of chemical sensors as devices to monitor organic reactions has not been revealed yet. Thus, we aim to propose a chemical sensor platform for facile monitoring of chemical reactions, especially at a solid-liquid interface. In this study, an extended-gate-type organic field-effect transistor (OFET) has been employed as a platform to detect chemical reactions at an interface between the extended-gate electrode and an aqueous solution. The OFET device functionalized with 4,4'-thiobisbenzenthiol has shown time- and concentration-dependent shifts in transistor characteristics upon adding H2O2. In a selectivity test using seven oxidant agents, the transistor responses depended on the oxidation of the organic sulfur compound (i.e., 4,4'-thiobisbenzenthiol) stemming from the ability of the oxidant agents. Therefore, the observed changes in the transistor characteristics have suggested the generation of sulfur-oxidized products at the interface. In this regard, the observed responses were caused by disulfide formation accompanied by changes in the charges under neutral pH conditions. Meanwhile, weak transistor responses derived from the generation of oxygen adducts have also been observed, which were caused by changes in the dipole moments. Indeed, the yields of the oxygen adducts have been revealed by X-ray photoelectron spectroscopy. The monitoring of gradual changes originating from the decrease in the disulfide formation and the increase in the oxygen adducts implied a novel aspect of the OFET device as a platform to simultaneously detect reversible and irreversible reactions at interfaces without using large-sized analytical instruments. Sulfur oxidation by H2O2 on the OFET device has been further applied to the indirect monitoring of an enzymatic reaction in solution. The OFET-based chemical sensor has shown continuous changes with an increase in a substance (i.e., lactate) in the presence of an enzyme (i.e., lactate oxidase), which indicates that the OFET response depends on the H2O2 generated through the enzymatic reaction in the solution. In this study, we have clarified the versatility of organic devices as platforms to monitor different chemical reactions using a single detection method.

2.
Analyst ; 147(6): 1055-1059, 2022 Mar 14.
Artigo em Inglês | MEDLINE | ID: mdl-35191913

RESUMO

Herein, we report an extended-gate-type organic field-effect transistor (OFET) sensor for oxytocin. The fabricated OFET-based immunosensor has successfully detected oxytocin at a ppt level in human saliva with high recovery rates (96-102%). We believe our sensor would pave the way for the realization of portable sensors for healthcare monitoring.


Assuntos
Técnicas Biossensoriais , Ocitocina , Eletrodos , Humanos , Imunoensaio , Saliva , Transistores Eletrônicos
3.
Anal Chem ; 93(2): 1179-1184, 2021 01 19.
Artigo em Inglês | MEDLINE | ID: mdl-33320543

RESUMO

Simple, rapid, and accurate detection methods for saccharides are potentially applicable to various fields such as clinical and food chemistry. However, the practical applications of on-site analytical methods are still limited. To this end, herein, we propose a 96-well microtiter plate made of paper as a paper-based chemosensor array device (PCSAD) for the simultaneous classification of 12 saccharides and the quantification of fructose and glucose among 12 saccharides. The mechanism of the saccharide detection relied on an indicator displacement assay (IDA) on the PCSAD using four types of catechol dyes, 3-nitrophenylboronic acid, and the saccharides. The design of the PCSAD and the experimental conditions for the IDA were optimized using a central composite design. The chemosensors exhibited clear color changes upon the addition of saccharides on the paper because of the competitive boronate esterification. The color changes were employed for the subsequent qualitative, semiquantitative, and quantitative analyses using an automated algorithm combined with pattern recognition for digital images. A qualitative linear discrimination analysis offered discrimination of 12 saccharides with a 100% classification rate. The semiquantitative analysis of fructose in the presence of glucose was carried out from the viewpoint of food analysis utilizing a support vector machine, resulting in clear discrimination of the various concentrations of fructose. Most importantly, the quantitative detection of fructose in two types of commercial soft drinks was also successfully carried out without sample pretreatments. Thus, the proposed PCSAD can be a powerful method for on-site food analyses that can meet the increasing demand from consumers for sensors of saccharides.


Assuntos
Ácidos Borônicos/química , Catecóis/química , Colorimetria , Corantes Fluorescentes/química , Papel , Acetilglucosamina/análise , Arabinose/análise , Frutose/análise , Fucose/análise , Galactose/análise , Glucose/análise , Ramnose/análise , Ribose/análise , Espectrometria de Fluorescência , Xilose/análise
4.
Chemistry ; 26(64): 14525-14529, 2020 Nov 17.
Artigo em Inglês | MEDLINE | ID: mdl-32803889

RESUMO

This work reports the design of a highly sensitive solid-state sensor device based on a water-gated organic thin-film transistor (WG-OTFT) for the selective detection of herbicide glyphosate (GlyP) in water. A competitive assay among carboxylate-functionalized polythiophene, Cu2+ , and GlyP was employed as a sensing mechanism. Molecular recognition phenomena and electrical double layer (EDL) (at the polymer/water interface) originated from the field-effect worked cooperatively to amplify the sensitivity for GlyP. The limit of detection of WG-OTFT (0.26 ppm) was lower than that of a fluorescence sensor chip (0.95 ppm) which is the conventional sensing method. In contrast to the previously reported insulated molecular wires to block interchain interactions, molecular aggregates under the field-effect has shown to be effective for amplification of sensitivity through "intra"- and "inter"-molecular wire effects. The opposite strategy in this study could pave the way for fully utilizing the sensing properties of polymer-based solid-state sensor devices.


Assuntos
Herbicidas , Água , Fluorescência , Glicina/análogos & derivados , Glicina/análise , Glicina/química , Herbicidas/química , Glifosato
5.
Chemistry ; 26(64): 14506, 2020 Nov 17.
Artigo em Inglês | MEDLINE | ID: mdl-33053248

RESUMO

Invited for the cover of this issue is the group of Tsuyoshi Minami at the University Tokyo. The image illustrates that despite being fabricated with the same polythiophene material, a water-gated organic thin-film transistor is a more sensitive device than a fluorescence sensor chip. Read the full text of the article at 10.1002/chem.202003529.


Assuntos
Água , Fluorescência , Glicina/análogos & derivados , Humanos , Glifosato
6.
Chemistry ; 26(69): 16236-16240, 2020 Dec 09.
Artigo em Inglês | MEDLINE | ID: mdl-32633434

RESUMO

An artificial tongue that detects astringent components for a comprehensive evaluation of taste has not been established to date. Herein, we first propose fluorescent polythiophene (PT) derivatives (S1-S3) modified with 3-pyridinium boronic acid as supramolecular chemosensors for wine components including astringent procyanidin C1. After numerous attempts for the synthetic conditions, more than 95 mol % of the PT unit was modified with the pyridinium boronic acid moiety. To evaluate the PT derivatives as chemosensors of the artificial tongue, qualitative and quantitative analyses were performed with four types of wine components (i.e., sweet, sour, bitter, and astringent tastes) in combination with pattern recognition models. Notably, procyanidin C1 in the actual wine sample was successfully detected in a quantitative manner. In other words, we have established an authentic artificial tongue using PT based supramolecular chemosensors.

7.
Anal Chem ; 91(21): 13627-13632, 2019 11 05.
Artigo em Inglês | MEDLINE | ID: mdl-31556601

RESUMO

Although the determination of oxyanions due to correlation with metabolic processes and diseases is in high demand, most of the developed methods are suffering from a shortage of a capability of on-site analysis, sensitivity, and user-friendliness. This paper introduces the first colorimetric chemosensor array targeting various anions including glyphosate. The proposed sensor benefits from some notable features such as utilizing only commercially available reagents, recognizing similarly structured compounds by biomaterial-free sensors, and providing a fingerprint-like response originating from pattern recognition. The detection mechanism is based on an anion sensing strategy named coordination binding-based sensor array (CBSA). In CBSA, competitive coordinative bonding of a metal ion (Zn2+) between a catechol dye (i.e., indicator) and target anions occurs, and changes in the optical properties of the dye represent the target's concentration. For data processing, two chemometrical techniques including linear discrimination analysis (LDA) and an artificial neural network (ANN) for pattern classification and regression/prediction purposes were successfully employed, respectively. Finally, the proposed chemosensor was subjected to glyphosate samples (commercial herbicide and tap water samples) and produced satisfactory results.


Assuntos
Ânions/química , Colorimetria/instrumentação , Glicina/análogos & derivados , Herbicidas/análise , Glicina/análise , Espectrofotometria Ultravioleta , Zinco/química , Glifosato
8.
Anal Chem ; 91(24): 15570-15576, 2019 12 17.
Artigo em Inglês | MEDLINE | ID: mdl-31714059

RESUMO

We believe that "the simpler we are, the more complete we become" is a key concept of chemical sensing systems. In this work, a "turn-on" fluorescence chemosensor array relying on only two self-assembled molecular chemosensors with ability of both qualitative and quantitative detection of phosphorylated saccharides has been developed. The easy-to-prepare chemosensor array was fabricated by in situ mixing of off-the-shelf reagents (esculetin, 4-methylesculetin, and 3-nitrophenylboronic acid). The fluorescence-based saccharide sensing system was carried out using indicator displacement assay accompanied by photoinduced electron transfer (PeT) under various pH conditions. The simultaneous recognition of 14 types of saccharides including glucose-6-phosphate (G6P) and fructose-6-phosphate (F6P) was achieved with a successful classification rate of 100%. We also succeeded in the quantitative analysis of a mixture of glucose (Glc), as an original substrate, G6P and F6P, as enzymatic products in pseudoglycolysis pathway. Finally, levels of Glc and F6P in human induced pluripotent stem (hiPS) cells were indirectly monitored by using our proposed chemosensor array. Glc and F6P in supernatants of hiPS cells were classified by linear discriminant analysis as a pattern recognition model and the observed clusters represent the activity of hiPS cells. The results show the high accuracy of the proposed chemosensor array in detection of phosphorylated and similarly modified saccharides.


Assuntos
Técnicas Biossensoriais/métodos , Ácidos Borônicos/química , Frutosefosfatos/análise , Glucose-6-Fosfato/análise , Glucose/análise , Células-Tronco Pluripotentes Induzidas/metabolismo , Células Cultivadas , Fluorescência , Frutosefosfatos/química , Glucose/química , Glucose-6-Fosfato/química , Humanos , Células-Tronco Pluripotentes Induzidas/citologia , Fosforilação
11.
BMC Complement Altern Med ; 18(1): 238, 2018 Aug 13.
Artigo em Inglês | MEDLINE | ID: mdl-30103722

RESUMO

BACKGROUND: In Korea, there are two types of medical doctors: one practises conventional medicine (hereafter called a physician), and the other practises traditional medicine (hereafter called a Korean medical doctor). This study aimed to compare the provision of complementary and alternative medicine (CAM) by these providers to CAM use per self-judgement in Korea. METHODS: We analysed 1668 Korean people via an internet survey with the Korean adopted version of the I-CAM-Q, namely, the International Questionnaire to measure use of CAM, to understand whether respondents used CAM based either on a prescription or advice from a physician or a Korean medical doctor or on self-judgement. RESULTS: In the previous 12 months, the proportions of respondents who were treated by a physician, who were treated by a Korean medical doctor and who were not treated by anyone were 67.9, 20.7 and 14.2%, respectively. Among the respondents who received CAM based on a prescription or advice from a physician, traditional Korean medicine practices and dietary supplements were commonly used; only a small percentage used other CAM therapies. Respondents who received CAM based on a prescription or advice from a Korean medical doctor showed similar results. Acupuncture and moxibustion, traditional Korean medicines (decoction), or cupping were more commonly used. Korean traditional medicines as over-the-counter (OTC) drugs were more commonly used by respondents who received CAM therapy based on a prescription or advice from a physician than by those who received CAM therapy based on a prescription or advice from a Korean medical doctor. A total of 74% of the responders used any CAM by self-judgement in the previous 12 months. CONCLUSIONS: For the use of CAM in Korea, in addition to the Korean traditional medical care provided by Korean medical doctors, general physicians advised people regarding Korean traditional medical care and dietary supplements.


Assuntos
Terapias Complementares/estatística & dados numéricos , Internet , Inquéritos e Questionários , Adulto , Estudos Transversais , Feminino , Pessoal de Saúde/estatística & dados numéricos , Humanos , Masculino , Pessoa de Meia-Idade , República da Coreia/epidemiologia , Adulto Jovem
12.
Sensors (Basel) ; 16(12)2016 Nov 30.
Artigo em Inglês | MEDLINE | ID: mdl-27916899

RESUMO

Herein, we report on the fabrication of an extended-gated organic field-effect transistor (OFET)-based immunosensor and its application in the detection of human chromogranin A (hCgA). The fabricated OFET device possesses an extended-gate electrode immobilized with an anti-CgA antibody. The titration results of hCgA showed that the electrical changes in the OFET characteristics corresponded to the glycoprotein recognition ability of the monoclonal antibody (anti-CgA). The observed sensitivity (detection limit: 0.11 µg/mL) and selectivity indicate that the OFET-based immunosensor can be potentially applied to the rapid detection of the glycoprotein concentration without any labeling.


Assuntos
Técnicas Biossensoriais/métodos , Glicoproteínas/análise , Compostos Orgânicos/química , Transistores Eletrônicos , Anticorpos Monoclonais/química , Anticorpos Monoclonais/imunologia , Cromogranina A/química , Cromogranina A/imunologia , Glicoproteínas/química , Humanos
13.
Anal Chim Acta ; 1313: 342741, 2024 Jul 18.
Artigo em Inglês | MEDLINE | ID: mdl-38862204

RESUMO

Sensor arrays, which draw inspiration from the mammalian olfactory system, are fundamental concepts in high-throughput analysis based on pattern recognition. Although numerous optical sensor arrays for various targets in aqueous media have demonstrated their diverse applications in a wide range of research fields, practical device platforms for on-site analysis have not been satisfactorily established. The significant limitations of these sensor arrays lie in their solution-based platforms, which require stationary spectrophotometers to record the optical responses in chemical sensing. To address this, this review focuses on paper substrates as device components for solid-state sensor arrays. Paper-based sensor arrays (PSADs) embedded with multiple detection sites having cross-reactivity allow rapid and simultaneous chemical sensing using portable recording apparatuses and powerful data-processing techniques. The applicability of office printing technologies has promoted the realization of PSADs in real-world scenarios, including environmental monitoring, healthcare diagnostics, food safety, and other relevant fields. In this review, we discuss the methodologies of device fabrication and imaging analysis technologies for pattern recognition-driven chemical sensing in aqueous media.

14.
PLoS One ; 19(6): e0300938, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38829863

RESUMO

PURPOSE: To clarify the morphological factors of the pelvis in patients with developmental dysplasia of the hip (DDH), three-dimensional (3D) pelvic morphology was analyzed using a template-fitting technique. METHODS: Three-dimensional pelvic data of 50 patients with DDH (DDH group) and 3D pelvic data of 50 patients without obvious pelvic deformity (Normal group) were used. All patients were female. A template model was created by averaging the normal pelvises into a symmetrical and isotropic mesh. Next, 100 homologous models were generated by fitting the pelvic data of each group of patients to the template model. Principal component analysis was performed on the coordinates of each vertex (15,235 vertices) of the pelvic homologous model. In addition, a receiver-operating characteristic (ROC) curve was calculated from the sensitivity of DDH positivity for each principal component, and principal components for which the area under the curve was significantly large were extracted (p<0.05). Finally, which components of the pelvic morphology frequently seen in DDH patients are related to these extracted principal components was evaluated. RESULTS: The first, third, and sixth principal components showed significantly larger areas under the ROC curves. The morphology indicated by the first principal component was associated with a decrease in coxal inclination in both the coronal and horizontal planes. The third principal component was related to the sacral inclination in the sagittal plane. The sixth principal component was associated with narrowing of the superior part of the pelvis. CONCLUSION: The most important factor in the difference between normal and DDH pelvises was the change in the coxal angle in both the coronal and horizontal planes. That is, in the anterior and superior views, the normal pelvis is a triangle, whereas in DDH, it was more like a quadrilateral.


Assuntos
Displasia do Desenvolvimento do Quadril , Imageamento Tridimensional , Curva ROC , Humanos , Feminino , Displasia do Desenvolvimento do Quadril/patologia , Displasia do Desenvolvimento do Quadril/diagnóstico por imagem , Imageamento Tridimensional/métodos , Análise de Componente Principal , Ossos Pélvicos/diagnóstico por imagem , Pelve/patologia , Pelve/diagnóstico por imagem , Modelos Anatômicos , Luxação Congênita de Quadril/diagnóstico por imagem , Luxação Congênita de Quadril/patologia
15.
RSC Adv ; 14(8): 5159-5166, 2024 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-38332791

RESUMO

π-Conjugated polymers such as polythiophene provide intramolecular wire effects upon analyte capture, which contribute to sensitive detection in chemical sensing. However, inherent aggregation-induced quenching causes difficulty in fluorescent chemical sensing in the solid state. Herein, we propose a solid-state fluorescent chemosensor array device made of a paper substrate (PCSAD) for the qualitative and quantitative detection of metal ions. A polythiophene derivative modified by dipicolylamine moieties (1poly), which shows optical changes upon the addition of target metal ions (i.e., Cu2+, Cd2+, Ni2+, Co2+, Pb2+, Zn2+, and Hg2+), was highly dispersed on the paper substrate using office apparatus. In this regard, morphological observation of the PCSAD after printing of 1poly suggested the contribution of the fiber structures of the paper substrate to the homogeneous dispersion of 1poly ink to suppress aggregation-induced quenching. The optical changes in the PCSAD upon the addition of metal ions was rapidly recorded using a smartphone, which was further applied to imaging analysis and pattern recognition techniques for high-throughput sensing. Indeed, the printed PCSAD embedded with 1poly achieved the accurate detection of metal ions at ppm levels contained in river water. The limit of detection of the PCSAD-based sensing system using a smartphone (48 ppb for Cu2+ ions) is comparable to that of a solution-based sensing system using a stationary spectrophotometer (16 ppb for Cu2+ ions). Therefore, the methodology based on a combination of a paper-based sensor array and a π-conjugated polymer will be a promising approach for solid-state fluorescent chemosensors.

16.
Arch Gerontol Geriatr ; 119: 105322, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38171032

RESUMO

OBJECTIVES: This study aimed to determine the longitudinal associations of the coexistence of frailty and depressive symptoms with mortality among older adults. METHODS: The study participants were community-dwelling older adults aged ≥65 years who participated in the baseline survey of the Kashiwa Cohort Study in Japan in 2012. We used Fried's frailty phenotype criteria to classify participants as non-frail (score = 0), pre-frail (1 or 2), or frail (≥3). Depressive symptoms were assessed using the GDS-15 (≥6 points). Cox proportional hazards models were used to evaluate the association of co-occurring frailty and depressive symptoms with all-cause mortality, after adjusting for sociodemographic and clinical characteristics. RESULTS: The study included 1920 participants, including 810 non-frail, 921 pre-frail, and 189 frail older adults, of which 9.0 %, 15.7 %, and 36.0 %, respectively, had depressive symptoms. Ninety-one (4.7 %) participants died during the average follow-up period of 4.8 years. Compared with non-frail participants without depressive symptoms, frail participants had greater adjusted hazard ratios for mortality: 2.47 (95 % CI, 1.16 to 5.25) for frail participants without depressive symptoms and 4.34 (95 % CI, 1.95 to 9.65) for frail participants with depressive symptoms. However, no statistically significant associations were observed in non-frail or pre-frail participants irrespective of depressive symptoms. CONCLUSION: Frail older adults with depressive symptoms have a substantially greater risk of mortality. Screening for depressive symptoms and frailty in older adults should be incorporated into health checkups and clinical practice to identify high-risk populations.


Assuntos
Fragilidade , Idoso , Humanos , Fragilidade/complicações , Fragilidade/epidemiologia , Estudos de Coortes , Vida Independente , Depressão/complicações , Depressão/epidemiologia , Idoso Fragilizado , Avaliação Geriátrica
17.
Front Chem ; 11: 1134752, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36909708

RESUMO

Here, we propose a printed 96-well microtiter paper-based chemosensor array device (PCSAD) to simultaneously detect metal ions for river water assessment. Colorimetric chemosensors for metal ions have been designed based on molecular self-assembly using off-the-shelf catechol dyes and a phenylboronic acid (PBA) derivative. The colorimetric self-assembled chemosensors consisting of catechol dyes and a PBA derivative on a 96-well microtiter paper substrate demonstrated various color changes according to the disassembly of the ensembles by the addition of nine types of metal ions. An in-house-made algorithm was used to automate imaging analysis and extract color intensities at seven types of color channels from a captured digital image, allowing for rapid data processing. The obtained information-rich inset data showed fingerprint-like colorimetric responses and was applied to the qualitative and quantitative pattern recognition of metal ions using chemometric techniques. The feasibility of the 96-well microtiter PCSAD for environmental assessment has been revealed by the demonstration of a spike-and-recovery test against metal ions in a river water sample.

18.
Chem Commun (Camb) ; 59(17): 2425-2428, 2023 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-36745444

RESUMO

We herein report an organic transistor functionalized with a phenylboronic acid derivative and graphene oxide for the quantification of plasma glucose levels, which has been achieved by the minimization of interferent effects derived from physical protein adsorption on the detection electrode.


Assuntos
Grafite , Humanos , Eletrodos , Glucose , Plasma , Técnicas Eletroquímicas
19.
Chem Commun (Camb) ; 59(50): 7747-7750, 2023 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-37272870

RESUMO

A self-assembled chemosensor prepared using off-the-shelf materials has shown various fluorescence responses including ratiometric and simple ON-OFF switching profiles by adding different toxic metal ions. The unique fingerprint-like responses have been applied to pattern recognition of metal ions in river water for environmental analysis.

20.
Chem Asian J ; 18(16): e202300372, 2023 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-37309739

RESUMO

Herein, we propose a novel amphiphilic polythiophene-based chemosensor functionalized with a Zn(II)-dipicolylamine side chain (1poly ⋅ Zn) for the pattern recognition of oxyanions. Optical changes in amphiphilic 1poly ⋅ Zn can be induced by the formation of a random coil from a backbone-planarized structure upon the addition of target oxyanions, which results in blueshifts in the UV-vis absorption spectra and turn-on-type fluorescence responses. Dynamic behavior in a polythiophene wire and/or among wires could be a driving force for obtaining visible color changes, while the molecular wire effect is dominant in obtaining fluorescence sensor responses. Notably, the magnitude of optical changes in 1poly ⋅ Zn has depended on differences in properties of oxyanions, such as their binding affinity, hydrophilicity, and molecular geometry. Thus, various colorimetric and fluorescence response patterns of 1poly ⋅ Zn to oxyanions were obtained, albeit using a single chemosensor. A constructed information-rich dataset was applied to pattern recognition for the simultaneous group categorization of phosphate and carboxylate groups and the prediction of similar structural oxyanions at a different order of concentrations in their mixture solutions.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA