Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 36
Filtrar
1.
Analyst ; 148(12): 2745-2757, 2023 Jun 12.
Artigo em Inglês | MEDLINE | ID: mdl-37191142

RESUMO

Raman spectroscopy enables the label-free assessment of cellular composition. While live cell analysis is the most accurate approach for cellular Raman spectroscopy, the analysis of fixed cells has proved to be very useful, particularly in collaborative projects where samples need to be serially examined by different laboratories or stored and reanalyzed at a later date. However, many chemicals that are widely used for cell fixation directly affect cellular biomolecules, yielding Raman spectra with missing or altered information. In this article, we compared the suitability of dry-fixation with saline versus chemical fixatives. We compared the Raman spectroscopy of saline dry-fixed cells with the more commonly used formaldehyde and methanol fixation and found that dry-fixed cell spectra preserved more cellular information than either chemical fixative. We also assessed the stability of dry-fixed cells over time and found that they were stable for at least 5 months. Finally, a comparison of dry-fixed and live cell spectra revealed effects due to the hydration state of the cells since they were recovered upon rehydrating dry-fixed samples. Thus, for fixed cell Raman spectroscopy, we recommend dry-fixation with unbuffered saline as a superior method to formaldehyde or methanol fixation.


Assuntos
Metanol , Análise Espectral Raman , Fixação de Tecidos/métodos , Análise Espectral Raman/métodos , Metanol/química , Fixadores/química , Fixadores/farmacologia , Formaldeído/química
2.
Analyst ; 145(6): 2070-2105, 2020 Mar 16.
Artigo em Inglês | MEDLINE | ID: mdl-32072996

RESUMO

Therapies based on injecting living cells into patients offer a huge potential to cure many degenerative and deadly diseases, with hundreds of clinical trials ongoing. Due to their complex nature, a basic understanding of their biochemical and functional characteristics, how to manufacture them for safe and efficacious therapy, and how to effectively implement them in clinical settings are very challenging. Raman spectroscopy could provide an information-rich, non-invasive, non-destructive analytical method to complement the use of conventional sample-based, infrequent and destructive biochemical assays typically employed to analyze and validate the quality of therapeutic cells. This article provides an overview of the current state of emerging cell therapies, and then reviews the related Raman spectroscopic state of the art analysis of human cells. This includes spectroscopic data processing considerations, the scope offered by technical variants of Raman spectroscopy, and analytical difficulties encountered by spectroscopists working with therapeutic cells. Finally, we outline a number of salient challenges as cell therapy products are translated from the laboratory to the clinic, and propose how Raman spectroscopy-based solutions could address these challenges.


Assuntos
Terapia Baseada em Transplante de Células e Tecidos , Células/química , Análise Espectral Raman/métodos , Animais , Humanos
3.
Analyst ; 145(7): 2812, 2020 04 07.
Artigo em Inglês | MEDLINE | ID: mdl-32129374

RESUMO

Correction for 'Applications of Raman spectroscopy in the development of cell therapies: state of the art and future perspectives' by Shreyas Rangan et al., Analyst, 2020, DOI: 10.1039/c9an01811e.

4.
Am J Phys Anthropol ; 167(2): 337-347, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-30159865

RESUMO

OBJECTIVES: The approximately 250 years old remains of the Kwäday Dän Ts'ìnchi man were found in a glacier in Canada. Studying the state of preservation of the corpse, we observed black deposits in his lung. Following this observation we wanted to determine: (1) location of the deposits in the lung tissue, (2) composition and origins of the deposits. METHODS: By light microscopy (LM) and transmission electron microscopy (TEM), we studied the deposits in the Kwäday Dän Ts'ìnchi man' s lung and compared it with distribution of anthracotic deposits in contemporary samples from the David Harwick Pathology Centre (DHPC). To determine chemical composition of the inclusions we used Raman spectroscopy. Scanning electron microscopy and elemental mapping was used for determine the chemical elements. RESULTS: The histopathological identification of anthracosis in the Kwäday Dän Ts'ìnchi man's lung allowed us to distinguish crushed parenchyma from conducting airway tissue and identification of particles using LM and TEM. Crystal particles were found using TEM. Ordered carbonaceous material (graphene and graphite), disordered carbonaceous material (soot) and what might be minerals (likely conglomerates) were found with Raman spectrometry. Gold and lead particles in the lung were discovered with scanning electron microscopy and elemental mapping. CONCLUSIONS: Presence of soot particles in anthracotic areas in the Kwäday Dän Ts'ìnchi man's lung probably were due to an inhalation of particles in open fires. Gold and lead particles are most likely of an environmental origin and may have been inhaled and could have impacted his health and his Champagne and Aishihik First Nations (CAFN) contemporaries.


Assuntos
Antracose , Pulmão , Adolescente , Antracose/diagnóstico por imagem , Antracose/história , Antracose/patologia , Colúmbia Britânica , Argila/química , Ouro/química , História do Século XVIII , História do Século XIX , Humanos , Chumbo/química , Pulmão/química , Pulmão/diagnóstico por imagem , Pulmão/patologia , Masculino , Microscopia , Múmias , Análise Espectral Raman
5.
Analyst ; 142(12): 2199-2210, 2017 Jun 12.
Artigo em Inglês | MEDLINE | ID: mdl-28537294

RESUMO

Blood banking is an essential aspect of modern medical care. When red blood cells (RBCs) are stored, they become damaged by various chemical processes, such as accumulation of their own waste products and oxidative injury, among others. These processes lead to the development of the RBC storage lesion, a complex condition where the severity is reflected through the morphology of the stored cells. It was hypothesized that Raman spectroscopy could be used to monitor certain structural and compositional changes associated with such ageing effects and that a relationship between these features and traditional morphology (as measured using a morphology index) could be observed. The hypothesis was tested by measuring spectral features associated with hemoglobin oxygenation from dry-fixed smears and liquid RBCs for twenty-nine different donors (combined), and comparing the trends with morphological scoring from seven of these donors. After appropriately fitting the two data sets to either power or linear curves, the oxygenation state was shown to change in a manner that was donor-dependent and that closely tracked morphological changes. This study suggests Raman analysis has promise for providing a rapid and objective measure of the cell quality of stored RBCs through measurements of hemoglobin oxygenation that is comparable to traditional morphological assessment.


Assuntos
Eritrócitos/química , Hemoglobinas/química , Análise Espectral Raman , Adulto , Idoso , Preservação de Sangue , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
6.
Analyst ; 141(11): 3319-27, 2016 May 23.
Artigo em Inglês | MEDLINE | ID: mdl-27109313

RESUMO

Individual units of donated red blood cells (RBCs) do not ordinarily undergo analytical testing prior to transfusion. This study establishes the utility of Raman spectroscopy for analyzing the biochemistry of stored RBC supernatant and reveals interesting storage-related changes about the accumulation of lactate, a chemical species that may be harmful to certain patients. The data show measurable variations in supernatant composition and demonstrate that some units of donated RBCs accumulate lactate much more readily than others. The spectra also indicate a higher relative concentration of lactate in units collected from male donors than female donors (p = 0.004) and imply that there is a greater degree of variability at later stages of storage in units from older male donors (>45 years). The study proves that Raman analysis has promise for elucidating the relationship between the metabolism of stored RBCs and donor characteristics. It also suggests that there may be benefit in developing a Raman instrument for the rapid non-invasive assessment of blood-bag biochemistry by measuring through plastic over-layers.


Assuntos
Preservação de Sangue , Eritrócitos/química , Ácido Láctico/sangue , Análise Espectral Raman , Adulto , Idoso , Transfusão de Sangue , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem
7.
Anal Chem ; 87(21): 10762-9, 2015 Nov 03.
Artigo em Inglês | MEDLINE | ID: mdl-26438999

RESUMO

Continued advances toward cell-based therapies for human disease generate a growing need for unbiased and label-free monitoring of cellular characteristics. We used Raman microspectroscopy to characterize four important stages in the 26-day directed differentiation of human embryonic stem cells (hESCs) to insulin-positive cells. The extent to which the cells retained spectroscopic features of pluripotent cells or developed spectroscopic features suggestive of pancreatic endocrine cells, as well as assessing the homogeneity of the cell populations at these developmental stages, were of particular interest. Such information could have implications for the utility of Raman microspectroscopy process analysis for the generation of insulin-positive cells from hESCs. Because hESC seeding density influences the subsequent pancreatic development, three different seeding density cultures were analyzed. Transcription factor and other marker analyses assessed the progress of the cells through the relevant developmental stages. Increases in the Raman protein-to-nucleic acid band ratios were observed at the final endocrine stage analyzed, but this increase was less than expected. Also, high glycogen band intensities, somewhat unexpected in pancreatic endocrine cells, suggested the presence of a substantial number of glycogen containing cells. We discuss the potential process analytical technology application of these findings and their importance for cell manufacturing.


Assuntos
Técnicas de Cultura de Células/instrumentação , Diferenciação Celular , Células Secretoras de Insulina/citologia , Pâncreas/citologia , Análise Espectral Raman , Células-Tronco Embrionárias/citologia , Glicogênio/análise , Humanos , Insulina/metabolismo , Células Secretoras de Insulina/metabolismo
8.
Anal Chem ; 86(19): 9399-404, 2014 Oct 07.
Artigo em Inglês | MEDLINE | ID: mdl-25196498

RESUMO

Crystalline silicon, widely used in the electronic industry, is also a very popular material for calibrating Raman spectrometry instruments. Silicon chips cut or cleaved from commercially available silicon wafers are low-cost monolithic monocrystalline materials that give a strong Raman line at 521 cm(-1) with almost no background. Such chips have at least one optically flat surface and can be used in place of glass microscope slides as sample substrates that provide an internal calibration standard during Raman measurements. The Raman signal intensity from the silicon can be selectively attenuated by depositing a gold layer on top of the silicon surface with variable thickness such that the far-field silicon Raman signal is comparable with the Raman signal of an investigated material adjacent to this structure. This gold layer provides the additional advantage of increased sensitivity of the spectral signal from the sample due to the reflectivity of the gold surface, which allows forward and backscattered analyte Raman excitation and signal collection. An additional thin encapsulating overlayer of SiO2 provides a protective and biocompatible surface to facilitate Raman microspectroscopic investigation of live cells.

9.
Anal Chem ; 85(19): 8996-9002, 2013 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-23968373

RESUMO

The cell cycle is a series of integrated and coordinated physiological events that results in cell growth and replication. Besides observing the event of cell division it is not feasible to determine the cell cycle phase without fatal and/or perturbing invasive procedures such as cell staining, fixing, and/or dissociation. Raman microspectroscopy (RMS) is a chemical imaging technique that exploits molecular vibrations as a contrast mechanism; it can be applied to single living cells noninvasively to allow unperturbed analysis over time. We used RMS to determine the cell cycle phase based on integrating the composite 783 cm(-1) nucleic acid band intensities across individual cell nuclei. After correcting for RNA contributions using the RNA 811 cm(-1) band, the measured intensities essentially reflected DNA content. When quantifying Raman images from single cells in a population of methanol-fixed human embryonic stem cells, the histogram of corrected 783 cm(-1) band intensities exhibited a profile analogous to that obtained using flow-cytometry with nuclear stains. The two population peaks in the histogram occur at Raman intensities corresponding to a 1-fold and 2-fold diploid DNA complement per cell, consistent with a distribution of cells with a population peak due to cells at the end of G1 phase (1-fold) and a peak due to cells entering M phase (2-fold). When treated with EdU to label the replicating DNA and block cell division, cells with higher EdU-related fluorescence generally had higher integrated Raman intensities. This provides proof-of-principle of an analytical method for label-free RMS determination in situ of cell cycle phase in adherent monolayers or even single adherent cells.


Assuntos
Ciclo Celular , Células-Tronco Embrionárias/citologia , Divisão Celular , Linhagem Celular , Humanos , Análise Espectral Raman
10.
Analyst ; 138(12): 3416-23, 2013 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-23636076

RESUMO

The nucleolus is a prominent subnuclear structure whose major function is the transcription and assembly of ribosome subunits. The size of the nucleolus varies with the cell cycle, proliferation rate and stress. Changes in nucleolar size, number, chemical composition, and shape can be used to characterize malignant cells. We used spontaneous Raman microscopy as a label-free technique to examine nucleolar spatial and chemical features. Raman images of the 1003 cm(-1) phenylalanine band revealed large, well-defined subnuclear protein structures in MFC-7 breast cancer cells. The 783 cm(-1) images showed that nucleic acids were similarly distributed, but varied more in intensity, forming observable high-intensity regions. High subnuclear RNA concentrations were observed within some of these regions as shown by 809 cm(-1) Raman band images. Principal component analyses of sub-images and library spectra validated the subnuclear presence of RNA. They also revealed that an actin-like protein covaried with DNA within the nucleolus, a combination that accounted for 64% or more of the spectral variance. Embryonic stem cells are another rapidly proliferating cell type, but their nucleoli were not as large or well defined. Estimating the size of the larger MCF-7 nucleolus was used to show the utility of Raman microscopy for morphometric analyses. It was concluded that imaging based on Raman microscopy provides a promising new method for the study of nucleolar function and organization, in the evaluation of drug and experimental effects on the nucleolus, and in clinical diagnostics and prognostics.


Assuntos
Nucléolo Celular/metabolismo , Microscopia/métodos , Imagem Molecular/métodos , Análise Espectral Raman , Proliferação de Células , Células-Tronco Embrionárias/citologia , Análise de Componente Principal , RNA/metabolismo
11.
Appl Spectrosc ; 77(8): 835-847, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36238996

RESUMO

Two-dimensional correlation spectroscopy (2D-COS) is a technique that permits the examination of synchronous and asynchronous changes present in hyperspectral data. It produces two-dimensional correlation coefficient maps that represent the mutually correlated changes occurring at all Raman wavenumbers during an implemented perturbation. To focus our analysis on clusters of wavenumbers that tend to change together, we apply a k-means clustering to the wavenumber profiles in the perturbation domain decomposition of the two-dimensional correlation coefficient map. These profiles (or trends) reflect peak intensity changes as a function of the perturbation. We then plot the co-occurrences of cluster members two-dimensionally in a manner analogous to a two-dimensional correlation coefficient map. Because wavenumber profiles are clustered based on their similarity, two-dimensional cluster member spectra reveal which Raman peaks change in a similar manner, rather than how much they are correlated. Furthermore, clustering produces a discrete partitioning of the wavenumbers, thus a two-dimensional cluster member spectrum exhibits a discrete presentation of related Raman peaks as opposed to the more continuous representations in a two-dimensional correlation coefficient map. We demonstrate first the basic principles of the technique with the aid of synthetic data. We then apply it to Raman spectra obtained from a polystyrene perchlorate model system followed by Raman spectra from mammalian cells fixed with different percentages of methanol. Both data sets were designed to produce differential changes in sample components. In both cases, all the peaks pertaining to a given component should then change in a similar manner. We observed that component-based profile clustering did occur for polystyrene and perchlorate in the model system and lipids, nucleic acids, and proteins in the mammalian cell example. This confirmed that the method can translate to "real world" samples. We contrast these results with two-dimensional correlation spectroscopy results. To supplement interpretation, we present the cluster-segmented mean spectrum of the hyperspectral data. Overall, this technique is expected to be a valuable adjunct to two-dimensional correlation spectroscopy to further facilitate hyperspectral data interpretation and analysis.


Assuntos
Percloratos , Poliestirenos , Análise Espectral Raman/métodos , Análise por Conglomerados
12.
Appl Spectrosc ; 77(8): 957-969, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37254554

RESUMO

Spectroscopic peak parameters are important since they provide information about the analyte under study. Besides obtaining these parameters, peak fitting also resolves overlapped peaks. Thus, the obtained parameters should permit the construction of a higher-resolution version of the original spectrum. However, peak fitting is not an easy task due to computational reasons and because the true nature of the analyte is often unknown. These difficulties are major impediments when large hyperspectral data sets need to be processed rapidly, such as for manufacturing process control. We have developed a novel and relatively fast two-part algorithm to perform peak fitting and resolution enhancement on such data sets. In the first part of the algorithm, estimates of the total number of bands and their parameters were obtained from a representative spectrum in the data set, using a combination of techniques. Starting with these parameter estimates, all the spectra were then iteratively and rapidly fitted with Gaussian bands, exploiting intrinsic features of the Gaussian distribution with vector operations. The best fits for each spectrum were retained. By reducing the obtained bandwidths and commensurately increasing their amplitudes, high-resolution spectra were constructed that greatly improved correlation-based analyses. We tested the performance of the algorithm on synthetic spectra to confirm that this method could recover the ground truth correlations between highly overlapped peaks. To assess effective peak resolution, the method was applied to low-resolution spectra of glucose and compared to results from high-resolution spectra. We then processed a larger spectral data set from mammalian cells, fixed with methanol or air drying, to demonstrate the resolution enhancement of the algorithm on complex spectra and the effects of resolution-enhanced spectra on two-dimensional correlation spectroscopy and principal component analyses. The results indicated that the algorithm would allow users to obtain high-resolution spectra relatively fast and permit the recovery of important aspects of the data's intrinsic correlation structure.

13.
Analyst ; 137(19): 4509-15, 2012 Oct 07.
Artigo em Inglês | MEDLINE | ID: mdl-22888493

RESUMO

Raman microspectroscopy is a non-destructive, label-free optical technique that offers information-rich molecular analysis of living cells. We report here the first Raman spectral study of human induced pluripotent stem cells (hiPSCs), and compare their Raman features to those of human embryonic stem cells (hESCs) and differentiated progeny of hESCs. Raman spectra from 687 cm(-1) to 1073 cm(-1) were collected from living hiPSCs, hESCs and hESCs non-specifically differentiated for 20 days. Spectra of hiPSCs and hESCs were found to be highly similar, and both were distinguishable from differentiated hESCs in terms of relative Raman peak intensities and variances. Principal component analysis (PCA) of the spectra demonstrated a clear discrimination between hiPSCs and differentiated hESCs. These results suggested that reprogramming returned human somatic cells to a state where the overall cellular composition was similar to that of human embryonic stem cells. Some metabolic differences between the two groups of pluripotent cells could be inferred, however it was unclear whether or not these differences were related to reprogramming.


Assuntos
Células-Tronco Embrionárias/citologia , Células-Tronco Pluripotentes Induzidas/citologia , Análise Espectral Raman , Diferenciação Celular , Linhagem Celular , Análise Discriminante , Humanos , Análise de Componente Principal
14.
Appl Spectrosc ; 76(1): 61-80, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34933587

RESUMO

Overlapping peaks in Raman spectra complicate the presentation, interpretation, and analyses of complex samples. This is particularly problematic for methods dependent on sparsity such as multivariate curve resolution and other spectral demixing as well as for two-dimensional correlation spectroscopy (2D-COS), multisource correlation analysis, and principal component analysis. Though software-based resolution enhancement methods can be used to counter such problems, their performances often differ, thereby rendering some more suitable than others for specific tasks. Furthermore, there is a need for automated methods to apply to large numbers of varied hyperspectral data sets containing multiple overlapping peaks, and thus methods ideally suitable for diverse tasks. To investigate these issues, we implemented three novel resolution enhancement methods based on pseudospectra, over-deconvolution, and peak fitting to evaluate them along with three extant methods: node narrowing, blind deconvolution, and the general-purpose peak fitting program Fityk. We first applied the methods to varied synthetic spectra, each consisting of nine overlapping Voigt profile peaks. Improved spectral resolution was evaluated based on several criteria including the separation of overlapping peaks and the preservation of true peak intensities in resolution-enhanced spectra. We then investigated the efficacy of these methods to improve the resolution of measured Raman spectra. High resolution spectra of glucose acquired with a narrow spectrometer slit were compared to ones using a wide slit that degraded the spectral resolution. We also determined the effects of the different resolution enhancement methods on 2D-COS and on chemical contrast image generation from mammalian cell spectra. We conclude with a discussion of the particular benefits, drawbacks, and potential of these methods. Our efforts provided insight into the need for effective resolution enhancement approaches, the feasibility of these methods for automation, the nature of the problems currently limiting their use, and in particular those aspects that need improvement.


Assuntos
Software , Análise Espectral Raman , Animais , Análise de Componente Principal
15.
Anal Chem ; 83(16): 6254-8, 2011 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-21702506

RESUMO

We present a method to perform absolute quantification of glycogen in human embryonic stem cells (hESCs) in situ based on the use of Raman microspectroscopy. The proposed quantification method was validated by comparison to a commonly used commercial glycogen assay kit. With Raman microspectroscopy, we could obtain the glycogen content of hESCs faster and apparently more accurately than with the kit. In addition, glycogen distributions across a colony could be obtained. Raman spectroscopy can provide reliable estimates of the in situ glycogen content in hESCs, and this approach should also be extensible to their other biochemical constituents as well as to other cell types.


Assuntos
Células-Tronco Embrionárias/química , Glicogênio/análise , Análise Espectral Raman/métodos , Células-Tronco Embrionárias/citologia , Humanos , Kit de Reagentes para Diagnóstico
16.
Appl Spectrosc ; 75(5): 520-530, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33231477

RESUMO

Here, we present an augmented form of two-dimensional correlation spectroscopy, that integrates in a single format data from spectroscopic and multiple non-spectroscopic sources for analysis. The integration is affected by augmenting every spectrum in a hyperspectral data set with relevant non-spectroscopic data to permit two-dimensional correlation analysis(2D-COS) of the ensemble of augmented spectra. A k-means clustering is then applied to the results of the perturbation domain decomposition to determine which Raman peaks cluster with any of the non-spectroscopic data. We introduce and explain the method with the aid of synthetic spectra and synthetic non-spectroscopic data. We then demonstrate this approach with data using Raman spectra from human embryonic stem cell aggregates undergoing directed differentiation toward pancreatic endocrine cells and parallel bioassays of hormone mRNA expression and C-peptide levels in spent medium. These pancreatic endocrine cells generally contain insulin or glucagon. Insulin has disulfide bonds that produce Raman scattering near 513 cm-1, but no tryptophan. For insulin-positive cells, we found that the application of multisource correlation analysis revealed a high correlation between insulin mRNA and Raman scattering in the disulfide region. In contrast, glucagon has no disulfide bonds but does contain tryptophan. For glucagon-positive cells, we also observed a high correlation between glucagon mRNA and tryptophan Raman scattering (∼757 cm-1). We conclude with a discussion of methods to enhance spectral resolution and its effects on the performance of multisource correlation analysis.


Assuntos
Glucagon , Análise Espectral Raman , Humanos , Insulina
17.
Anal Chem ; 82(12): 5020-7, 2010 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-20481517

RESUMO

Raman microspectroscopy is an attractive approach for chemical imaging of biological specimens, including live cells, without the need for chemi-selective stains. Using a microspectrometer, near-infrared Raman spectra throughout the range 663 cm(-1) to 1220 cm(-1) were obtained from colonies of CA1 human embryonic stem cells (hESCs) and CA1 cells that had been stimulated to differentiate for 3 weeks by 10% fetal bovine serum on gelatin. Distributions and intensities of spectral bands attributed to proteins varied significantly between undifferentiated and differentiated cells. Importantly, compared to proteins and lipids, the band intensities of nucleic acids were dominant in undifferentiated cells with a dominance-reversal in differentiated cells. Thus, we could identify intensity ratios of particular protein-related bands (e.g., 757 cm(-1) tryptophan) to nucleic acid bands (784 cm(-1) DNA/RNA composite) that were effective in discriminating between spectra of undifferentiated and differentiated cells. We observed no discernible negative effects due to the laser exposure in terms of morphology, proliferation, or pluripotency of the stem cells. We conclude that Raman microscopy and complementary data processing procedures provide a rapid, noninvasive approach that can distinguish hESCs from differentiated cells. This is the first report to identify specific Raman markers for the differentiation status of hESCs.


Assuntos
Diferenciação Celular , Células-Tronco Embrionárias/citologia , Microscopia/métodos , Análise Espectral Raman/métodos , Animais , Bovinos , Células-Tronco Embrionárias/metabolismo , Gelatina/metabolismo , Humanos , Soroalbumina Bovina/metabolismo
18.
Appl Spectrosc ; 73(1): 47-58, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30063385

RESUMO

Theoretical probability distributions are often fitted to the individual peaks of Raman spectra to decompose them and facilitate further analyses. Fitting has the additional advantage of eliminating noise. We have exploited this noise-eliminating attribute of fitting procedures in an automated algorithm to smooth Raman spectra. An initial smoothing was performed by fitting Voigt distributions to every channel in a spectrum. The Voigt distribution characters used were strongly Gaussian, the distribution widths equal to the spectral resolution, and their initial amplitudes equal to the spectral intensities at the channels where they were located. The smoothed spectrum was then subtracted from the original noisy spectrum to obtain a residual. For channels where the residual exceeded a limit-of-detection threshold, the distribution width was decreased. The fitting was then repeated until a secondary, lower limit distribution width was reached. The residual was then smoothed repeatedly in the same manner until the minimum distribution width was reached. After each repetition, the smoothed residual was added to the smoothed spectrum. The process was continued until a combined limit of detection and chi-squared stopping criterion was reached. Although slower in comparison to spline- and Savitzky-Golay-based methods, the smoothing quality was significantly better allowing the majority of smoothed spectra, in contrast to these methods, to pass a stringent smoothing quality test.

19.
Appl Spectrosc ; 62(8): 847-53, 2008 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-18702856

RESUMO

When reconstructing a measured spectrum to enhance its signal-to-noise ratio (SNR), the objective is to minimize the variance between the smooth reconstructed spectrum and the original measured spectrum, hence to attain an acceptably small chi2 value. The chi2 value thus measures the fidelity of the reconstruction to the original. Smoothness can be conceived as attenuated variation between adjacent points in a spectrum. Thus, a conceptual change in the application of the chi2 function to the difference between adjacent points of the reconstructed spectrum permits its use, in principle, as both a measure of smoothness and a measure of fidelity. We show here that implementations of this concept produce results superior to Savitzky-Golay filters.

20.
Appl Spectrosc ; 62(10): 1160-6, 2008 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-18926027

RESUMO

The automated processing of data from high-throughput and real-time collection procedures is becoming a pressing problem. Currently the focus is shifting to automated smoothing techniques where, unlike background subtraction techniques, very few methods exist. We have developed a filter based on the widely used and conceptually simple moving average method or zero-order Savitzky-Golay filter and its iterative relative, the Kolmogorov-Zurbenko filter. A crucial difference, however, between these filters and our implementation is that our fully automated smoothing filter requires no parameter specification or parameter optimization. Results are comparable to, or better than, Savitzky-Golay filters with optimized parameters and superior to the automated iterative median filter. Our approach, because it is based on the highly familiar moving average concept, is intuitive, fast, and straightforward to implement and should therefore be of immediate and considerable practical use in a wide variety of spectroscopy applications.


Assuntos
Algoritmos , Robótica/métodos , Processamento de Sinais Assistido por Computador , Análise Espectral/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA