1.
Am J Perinatol ; 39(9): 1001-1007, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-33242911

RESUMO

OBJECTIVE: It is not known how much surfactant must be nebulized to reach a lung dose of phospholipids equivalent to that obtained by the instillation of 200 mg/kg of surfactant. We aimed to assess the feasibility of nebulizing a high-dose of poractant alfa with the eFlow-Neos investigational vibrating-membrane nebulizer in newborn piglets on nasal continuous positive airway pressure (nCPAP) and to determine whether this intervention would yield therapeutic lung doses of phospholipids. STUDY DESIGN: Twelve 1-day-old piglets on nCPAP received 600 mg/kg of poractant alfa admixed with technetium-99m via nebulization. Six piglets receiving 200 mg/kg of instilled synthetic surfactant served as controls. Lung deposition (percentage of the nominal dose) was determined by gamma scintigraphy, and the phospholipids' lung dose was calculated. RESULTS: The lung dose of phospholipids (mean ± standard deviation [SD]) was 138 ± 96 mg/kg with nebulization, and 172 ± 24 mg/kg with instillation (p = 0.42). Nebulization took 58 ± 12 minutes. The arterial partial pressure of carbon dioxide increased from 6.7 ± 1.1 to 7.2 ± 1.1 kPa during nebulization (p = 0.04). Cerebral oximetry remained stable, and there was no hemodynamic instability. CONCLUSION: Nebulization was well tolerated, and the mean lung dose of phospholipids was above 100 mg/kg, that is, not different from the instillation group. These experimental findings suggest that it may be feasible to reach therapeutic lung doses of phospholipids by surfactant nebulization during nCPAP. KEY POINTS: · It is not known if effective lung doses of surfactant can be delivered by nebulization.. · Nebulization of high-dose surfactant in newborn piglets on nCPAP was well tolerated.. · A high-dose of nebulized poractant alfa yielded therapeutic lung doses of phospholipids..


Assuntos
Produtos Biológicos , Surfactantes Pulmonares , Síndrome do Desconforto Respiratório do Recém-Nascido , Animais , Animais Recém-Nascidos , Circulação Cerebrovascular , Pressão Positiva Contínua nas Vias Aéreas , Humanos , Recém-Nascido , Pulmão , Oximetria , Fosfolipídeos , Síndrome do Desconforto Respiratório do Recém-Nascido/terapia , Tensoativos , Suínos
2.
Neonatology ; 117(4): 467-473, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32604091

RESUMO

INTRODUCTION: The ideal body position during surfactant nebulization is not known. OBJECTIVE: The aim of this study was to determine whether body positioning during surfactant nebulization influences surfactant distribution and deposition in the lungs. METHODS: Twenty-four 12- to 36-h-old full-termpiglets (1.3-2.2 kg) on nasal continuous positive airway pressure (nCPAP) were randomized into four groups: lateral decubitus with right or left side up, prone or supine positions (n = 6 each). All animals received 200 mg kg-1 of poractant alfa mixed with 200 MBq of 99mtechnetium-nanocolloid via a customized eFlow-Neos investigational vibrating-membrane nebulizer. Surfactant deposition (percentage of the administered dose) was measured by gamma scintigraphy. RESULTS: Comparing all groups, the mean total lung surfactant deposition was significantly higher in the prone position (32.4 ± 7.7%, p = 0.03). The deposition in this group was higher in the right lung (21.0 ± 8.6 vs. 11.3 ± 5.7%, p = 0.04). When nebulization was performed in the lateral decubitus, most of the surfactant was found in the dependent lung, regardless of which side the piglet lay on (right side up 15.3 ± 1.0 vs. 3.4 ± 1.0%, p = 0.06, and left side up 11.2 ± 9.8 vs. 1.8 ± 0.7%, p = 0.04). CONCLUSIONS: In spontaneously breathing animals on nCPAP, the prone position yielded the highest lung dose. Higher deposition rates in the dependent lung while on lateral decubitus indicates that deposition was also influenced by gravity.


Assuntos
Pressão Positiva Contínua nas Vias Aéreas , Surfactantes Pulmonares , Animais , Animais Recém-Nascidos , Pulmão/diagnóstico por imagem , Tensoativos , Suínos
3.
Pediatr Pulmonol ; 55(2): 514-520, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31833668

RESUMO

BACKGROUND: Nasal continuous positive airway pressure support (nCPAP) is the standard of care for prematurely born infants at risk of neonatal respiratory distress syndrome (nRDS). However, nasal intermittent positive pressure ventilation (NIPPV) may be an alternative to nCPAP in babies requiring surfactant, and in conjunction with surfactant nebulization, it could theoretically reduce the need for invasive mechanical ventilation. We compared lung deposition of nebulized poractant in newborn piglets supported by nCPAP or NIPPV. METHODS: Twenty-five sedated newborn piglets (1.2-2.2 kg) received either nCPAP (3 cmH2 O, n = 12) or NIPPV (3 cmH2 O positive end expiratory pressure+3 cmH2 O inspiratory pressure, n = 13) via custom-made nasal prongs (FiO2 0.4, Servo-i ventilator). Piglets received 200 mg kg-1 of technetium-99m-surfactant mixture continuously nebulized with a customized eFlow-Neos investigational vibrating-membrane nebulizer system. Blood gases were taken immediately before, during, and after nebulization. The deposition was estimated by gamma scintigraphy. RESULTS: Mean surfactant deposition in the lungs was 15.9 ± 11.9% [8.3, 23.5] (mean ± SD [95% CI]) in the nCPAP group and 21.6 ± 10% [15.6, 27.6] in the NIPPV group (P = .20). Respiratory rates were similar in both groups. Minute volume was 489 ± 203 [360, 617] in the nCPAP group and 780 ± 239 [636, 924] mL kg-1 min-1 in the NIPPV group (P = .009). Blood gases were comparable in both groups. CONCLUSION: Irrespective of the noninvasive ventilatory support mode used, relatively high lung deposition rates of surfactant were achieved with nebulization. The amounts of deposited surfactant might suffice to elicit a pulmonary function improvement in the context of nRDS.


Assuntos
Pressão Positiva Contínua nas Vias Aéreas , Ventilação com Pressão Positiva Intermitente , Surfactantes Pulmonares , Animais , Animais Recém-Nascidos , Produtos Biológicos , Recém-Nascido Prematuro , Doenças do Prematuro , Pulmão , Nebulizadores e Vaporizadores , Nariz , Fosfolipídeos , Respiração Artificial , Síndrome do Desconforto Respiratório do Recém-Nascido , Tensoativos , Suínos
4.
Pharmaceutics ; 12(3)2020 Mar 12.
Artigo em Inglês | MEDLINE | ID: mdl-32178276

RESUMO

Non-invasive delivery of nebulized surfactant has been a long-pursued goal in neonatology. Our aim was to evaluate the performance of an investigational vibrating-membrane nebulizer in a realistic non-invasive neonatal ventilation circuit with different configurations. Surfactant (aerosols were generated with a nebulizer in a set-up composed of a continuous positive airway pressure (CPAP) generator with a humidifier, a cast of the upper airway of a preterm infant (PrINT), and a breath simulator with a neonatal breathing pattern. The lung dose (LD), defined as the amount of surfactant collected in a filter placed at the distal end of the PrINT cast, was determined after placing the nebulizer at different locations of the circuit and using either infant nasal mask or nasal prongs as CPAP interfaces. The LD after delivering a range of nominal surfactant doses (100-600 mg/kg) was also investigated. Surfactant aerosol particle size distribution was determined by laser diffraction. Irrespective of the CPAP interface used, about 14% of the nominal dose (200 mg/kg) reached the LD filter. However, placing the nebulizer between the Y-piece and the CPAP interface significantly increased the LD compared with placing it 7 cm before the Y-piece, in the inspiratory limb. (14% ± 2.8 vs. 2.3% ± 0.8, nominal dose of 200 mg/kg). The customized eFlow Neos showed a constant aerosol generation rate and a mass median diameter of 2.7 µm after delivering high surfactant doses (600 mg/kg). The customized eFlow Neos nebulizer showed a constant performance even after nebulizing high doses of undiluted surfactant. Placing the nebulizer between the Y-piece and the CPAP interface achieves the highest LD under non-invasive ventilation conditions.

5.
Pharmaceutics ; 12(4)2020 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-32252349

RESUMO

The delivery of nebulized medications to preterm infants during Non-Invasive Ventilation (NIV) remains an unmet clinical need. In this regard, the effective delivery of nebulized surfactant has been particularly investigated in preclinical and clinical studies. In this work, we investigated the feasibility of delivering nebulized surfactant through various commercially available nasal prong types. We first performed a compendial characterization of surfactant aerosols generated by the eFlow Neos nebulizer, customized to be used in neonates, determining the amount of surfactant delivered by the device as well as the aerodynamic characteristics of surfactant aerosols. Additionally, we extended the compendial characterization by testing the effect of different nasal prong types on the estimated lung dose using a realistic Continuous Positive Airway Pressure (CPAP) circuit that included a cast of the upper airways of a preterm neonate. The compendial characterization of surfactant aerosols delivered through different nasal prongs achieved relatively high delivered surfactant doses (in the range 63-74% of the nominal dose), with aerodynamic characteristics displaying mass median aerodynamic diameters ranging between 2.52 and 2.81 µm. Nevertheless, when using a representative in vitro setup mimicking NIV in a clinical setting, significant differences were observed in terms of the estimated lung dose accounting for up to two-fold differences (from 10% to 20% estimated lung deposition of the nominal dose) depending on the chosen nasal prong type. Considering that surfactant lung deposition rates are correlated with therapeutic efficacy, this study points out the relevance of choosing the appropriate NIV interface to maximize the lung dose of nebulized medications.

6.
J Biomech Eng ; 127(1): 25-31, 2005 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-15868785

RESUMO

BACKGROUND: The development of endoluminal stents from polymeric materials requires an understanding of the basic mechanical properties of the polymer and the effects of manufacturing and sterilization on those properties. METHODS: Pure poly(L-lactide) (PLLA) and PLLA containing varying amounts of triethylcitrate (TEC) as a plasticizer (5-10-15%) were studied. The specimens were solution-cast and CO2 laser-cut. Specimen dimensions were adapted to the strut size of polymeric vascular stents. The properties of the PLLA micro-specimens were assessed before and after sterilization (EtO cold gas, H2O2-plasma, beta- and gamma-irradiation). Tensile tests, and creep and recovery tests were carried out at 37 degrees C. Additionally the thermal and thermo-mechanical characteristics were investigated using dynamic-mechanical analysis (DMA) and differential scanning calorimetry (DSC). RESULTS: The results showed the dramatic influence of the plasticizer content and sterilization procedure on the mechanical properties of the material. Laser cutting had a lesser effect. Hence the effects of processing and sterilization must not be overlooked in the material selection and design phases of the development process leading to clinical use. Altogether, the results of these studies provide a clearer understanding of the complex interaction between the laser machining process and terminal sterilization on the primary mechanical properties of PLLA and PLLA plasticized with TEC.


Assuntos
Materiais Biocompatíveis/química , Prótese Vascular , Poliésteres/química , Stents , Esterilização/métodos , Materiais Biocompatíveis/análise , Materiais Biocompatíveis/efeitos da radiação , Citratos/análise , Citratos/química , Elasticidade , Análise de Falha de Equipamento/métodos , Lasers , Teste de Materiais , Peso Molecular , Plastificantes/análise , Plastificantes/química , Poliésteres/análise , Poliésteres/efeitos da radiação , Desenho de Prótese/métodos , Temperatura , Resistência à Tração , Temperatura de Transição , Viscosidade