Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
1.
Gastroenterology ; 156(6): 1717-1730, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30689971

RESUMO

BACKGROUND & AIMS: We estimated the accuracy of FibroScan vibration-controlled transient elastography controlled attenuation parameter (CAP) and liver stiffness measurement (LSMs) in assessing steatosis and fibrosis in patients with suspected nonalcoholic liver disease (NAFLD). METHODS: We collected data from 450 consecutive adults who underwent liver biopsy analysis for suspected NAFLD at 7 centers in the United Kingdom from March 2014 through January 2017. FibroScan examinations with M or XL probe were completed within the 2 weeks of the biopsy analysis (404 had a valid examination). The biopsies were scored by 2 blinded expert pathologists according to nonalcoholic steatohepatitis clinical research network criteria. Diagnostic accuracy was estimated using the area under the receiver operating characteristic curves (AUROCs) for the categories of steatosis and fibrosis. We assessed effects of disease prevalence on positive and negative predictive values. For LSM, the effects of histological parameters and probe type were appraised using multivariable analysis. RESULTS: Using biopsy analysis as the reference standard, we found that CAP identified patients with steatosis with an AUROC of 0.87 (95% confidence interval [CI] 0.82-0.92) for S≥S1, 0.77 (95% CI 0.71-0.82) for S≥S2, and 0.70 (95% CI 0.64-0.75) for S=S3. Youden cutoff values for S≥S1, S≥S2, and S≥S3 were 302 dB/m, 331 dB/m, and 337 dB/m, respectively. LSM identified patients with fibrosis with AUROCs of 0.77 (95% CI 0.72-0.82) for F≥F2, 0.80 (95% CI 0.75-0.84) for F≥F3, and 0.89 (95% CI 0.84-0.93) for F=F4. Youden cutoff values for F≥F2, F≥F3, and F=F4 were 8.2 kPa, 9.7 kPa, and 13.6 kPa, respectively. Applying the optimal cutoff values, determined from this cohort, to populations of lower fibrosis prevalence increased negative predictive values and reduced positive predictive values. Multivariable analysis found that the only parameter that significantly affected LSMs was fibrosis stage (P<10-16); we found no association with steatosis or probe type. CONCLUSIONS: In a prospective analysis of patients with NAFLD, we found CAP and LSM by FibroScan to assess liver steatosis and fibrosis, respectively, with AUROC values ranging from 0.70 to 0.89. Probe type and steatosis did not affect LSM. STUDY REGISTRATION: ClinicalTrials.gov Identifier: NCT01985009.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Elasticidade , Cirrose Hepática/diagnóstico por imagem , Hepatopatia Gordurosa não Alcoólica/diagnóstico por imagem , Adulto , Idoso , Área Sob a Curva , Biópsia , Técnicas de Imagem por Elasticidade/instrumentação , Feminino , Humanos , Fígado/diagnóstico por imagem , Fígado/patologia , Cirrose Hepática/etiologia , Cirrose Hepática/patologia , Masculino , Pessoa de Meia-Idade , Hepatopatia Gordurosa não Alcoólica/complicações , Hepatopatia Gordurosa não Alcoólica/patologia , Valor Preditivo dos Testes , Estudos Prospectivos , Curva ROC , Adulto Jovem
2.
J Hepatol ; 66(5): 1022-1030, 2017 05.
Artigo em Inglês | MEDLINE | ID: mdl-28039099

RESUMO

BACKGROUND & AIMS: The prevalence of fatty liver underscores the need for non-invasive characterization of steatosis, such as the ultrasound based controlled attenuation parameter (CAP). Despite good diagnostic accuracy, clinical use of CAP is limited due to uncertainty regarding optimal cut-offs and the influence of covariates. We therefore conducted an individual patient data meta-analysis. METHODS: A review of the literature identified studies containing histology verified CAP data (M probe, vibration controlled transient elastography with FibroScan®) for grading of steatosis (S0-S3). Receiver operating characteristic analysis after correcting for center effects was used as well as mixed models to test the impact of covariates on CAP. The primary outcome was establishing CAP cut-offs for distinguishing steatosis grades. RESULTS: Data from 19/21 eligible papers were provided, comprising 3830/3968 (97%) of patients. Considering data overlap and exclusion criteria, 2735 patients were included in the final analysis (37% hepatitis B, 36% hepatitis C, 20% NAFLD/NASH, 7% other). Steatosis distribution was 51%/27%/16%/6% for S0/S1/S2/S3. CAP values in dB/m (95% CI) were influenced by several covariates with an estimated shift of 10 (4.5-17) for NAFLD/NASH patients, 10 (3.5-16) for diabetics and 4.4 (3.8-5.0) per BMI unit. Areas under the curves were 0.823 (0.809-0.837) and 0.865 (0.850-0.880) respectively. Optimal cut-offs were 248 (237-261) and 268 (257-284) for those above S0 and S1 respectively. CONCLUSIONS: CAP provides a standardized non-invasive measure of hepatic steatosis. Prevalence, etiology, diabetes, and BMI deserve consideration when interpreting CAP. Longitudinal data are needed to demonstrate how CAP relates to clinical outcomes. LAY SUMMARY: There is an increase in fatty liver for patients with chronic liver disease, linked to the epidemic of the obesity. Invasive liver biopsies are considered the best means of diagnosing fatty liver. The ultrasound based controlled attenuation parameter (CAP) can be used instead, but factors such as the underlying disease, BMI and diabetes must be taken into account. Registration: Prospero CRD42015027238.


Assuntos
Fígado Gorduroso/diagnóstico por imagem , Ultrassonografia , Adulto , Índice de Massa Corporal , Fígado Gorduroso/patologia , Feminino , Hepatócitos/patologia , Humanos , Masculino , Metanálise como Assunto , Pessoa de Meia-Idade , Curva ROC
3.
Mycoses ; 60(12): 770-780, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28758337

RESUMO

Monitoring fungal ecology and resistance to antifungal agents within intensive care units (ICU) is essential for the management of invasive fungal infections. Therefore, a retrospective descriptive study was carried in the ICU of Nimes University Hospital, France, from 2007 to 2016. As the majority of invasive fungal infections in ICU are caused by Candida species, the study objectives were to describe Candida species distribution, to assess candidaemia incidence and to monitor the antifungal drug susceptibility of Candida isolates and the consumption of antifungal agents. Among the recorded invasive Candida infections (n=244), 43% were intra-abdominal and 22% bloodstream infections. Candida albicans was the most frequent species (55.8%), followed by Candida glabrata (14.1%), Candida tropicalis (10%), Candida parapsilosis (8%) and Candida krusei (5.3%). Candidaemia incidence was 4.49 per 1000 admissions. The mean consumption of antifungal agents was of 170.5 defined daily doses (DDD) for 1000 hospital days (HD) per year. Changes in antifungal drug consumption were observed, with an increased use of echinocandins (from 17.96 DDD/1000 HD in 2007 to 48.76 DDD/1000 HD in 2016), and the total treatment cost tripled during the study period. No significant change in fungal ecology or in the emergence of resistant species was observed; indeed, only 1.1% of isolates presented an unusual resistance to antifungal agents.


Assuntos
Antifúngicos/uso terapêutico , Candida/efeitos dos fármacos , Candidíase/tratamento farmacológico , Candidíase/epidemiologia , Candida/classificação , Candida/genética , Candida/isolamento & purificação , Candidíase/microbiologia , Farmacorresistência Fúngica , França/epidemiologia , Humanos , Unidades de Terapia Intensiva/estatística & dados numéricos , Testes de Sensibilidade Microbiana , Estudos Retrospectivos
5.
Lancet Gastroenterol Hepatol ; 6(3): 185-198, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33460567

RESUMO

BACKGROUND: Diagnostic tools for liver disease can now include estimation of the grade of hepatic steatosis (S0 to S3). Controlled attenuation parameter (CAP) is a non-invasive method for assessing hepatic steatosis that has become available for patients who are obese (FibroScan XL probe), but a consensus has not yet been reached regarding cutoffs and its diagnostic performance. We aimed to assess diagnostic properties and identify relevant covariates with use of an individual patient data meta-analysis. METHODS: We did an individual patient data meta-analysis, in which we searched PubMed and Web of Science for studies published from database inception until April 30, 2019. Studies reporting original biopsy-controlled data of CAP for non-invasive grading of steatosis were eligible. Probe recommendation was based on automated selection, manual assessment of skin-to-liver-capsule distance, and a body-mass index (BMI) criterion. Receiver operating characteristic methods and mixed models were used to assess diagnostic properties and covariates. Patients with non-alcoholic fatty liver disease (NAFLD) were analysed separately because they are the predominant patient group when using the XL probe. This study is registered with PROSPERO, CRD42018099284. FINDINGS: 16 studies reported histology-controlled CAP including the XL probe, and individual data from 13 papers and 2346 patients were included. Patients with a mean age of 46·5 years (SD 14·5) were recruited from 20 centres in nine countries. 2283 patients had data for BMI; 673 (29%) were normal weight (BMI <25 kg/m2), 530 (23%) were overweight (BMI ≥25 to <30 kg/m2), and 1080 (47%) were obese (BMI ≥30 kg/m2). 1277 (54%) patients had NAFLD, 474 (20%) had viral hepatitis, 285 (12%) had alcohol-associated liver disease, and 310 (13%) had other liver disease aetiologies. The XL probe was recommended in 1050 patients, 930 (89%) of whom had NAFLD; among the patients with NAFLD, the areas under the curve were 0·819 (95% CI 0·769-0·869) for S0 versus S1 to S3 and 0·754 (0·720-0·787) for S0 to S1 versus S2 to S3. CAP values were independently affected by aetiology, diabetes, BMI, aspartate aminotransferase, and sex. Optimal cutoffs differed substantially across aetiologies. Risk of bias according to QUADAS-2 was low. INTERPRETATION: CAP cutoffs varied according to cause, and can effectively recognise significant steatosis in patients with viral hepatitis. CAP cannot grade steatosis in patients with NAFLD adequately, but its value in a NAFLD screening setting needs to be studied, ideally with methods beyond the traditional histological reference standard. FUNDING: The German Federal Ministry of Education and Research and Echosens.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Fígado/patologia , Hepatopatia Gordurosa não Alcoólica/diagnóstico por imagem , Adulto , Área Sob a Curva , Biópsia , Índice de Massa Corporal , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Hepatopatia Gordurosa não Alcoólica/etiologia , Curva ROC , Índice de Gravidade de Doença
6.
Lancet Gastroenterol Hepatol ; 5(4): 362-373, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-32027858

RESUMO

BACKGROUND: The burden of non-alcoholic fatty liver disease (NAFLD) is increasing globally, and a major priority is to identify patients with non-alcoholic steatohepatitis (NASH) who are at greater risk of progression to cirrhosis, and who will be candidates for clinical trials and emerging new pharmacotherapies. We aimed to develop a score to identify patients with NASH, elevated NAFLD activity score (NAS≥4), and advanced fibrosis (stage 2 or higher [F≥2]). METHODS: This prospective study included a derivation cohort before validation in multiple international cohorts. The derivation cohort was a cross-sectional, multicentre study of patients aged 18 years or older, scheduled to have a liver biopsy for suspicion of NAFLD at seven tertiary care liver centres in England. This was a prespecified secondary outcome of a study for which the primary endpoints have already been reported. Liver stiffness measurement (LSM) by vibration-controlled transient elastography and controlled attenuation parameter (CAP) measured by FibroScan device were combined with aspartate aminotransferase (AST), alanine aminotransferase (ALT), or AST:ALT ratio. To identify those patients with NASH, an elevated NAS, and significant fibrosis, the best fitting multivariable logistic regression model was identified and internally validated using boot-strapping. Score calibration and discrimination performance were determined in both the derivation dataset in England, and seven independent international (France, USA, China, Malaysia, Turkey) histologically confirmed cohorts of patients with NAFLD (external validation cohorts). This study is registered with ClinicalTrials.gov, number NCT01985009. FINDINGS: Between March 20, 2014, and Jan 17, 2017, 350 patients with suspected NAFLD attending liver clinics in England were prospectively enrolled in the derivation cohort. The most predictive model combined LSM, CAP, and AST, and was designated FAST (FibroScan-AST). Performance was satisfactory in the derivation dataset (C-statistic 0·80, 95% CI 0·76-0·85) and was well calibrated. In external validation cohorts, calibration of the score was satisfactory and discrimination was good across the full range of validation cohorts (C-statistic range 0·74-0·95, 0·85; 95% CI 0·83-0·87 in the pooled external validation patients' cohort; n=1026). Cutoff was 0·35 for sensitivity of 0·90 or greater and 0·67 for specificity of 0·90 or greater in the derivation cohort, leading to a positive predictive value (PPV) of 0·83 (84/101) and a negative predictive value (NPV) of 0·85 (93/110). In the external validation cohorts, PPV ranged from 0·33 to 0·81 and NPV from 0·73 to 1·0. INTERPRETATION: The FAST score provides an efficient way to non-invasively identify patients at risk of progressive NASH for clinical trials or treatments when they become available, and thereby reduce unnecessary liver biopsy in patients unlikely to have significant disease. FUNDING: Echosens and UK National Institute for Health Research.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Fibrose/patologia , Fígado/patologia , Hepatopatia Gordurosa não Alcoólica/diagnóstico por imagem , Hepatopatia Gordurosa não Alcoólica/patologia , Adulto , Alanina Transaminase/análise , Aspartato Aminotransferases/análise , Biópsia , China/epidemiologia , Estudos de Coortes , Estudos Transversais , Progressão da Doença , Inglaterra/epidemiologia , Feminino , Fibrose/classificação , França/epidemiologia , Humanos , Fígado/metabolismo , Cirrose Hepática/epidemiologia , Cirrose Hepática/etiologia , Malásia/epidemiologia , Masculino , Pessoa de Meia-Idade , Hepatopatia Gordurosa não Alcoólica/complicações , Hepatopatia Gordurosa não Alcoólica/epidemiologia , Valor Preditivo dos Testes , Estudos Prospectivos , Sensibilidade e Especificidade , Turquia/epidemiologia , Estados Unidos/epidemiologia
7.
J Biomech ; 41(2): 347-55, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18028934

RESUMO

The development of the axial transmission technique now enables in vivo evaluation of cortical bone quality, which plays an important role in bone fragility. Cortical bone is a complex multiscale material, which may be made of different types of microstructure. The interaction between ultrasound and cortical bone remains unclear and most studies have been confined to wave speed analysis. The first aim of this study is to investigate the dependence of the frequency-dependent attenuation on the type of bone microstructure. The second goal is to determine whether broadband ultrasonic attenuation (BUA) is related to volumetric bone mineral density (vBMD) and mass density. Parallelepipedic samples of bovine cortical bone were cut from three specimens and tested in the axial, radial and tangential directions using an ultrasonic transmission device. BUA was evaluated over a 1-MHz wide bandwidth around 4MHz. In addition, the microstructure of each sample was determined using an optical microscope. BUA values measured in porotic microstructure are significantly higher than in Haversian microstructure. The lowest BUA values are obtained for plexiform microstructure. For all structures, BUA in the axial direction is significantly smaller than in the radial and tangential directions. Moreover, BUA is correlated with both vBMD and density (determination coefficient (R2) equal to 0.44 and 0.65, respectively, in the axial direction). BUA variations can be explained by scattering and viscoelastic mechanisms. This study suggests that BUA measurements have the potential to discriminate among different cortical bone microstructures in addition to providing material properties.


Assuntos
Osso e Ossos/diagnóstico por imagem , Osso e Ossos/fisiologia , Calcificação Fisiológica/fisiologia , Modelos Biológicos , Radiometria/métodos , Animais , Anisotropia , Osso e Ossos/citologia , Bovinos , Simulação por Computador , Técnicas In Vitro , Tamanho do Órgão/fisiologia , Doses de Radiação , Espalhamento de Radiação , Estatística como Assunto , Ultrassonografia
8.
J Acoust Soc Am ; 124(3): 1811-21, 2008 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-19045671

RESUMO

Cortical bone quality is determinant in bone fragility and its ultrasonic evaluation has become possible in clinical practice. However, the interaction between a broadband ultrasonic pulse and this complex multiscale medium remains poorly understood. The frequency dependence of phase velocity, which may impact clinical measurements, has been sparsely investigated. Our objective is to evaluate the determinants of the frequency dependence of phase velocity in bovine femoral cortical bone samples using an in vitro ultrasonic transmission device. The apparent phase velocity varies quasilinearly on a 1 MHz restricted bandwidth around 4 MHz. After compensating for diffraction effects, significant differences in velocity dispersion are obtained according to the anatomical location. The microstructure of each sample is determined using an optical microscope, which allows assessing the dependence of dispersion on the type of bone microstructure. Mostly positive but also negative values of dispersion are measured. Negative dispersion is mainly obtained in samples constituted of mixed microstructure, which may be explained by phase cancellation effects due to the presence of different microstructures within the same sample. Dispersion is shown to be related to broadband ultrasonic attenuation values, especially in the radial direction. Results are compared with the local Kramers-Kronig relationships.


Assuntos
Fêmur/diagnóstico por imagem , Absorciometria de Fóton , Animais , Densidade Óssea , Bovinos , Estudos de Viabilidade , Fêmur/anatomia & histologia , Modelos Biológicos , Porosidade , Fatores de Tempo , Ultrassonografia
9.
Ultrasound Med Biol ; 33(12): 1933-42, 2007 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-17681677

RESUMO

Recent progress in quantitative ultrasonic (QUS) techniques enables the in vivo evaluation of cortical bone, which is determinant in bone fragility. However, the interaction between ultrasound and cortical bone remains poorly understood. Most ultrasonic studies have been confined to longitudinal wave speed analysis and the frequency dependence of ultrasonic wave attenuation in this complex multiscale structure has not been extensively investigated. Our objective was to evaluate in vitro the frequency dependence of attenuation in bovine femoral cortical bone samples obtained from three specimens at different anatomical locations along the diaphysis axis and around the circumference. The frequency-dependent attenuation coefficient was evaluated after correction of transmission effects using a transmission device operating at 10 MHz. Attenuation exhibits a non linear variation versus frequency. However, the quasi-linearity of attenuation on a 1 MHz restricted bandwidth around 4 MHz enables broadband ultrasonic attenuation (BUA) evaluation. Our study demonstrates the feasibility of BUA measurements in the three directions (axial, radial and tangential) with reasonable precision (standardized coefficient of variation: 10% to 12%). Significant differences in BUA are obtained according to the anatomical location. BUA values are higher in the distal and proximal parts of the bone than in the midshaft and in the posterior and lateral parts than in the medial and anterior parts. Findings are consistent with results previously obtained and may be explained primarily by scattering phenomena but also by bone viscoelasticity.


Assuntos
Osso e Ossos/diagnóstico por imagem , Animais , Osso e Ossos/anatomia & histologia , Osso e Ossos/fisiologia , Bovinos , Elasticidade , Estudos de Viabilidade , Fêmur/anatomia & histologia , Fêmur/diagnóstico por imagem , Fêmur/fisiologia , Técnicas In Vitro , Reprodutibilidade dos Testes , Ultrassonografia , Viscosidade
10.
Ultrasound Med Biol ; 42(1): 92-103, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26386476

RESUMO

To assess liver steatosis, the controlled attenuation parameter (CAP; giving an estimate of ultrasound attenuation ∼3.5 MHz) is available with the M probe of the FibroScan. We report on the adaptation of the CAP for the FibroScan XL probe (center frequency 2.5 MHz) without modifying the range of values (100-400 dB/m). CAP validation was successfully performed on Field II simulations and on tissue-mimicking phantoms. In vivo performance was assessed in a cohort of 59 patients spanning the range of steatosis. In vivo reproducibility was good and similar with both probes. The area under receiver operative characteristic curve was equal to 0.83/0.84 and 0.92/0.91 for the M/XL probes to detect >2% and >16% liver fat, respectively, as assessed by magnetic resonance imaging. Patients can now be assessed simultaneously for steatosis and fibrosis using the FibroScan, regardless of their morphology.


Assuntos
Fígado Gorduroso/diagnóstico por imagem , Ultrassonografia/instrumentação , Ultrassonografia/métodos , Área Sob a Curva , Estudos de Coortes , Feminino , Humanos , Fígado/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Projetos Piloto , Curva ROC , Reprodutibilidade dos Testes
11.
Ultrasound Med Biol ; 42(10): 2401-13, 2016 10.
Artigo em Inglês | MEDLINE | ID: mdl-27471115

RESUMO

We describe a novel device called the AdipoScan that was adapted from the FibroScan to specifically assess shear wave speed (SWS) in human abdominal subcutaneous adipose tissue (scAT). Measurement reproducibility was assessed on tissue-mimicking phantoms with and without repositioning, with resultant coefficients of variation of 1% and 0%, respectively, as well as in vivo (14% and 7%, respectively). The applicability of the AdipoScan was tested on 19 non-obese volunteers, and a scAT thickness >2 cm was found to be mandatory to perform a valid measurement. Abdominal scAT SWS was assessed in 73 severely obese subjects, all candidates for bariatric surgery. Subcutaneous AT SWS was positively associated with scAT fibrosis and obesity-related co-morbidities such as hypertension, glycemic status, dyslipidemia and liver dysfunction. These results suggest that the AdipoScan could be a useful non-invasive tool to evaluate scAT fibrosis and metabolic complications in obesity. Further investigation is required to evaluate the relevance of using the AdipoScan to predict patient weight trajectories and metabolic outcomes after bariatric surgery.


Assuntos
Técnicas de Imagem por Elasticidade/instrumentação , Técnicas de Imagem por Elasticidade/métodos , Obesidade/diagnóstico por imagem , Gordura Subcutânea/diagnóstico por imagem , Gordura Abdominal/diagnóstico por imagem , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Reprodutibilidade dos Testes
12.
J Clin Endocrinol Metab ; 101(1): 293-304, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26583585

RESUMO

CONTEXT: Extracellular matrix (ECM) in sc adipose tissue (scAT) undergoes pathological remodeling during obesity. However, its evolution during weight loss remains poorly explored. OBJECTIVE: The objective of the investigation was to study the histological, transcriptomic, and physical characteristics of scAT ECM remodeling during the first year of bariatric surgery (BS)-induced weight loss and their relationships with metabolic and bioclinical improvements. DESIGN, SETTING, PATIENTS, AND INTERVENTIONS: A total of 118 morbidly obese candidates for BS were recruited and followed up during 1 year after BS. MAIN OUTCOME MEASURES: scAT surgical biopsy and needle aspiration as well as scAT stiffness measurement were performed in three subgroups before and after BS. Fourteen nonobese, nondiabetic subjects served as controls. RESULTS: Significantly increased picrosirius-red-stained collagen accumulation in scAT after BS was observed along with fat mass loss, despite metabolic and inflammatory improvements and undetectable changes of scAT stiffness. Collagen accumulation positively associated with M2-macrophages (CD163(+) cells) before BS but negatively afterward. Expression levels of genes encoding ECM components (eg, COL3A1, COL6A1, COL6A2, ELN), cross-linking enzymes (eg, lysyl oxidase [LOX], LOXL4, transglutaminase), metalloproteinases, and their inhibitors were modified 1 year after BS. LOX expression and protein were significantly decreased and associated with decreased fat mass as well as other cross-linking enzymes. Although total collagen I and VI staining decreased 1 year after BS, we found increased degraded collagen I and III in scAT, suggesting increased degradation. CONCLUSIONS: After BS-induced weight loss and related metabolic improvements, scAT displays major collagen remodeling with an increased picrosirius-red staining that relates to increased collagen degradation and importantly decreased cross-linking. These features are in agreement with adequate ECM adaptation during fat mass loss.


Assuntos
Cirurgia Bariátrica , Colágeno/metabolismo , Gordura Subcutânea/metabolismo , Adulto , Composição Corporal , Técnicas de Imagem por Elasticidade , Matriz Extracelular/metabolismo , Proteínas da Matriz Extracelular/metabolismo , Feminino , Humanos , Macrófagos/metabolismo , Masculino , Pessoa de Meia-Idade , Obesidade Mórbida/metabolismo , Obesidade Mórbida/cirurgia , Transcriptoma , Rigidez Vascular , Redução de Peso
13.
J Clin Endocrinol Metab ; 99(3): 898-907, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24423338

RESUMO

CONTEXT: Liver and white adipose tissue (WAT) develop inflammation and fibrosis. OBJECTIVE: The aim of the study was to evaluate the bioclinical relevance of WAT fibrosis in morbid obesity and diabetes and the relationships with tissue stiffness measured using a novel device. DESIGN AND SETTING: Observational and longitudinal studies were conducted in a hospital nutrition department. PATIENTS: Biopsies of liver and subcutaneous WAT (scWAT) and omental adipose tissue were collected from 404 obese bariatric surgery candidates, of whom 243 were clinically characterized before surgery and 3, 6, and 12 months after surgery. In 123 subjects, liver and scWAT stiffness was assessed noninvasively using vibration-controlled transient elastography (VCTE). INTERVENTIONS: Bariatric surgery was performed for some patients. MAIN OUTCOME MEASURE: Adipose tissue fibrosis and stiffness and their link to obesity phenotypes were measured. RESULTS: scWAT fibrosis was positively associated with liver fibrosis (fibrosis score ≥2) (ϱ= 0.14; P = .01). VCTE-evaluated liver and scWAT stiffness was positively correlated with immunohistochemistry-determined liver (ϱ= 0.46; P = .0009) and scWAT fibrosis (ϱ= 0.48; P = .0001). VCTE-evaluated scWAT stiffness measures negatively associated with dual-energy x-ray absorptiometry-evaluated body fat mass (R = -0.25; P = .009) and were correlated with metabolic variables. Diabetic subjects showed increased scWAT stiffness. Participants less responsive to gastric bypass were older and more frequently diabetic, and they had increased body mass index, serum IL-6, and scWAT and liver fibrosis. Subjects with no diabetes and normal liver had higher fat mass and lower tissue fibrosis and stiffness. CONCLUSION: scWAT stiffness was associated with tissue fibrosis, obesity, and diabetes-related traits. Noninvasive evaluation of scWAT stiffness might be useful in clinical practice.


Assuntos
Tecido Adiposo Branco/patologia , Diabetes Mellitus Tipo 2/patologia , Derivação Gástrica , Cirrose Hepática/patologia , Obesidade Mórbida/patologia , Obesidade Mórbida/cirurgia , Redução de Peso , Adulto , Índice de Massa Corporal , Elasticidade , Técnicas de Imagem por Elasticidade , Feminino , Fibrose , Humanos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Vibração
14.
Stud Health Technol Inform ; 192: 1178, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23920952

RESUMO

Non-alcoholic fatty liver disease (NAFLD) is a hepatic disease associated with metabolic syndrome. NAFLD covers a spectrum of liver disease from steatosis to non-alcoholic steatohepatitis (NASH) and cirrhosis. NASH is a disease evolving under the influence of various stimuli still poorly understood. In this paper we present new clinical decision support system (CDSS) for the diagnosis of NASH and the comparison of this system with machine learning algorithms.


Assuntos
Inteligência Artificial , Mineração de Dados/métodos , Sistemas de Apoio a Decisões Clínicas/organização & administração , Diagnóstico por Computador/métodos , Registros Eletrônicos de Saúde/organização & administração , Hepatopatia Gordurosa não Alcoólica/diagnóstico , Obesidade Mórbida/diagnóstico , Algoritmos , Humanos , Hepatopatia Gordurosa não Alcoólica/etiologia , Obesidade Mórbida/complicações , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
15.
Ultrasound Med Biol ; 36(11): 1825-35, 2010 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-20870345

RESUMO

There is a need for noninvasive methods to detect liver steatosis, which can be a factor of liver fibrosis progression. This work aims to evaluate a novel ultrasonic controlled attenuation parameter (CAP) devised to target, specifically, liver steatosis using a sophisticated process based on vibration control transient elastography (VCTE™). CAP was first validated as an estimate of ultrasonic attenuation at 3.5 MHz using Field II simulations and tissue-mimicking phantoms. Performance of the CAP was then appraised on 115 patients, taking the histological grade of steatosis as reference. CAP was significantly correlated to steatosis (Spearman ρ = 0.81, p < 10(-16)). Area under receiver operative characteristic (ROC) curve (AUC) was equal to 0.91 and 0.95 for the detection of more than 10% and 33% of steatosis, respectively. Furthermore, results show that CAP can efficiently separate several steatosis grades. These promising results suggest that CAP is a noninvasive, immediate, objective and efficient method to detect and quantify steatosis.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Fígado Gorduroso/diagnóstico por imagem , Algoritmos , Área Sob a Curva , Doença Crônica , Estudos de Coortes , Progressão da Doença , Fígado Gorduroso/etiologia , Humanos , Imagens de Fantasmas , Projetos Piloto , Curva ROC , Reprodutibilidade dos Testes , Estatísticas não Paramétricas
16.
Artigo em Inglês | MEDLINE | ID: mdl-19942532

RESUMO

Axial transmission techniques are particularly suitable for the ultrasonic assessment of cortical bone. The generic term "axial transmission technique" indicates a measurement configuration in which emitters and receivers are placed on the same side of the skeletal site, along the bone axis. Whereas axially transmitted signals are composed of several contributions, only the first arriving signal was shown to be a robust indicator of bone status, because its velocity discriminates osteoporotic from healthy patients in clinical studies. Later arrivals may provide additional bone indicators enhancing diagnostic value, but the precise determination of their velocities is challenging. In this paper, we focus on the most energetic contribution and we applied a singular-value decomposition-based extraction method not yet employed in the domain of bone assessment with the aim of determining the velocity of this contribution. Signals acquired in vitro on human radii, together with academic models, were used to reveal the relationship between the velocity of the most energetic component and bone properties. The velocity of the most energetic component is highly correlated to cortical layer thickness in the in vitro database (R(2)= 0.6, P < 10(-5) compared with R(2)= 0.20, P < 10-(2) for the first arriving signal), consistent with a flexural type of wave on regular tubes or plates. Conclusions are in agreement with published papers based on other axial transmission and signal processing approaches.


Assuntos
Algoritmos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Rádio (Anatomia)/diagnóstico por imagem , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Ultrassonografia
17.
Artigo em Inglês | MEDLINE | ID: mdl-18599420

RESUMO

A singular value decomposition-based extraction algorithm is designed in order to recover the group velocity of an energetic contribution measured with an axial transmission device developed previously for cortical bone assessment. Its performance is evaluated on synthetic data mimicking in vivo signals, and it is compared with classical methods.


Assuntos
Osso e Ossos/diagnóstico por imagem , Densitometria/métodos , Interpretação de Imagem Assistida por Computador/métodos , Modelos Biológicos , Ultrassonografia/métodos , Algoritmos , Simulação por Computador , Humanos , Espalhamento de Radiação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA