Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Epilepsia ; 65(3): 817-829, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38148517

RESUMO

OBJECTIVE: Clinicians use intracranial electroencephalography (iEEG) in conjunction with noninvasive brain imaging to identify epileptic networks and target therapy for drug-resistant epilepsy cases. Our goal was to promote ongoing and future collaboration by automating the process of "electrode reconstruction," which involves the labeling, registration, and assignment of iEEG electrode coordinates on neuroimaging. We developed a standalone, modular pipeline that performs electrode reconstruction. We demonstrate our tool's compatibility with clinical and research workflows and its scalability on cloud platforms. METHODS: We created iEEG-recon, a scalable electrode reconstruction pipeline for semiautomatic iEEG annotation, rapid image registration, and electrode assignment on brain magnetic resonance imaging (MRI). Its modular architecture includes a clinical module for electrode labeling and localization, and a research module for automated data processing and electrode contact assignment. To ensure accessibility for users with limited programming and imaging expertise, we packaged iEEG-recon in a containerized format that allows integration into clinical workflows. We propose a cloud-based implementation of iEEG-recon and test our pipeline on data from 132 patients at two epilepsy centers using retrospective and prospective cohorts. RESULTS: We used iEEG-recon to accurately reconstruct electrodes in both electrocorticography and stereoelectroencephalography cases with a 30-min running time per case (including semiautomatic electrode labeling and reconstruction). iEEG-recon generates quality assurance reports and visualizations to support epilepsy surgery discussions. Reconstruction outputs from the clinical module were radiologically validated through pre- and postimplant T1-MRI visual inspections. We also found that our use of ANTsPyNet deep learning-based brain segmentation for electrode classification was consistent with the widely used FreeSurfer segmentations. SIGNIFICANCE: iEEG-recon is a robust pipeline for automating reconstruction of iEEG electrodes and implantable devices on brain MRI, promoting fast data analysis and integration into clinical workflows. iEEG-recon's accuracy, speed, and compatibility with cloud platforms make it a useful resource for epilepsy centers worldwide.


Assuntos
Eletrocorticografia , Epilepsia , Humanos , Eletrocorticografia/métodos , Estudos Retrospectivos , Estudos Prospectivos , Epilepsia/diagnóstico por imagem , Epilepsia/cirurgia , Imageamento por Ressonância Magnética/métodos , Eletrodos , Eletroencefalografia/métodos , Eletrodos Implantados
2.
Proc Natl Acad Sci U S A ; 118(5)2021 02 02.
Artigo em Inglês | MEDLINE | ID: mdl-33495341

RESUMO

Over one third of the estimated 3 million people with epilepsy in the United States are medication resistant. Responsive neurostimulation from chronically implanted electrodes provides a promising treatment alternative to resective surgery. However, determining optimal personalized stimulation parameters, including when and where to intervene to guarantee a positive patient outcome, is a major open challenge. Network neuroscience and control theory offer useful tools that may guide improvements in parameter selection for control of anomalous neural activity. Here we use a method to characterize dynamic controllability across consecutive effective connectivity (EC) networks based on regularized partial correlations between implanted electrodes during the onset, propagation, and termination regimes of 34 seizures. We estimate regularized partial correlation adjacency matrices from 1-s time windows of intracranial electrocorticography recordings using the Graphical Least Absolute Shrinkage and Selection Operator (GLASSO). Average and modal controllability metrics calculated from each resulting EC network track the time-varying controllability of the brain on an evolving landscape of conditionally dependent network interactions. We show that average controllability increases throughout a seizure and is negatively correlated with modal controllability throughout. Our results support the hypothesis that the energy required to drive the brain to a seizure-free state from an ictal state is smallest during seizure onset, yet we find that applying control energy at electrodes in the seizure onset zone may not always be energetically favorable. Our work suggests that a low-complexity model of time-evolving controllability may offer insights for developing and improving control strategies targeting seizure suppression.


Assuntos
Progressão da Doença , Rede Nervosa/patologia , Convulsões/patologia , Epilepsia/patologia , Humanos , Fatores de Tempo
3.
Epilepsia ; 63(3): 652-662, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34997577

RESUMO

OBJECTIVE: Despite the overall success of responsive neurostimulation (RNS) therapy for drug-resistant focal epilepsy, clinical outcomes in individuals vary significantly and are hard to predict. Biomarkers that indicate the clinical efficacy of RNS-ideally before device implantation-are critically needed, but challenges include the intrinsic heterogeneity of the RNS patient population and variability in clinical management across epilepsy centers. The aim of this study is to use a multicenter dataset to evaluate a candidate biomarker from intracranial electroencephalographic (iEEG) recordings that predicts clinical outcome with subsequent RNS therapy. METHODS: We assembled a federated dataset of iEEG recordings, collected prior to RNS implantation, from a retrospective cohort of 30 patients across three major epilepsy centers. Using ictal iEEG recordings, each center independently calculated network synchronizability, a candidate biomarker indicating the susceptibility of epileptic brain networks to RNS therapy. RESULTS: Ictal measures of synchronizability in the high-γ band (95-105 Hz) significantly distinguish between good and poor RNS responders after at least 3 years of therapy under the current RNS therapy guidelines (area under the curve = .83). Additionally, ictal high-γ synchronizability is inversely associated with the degree of therapeutic response. SIGNIFICANCE: This study provides a proof-of-concept roadmap for collaborative biomarker evaluation in federated data, where practical considerations impede full data sharing across centers. Our results suggest that network synchronizability can help predict therapeutic response to RNS therapy. With further validation, this biomarker could facilitate patient selection and help avert a costly, invasive intervention in patients who are unlikely to benefit.


Assuntos
Epilepsia Resistente a Medicamentos , Epilepsia , Biomarcadores , Epilepsia Resistente a Medicamentos/terapia , Eletrocorticografia , Epilepsia/diagnóstico , Epilepsia/terapia , Humanos , Estudos Retrospectivos
4.
Sensors (Basel) ; 21(15)2021 Jul 31.
Artigo em Inglês | MEDLINE | ID: mdl-34372446

RESUMO

A low and stable impedance at the skin-electrode interface is key to high-fidelity acquisition of biosignals, both acutely and in the long term. However, recording quality is highly variable due to the complex nature of human skin. Here, we present an experimental and modeling framework to investigate the interfacial impedance behavior, and describe how skin interventions affect its stability over time. To illustrate this approach, we report experimental measurements on the skin-electrode impedance using pre-gelled, clinical-grade electrodes in healthy human subjects recorded over 24 h following four skin treatments: (i) mechanical abrasion, (ii) chemical exfoliation, (iii) microporation, and (iv) no treatment. In the immediate post-treatment period, mechanical abrasion yields the lowest initial impedance, whereas the other treatments provide modest improvement compared to untreated skin. After 24 h, however, the impedance becomes more uniform across all groups (<20 kΩ at 10 Hz). The impedance data are fitted with an equivalent circuit model of the complete skin-electrode interface, clearly identifying skin-level versus electrode-level contributions to the overall impedance. Using this model, we systematically investigate how time and treatment affect the impedance response, and show that removal of the superficial epidermal layers is essential to achieving a low, long-term stable interface impedance.


Assuntos
Pele , Impedância Elétrica , Eletrodos , Humanos
5.
medRxiv ; 2023 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-37398160

RESUMO

Background: Collaboration between epilepsy centers is essential to integrate multimodal data for epilepsy research. Scalable tools for rapid and reproducible data analysis facilitate multicenter data integration and harmonization. Clinicians use intracranial EEG (iEEG) in conjunction with non-invasive brain imaging to identify epileptic networks and target therapy for drug-resistant epilepsy cases. Our goal was to promote ongoing and future collaboration by automating the process of "electrode reconstruction," which involves the labeling, registration, and assignment of iEEG electrode coordinates on neuroimaging. These tasks are still performed manually in many epilepsy centers. We developed a standalone, modular pipeline that performs electrode reconstruction. We demonstrate our tool's compatibility with clinical and research workflows and its scalability on cloud platforms. Methods: We created iEEG-recon, a scalable electrode reconstruction pipeline for semi-automatic iEEG annotation, rapid image registration, and electrode assignment on brain MRIs. Its modular architecture includes three modules: a clinical module for electrode labeling and localization, and a research module for automated data processing and electrode contact assignment. To ensure accessibility for users with limited programming and imaging expertise, we packaged iEEG-recon in a containerized format that allows integration into clinical workflows. We propose a cloud-based implementation of iEEG-recon, and test our pipeline on data from 132 patients at two epilepsy centers using retrospective and prospective cohorts. Results: We used iEEG-recon to accurately reconstruct electrodes in both electrocorticography (ECoG) and stereoelectroencephalography (SEEG) cases with a 10 minute running time per case, and ~20 min for semi-automatic electrode labeling. iEEG-recon generates quality assurance reports and visualizations to support epilepsy surgery discussions. Reconstruction outputs from the clinical module were radiologically validated through pre- and post-implant T1-MRI visual inspections. Our use of ANTsPyNet deep learning approach for brain segmentation and electrode classification was consistent with the widely used Freesurfer segmentation. Discussion: iEEG-recon is a valuable tool for automating reconstruction of iEEG electrodes and implantable devices on brain MRI, promoting efficient data analysis, and integration into clinical workflows. The tool's accuracy, speed, and compatibility with cloud platforms make it a useful resource for epilepsy centers worldwide. Comprehensive documentation is available at https://ieeg-recon.readthedocs.io/en/latest/.

6.
J Neural Eng ; 20(4)2023 08 10.
Artigo em Inglês | MEDLINE | ID: mdl-37531949

RESUMO

Objective.Epilepsy is a neurological disorder characterized by recurrent seizures which vary widely in severity, from clinically silent to prolonged convulsions. Measuring severity is crucial for guiding therapy, particularly when complete control is not possible. Seizure diaries, the current standard for guiding therapy, are insensitive to the duration of events or the propagation of seizure activity across the brain. We present a quantitative seizure severity score that incorporates electroencephalography (EEG) and clinical data and demonstrate how it can guide epilepsy therapies.Approach.We collected intracranial EEG and clinical semiology data from 54 epilepsy patients who had 256 seizures during invasive, in-hospital presurgical evaluation. We applied an absolute slope algorithm to EEG recordings to identify seizing channels. From this data, we developed a seizure severity score that combines seizure duration, spread, and semiology using non-negative matrix factorization. For validation, we assessed its correlation with independent measures of epilepsy burden: seizure types, epilepsy duration, a pharmacokinetic model of medication load, and response to epilepsy surgery. We investigated the association between the seizure severity score and preictal network features.Main results.The seizure severity score augmented clinical classification by objectively delineating seizure duration and spread from recordings in available electrodes. Lower preictal medication loads were associated with higher seizure severity scores (p= 0.018, 97.5% confidence interval = [-1.242, -0.116]) and lower pre-surgical severity was associated with better surgical outcome (p= 0.042). In 85% of patients with multiple seizure types, greater preictal change from baseline was associated with higher severity.Significance.We present a quantitative measure of seizure severity that includes EEG and clinical features, validated on gold standard in-patient recordings. We provide a framework for extending our tool's utility to ambulatory EEG devices, for linking it to seizure semiology measured by wearable sensors, and as a tool to advance data-driven epilepsy care.


Assuntos
Epilepsia , Convulsões , Humanos , Convulsões/diagnóstico , Convulsões/terapia , Eletroencefalografia/métodos , Encéfalo/cirurgia , Eletrocorticografia
7.
medRxiv ; 2023 Jul 07.
Artigo em Inglês | MEDLINE | ID: mdl-37461688

RESUMO

Background: Longitudinal EEG recorded by implanted devices is critical for understanding and managing epilepsy. Recent research reports patient-specific, multi-day cycles in device-detected epileptiform events that coincide with increased likelihood of clinical seizures. Understanding these cycles could elucidate mechanisms generating seizures and advance drug and neurostimulation therapies. Objective/Hypothesis: We hypothesize that seizure-correlated cycles are present in background neural activity, independent of interictal epileptiform spikes, and that neurostimulation may disrupt these cycles. Methods: We analyzed regularly-recorded seizure-free data epochs from 20 patients implanted with a responsive neurostimulation (RNS) device for at least 1.5 years, to explore the relationship between cycles in device-detected interictal epileptiform activity (dIEA), clinician-validated interictal spikes, background EEG features, and neurostimulation. Results: Background EEG features tracked the cycle phase of dIEA in all patients (AUC: 0.63 [0.56 - 0.67]) with a greater effect size compared to clinically annotated spike rate alone (AUC: 0.55 [0.53-0.61], p < 0.01). After accounting for circadian variation and spike rate, we observed significant population trends in elevated theta and beta band power and theta and alpha connectivity features at the cycle peaks (sign test, p < 0.05). In the period directly after stimulation we observe a decreased association between cycle phase and EEG features compared to background recordings (AUC: 0.58 [0.55-0.64]). Conclusions: Our findings suggest that seizure-correlated dIEA cycles are not solely due to epileptiform discharges but are associated with background measures of brain state; and that neurostimulation may disrupt these cycles. These results may help elucidate mechanisms underlying seizure generation, provide new biomarkers for seizure risk, and facilitate monitoring, treating, and managing epilepsy with implantable devices.

8.
Brain Stimul ; 16(6): 1709-1718, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37979654

RESUMO

BACKGROUND: Longitudinal EEG recorded by implanted devices is critical for understanding and managing epilepsy. Recent research reports patient-specific, multi-day cycles in device-detected epileptiform events that coincide with increased likelihood of clinical seizures. Understanding these cycles could elucidate mechanisms generating seizures and advance drug and neurostimulation therapies. OBJECTIVE/HYPOTHESIS: We hypothesize that seizure-correlated cycles are present in background neural activity, independent of interictal epileptiform spikes, and that neurostimulation may temporarily interrupt these cycles. METHODS: We analyzed regularly-recorded seizure-free data epochs from 20 patients implanted with a responsive neurostimulation (RNS) device for at least 1.5 years, to explore the relationship between cycles in device-detected interictal epileptiform activity (dIEA), clinician-validated interictal spikes, background EEG features, and neurostimulation. RESULTS: Background EEG features tracked the cycle phase of dIEA in all patients (AUC: 0.63 [0.56-0.67]) with a greater effect size compared to clinically annotated spike rate alone (AUC: 0.55 [0.53-0.61], p < 0.01). After accounting for circadian variation and spike rate, we observed significant population trends in elevated theta and beta band power and theta and alpha connectivity features at the cycle peaks (sign test, p < 0.05). In the period directly after stimulation we observe a decreased association between cycle phase and EEG features compared to background recordings (AUC: 0.58 [0.55-0.64]). CONCLUSIONS: Our findings suggest that seizure-correlated dIEA cycles are not solely due to epileptiform discharges but are associated with background measures of brain state; and that neurostimulation may temporarily interrupt these cycles. These results may help elucidate mechanisms underlying seizure generation, provide new biomarkers for seizure risk, and facilitate monitoring, treating, and managing epilepsy with implantable devices.


Assuntos
Eletroencefalografia , Epilepsia , Humanos , Eletroencefalografia/métodos , Epilepsia/terapia , Convulsões/terapia , Encéfalo
9.
Front Digit Health ; 4: 874208, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35445206

RESUMO

The Unified Huntington's Disease Rating Scale (UHDRS) is the primary clinical assessment tool for rating motor function in patients with Huntington's disease (HD). However, the UHDRS and similar rating scales (e.g., UPDRS) are both subjective and limited to in-office assessments that must be administered by a trained and experienced rater. An objective, automated method of quantifying disease severity would facilitate superior patient care and could be used to better track severity over time. We conducted the present study to evaluate the feasibility of using wearable sensors, coupled with machine learning algorithms, to rate motor function in patients with HD. Fourteen participants with symptomatic HD and 14 healthy controls participated in the study. Each participant wore five adhesive biometric sensors applied to the trunk and each limb while completing brief walking, sitting, and standing tasks during a single office visit. A two-stage machine learning method was employed to classify participants by HD status and to predict UHDRS motor subscores. Linear discriminant analysis correctly classified all participants' HD status except for one control subject with abnormal gait (96.4% accuracy, 92.9% sensitivity, and 100% specificity in leave-one-out cross-validation). Two regression models accurately predicted individual UHDRS subscores for gait, and dystonia within a 10% margin of error. Our regression models also predicted a composite UHDRS score-a sum of left and right arm rigidity, total chorea, total dystonia, bradykinesia, gait, and tandem gait subscores-with an average error below 15%. Machine learning classifiers trained on brief in-office datasets discriminated between controls and participants with HD, and could accurately predict selected motor UHDRS subscores. Our results could enable the future use of biosensors for objective HD assessment in the clinic or remotely and could inform future studies for the use of this technology as a potential endpoint in clinical trials.

10.
J Am Med Inform Assoc ; 29(5): 873-881, 2022 04 13.
Artigo em Inglês | MEDLINE | ID: mdl-35190834

RESUMO

OBJECTIVE: Seizure frequency and seizure freedom are among the most important outcome measures for patients with epilepsy. In this study, we aimed to automatically extract this clinical information from unstructured text in clinical notes. If successful, this could improve clinical decision-making in epilepsy patients and allow for rapid, large-scale retrospective research. MATERIALS AND METHODS: We developed a finetuning pipeline for pretrained neural models to classify patients as being seizure-free and to extract text containing their seizure frequency and date of last seizure from clinical notes. We annotated 1000 notes for use as training and testing data and determined how well 3 pretrained neural models, BERT, RoBERTa, and Bio_ClinicalBERT, could identify and extract the desired information after finetuning. RESULTS: The finetuned models (BERTFT, Bio_ClinicalBERTFT, and RoBERTaFT) achieved near-human performance when classifying patients as seizure free, with BERTFT and Bio_ClinicalBERTFT achieving accuracy scores over 80%. All 3 models also achieved human performance when extracting seizure frequency and date of last seizure, with overall F1 scores over 0.80. The best combination of models was Bio_ClinicalBERTFT for classification, and RoBERTaFT for text extraction. Most of the gains in performance due to finetuning required roughly 70 annotated notes. DISCUSSION AND CONCLUSION: Our novel machine reading approach to extracting important clinical outcomes performed at or near human performance on several tasks. This approach opens new possibilities to support clinical practice and conduct large-scale retrospective clinical research. Future studies can use our finetuning pipeline with minimal training annotations to answer new clinical questions.


Assuntos
Epilepsia , Processamento de Linguagem Natural , Registros Eletrônicos de Saúde , Humanos , Estudos Retrospectivos , Convulsões
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA