Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 45
Filtrar
1.
Catheter Cardiovasc Interv ; 103(1): 137-146, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-37890011

RESUMO

BACKGROUND: The development of the PASCAL transcatheter valve repair system for treating mitral regurgitation (MR) greatly extends therapeutic options. AIMS: To assess the safety, efficacy, and time efficiency of the PASCAL system in transcatheter edge-to-edge repair (TEER) under conscious sedation (CS). METHODS: This is a retrospective, two-center, German registry study consisting of 211 patients who underwent TEER using the PASCAL system under CS. The endpoints were to assess (1) technical, device, and procedural success as per Mitral Valve Academic Research Consortium (MVARC), (2) conversion rate to general anesthesia (GA), (3) hospital length of stay (LoS), (4) New York Heart Association (NYHA) class, and (5) MR compared to baseline at 30-day. RESULTS: A total of 211 patients with a mean age of 78.4 ± 8.9 years, with 51.4% being female and 86.7% belonging to NYHA functional class III/IV and EuroSCORE II 6.3 ± 4.9%, were enrolled. Procedural success attained was 96.9%, and six patients (2.8%) required conversion from CS to GA. At 30 days follow-up, a significant improvement in MR was found in 96 patients (54.2%) patients with 0/1 grade MR and 45 patients (29.5%) were in NYHA functional class III + IV. Moreover, TEER under CS has a short hospital LoS (6.71 ± 5.29 days) and intensive care unit LoS (1.34 ± 3.49 days) with a 2.8% mortality rate. CONCLUSIONS: Performing TEER with the PASCAL system under CS resulted in appreciable (96.9%) procedural success with low mortality and is a safe and promising alternative to GA with positive clinical outcomes.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Humanos , Feminino , Idoso , Idoso de 80 Anos ou mais , Masculino , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Sedação Consciente/efeitos adversos , Estudos Retrospectivos , Resultado do Tratamento , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Cateterismo Cardíaco
2.
Cardiovasc Ultrasound ; 18(1): 32, 2020 Aug 12.
Artigo em Inglês | MEDLINE | ID: mdl-32787878

RESUMO

BACKGROUND: Right ventricular (RV) function is an important prognostic indicator. The acute effects of cardiac interventions or cardiac surgery on global and longitudinal RV function are not entirely understood. In this study, acute changes of RV function during mitral valve surgery (MVS), percutaneous mitral valve repair (PMVR) and off-pump coronary artery bypass surgery (OPCAB) were investigated employing 3D echocardiography. METHODS: Twenty patients scheduled for MVS, 23 patients scheduled for PMVR and 25 patients scheduled for OPCAB were included retrospectively if patients had received 3D transesophageal echocardiography before and immediately after MVS, PMVR or OPCAB, respectively. RV global and longitudinal function was assessed using a 3D multiparameter set consisting of global right ventricular ejection fraction (RVEF), tricuspid annular plane systolic excursion (TAPSE), longitudinal contribution to RVEF (RVEFlong) and free wall longitudinal strain (FWLS). RESULTS: Longitudinal RV function was significantly depressed immediately after MVS, as reflected by all parameters (RVEFlong: 20 ± 5% vs. 13 ± 6%, p <  0.001, TAPSE: 13.1 ± 5.1 mm vs. 11.0 ± 3.5 mm, p = 0.04 and FWLS: -20.1 ± 7.1% vs. -15.4 ± 5.1%, p <  0.001, respectively). The global RVEF was slightly impaired, but the difference did not reach significance (37 ± 13% vs. 32 ± 9%, p = 0.15). In the PMVR group, both global and longitudinal RV function parameters were unaltered, whereas the OPCAB group showed a slight reduction of RVEFlong only (18 ± 7% vs. 14 ± 5%, p <  0.01). RVEFlong yielded moderate case-to-case but good overall reproducibility. CONCLUSIONS: TAPSE, FWLS and RVEFlong reflect the depression of longitudinal compared to global RV function initially after MVS. PMVR alone had no impact, while OPCAB had a slight impact on longitudinal RV function. The prognostic implications of these phenomena remain unclear and require further investigation.


Assuntos
Ponte de Artéria Coronária sem Circulação Extracorpórea , Ecocardiografia Tridimensional , Insuficiência da Valva Mitral/cirurgia , Disfunção Ventricular Direita/diagnóstico por imagem , Disfunção Ventricular Direita/fisiopatologia , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Reprodutibilidade dos Testes , Estudos Retrospectivos , Volume Sistólico
3.
NEJM Evid ; 3(1): EVIDoa2300235, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38320511

RESUMO

BACKGROUND: Rivaroxaban and dabigatran were not superior to aspirin in trials of patients with embolic stroke of undetermined source (ESUS). It is unknown whether apixaban is superior to aspirin in patients with ESUS and known risk factors for cardioembolism. METHODS: We conducted a multicenter, randomized, open-label, blinded-outcome trial of apixaban (5 mg twice daily) compared with aspirin (100 mg once daily) initiated within 28 days after ESUS in patients with at least one predictive factor for atrial fibrillation or a patent foramen ovale. Cardiac monitoring was mandatory, and aspirin treatment was switched to apixaban in case of atrial fibrillation detection. The primary outcome was any new ischemic lesion on brain magnetic resonance imaging (MRI) during 12-month follow-up. Secondary outcomes included major and clinically relevant nonmajor bleeding. RESULTS: A total of 352 patients were randomly assigned to receive apixaban (178 patients) or aspirin (174 patients) at a median of 8 days after ESUS. At 12-month follow-up, MRI follow-up was available in 325 participants (92.3%). New ischemic lesions occurred in 23 of 169 (13.6%) participants in the apixaban group and in 25 of 156 (16.0%) participants in the aspirin group (adjusted odds ratio, 0.79; 95% confidence interval, 0.42 to 1.48; P=0.57). Major and clinically relevant nonmajor bleeding occurred in five and seven participants, respectively (1-year cumulative incidences, 2.9 and 4.2; hazard ratio, 0.68; 95% confidence interval, 0.22 to 2.16). Serious adverse event rates were 43.9 per 100 person-years in those given apixaban and 45.7 per 100 person-years in those given aspirin. The Apixaban for the Treatment of Embolic Stroke of Undetermined Source trial was terminated after a prespecified interim analysis as a result of futility. CONCLUSIONS: Apixaban treatment was not superior to cardiac monitoring-guided aspirin in preventing new ischemic lesions in an enriched ESUS population. (Funded by Bristol-Myers Squibb and Medtronic Europe; ClinicalTrials.gov number, NCT02427126.)


Assuntos
AVC Embólico , Pirazóis , Piridonas , Acidente Vascular Cerebral , Humanos , Aspirina , Método Duplo-Cego , Acidente Vascular Cerebral/prevenção & controle
4.
JACC Cardiovasc Interv ; 17(7): 890-903, 2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38599692

RESUMO

BACKGROUND: Mitral transcatheter edge-to-edge repair (M-TEER) is a guideline-recommended treatment option for patients with severe symptomatic mitral regurgitation (MR). Outcomes with the PASCAL system in a post-market setting have not been established. OBJECTIVES: The authors report 30-day and 1-year outcomes from the MiCLASP (Transcatheter Repair of Mitral Regurgitation with Edwards PASCAL Transcatheter Valve Repair System) European post-market clinical follow-up study. METHODS: Patients with symptomatic, clinically significant MR were prospectively enrolled. The primary safety endpoint was clinical events committee-adjudicated 30-day composite major adverse event rate and the primary effectiveness endpoint was echocardiographic core laboratory-assessed MR severity at discharge compared with baseline. Clinical, echocardiographic, functional, and quality-of-life outcomes were assessed at 1 year. RESULTS: A total of 544 patients were enrolled (59% functional MR, 30% degenerative MR). The 30-day composite major adverse event rate was 6.8%. MR reduction was significant from baseline to discharge and sustained at 1 year with 98% of patients achieving MR ≤2+ and 82.6% MR ≤1+ (all P < 0.001 vs baseline). One-year Kaplan-Meier estimate for survival was 87.3%, and freedom from heart failure hospitalization was 84.3%. Significant functional and quality-of-life improvements were observed at 1 year, including 71.6% in NYHA functional class I/II, 14.4-point increase in Kansas City Cardiomyopathy Questionnaire score, and 24.2-m improvement in 6-minute walk distance (all P < 0.001 vs baseline). CONCLUSIONS: One-year outcomes of this large cohort from the MiCLASP study demonstrate continued safety and effectiveness of M-TEER with the PASCAL system in a post-market setting. Results demonstrate high survival and freedom from heart failure hospitalization, significant and sustained MR reduction, and improvements in symptoms, functional capacity, and quality of life.


Assuntos
Insuficiência Cardíaca , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Humanos , Seguimentos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Qualidade de Vida , Resultado do Tratamento , Implante de Prótese de Valva Cardíaca/efeitos adversos , Cateterismo Cardíaco/efeitos adversos
5.
Case Rep Cardiol ; 2023: 5586197, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38125827

RESUMO

We present a case of a patient with a transient ischaemic attack (TIA) likely due to paradoxical embolism through a patent foramen ovale (PFO). Her medical history included 2nd-degree heart block Mobitz II, which manifested with recurrent syncopes and was treated with a dual chamber pacemaker. During the interventional PFO closure procedure, we noted entrapment of the atrial pacemaker lead between the right-sided occluder disc and the interatrial septum. We were able to successfully move the lead aside using a 24 mm sizing balloon and subsequently developed the right-sided occluder disc in the correct position. In conclusion, pacemaker-lead entrapment between a PFO occluder disc and the interatrial septum can be prevented using a sizing balloon.

6.
Int J Cardiol Heart Vasc ; 45: 101190, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36941997

RESUMO

Background: Percutaneous mitral valve repair (PMVR) has evolved to be a standard procedure in suitable patients with mitral regurgitation (MR) not accessible for open surgery. Here, we analyzed the influence of the number and positioning of the clips implanted during the procedure on MR reduction analyzing also sub-collectives of functional and degenerative MR (DMR). Results: We included 410 patients with severe MR undergoing PMVR using the MitraClip® System. MR and reduction of MR were analyzed by TEE at the beginning and at the end of the PMVR procedure. To specify the clip localization, we sub-divided segment 2 into 3 sub-segments using the segmental classification of the mitral valve. Results: We found an enhanced reduction of MR predominantly in DMR patients who received more than one clip. Implantation of only one clip led to a higher MR reduction in patients with functional MR (FMR) in comparison to patients with DMR. No significant differences concerning pressure gradients could be observed in degenerative MR patients regardless of the number of clips implanted. A deterioration of half a grade of the achieved MR reduction was observed 6 months post-PMVR independent of the number of implanted clips with a better stability in FMR patients, who got 3 clips compared to patients with only one clip. Conclusions: In patients with FMR, after 6 months the reduction of MR was more stable with an increased number of implanted clips, which suggests that this specific patient collective may benefit from a higher number of clips.

8.
Pacing Clin Electrophysiol ; 34(8): 939-48, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21501179

RESUMO

BACKGROUND: Catheter ablation of complex fractionated atrial electrograms (CFAE) for persistent atrial fibrillation (AF) is a promising treatment strategy. We tested the hypothesis that CFAE ablation is superior to linear ablation in patients with persistent or long-standing persistent AF. METHODS: In this study, 116 patients with persistent AF were randomly assigned to undergo circumferential PVI plus additional lines (linear ablation group; 59 patients) or CFAE ablation plus ostial pulmonary vein isolation (PVI) (spot ablation group; 57 patients). Primary endpoint was freedom from atrial tachyarrhythmia after a single ablation procedure (clinical and repeat 7-day Holter), 12 months after ablation without antiarrhythmic medication. RESULTS: The primary endpoint was reached in 22 of 59 (37%) patients of the linear ablation group and in 22 of 57 (39%) patients of the spot ablation group (P = 0.9). Freedom from atrial tachyarrhythmias, including reablations, was achieved in 54% of patients (linear ablation group) versus 56% of patients (spot ablation group; P = 0.8). The incidence of recurrent persistent AF was higher after linear ablation than after spot ablation (21/37 vs 11/35 patients; P = 0.03); atrial tachycardia (AT) was seen more often after spot ablation (10/35 vs 4/37 patients; P = 0.03). CONCLUSION: In patients with persistent AF, CFAE ablation plus PVI reaches the same results as circumferential PVI plus lines, in terms of freedom from symptomatic atrial tachyarrhythmias within the first year after a single ablation procedure. Arrhythmia recurrences in patients after spot ablation were caused more often by AT, whereas recurrent persistent AF was more prevalent after the linear ablation approach.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Técnicas Eletrofisiológicas Cardíacas/métodos , Idoso , Fibrilação Atrial/fisiopatologia , Feminino , Átrios do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , Resultado do Tratamento
9.
Gen Physiol Biophys ; 30(1): 11-9, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21460407

RESUMO

Atrial fibrillation (AF) is the most common sustained arrhythmia in man. Over the past years, importance of the renin-angiotensin-aldosterone system in AF pathophysiology has been recognized. Lately, the role of aldosterone in AF pathophysiology and mineralocorticoid receptor (MR) antagonism in "upstream" AF treatment is discussed with special regards concerning the effects on AF-induced structural remodeling. However, there is more and more evidence that MR antagonism also influences atrial electrophysiology and, respectively, AF-induced electrical remodeling, whereas the molecular mechanisms are almost unknown. The aim of this mini-review is to give an overview about the role of aldosterone in AF pathophysiology in principle and to summarize current available data concerning affection of cardiac ion channels by aldosterone and MR antagonism. Finally, as modulation of oxidative stress is discussed as one main therapy principle of "upstream" treatment of AF, potential mechanisms how modulation of oxidative stress by aldosterone and accordingly MR antagonism might alter atrial ion currents are delineated. Summarized, publications concerning potential mechanisms of aldosterone- and MR antagonism-modulated cardiac ion channels in various experimental settings are almost exclusively limited to the ventricular level and, partly, they are also contradictorily. Translation of these data to the atria is problematic because atrial and ventricular electrophysiology exhibit remarkable differences. It can be concluded that further research on the "atrial level" is needed in order to clarify the potential impact of the affection of atrial ion channels by aldosterone and accordingly MR antagonism in "upstream" therapy of AF.


Assuntos
Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/metabolismo , Ventrículos do Coração/efeitos dos fármacos , Canais Iônicos/efeitos dos fármacos , Antagonistas de Receptores de Mineralocorticoides/uso terapêutico , Eletrofisiologia Cardíaca , Átrios do Coração/efeitos dos fármacos , Humanos , Transporte de Íons , Masculino , Sistema Renina-Angiotensina
10.
Pak J Pharm Sci ; 24(3): 383-7, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21715273

RESUMO

PURPOSE: Atrial fibrillation (AF) results in tachycardia-induced ionic remodeling. Pharmacological prevention of tachycardia-induced ionic remodeling not only with "classical" antiarrhythmics but also with drugs which provide a basis for some of the pillars of the so-called "upstream" therapy of AF like corticosteroids or statins has been proposed as a therapeutic strategy. Amongst other ion currents, atrial sodium current I(Na) and its tachycardia-induced alterations play an important role in AF pathophysiology. Thus, effects of a dexamethasone (DT) and atorvastatin treatment (AT) on atrial sodium current I(Na) and its tachycardia-induced remodeling were studied in a rabbit model. METHODS: 9 groups with 4 animals were examined. Atrial pacemaker leads were implanted in all animals. No rapid atrial pacing (600/min) was performed in the control group but for 24 or 120 hours in the respective pacing groups. Instrumentation and pacing did not differ from the respective drug groups but an additional treatment with dexamethasone or atorvastatin (7 days) was performed. RESULTS: Rapid atrial pacing (RAP, 600/min) reduced I(Na) after 24 hours (≈ -50%) with no further reduction after 120 hours. DT reduced I(Na) (≈ -20%), current densities in consecutively tachypaced animals did not differ from those in untreated animals. AT reduced INa similar as RAP, subsequent RAP did not further diminish I(Na). CONCLUSIONS: Impact of corticosteroids and statins on INa and its tachycardia-induced alterations also contribute to the mode of action of these substances in upstream treatment of atrial fibrillation.


Assuntos
Cardiotônicos/farmacologia , Dexametasona/farmacologia , Átrios do Coração/efeitos dos fármacos , Ácidos Heptanoicos/farmacologia , Potenciais da Membrana/efeitos dos fármacos , Pirróis/farmacologia , Canais de Sódio/efeitos dos fármacos , Taquicardia/fisiopatologia , Animais , Atorvastatina , Estimulação Cardíaca Artificial/métodos , Modelos Animais de Doenças , Átrios do Coração/fisiopatologia , Potenciais da Membrana/fisiologia , Técnicas de Patch-Clamp/métodos , Coelhos , Canais de Sódio/fisiologia
11.
Am J Case Rep ; 22: e928089, 2021 Jan 18.
Artigo em Inglês | MEDLINE | ID: mdl-33456048

RESUMO

BACKGROUND Severe tricuspid valve regurgitation (TR) is associated with high cardiovascular mortality. Safe and feasible interventional approaches to treat severe TR are of clinical relevance. The MitraClip is a device that has been approved by the US Food and Drug Administration (FDA) for the repair of mitral valve lesions. Percutaneous femoral venous access with fluoroscopic and echocardiographic guidance is used to deliver a cobalt-chromium clip to secure the mitral valve leaflets. We report on an 85-year-old man with tricuspid valve regurgitation who underwent percutaneous edge-to-edge tricuspid valve leaflet plication with the new, advanced MitraClip XTR System. CASE REPORT An 85-year-old man with severe TR due to annulus dilation of the right ventricle and short septal leaflet presented repeatedly at our hospital with severe right heart failure symptoms. Transesophageal echocardiography revealed severe TR with a large coaptation gap size of 10.6 mm. Percutaneous edge-to-edge valve repair with the new-generation MitraClip System XTR with wider clip arms could overcome the large coaptation gap. We achieved a strong reduction of TR after deploying 2 MitraClips XTR. The patient recovered quickly and has not been admitted to hospital due to heart failure symptoms since the intervention for more than 6 months. CONCLUSIONS Previous studies have shown the safety and effectiveness of the MitraClip device and supported FDA approval for tricuspid valve repair. This report of a patient with complex tricuspid regurgitation demonstrated the feasible use of the new MitraClip XTR System, which improved edge-to-edge tricuspid valve repair due to its increased span and improved grip.


Assuntos
Anuloplastia da Valva Cardíaca/instrumentação , Insuficiência da Valva Tricúspide/cirurgia , Idoso de 80 Anos ou mais , Cateterismo Cardíaco , Anuloplastia da Valva Cardíaca/métodos , Humanos , Masculino , Insuficiência da Valva Tricúspide/diagnóstico por imagem
12.
Medicine (Baltimore) ; 100(13): e25333, 2021 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-33787630

RESUMO

ABSTRACT: Deceleration capacitiy for rapid risk stratification in stroke patientsCerebral ischemia is a major cause of neurologic deficit and patients suffering from ischemic stroke bear a relevant risk of mortality. Identifying stroke patients at high mortality risk is of crucial clinical relevance. Deceleration capacity of heart rate (DC) as a parameter of cardiac autonomic function is an excellent predictor of mortality in myocardial infarction and heart failure patients.The aim of our study was to evaluate whether DC provides prognostic information regarding mortality risk in patients with acute ischemic stroke.From September 2015 to March 2018 we prospectively enrolled consecutive patients presenting at the Stroke Unit of our university hospital with acute ischemic stroke who were in sinus rhythm. In these patients 24 hours-Holter-ECG recordings and evaluation of National Institute of Health Stroke Scale (NIHSS) were performed. DC was calculated according to a previously published algorithm. Primary endpoint was intrahospital mortality.Eight hundred seventy eight stroke patients were included in the study. Intrahospital mortality was 2.8% (25 patients). Both DC and NIHSS were significantly different between non-survivors and survivors (Mean ±â€ŠSD: DC: 4.1 ±â€Š2.8 ms vs 6.3 ±â€Š3.3 ms, P < .001) (NIHSS: 7.6 ±â€Š7.1 vs 4.3 ±â€Š5.5, P = .02). DC achieved an area under the curve value (AUC) of 0.708 for predicting intrahospital mortality, while the AUC value of NIHSS was 0.641. In a binary logistic regression analysis, DC, NIHSS and age were independent predictors for intrahospital mortality (DC: HR CI 95%: 0.88 (0.79-0.97); P = .01; NIHSS: HR CI 95%: 1.08 (1.02-1.15); P = .01; Age: HR CI 95%: 1.07 (1.02-1.11); P = .004. The combination of NIHSS, age and DC in a prediction model led to a significant improvement of the AUC, which was 0.757 (P < .001, incremental development index [IDI] 95% CI: 0.037 (0.018-0.057)), compared to the individual risk parameters.Our study demonstrated that DC is suitable for both objective and independent risk stratification in patients suffering from ischemic stroke. The application of a prediction model combining NIHSS, age and DC is superior to the single markers in identifying patients at high mortality risk.


Assuntos
Frequência Cardíaca/fisiologia , AVC Isquêmico/mortalidade , Modelos Cardiovasculares , Idoso , Idoso de 80 Anos ou mais , Desaceleração , Eletrocardiografia Ambulatorial/estatística & dados numéricos , Estudos de Viabilidade , Feminino , Mortalidade Hospitalar , Humanos , AVC Isquêmico/diagnóstico , AVC Isquêmico/fisiopatologia , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Prognóstico , Estudos Prospectivos , Curva ROC , Medição de Risco/métodos , Fatores de Tempo
14.
Cell Physiol Biochem ; 26(4-5): 495-502, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-21063087

RESUMO

BACKGROUND: Certain evidence points to a role of inflammation in AF pathophysiology. Thus, antiinflammatory treatment of AF is discussed. Effects of a dexamethasone treatment (7 days) on atrial ion currents (I(Ca,L), I(to), I(sus)) and their tachycardia-induced remodeling were studied in a rabbit model. METHODS: 6 groups of 4 animals each were built. Rapid atrial pacing (600 min) was performed for 24 and 120 hours with/ without dexamethasone treatment. Ion currents were measured using whole cell patch clamp method. RESULTS: Rapid atrial pacing reduced (I(Ca,L), I(to) was decreased after 24 hours but almost returned to control values after 120 hours. When dexamethasone-treated animals also underwent atrial tachypacing, pacing-induced reduction of I(Ca,L) was still observed after 24 hours and was even augmented after 120 hours compared to untreated but tachypaced animals. I(to) was not influenced by dexamethasone alone. In dexamethasone-treated animals, reduction of I(to) was not observed after 24 hours but occurred after 120 hours of atrial tachypacing. I(sus) was neither influenced by rapid atrial pacing nor by dexamethasone. Biophysical properties of all currents were affected neither by rapid atrial pacing nor by dexamethasone. CONCLUSION: Dexamethasone influenced tachycardia-induced alterations of atrial I(to). Our experiments give evidence that - amongst other anti-inflammatory action - impact of dexamethasone on ion currents and their tachycardia-induced alterations might also play a role in treatment/prevention of AF with steroids.


Assuntos
Anti-Inflamatórios/uso terapêutico , Fibrilação Atrial/tratamento farmacológico , Dexametasona/uso terapêutico , Átrios do Coração/fisiopatologia , Taquicardia/tratamento farmacológico , Animais , Fibrilação Atrial/fisiopatologia , Fenômenos Eletrofisiológicos , Átrios do Coração/efeitos dos fármacos , Inflamação/tratamento farmacológico , Inflamação/fisiopatologia , Coelhos , Taquicardia/fisiopatologia , Fatores de Tempo
15.
Catheter Cardiovasc Interv ; 73(6): 838-41, 2009 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-19301353

RESUMO

Paravalvular leakage following the atrioventricular valve replacement, though mostly harmless with insignificant morbidity, can result in heart failure and significant hemolysis that requires treatment. Reoperation is still the treatment of choice, but there is a high risk of recurrence, especially in patients with a history of endocarditis and/or those who have already undergone reoperation for paravalvular leakage. Recently, percutaneous closure of perivalvular leaks with occluders or coils have become an alternative to surgery. However, up to now, the collective of patients who benefit from this approach still has to be defined. Here, we present a case of a highly symptomatic 64-year-old male with severe hemolysis caused by paravalvular leakages after reoperation of a mechanical mitral valve replacement due to recurrent endocarditis.


Assuntos
Cateterismo Cardíaco , Endocardite/cirurgia , Implante de Prótese de Valva Cardíaca , Hemólise , Insuficiência da Valva Mitral/cirurgia , Falha de Prótese , Antibacterianos/uso terapêutico , Cateterismo Cardíaco/instrumentação , Remoção de Dispositivo , Dispneia/etiologia , Dispneia/terapia , Ecocardiografia Doppler em Cores , Endocardite/complicações , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Humanos , Masculino , Pessoa de Meia-Idade , Insuficiência da Valva Mitral/etiologia , Radiografia Intervencionista , Recidiva , Reoperação
16.
Alcohol Clin Exp Res ; 33(10): 1697-703, 2009 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19572985

RESUMO

BACKGROUND: In some patients, above-average alcohol consumption before occurrence of atrial fibrillation (AF) in terms of a "holiday heart syndrome" (HHS) can be determined. There is evidence that long before development of apparent alcohol-induced cardiomyopathy, above-average alcohol consumption generates an arrhythmogenic substrate which abets the onset of AF. Changes of atrial current densities in terms of an electrical remodeling after sustained short-term ethanol infusion in rabbits as a potential part of HHS pathophysiology were examined in this study. METHODS: Rabbits of the ethanol group (EG) received sustained short-term intravenous alcohol infusion for 120 hours (during infusion period, blood alcohol level did not fall below 158 mg/dl), whereas NaCl 0.9% was infused in the placebo group (PG). Using patch clamp technique in whole-cell mode, atrial current densities were measured and compared between both groups. RESULTS: Ethanol infusion did not alter current densities of I(to) [58.7 +/- 5.0 pA/pF (PG, n = 20 cells) vs. 53.9 +/- 5.0 pA/pF (EG, n = 24)], I(sus) [11.3 +/- 1.4 pA/pF (PG, n = 20) vs. 10.2 +/- 1.0 pA/pF (EG, n = 24)], and I(K1) [-1.6 +/- 0.3 pA/pF (PG, n = 17) vs. -2.0 +/- 0.3 pA/pF (EG, n = 22)]. However, alcohol infusion resulted in a remarkable reduction of I(Ca,L) current densities [-28.4 +/- 1.8 pA/pF (PG, n = 20) vs. -15.2 +/- 1.4 pA/pF (EG, n = 22)] and I(Na) [-75.4 +/- 3.6 pA/pF (PG, n = 17) vs. -35.4 +/- 4.4 pA/pF (EG, n = 21)], respectively. CONCLUSION: Sustained short-term ethanol infusion in rabbits alters atrial current densities. HHS might be favored by alcohol-induced atrial electrical remodeling.


Assuntos
Depressores do Sistema Nervoso Central/farmacologia , Etanol/farmacologia , Coração/efeitos dos fármacos , Canais Iônicos/efeitos dos fármacos , Miocárdio/metabolismo , Animais , Canais de Cálcio Tipo L/efeitos dos fármacos , Separação Celular , Regulação para Baixo/efeitos dos fármacos , Eletrofisiologia , Átrios do Coração , Técnicas In Vitro , Infusões Intravenosas , Potenciais da Membrana/efeitos dos fármacos , Técnicas de Patch-Clamp , Canais de Potássio/efeitos dos fármacos , Coelhos , Canais de Sódio/efeitos dos fármacos , Remodelação Ventricular/efeitos dos fármacos
17.
Int J Cardiol Heart Vasc ; 24: 100413, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31508480

RESUMO

INTRODUCTION: In this study, we evaluated right ventricular (RV) function before and after percutaneous mitral valve repair (PMVR) using conventional echocardiographic parameters and novel 3DE data sets acquired prior to and directly after the procedure. PATIENTS AND METHODS: Observational study on 45 patients undergoing PMVR at an university hospital. RESULTS: In the overall collective, the 3D RV-EF before and after PMVR showed no significant change (p = 0.16). While there was a significant increase of the fractional area change (FAC, from 23 [19-29] % to 28 [24-33] %, p = 0.001), no significant change of the tricuspid annular plane systolic excursion (TAPSE, from 17 ±â€¯6 mm to 18 ±â€¯5 mm (standard deviation), p = 0.33) was observed. Regarding patients with a reduced RV-EF (< 35%), a significant RV-EF improvement was observed (from 27 [23-34] % to 32.5 [30-39] % (p = 0.001). 71.4% of patients had an improved clinical outcome (improvement in 6-minute walk test and/or improvement in NYHA class of more than one grade), whereas clinical outcome did not improve in 28.6% of patients. Using univariate logistic regression analysis, the post-PMVR RV-EF (OR 1.15: 95% CI 1.02-1.29; p = 0.02) and the change in RV-EF (OR 1.13: 95% CI 1.02-1.25; p = 0.02) were significant predictors for improved clinical outcome at 6 months follow up. CONCLUSION: Thus, RV function may be an important non-invasive parameter to add to the predictive parameters indicating a potential clinical benefit from treatment of severe mitral regurgitation using PMVR.

18.
Thromb Haemost ; 119(10): 1590-1605, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31421642

RESUMO

As the number of, and the indications for, structural heart interventions are increasing worldwide, the optimal secondary prevention to reduce device thrombosis is becoming more important. To date, most of the recommendations are empiric. The current review discusses mechanisms behind device-related thrombosis, the available evidence with regard to antithrombotic regimen after cardiac device implantation, as well as providing an algorithm for identification of risk factors for device thrombogenicity and for management of device thrombosis after implantation of patent foramen ovale and left atrial appendage occluders, MitraClips/transcatheter mitral valve replacement, pacemaker leads, and left ventricular assist devices. Of note, the topic of antithrombotic therapy and thrombogenicity of prostheses in aortic position (transcatheter aortic valve replacement, surgical, mechanical, and bioprostheses) is not part of the present article and is discussed in detail in other contemporary focused articles.


Assuntos
Cardiologia/tendências , Fibrinolíticos/uso terapêutico , Insuficiência Cardíaca/terapia , Próteses Valvulares Cardíacas/efeitos adversos , Algoritmos , Bioprótese , Cateterismo Cardíaco/instrumentação , Procedimentos Cirúrgicos Cardíacos , Forame Oval Patente/complicações , Insuficiência Cardíaca/fisiopatologia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Coração Auxiliar/efeitos adversos , Humanos , Valva Mitral/cirurgia , Desenho de Prótese , Medição de Risco , Fatores de Risco , Trombose/etiologia , Resultado do Tratamento
19.
J Am Heart Assoc ; 8(13): e011366, 2019 07 02.
Artigo em Inglês | MEDLINE | ID: mdl-31248323

RESUMO

Background This study analyzed the effects on long-term outcome of residual mitral regurgitation ( MR ) and mean mitral valve pressure gradient ( MVPG ) after percutaneous edge-to-edge mitral valve repair using the MitraClip system. Methods and Results Two hundred fifty-five patients who underwent percutaneous edge-to-edge mitral valve repair were analyzed. Kaplan-Meier and Cox regression analyses were performed to evaluate the impact of residual MR and MVPG on clinical outcome. A combined clinical end point (all-cause mortality, MV surgery, redo procedure, implantation of a left ventricular assist device) was used. After percutaneous edge-to-edge mitral valve repair, mean MVPG increased from 1.6±1.0 to 3.1±1.5 mm Hg ( P<0.001). Reduction of MR severity to ≤2+ postintervention was achieved in 98.4% of all patients. In the overall patient cohort, residual MR was predictive of the combined end point while elevated MVPG >4.4 mm Hg was not according to Kaplan-Meier and Cox regression analyses. We then analyzed the cohort with degenerative and that with functional MR separately to account for these different entities. In the cohort with degenerative MR , elevated MVPG was associated with increased occurrence of the primary end point, whereas this was not observed in the cohort with functional MR . Conclusions MVPG >4.4 mm Hg after MitraClip implantation was predictive of clinical outcome in the patient cohort with degenerative MR . In the patient cohort with functional MR , MVPG >4.4 mm Hg was not associated with increased clinical events.


Assuntos
Cateterismo Cardíaco , Anuloplastia da Valva Mitral , Insuficiência da Valva Mitral/cirurgia , Pressão , Idoso , Idoso de 80 Anos ou mais , Ecocardiografia , Feminino , Coração Auxiliar , Humanos , Estimativa de Kaplan-Meier , Masculino , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/etiologia , Insuficiência da Valva Mitral/fisiopatologia , Mortalidade , Prognóstico , Modelos de Riscos Proporcionais , Reoperação , Índice de Gravidade de Doença , Resultado do Tratamento
20.
Pacing Clin Electrophysiol ; 31(6): 652-9, 2008 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-18507536

RESUMO

BACKGROUND: Catheter ablation has become the first line of therapy in patients with symptomatic recurrent, drug-refractory atrial fibrillation (AF). The occurrence of an atrioesophageal fistula is a rare but serious complication after AF-ablation procedures. This risk is even present during segmental pulmonary vein (PV) ablation procedures because the esophagus does frequently have a very close anatomical relationship to the right or left PV ostia. The aim of the present study was to analyze whether the exclusion of areas adjacent to the esophagus does have a significant effect on the success rates after segmental pulmonary vein ablation procedures. METHODS: Forty-three consecutive patients with symptomatic paroxysmal AF were enrolled in this study. In all patients, a segmental PV ablation procedure was performed. The procedures were facilitated by a 3D real-time visualization of the circumferential mapping catheter placed in the pulmonary veins using the NavX system (St. Jude Medical, St. Paul, MN, USA; open irrigated tip ablation catheter; 43 degrees C; 30 W). In 21 patients, a complete ostial PV isolation was attempted regardless of the anatomical relationship between the ablation sites and the esophagus (group A). In the remaining 22 patients, the esophagus was marked by a stomach tube and areas adjacent to the esophagus were excluded from the ablation procedure (group B). After discharge, patients were scheduled for repeated visits at the arrhythmia clinic at 1, 3, and 6 months after the ablation procedure. RESULTS: The segmental pulmonary vein ablation procedure could be performed as planned in all patients. In group A, all pulmonary veins could be isolated successfully in 14 out of 21 patients (67%). A mean number of 3.7 pulmonary veins (SD +/- 0.5 PVs) were isolated per patient. The main reasons for an incomplete PV isolation were: small diameter of the PVs, side branches close to the ostium, or poorly accessible PV ostia. In group B, all PVs could be isolated successfully in only 12 out of 22 patients (55%; P = 0.54). A mean number of 3.2 PVs (SD +/- 0.9 PVs) were isolated per patient (P = 0.05). This was mostly due to a close anatomical relationship to the esophagus. The ablation strategy had to be modified in 16/22 patients in group B because of a close anatomical relationship between the left (n = 10) or right (n = 6) PV ostia and the esophagus. After 3 months, the percentage of patients free from an AF recurrence was not significantly different between the two groups (90% vs 95%; P = 0.61). After 6 months, there was no significant difference between the success rates either (81% vs 82%; P = 1.0). There were no major complications in both groups. CONCLUSIONS: The exclusion of areas adjacent to the esophagus results in a moderately higher percentage of incompletely isolated PVs. However, it does not have a significant effect on the AF recurrence rate during short-term and mid-term follow-up.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Esôfago/cirurgia , Sistema de Condução Cardíaco/cirurgia , Veias Pulmonares/cirurgia , Idoso , Fibrilação Atrial/diagnóstico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA