Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
J Magn Reson Imaging ; 41(4): 899-902, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25051959

RESUMO

This article is intended to provide guidelines for the minimum level of safety and operational knowledge that an MR system operator should exhibit in order to safely perform an MR procedure in a human subject in a research setting. This article represents the position of the International Society for Magnetic Resonance in Medicine (ISMRM) regarding this important topic and was developed by members of this society's MR Safety Committee.


Assuntos
Pessoal de Saúde/normas , Experimentação Humana/normas , Imageamento por Ressonância Magnética/efeitos adversos , Imageamento por Ressonância Magnética/normas , Segurança do Paciente/normas , Guias de Prática Clínica como Assunto , Pesquisa Biomédica/normas , Pessoal de Saúde/educação , Humanos , Internacionalidade , Gestão da Segurança/normas
2.
J Neuroimaging ; 29(4): 440-446, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-31056818

RESUMO

BACKGROUND AND PURPOSE: The brain's stiffness measurements from magnetic resonance elastography (MRE) strongly depend on actuation frequencies, which makes cross-study comparisons challenging. We performed a preliminary study to acquire optimal sets of actuation frequencies to accurately obtain rheological parameters for the whole brain (WB), white matter (WM), and gray matter (GM). METHODS: Six healthy volunteers aged between 26 and 72 years old went through MRE with a modified single-shot spin-echo echo planar imaging pulse sequence embedded with motion encoding gradients on a 3T scanner. Frequency-independent brain material properties and best-fit material model were determined from the frequency-dependent brain tissue response data (20 -80 Hz), by comparing four different linear viscoelastic material models (Maxwell, Kelvin-Voigt, Springpot, and Zener). During the material fitting, spatial averaging of complex shear moduli (G*) obtained under single actuation frequency was performed, and then rheological parameters were acquired. Since clinical scan time is limited, a combination of three actuation frequencies that would provide the most accurate approximation and lowest fitting error was determined for WB, WM, and GM by optimizing for the lowest Bayesian information criterion (BIC). RESULTS: BIC scores for the Zener and Springpot models showed these models approximate the multifrequency response of the tissue best. The best-fit frequency combinations for the reference Zener and Springpot models were identified to be 30-60-70 and 30-40-80 Hz, respectively, for the WB. CONCLUSIONS: Optimal sets of actuation frequencies to accurately obtain rheological parameters for WB, WM, and GM were determined from shear moduli measurements obtained via 3-dimensional direct inversion. We believe that our study is a first-step in developing a region-specific multifrequency MRE protocol for the human brain.


Assuntos
Encéfalo/diagnóstico por imagem , Técnicas de Imagem por Elasticidade/métodos , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Imagem Ecoplanar , Feminino , Substância Cinzenta/diagnóstico por imagem , Voluntários Saudáveis , Humanos , Masculino , Pessoa de Meia-Idade , Substância Branca/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA