Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-38568735

RESUMO

RATIONALE: A hemodynamically significant patent ductus arteriosus (hsPDA) in premature infants has been associated with bronchopulmonary dysplasia (BPD) and pulmonary hypertension (PH). However, these associations remain incompletely understood. OBJECTIVES: The aim was to assess the association between hsPDA duration with clinical outcomes, PH, and phenotypic differences on lung MRI. METHODS: This retrospective cohort study identified all infants with BPD <32 weeks gestation who also underwent a research lung MRI <48 weeks postmenstrual age (PMA) from 2014-2022. Clinical echocardiograms were reviewed for hsPDA, and categorized into no hsPDA, hsPDA 1-60 days, and hsPDA >60 days. Outcome variables included BPD severity, PH at 36 weeks PMA, PH after 36 weeks PMA in the absence of shunt (PH-PVD), tracheostomy or death, and lung phenotype by MRI via modified Ochiai score, indexed total lung volume (TLVI), and whole lung hyperdensity (WLH). Logistic regression and ANOVA analysis were used. MEASUREMENTS AND MAIN RESULTS: In total, 133 infants born at 26.2 ± 1.9 weeks and 776 ± 276g were reviewed (47 no hsPDA, 44 hsPDA 1-60 days, 42 hsPDA >60 days). hsPDA duration >60 days was associated with BPD severity (p<0.01), PH at 36 weeks PMA (aOR 9.7 [95% CI: 3.3-28.4]), PH-PVD (aOR 6.5 [95% CI: 2.3-18.3]), and tracheostomy or death (aOR 3.0 [95% CI: 1.0-8.8]). Duration of hsPDA > 60 days was associated with higher Ochiai score (p=0.03) and TLVI (p=0.01), but not WLH (p=0.91). CONCLUSIONS: In infants with moderate or severe BPD, prolonged exposure to hsPDA is associated with BPD severity, PH-PVD, and increased parenchymal lung disease by MRI.

2.
Pediatr Cardiol ; 43(6): 1205-1213, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35124709

RESUMO

We evaluate the validity of cardiac index (CI) measurements utilizing the Ultrasonic Cardiac Output Monitor (USCOM), a non-invasive Doppler ultrasound device, by comparing measurements to cardiac catheterization-derived CI measurements in patients with single-ventricle physiology. USCOM measurements were repeated three times for each patient at the beginning of a cardiac catheterization procedure for twenty-six patients undergoing elective pre-Glenn or pre-Fontan catheterization. CI was measured by USCOM and was calculated from cardiac catheterization data using Fick's method. Bland-Altman analysis for CI showed bias of 0.95 L/min/m2 with the 95% limits of agreement of - 1.85 and 3.75. Pearson's correlation coefficient was 0.89 (p < 0.001) indicating a strong positive relationship between USCOM and cardiac catheterization CI measurements. When excluding two patients with significant dilation of the neo-aortic valve (z-score > + 5), the bias improved to 0.66 L/min/m2 with the 95% limits of agreement of - 1.38 and 2.70. Percent error of limits of agreement was 34%. There was excellent intra-operator reproducibility of USCOM CI measurements with an intra-class coefficient of 0.96. We demonstrate the use of USCOM to measure CI in patients with single-ventricle physiology for the first time, showing acceptable agreement of the CI measurements between USCOM and cardiac catheterization with a high intra-operator reproducibility.


Assuntos
Anormalidades Cardiovasculares , Ultrassom , Débito Cardíaco , Humanos , Monitorização Fisiológica/métodos , Reprodutibilidade dos Testes , Ultrassonografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA