Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
1.
Neuroradiology ; 66(7): 1161-1176, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38676750

RESUMO

PURPOSE: Intracranial hypertension (IH) frequently complicates cerebral venous thrombosis (CVT). Distinct neuroimaging findings are associated with IH, yet their discriminative power, reversibility and factors favoring normalization in prospective CVT patients are unknown. We determined test performance measures of neuroimaging signs in acute CVT patients, their longitudinal change under anticoagulation, association with IH at baseline and with recanalization at follow-up. METHODS: We included 26 consecutive acute CVT patients and 26 healthy controls. Patients were classified as having IH based on CSF pressure > 25 cmH2O and/or papilledema on ophthalmological examination or ocular MRI. We assessed optic nerve sheath diameter (ONSD), optic nerve tortuousity, bulbar flattening, lateral and IVth ventricle size, pituitary configuration at baseline and follow-up, and their association with IH and venous recanalization. RESULTS: 46% of CVT patients had IH. ONSD enlargement > 5.8 mm, optic nerve tortuousity and pituitary grade ≥ III had highest sensitivity, ocular bulb flattening and pituitary grade ≥ III highest specificity for IH. Only ONSD reliably discriminated IH at baseline. Recanalization was significantly associated with regressive ONSD and pituitary grade. Other neuroimaging signs tended to regress with recanalization. After treatment, 184.9 ± 44.7 days after diagnosis, bulbar flattening resolved, whereas compared with controls ONSD enlargement (p < 0.001) and partially empty sella (p = 0.017), among other indicators, persisted. CONCLUSION: ONSD and pituitary grading have a high diagnostic value in diagnosing and monitoring CVT-associated IH. Given their limited sensitivity during early CVT and potentially persistent alterations following IH, neuroimaging indicators can neither replace CSF pressure measurement in diagnosing IH, nor determine the duration of anticoagulation.


Assuntos
Hipertensão Intracraniana , Trombose Intracraniana , Trombose Venosa , Humanos , Masculino , Feminino , Hipertensão Intracraniana/diagnóstico por imagem , Adulto , Trombose Intracraniana/diagnóstico por imagem , Trombose Intracraniana/complicações , Trombose Venosa/diagnóstico por imagem , Trombose Venosa/complicações , Sensibilidade e Especificidade , Imageamento por Ressonância Magnética/métodos , Neuroimagem/métodos , Pessoa de Meia-Idade , Estudos de Casos e Controles , Estudos Prospectivos
2.
Neuroradiology ; 65(3): 463-477, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36445465

RESUMO

PURPOSE: Intracranial hypertension (IH) can complicate cerebral venous thrombosis (CVT), potentially causing permanent visual loss. Current knowledge on risk factors for the development of IH following CVT is scarce. We applied a compound classifier (CSF opening pressure > 25 cmH2O, papilledema, or optic disc protrusion on MRI) as a surrogate for IH and studied the predictive value of thrombus location, the number of thrombosed segments, and thrombus volume. METHODS: We prospectively included 26 patients with acute CVT and complete MRI data. IH was defined by CSF opening pressure > 25 cmH2O, papilledema, or optic disc protrusion on MRI. Using high-resolution contrast-enhanced venography, we determined the thrombus location, number of thrombosed segments, and thrombus volume. We analyzed their association with IH by logistic regression, their predictive power by the area under the receiver operating characteristic curve, and their association with CSF opening pressure by linear regression. RESULTS: IH occurred in 46% of CVT patients and was associated with higher thrombus volume (AUC 0.759, p = 0.025) and superior sagittal sinus thrombosis both alone (OR 2.086, p = 0.049) and combined with transverse sinus thrombosis (OR 2.014, p = 0.028). Effects in patients presenting CSF opening pressure > 25 cm H2O and the compound classifier were consistent. Thrombus volume > 4 ml was the single most important predictor of higher CSF opening pressure (ß = 0.566, p = 0.035), increasing IH risk. CONCLUSION: Larger thrombus volume, dominant transverse sinus occlusion, and extensive superior sagittal combined with transverse sinus thrombosis were associated with IH. Thrombus volumetry might identify patients at risk for IH and direct further clinical evaluation.


Assuntos
Deslocamento do Disco Intervertebral , Hipertensão Intracraniana , Trombose Intracraniana , Trombose do Seio Lateral , Papiledema , Trombose , Trombose Venosa , Humanos , Papiledema/complicações , Trombose do Seio Lateral/complicações , Hipertensão Intracraniana/complicações , Trombose Intracraniana/complicações , Fatores de Risco , Trombose/complicações
3.
J Magn Reson Imaging ; 51(1): 205-217, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31102341

RESUMO

BACKGROUND: Hemodynamic alterations of extracranial veins are considered an etiologic factor in multiple sclerosis (MS). However, ultrasound and MRI studies could not confirm a pathophysiological link. Because of technical challenges using standard diagnostics, information about the involvement of superficial intracranial veins in proximity to the affected brain in MS is scarce. PURPOSE: To comprehensively investigate the hemodynamics of intracranial veins and of the venous outflow tract in MS patients and controls. STUDY TYPE: Prospective. POPULATION: Twenty-eight patients with relapsing-remitting MS (EDSS1.9 ± 1.1; range 0-3) and 41 healthy controls. FIELD STRENGTH/SEQUENCE: 3T/2D phase-contrast and time-resolved 4D flow MRI, extra- and transcranial sonography. ASSESSMENT: Hemodynamics within the superficial and deep intracranial venous system and outflow tract including the internal, basal, and great cerebral vein, straight, superior sagittal, and transverse sinuses, internal jugular and vertebral veins. Sonography adhered to the chronic cerebrospinal venous insufficiency (CCSVI) criteria. STATISTICAL TESTS: Multivariate repeated measure analysis of variance, Student's two-sample t-test, chi-square, Fisher's exact test; separate analysis of the entire cohort and 32 age- and sex-matched participants. RESULTS: Multi- and univariate main effects of the factor group (MS patient vs. control) and its interactions with the factor vessel position (lower flow within dorsal superior sagittal sinus in MS, 3 ± 1 ml/s vs. 3.8 ± 1 ml/s; P < 0.05) in the uncontrolled cohort were attributable to age-related differences. Age- and sex-matched pairs showed a different velocity gradient in a single segment within the deep cerebral veins (great cerebral vein, vena cerebri magna [VCM] 7.6 ± 1.7 cm/s; straight sinus [StS] 10.5 ± 2.2 cm/s vs. volunteers: VCM 9.2 ± 2.3 cm/s; StS 10.2 ± 2.3 cm/s; P = 0.01), reaching comparable velocities instantaneously downstream. Sonography was not statistically different between groups. DATA CONCLUSION: Consistent with previous studies focusing on extracranial hemodynamics, our comprehensive analysis of intracerebral venous blood flow did not reveal relevant differences between MS patients and controls. Level of Evidence 1. Technical Efficacy Stage 3. J. Magn. Reson. Imaging 2020;51:205-217.


Assuntos
Veias Cerebrais/diagnóstico por imagem , Veias Cerebrais/fisiopatologia , Hemodinâmica/fisiologia , Imageamento por Ressonância Magnética/métodos , Esclerose Múltipla/fisiopatologia , Ultrassonografia/métodos , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Esclerose Múltipla/diagnóstico , Estudos Prospectivos , Adulto Jovem
4.
Int J Mol Sci ; 21(22)2020 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-33203140

RESUMO

Complex neuropsychiatric-cardiac syndromes can be genetically determined. For the first time, the authors present a syndromal form of short QT syndrome in a 34-year-old German male patient with extracardiac features with predominant psychiatric manifestation, namely a severe form of secondary high-functioning autism spectrum disorder (ASD), along with affective and psychotic exacerbations, and severe dental enamel defects (with rapid wearing off his teeth) due to a heterozygous loss-of-function mutation in the CACNA1C gene (NM_000719.6: c.2399A > C; p.Lys800Thr). This mutation was found only once in control databases; the mutated lysine is located in the Cav1.2 calcium channel, is highly conserved during evolution, and is predicted to affect protein function by most pathogenicity prediction algorithms. L-type Cav1.2 calcium channels are widely expressed in the brain and heart. In the case presented, electrophysiological studies revealed a prominent reduction in the current amplitude without changes in the gating behavior of the Cav1.2 channel, most likely due to a trafficking defect. Due to the demonstrated loss of function, the p.Lys800Thr variant was finally classified as pathogenic (ACMG class 4 variant) and is likely to cause a newly described Cav1.2 channelopathy.


Assuntos
Arritmias Cardíacas , Transtorno Autístico , Canais de Cálcio Tipo L , Canalopatias , Esmalte Dentário , Mutação com Perda de Função , Transtornos do Humor , Adulto , Arritmias Cardíacas/genética , Arritmias Cardíacas/metabolismo , Arritmias Cardíacas/patologia , Transtorno Autístico/genética , Transtorno Autístico/metabolismo , Transtorno Autístico/patologia , Canais de Cálcio Tipo L/genética , Canais de Cálcio Tipo L/metabolismo , Canalopatias/genética , Canalopatias/metabolismo , Canalopatias/patologia , Esmalte Dentário/anormalidades , Esmalte Dentário/metabolismo , Esmalte Dentário/patologia , Humanos , Masculino , Transtornos do Humor/genética , Transtornos do Humor/metabolismo , Transtornos do Humor/patologia
5.
Stroke ; 48(3): 671-677, 2017 03.
Artigo em Inglês | MEDLINE | ID: mdl-28179559

RESUMO

BACKGROUND AND PURPOSE: Cerebral venous thrombosis (CVT) affects venous hemodynamics and can provoke severe stroke and chronic intracranial hypertension. We sought to comprehensively analyze 3-dimensional blood flow and hemodynamic alterations during acute CVT including collateral recruitment and at follow-up. METHODS: Twenty-two consecutive patients with acute CVT were prospectively included and underwent routine brain magnetic resonance imaging (MRI) and 4-dimensional flow MRI at 3 T for the in vivo assessment of cerebral blood flow. Neurological and MRI follow-up at 6 months was performed in 18 patients. RESULTS: Three-dimensional blood flow visualization and quantification of large dural venous sinuses and deep cerebral veins was successfully performed in all patients. During acute CVT, we observed abnormal flow patterns including stagnant flow, flow acceleration in stenoses, and change of flow directions. In patients with complete recanalization, flow trajectories resembled those known from previously published 4-dimensional flow MRI data in healthy adults. There was a trend toward a relationship between occluded segments and cerebral lesions (not significant). Furthermore, patients with versus without cerebral lesions showed increased mean (0.08±0.09 versus 0.005±0.014 m/s) and peak velocities (0.18±0.21 versus 0.006±0.02 m/s) within partially thrombosed left and right transverse sinuses (P<0.05) at baseline. CONCLUSIONS: Four-dimensional flow MRI was successfully applied for the 3-dimensional visualization and quantification of venous hemodynamics in patients with CVT and provided new dynamic information regarding vessel recanalization. This technique seems promising to investigate the contribution of hemodynamic parameters and collaterals in a larger cohort to identify those at risk of stroke.


Assuntos
Veias Cerebrais/diagnóstico por imagem , Trombose Intracraniana/diagnóstico por imagem , Imageamento por Ressonância Magnética , Trombose dos Seios Intracranianos/patologia , Trombose Venosa/diagnóstico por imagem , Doença Aguda , Adolescente , Adulto , Idoso , Circulação Cerebrovascular/fisiologia , Feminino , Seguimentos , Humanos , Imageamento Tridimensional , Hipertensão Intracraniana/diagnóstico por imagem , Hipertensão Intracraniana/etiologia , Hipertensão Intracraniana/fisiopatologia , Trombose Intracraniana/complicações , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Trombose Venosa/complicações , Adulto Jovem
6.
J Cardiovasc Magn Reson ; 19(1): 67, 2017 Sep 06.
Artigo em Inglês | MEDLINE | ID: mdl-28877718

RESUMO

BACKGROUND: It was our purpose to identify vulnerable plaques in the thoracic aorta using 3D multi-contrast CMR and estimate the risk of cerebral embolization using 4D flow CMR in cryptogenic stroke patients and controls. METHODS: One hundred patients (40 with cryptogenic stroke, 60 ophthalmologic controls matched for age, sex and presence of hypertension) underwent a novel 3D multi-contrast (T1w, T2w, PDw) CMR protocol at 3 Tesla for plaque detection and characterization within the thoracic aorta, which was combined with 4D flow CMR for mapping potential embolization pathways. Plaque morphology was assessed in consensus reading by two investigators and classified according to the modified American-Heart-Association (AHA) classification of atherosclerotic plaques. RESULTS: In the thoracic aorta, plaques <4 mm thickness were found in a similar number of stroke patients and controls [23 (57.5%) versus 33 (55.0%); p = 0.81]. However, plaques ≥4 mm were more frequent in stroke patients [22 (55.0%) versus 10 (16.7%); p < 0.001]. Of those patients with plaques ≥4 mm, seven (17.5%) stroke patients and two (3.3%) controls (p < 0.001) had potentially vulnerable AHA type VI plaques. Six stroke patients with vulnerable AHA type VI plaques ≥4 mm had potential embolization pathways connecting the plaque, located in the aortic arch (n = 3) and proximal descending aorta (n = 3), with the individual territory of stroke, which made them the most likely source of stroke in those patients. CONCLUSIONS: Our findings underline the significance of ≥4 mm thick and vulnerable plaques in the aortic arch and descending aorta as a relevant etiology of stroke. CLINICAL TRIAL REGISTRATION: Unique identifier: DRKS00006234 ; date of registration: 11/06/2014.


Assuntos
Aorta Torácica/diagnóstico por imagem , Doenças da Aorta/diagnóstico por imagem , Aterosclerose/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Embolia Intracraniana/diagnóstico por imagem , Angiografia por Ressonância Magnética/métodos , Placa Aterosclerótica , Acidente Vascular Cerebral/diagnóstico por imagem , Idoso , Doenças da Aorta/complicações , Aterosclerose/complicações , Estudos de Casos e Controles , Meios de Contraste/administração & dosagem , Feminino , Humanos , Embolia Intracraniana/etiologia , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Fatores de Risco , Acidente Vascular Cerebral/etiologia
7.
Eur Radiol ; 25(8): 2371-80, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25638218

RESUMO

OBJECTIVES: To visualize and quantify physiological blood flow of intracranial veins in vivo using time-resolved, 3D phase-contrast MRI (4D flow MRI), and to test measurement accuracy. METHODS: Fifteen healthy volunteers underwent repeated ECG-triggered 4D flow MRI (3 Tesla, 32-channel head coil). Intracranial venous blood flow was analysed using dedicated software allowing for blood flow visualization and quantification in analysis planes at the superior sagittal, straight, and transverse sinuses. MRI was evaluated for intra- and inter-observer agreement and scan-rescan reproducibility. Measurements of the transverse sinuses were compared with transcranial two-dimensional duplex ultrasound. RESULTS: Visualization of 3D blood flow within cerebral sinuses was feasible in 100 % and within at least one deep cerebral vein in 87 % of the volunteers. Blood flow velocity/volume increased along the superior sagittal sinus and was lower in the left compared to the right transverse sinus. Intra- and inter-observer reliability and reproducibility of blood flow velocity (mean difference 0.01/0.02/0.02 m/s) and volume (mean difference 0.0002/-0.0003/0.00003 l/s) were good to excellent. High/low velocities were more pronounced (8 % overestimation/9 % underestimation) in MRI compared to ultrasound. CONCLUSIONS: Four-dimensional flow MRI reliably visualizes and quantifies three-dimensional cerebral venous blood flow in vivo and is promising for studies in patients with sinus thrombosis and related diseases. KEY POINTS: • 4D flow MRI can be used to visualize and quantify physiological cerebral venous haemodynamics • Flow quantification within cerebral sinuses reveals high reliability and accuracy of 4D flow MRI • Blood flow volume and velocity increase along the superior sagittal sinus • Limited spatial resolution currently precludes flow quantification in small cerebral veins.


Assuntos
Veias Cerebrais/fisiologia , Adulto , Velocidade do Fluxo Sanguíneo/fisiologia , Circulação Cerebrovascular/fisiologia , Cavidades Cranianas/fisiologia , Feminino , Humanos , Imageamento Tridimensional , Angiografia por Ressonância Magnética , Masculino , Imagem Multimodal , Estudos Prospectivos , Reprodutibilidade dos Testes , Trombose dos Seios Intracranianos/fisiopatologia , Ultrassonografia Doppler Dupla , Adulto Jovem
9.
JMIR Res Protoc ; 13: e51683, 2024 Feb 13.
Artigo em Inglês | MEDLINE | ID: mdl-38349728

RESUMO

BACKGROUND: Endovascular thrombectomy (ET), combined with intravenous thrombolysis if possible, is an effective treatment option for patients with stroke who have confirmed anterior large vessel occlusion (aLVO). However, ET is mainly limited to comprehensive stroke centers (CSCs), resulting in a lack of ET capacity in remote, sparsely populated areas. Most stroke networks use the "Drip and Ship" or "Mothership" strategy, resulting in either delayed ET or intravenous thrombolysis, respectively. OBJECTIVE: This study protocol introduces the Leitstellen-Basierte Erkennung von Schlaganfall-Patienten für eine Thrombektomie und daraufhin abgestimmte Optimierung der Rettungskette (LESTOR) strategy, developed to optimize the preclinical part of the stroke chain of survival to improve the clinical outcome of patients with suspected aLVO stroke. This involves refining the dispatch strategy for identifying patients with acute aLVO stroke using a phone-based aLVO query. This includes dispatching emergency physicians and emergency medical services (EMS) to urban emergency sites, as well as dispatching helicopter EMS to remote areas. If a highly suspected aLVO is identified after a standardized aLVO score evaluation during a structured examination at the emergency scene, prompt transport to a CSC should be prioritized. METHODS: The LESTOR study is a controlled, nonrandomized study implementing the LESTOR strategy, with a stepped-wedge, cluster trial design in 6 districts in southwest Germany. In an interprofessional, iterative approach, an aLVO query or dispatch protocol intended for use by dispatchers, followed by a coordinated aLVO examination score for use by EMS, is being developed, evaluated, and pretested in a simulation study. After the training of all participating health care professionals with the corresponding final aLVO query, the LESTOR strategy is being implemented stepwise. Patients otherwise receive usual stroke care in both the control and intervention groups. The primary outcome is the modified Rankin Scale at 90 days in patients with stroke receiving endovascular treatment. We will use a generalized linear mixed model for data analysis. This study is accompanied by a cost-effectiveness analysis and a qualitative process evaluation. RESULTS: This paper describes and discusses the protocol for this controlled, nonrandomized LESTOR study. Enrollment was completed in June 2023. Data analysis is ongoing and the first results are expected to be submitted for publication in 2024. The project started in April 2020 and will end in February 2024. CONCLUSIONS: We expect that the intervention will improve the clinical outcome of patients with aLVO stroke, especially outside the catchment areas of CSCs. The results of the accompanying process evaluation and the cost-effectiveness analysis will provide further insights into the implementation process and allow for a better interpretation of the results. TRIAL REGISTRATION: German Clinical Trials Register DRKS00022152; https://drks.de/search/de/trial/DRKS00022152. INTERNATIONAL REGISTERED REPORT IDENTIFIER (IRRID): DERR1-10.2196/51683.

10.
Clin Neuroradiol ; 34(2): 391-401, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38277058

RESUMO

PURPOSE: To quantify the effects of CSF pressure alterations on intracranial venous morphology and hemodynamics in idiopathic intracranial hypertension (IIH) and spontaneous intracranial hypotension (SIH) and assess reversibility when the underlying cause is resolved. METHODS: We prospectively examined venous volume, intracranial venous blood flow and velocity, including optic nerve sheath diameter (ONSD) as a noninvasive surrogate of CSF pressure changes in 11 patients with IIH, 11 age-matched and sex-matched healthy controls and 9 SIH patients, before and after neurosurgical closure of spinal dural leaks. We applied multiparametric MRI including 4D flow MRI, time-of-flight (TOF) and T2-weighted half-Fourier acquisition single-shot turbo-spin echo (HASTE). RESULTS: Sinus volume overlapped between groups at baseline but decreased after treatment of intracranial hypotension (p = 0.067) along with a significant increase of ONSD (p = 0.003). Blood flow in the middle and dorsal superior sagittal sinus was remarkably lower in patients with higher CSF pressure (i.e., IIH versus controls and SIH after CSF leak closure) but blood flow velocity was comparable cross-sectionally between groups and longitudinally in SIH. CONCLUSION: We were able to demonstrate the interaction of CSF pressure, venous volumetry, venous hemodynamics and ONSD using multiparametric brain MRI. Closure of CSF leaks in SIH patients resulted in symptoms suggestive of increased intracranial pressure and caused a subsequent decrease of intracranial venous volume and of blood flow within the superior sagittal sinus while ONSD increased. In contrast, blood flow parameters from 4D flow MRI did not discriminate IIH, SIH and controls as hemodynamics at baseline overlapped at most vessel cross-sections.


Assuntos
Pressão do Líquido Cefalorraquidiano , Circulação Cerebrovascular , Hipotensão Intracraniana , Pseudotumor Cerebral , Humanos , Feminino , Masculino , Adulto , Hipotensão Intracraniana/diagnóstico por imagem , Hipotensão Intracraniana/fisiopatologia , Circulação Cerebrovascular/fisiologia , Pseudotumor Cerebral/fisiopatologia , Pseudotumor Cerebral/diagnóstico por imagem , Pseudotumor Cerebral/cirurgia , Pressão do Líquido Cefalorraquidiano/fisiologia , Veias Cerebrais/diagnóstico por imagem , Veias Cerebrais/fisiopatologia , Pessoa de Meia-Idade , Angiografia por Ressonância Magnética/métodos , Velocidade do Fluxo Sanguíneo/fisiologia , Imageamento Tridimensional/métodos , Estudos Prospectivos , Reprodutibilidade dos Testes , Imageamento por Ressonância Magnética/métodos , Sensibilidade e Especificidade , Hemodinâmica/fisiologia , Hipertensão Intracraniana/fisiopatologia , Hipertensão Intracraniana/diagnóstico por imagem
11.
Brain Behav ; 14(3): e3450, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38450998

RESUMO

INTRODUCTION: Aphasia and neglect in combination with hemiparesis are reliable indicators of large anterior vessel occlusion (LAVO). Prehospital identification of these symptoms is generally considered difficult by emergency medical service (EMS) personnel. Therefore, we evaluated the simple non-paretic-hand-to-opposite-ear (NPE) test to identify aphasia and neglect with a single test. As the NPE test includes a test for arm paresis, we also evaluated the diagnostic ability of the NPE test to detect LAVO in patients with suspected stroke. METHODS: In this prospective observational study, we performed the NPE test in 1042 patients with suspected acute stroke between May 2021 and May 2022. We analyzed the correlation between the NPE test and the aphasia/neglect items of the National Institutes of Health Stroke Scale. Additionally, the predictive values of the NPE test for LAVO detection were calculated. RESULTS: The NPE test showed a strong, significant correlation with both aphasia and neglect. A positive NPE test result predicted LAVO with a sensitivity of 0.70, a specificity of 0.88, and an accuracy of 0.85. Logistic regression analysis showed an odds ratio of 16.14 (95% confidence interval 10.82-24.44) for predicting LAVO. CONCLUSION: The NPE test is a simple test for the detection of both aphasia and neglect. With its predictive values for LAVO detection being comparable to the results of LAVO scores in the prehospital setting, this simple test might be a promising test for prehospital LAVO detection by EMS personnel. Further prospective prehospital validation is needed.


Assuntos
Afasia , Serviços Médicos de Emergência , Acidente Vascular Cerebral , Estados Unidos , Humanos , Acidente Vascular Cerebral/complicações , Acidente Vascular Cerebral/diagnóstico , Afasia/diagnóstico , Afasia/etiologia , Mãos , Razão de Chances
12.
BMC Neurol ; 13: 187, 2013 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-24289136

RESUMO

BACKGROUND: Quantification of the optic nerve sheath diameter (ONSD) by transbulbar sonography is a promising non-invasive technique for the detection of altered intracranial pressure. In order to establish this method as follow-up tool in diseases with intracranial hyper- or hypotension scan-rescan reproducibility and accuracy need to be systematically investigated. METHODS: The right ONSD of 15 healthy volunteers (mean age 24.5 ± 0.8 years) were measured by both transbulbar sonography (9 - 3 MHz) and 3 Tesla MRI (half-Fourier acquisition single-shot turbo spin-echo sequences, HASTE) 3 and 5 mm behind papilla. All volunteers underwent repeated ultrasound and MRI examinations in order to assess scan-rescan reproducibility and accuracy. Moreover, inter- and intra-observer variabilities were calculated for both techniques. RESULTS: Scan-rescan reproducibility was robust for ONSD quantification by sonography and MRI at both depths (r > 0.75, p ≤ 0.001, mean differences < 2%). Comparing ultrasound- and MRI-derived ONSD values, we found acceptable agreement between both methods for measurements at a depth of 3 mm (r = 0.72, p = 0.002, mean difference < 5%). Further analyses revealed good inter- and intra-observer reliability for sonographic measurements 3 mm behind the papilla and for MRI at 3 and 5 mm (r > 0.82, p < 0.001, mean differences < 5%). CONCLUSIONS: Sonographic ONSD quantification 3 mm behind the papilla can be performed with good reproducibility, measurement accuracy and observer agreement. Thus, our findings emphasize the feasibility of this technique as a non-invasive bedside tool for longitudinal ONSD measurements.


Assuntos
Imageamento por Ressonância Magnética , Bainha de Mielina/diagnóstico por imagem , Nervo Óptico/anatomia & histologia , Nervo Óptico/diagnóstico por imagem , Ultrassonografia Doppler Transcraniana , Adulto , Voluntários Saudáveis , Humanos , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Estudos Retrospectivos , Adulto Jovem
13.
Thromb Haemost ; 121(10): 1345-1352, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33657624

RESUMO

BACKGROUND AND PURPOSE: Dural arteriovenous fistulae (DAVFs) can develop secondary to cerebral venous thrombosis (CVT). The incidence of DAVF has not yet been investigated prospectively. METHODS: Between July 2012 and January 2018, combined static and dynamic 4D MR venography (4D-combo-MRV) was performed in 24 consecutive patients at diagnosis of CVT and after 6 months. 3 Tesla magnetic resonance imaging with time of flight and contrast-enhanced magnetization-prepared rapid acquisition with gradient echo were performed at baseline to evaluate the extent of thrombosis and affected vessel segments. Baseline and follow-up 4D-combo-MRV were assessed for signs of DAVF. Interrater reliability of DAVF detection and the extent of recanalization were analyzed with kappa statistics. RESULTS: DAVFs were detected in 4/30 CVT patients (13.3%, 95% confidence interval [CI] 3.3-26.7). Two of 24 patients (8.3%, 95% CI: 0-20.8) had coincidental DAVF with CVT on admission. At follow-up, de novo formation of DAVF following CVT was seen in 2/24 patients (8.3%, 95% CI: 0-20.8). Both de novo DAVFs were low grade and benign fistulae (Cognard type 1, 2a), which had developed at previously thrombosed segments. Endovascular treatment was required in two high degree lesions (Cognard 2a + b) detected at baseline and in one de novo DAVF (Cognard 1) because of debilitating headache and tinnitus. Thrombus load, vessel recanalization, and frequency of cerebral lesions (hemorrhage, ischemia) were not associated with DAVF occurrence. CONCLUSION: This exploratory study showed that de novo DAVF formation occurs more frequently than previously described. Although de novo DAVFs were benign, 75% of all detected DAVFs required endovascular treatment. Therefore, screening for DAVF by dynamic MRV, such as 4D-combo-MRV, seems worthwhile in CVT patients.


Assuntos
Malformações Vasculares do Sistema Nervoso Central/diagnóstico por imagem , Angiografia Cerebral , Trombose Intracraniana/diagnóstico por imagem , Angiografia por Ressonância Magnética , Flebografia , Trombose Venosa/diagnóstico por imagem , Adulto , Malformações Vasculares do Sistema Nervoso Central/epidemiologia , Malformações Vasculares do Sistema Nervoso Central/terapia , Procedimentos Endovasculares , Feminino , Alemanha/epidemiologia , Humanos , Incidência , Trombose Intracraniana/epidemiologia , Trombose Intracraniana/terapia , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Valor Preditivo dos Testes , Estudos Prospectivos , Reprodutibilidade dos Testes , Resultado do Tratamento , Trombose Venosa/epidemiologia , Trombose Venosa/terapia
14.
Transl Vis Sci Technol ; 9(3): 24, 2020 02 21.
Artigo em Inglês | MEDLINE | ID: mdl-32742754

RESUMO

Purpose: Idiopathic intracranial hypertension (IIH) leads to optic nerve head swelling and optic atrophy if left untreated. We wanted to assess an easy to perform volumetric algorithm to detect and quantify papilledema in comparison to retinal nerve fiber layer (RNFL) analysis using optical coherence tomography (OCT). Methods: Participants with and without IIH underwent visual acuity testing at different contrast levels and static perimetry. Spectralis-OCT measurements comprised standard imaging of the peripapillary RNFL and macular ganglion cell layer (GCL). The optic nerve head volume (ONHV) was determined using the standard segmentation software and the 3.45 mm early treatment diabetic retinopathy study (ETDRS) grid, necessitating manual correction within Bruch membrane opening. Three neuro-ophthalmologists graded fundus images according to the Frisén scale. A mixed linear model (MLM) was used to determine differences between study groups. Sensitivity and specificity was evaluated using the area under the receiver-operating characteristic (ROC). Results: Twenty-one patients with IIH had an increased ONHV of 6.46 ± 2.36 mm3 as compared to 25 controls with 3.20 ± 0.25 mm3 (P < 0.001). The ONHV cutoff distinguishing IIH from controls was 3.97 mm3 (i.e. no patient with IIH had an ONHV below and no healthy individual above this value). The area under the curve (AUC) for ONHV was 0.99 and for the RNFL at 3.5 mm 0.90. The Frisén scale grading correlated higher with the ONHV (r = 0.90) than with the RNFL thickness (r = 0.68). ONHV measurements were highly reproducible in both groups (coefficient of variation <0.01%). Conclusions: OCT-based volumetry of the optic nerve head discriminates very accurately between individuals with and without IIH. It may serve as a useful adjunct to the rating with the subjective and ordinal Frisén scale. Translational Relevance: A simple OCT protocol run on the proprietary software of a commercial OCT device can reliably discriminate between normal optic nerve heads or pseudo-papilledema and true papilledema while being highly reproducible. Our normative data and OCT preset may be used in further clinical studies.


Assuntos
Disco Óptico , Papiledema , Pseudotumor Cerebral , Humanos , Fibras Nervosas , Disco Óptico/diagnóstico por imagem , Papiledema/diagnóstico , Pseudotumor Cerebral/complicações , Células Ganglionares da Retina , Tomografia de Coerência Óptica
15.
Int J Cardiovasc Imaging ; 34(6): 939-946, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29327165

RESUMO

4D flow MRI is an emerging technique that allows quantification of 3D blood flow in vivo. However, comparisons with methods of blood velocity quantification used in clinical routine are sparse. Therefore, we compared velocity quantification using 4D flow MRI with transthoracic and transesophageal echocardiography at the mitral and aortic valves and the aorta. Forty-eight stroke patients (age 67.3 ± 15.0 years) were examined by 4D flow MRI. Blood flow velocities were assessed using standardized 2D analysis planes positioned in the mitral valve (MV), aortic valve (AV), ascending aorta (AAo), and descending aorta (DAo) and were compared with echocardiography. MRI showed moderate-high correlations of systolic velocity values for the MV (r = 0.67, p < 0.001), AV (r = 0.77, p < 0.001), AAo (r = 0.93, p < 0.001), and DAo (r = 0.76, p < 0.001) along with moderate-high intraclass-correlation-coefficients: MV 0.79 (95% CI 0.62, 0.88), AV 0.86 (95% CI 0.75, 0.92), AAo 0.96 (95% CI 0.93, 0.98), and DAo 0.83 (95% CI 0.70, 0.90). However, MRI underestimated absolute systolic blood flow velocities compared with echocardiography by 8.6% for the MV (p = 0.07), 3.1% for the AV (p = 0.48), 10.7% for the AAo (p = 0.09), and 15.0% for the DAo (p = 0.01). Blood flow velocities obtained using 4D flow MRI and echocardiography at the MV, AV, and the ascending and DAo showed moderate to high correlations. Underestimation of absolute velocity values by MRI was low. Thus, 4D flow MRI seems ideally suited to comprehensively assess cardiac and aortic pathologies and related hemodynamic changes in future studies.


Assuntos
Aorta/diagnóstico por imagem , Valva Aórtica/diagnóstico por imagem , Velocidade do Fluxo Sanguíneo , Ecocardiografia/métodos , Imageamento por Ressonância Magnética/métodos , Valva Mitral/diagnóstico por imagem , Acidente Vascular Cerebral/fisiopatologia , Idoso , Idoso de 80 Anos ou mais , Aorta/fisiopatologia , Valva Aórtica/fisiopatologia , Ecocardiografia Transesofagiana/métodos , Feminino , Hemodinâmica , Humanos , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Valva Mitral/fisiopatologia , Valor Preditivo dos Testes , Fatores de Tempo
16.
Fluids Barriers CNS ; 14(1): 34, 2017 Dec 07.
Artigo em Inglês | MEDLINE | ID: mdl-29212505

RESUMO

BACKGROUND: We previously described inflammatory cerebrospinal fluid (CSF) alterations in a subgroup of patients with schizophreniform disorders and the synthesis of polyspecific intrathecal antibodies against different neurotropic infectious pathogens in some patients with bipolar disorders. Consequently, we have measured the prevalence of a positive MRZ reaction (MRZR)-a marker for a polyspecific, antiviral, intrathecal, humoral immune response composed of three antibody indices for the neurotropic viruses of measles (M), rubella (R), and varicella zoster (Z)-in these patients. METHODS: We analyzed paired CSF and serum samples of 39 schizophreniform and 39 bipolar patients. For comparison, we used a group of 48 patients with other inflammatory neurological disorders (OIND) and a cohort of 203 multiple sclerosis (MS) patients. RESULTS: We found a positive MRZR in two patients with schizophreniform disorders (5.1%); both suffered from schizodepressive disorders without any other signs suggestive of MS. None of the bipolar patients (0%) and four members of the OIND group (8.3%) showed a positive MRZR. In the MS cohort, a positive MRZR was found significantly more frequently [in 99 patients (48.8%)] than in the other patient groups (p > 0.001). In summary, we did not find a positive MRZR in a relevant subgroup of patients with schizophreniform or bipolar disorders. CONCLUSIONS: Our results indicate that the MRZR is highly specific to MS. Nevertheless, two schizodepressive patients also had a positive MRZR. This finding corresponds to the few MRZR-positive patients with OIND or other autoimmune disorders with central nervous involvement, implicating that the MRZR specificity for MS is high, but not 100%.


Assuntos
Anticorpos Antivirais/líquido cefalorraquidiano , Transtorno Bipolar/imunologia , Transtornos Psicóticos/imunologia , Adolescente , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Adulto Jovem
17.
J Neurol Sci ; 367: 15-7, 2016 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-27423555

RESUMO

OBJECTIVE: To report a case of a patient with multiple cerebral cavernous malformations (CCM). OBSERVATION: A 22year old man with mild von Willebrand disease presented with two occipital CCM, one of them with acute hemorrhage. Genetic testing for CCM1-3 did not reveal a mutation. Over a period of 54months, the patient suffered 26 new CCM hemorrhages despite multiple treatment attempts including thalidomide, simvastatin and hemostatic factors. Only after initiation of propranolol, which has already been successfully used in three children with giant cerebral cavernoma, the occurrence of new CCM with hemorrhages was completely stopped already at dose of 30mg daily - now for a period of 26months and without any other medications. CONCLUSION: This case suggests a protective role for propranolol in preventing the occurrence of new cerebral cavernoma with hemorrhages in adults with multiple CCM.


Assuntos
Hemangioma Cavernoso do Sistema Nervoso Central/tratamento farmacológico , Fármacos Neuroprotetores/uso terapêutico , Propranolol/uso terapêutico , Encéfalo/diagnóstico por imagem , Encéfalo/efeitos dos fármacos , Progressão da Doença , Seguimentos , Hemangioma Cavernoso do Sistema Nervoso Central/diagnóstico por imagem , Hemangioma Cavernoso do Sistema Nervoso Central/genética , Humanos , Masculino , Resultado do Tratamento , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA