Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 43
Filtrar
1.
BMC Musculoskelet Disord ; 24(1): 51, 2023 Jan 21.
Artigo em Inglês | MEDLINE | ID: mdl-36670400

RESUMO

BACKGROUND: The majority of knee endoprostheses are cemented. In an earlier study the effects of different cementing techniques on cement penetration were evaluated using a Sawbone model. In this study we used a human cadaver model to study the effect of different cementing techniques on relative motion between the implant and the femoral shaft component under dynamic loading. METHODS: Two different cementing techniques were tested in a group of 15 pairs of human fresh frozen legs. In one group a conventional cementation technique was used and, in another group, cementation was done using a pressurizing technique. Under dynamic loading that simulated real life conditions relative motion at the bone-implant interface were studied at 20 degrees and 50 degrees flexion. RESULTS: In both scenarios, the relative motion anterior was significantly increased by pressure application. Distally, it was the same with higher loads. No significant difference could be measured posteriorly at 20°. At 50° flexion, however, pressurization reduced the posterior relative motion significantly at each load level. CONCLUSION: The use of the pressurizer does not improve the overall fixation compared to an adequate manual cement application. The change depends on the loading, flexion angle and varies in its proportion in between the interface zones.


Assuntos
Artroplastia do Joelho , Humanos , Artroplastia do Joelho/métodos , Fêmur/cirurgia , Articulação do Joelho/cirurgia , Cimentos Ósseos , Próteses e Implantes
2.
Sensors (Basel) ; 23(6)2023 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-36991953

RESUMO

When overmoulding optoelectronic devices with optical elements, precise alignment of the overmoulded part and the mould is of great importance. However, mould-integrated positioning sensors and actuators are not yet available as standard components. As a solution, we present a mould-integrated optical coherence tomography (OCT) device that is combined with a piezo-driven mechatronic actuator, which is capable of performing the necessary displacement correction. Because of the complex geometric structure optoelectronic devices may have, a 3D imaging method was preferable, so OCT was chosen. It is shown that the overall concept leads to sufficient alignment accuracy and, apart from compensating for the in-plane position error, provides valuable additional information about the sample both before and after the injection process. The increased alignment accuracy leads to better energy efficiency, improved overall performance and less scrap parts, and thus even a zero-waste production process might be feasible.

3.
Nat Mater ; 20(10): 1407-1413, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34112978

RESUMO

Blending organic molecules to tune their energy levels is currently being investigated as an approach to engineer the bulk and interfacial optoelectronic properties of organic semiconductors. It has been proven that the ionization energy and electron affinity can be equally shifted in the same direction by electrostatic effects controlled by blending similar halogenated derivatives with different energetics. Here we show that the energy gap of organic semiconductors can also be tuned by blending. We use oligothiophenes with different numbers of thiophene rings as an example and investigate their structure and electronic properties. Photoelectron spectroscopy and inverse photoelectron spectroscopy show tunability of the single-particle gap, with the optical gaps showing similar, but smaller, effects. Theoretical analysis shows that this tuning is mainly caused by a change in the dielectric constant with blend ratio. Further studies will explore the practical impact of this energy-level engineering strategy for optoelectronic devices.

4.
Arch Phys Med Rehabil ; 103(9): 1699-1706, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35288097

RESUMO

OBJECTIVE: To investigate the relationship of frontal plane ankle mobility with the effects of an ankle-foot orthosis (AFO) and a laterally wedged insole (LWI) on knee adduction moment (KAM) in the treatment of medial knee osteoarthritis. DESIGN: Randomized, nonblinded crossover trial. SETTING: Outpatient clinic of university hospital. PARTICIPANTS: Referred sample of 20 patients (N=20) with medial knee osteoarthritis stage 1-3 (Kellgren and Lawrence), aged 56.4±6.5 years; 58 patients were assessed, 21 were included, and 1 was a dropout. There were 14 healthy reference participants without knee osteoarthritis (convenience sample) who were matched by age. INTERVENTIONS: Patients received AFO and LWI for 6 weeks each with gait analysis after each 6-week intervention. Patients underwent additional barefoot gait analysis, walking on even ground and on a cross slope of 5° lateral elevation and standing on inclinations of 0°, 5°, 10°, and 20°. MAIN OUTCOME MEASURES: Spearman correlation between the immediate change in first peak of KAM with each aid and the change in hindfoot varus on the cross slope relative to level ground. RESULTS: The KAM reduction with AFO correlated significantly with hindfoot varus reaction to the cross slope during walking: the greater the hindfoot valgization on the cross slope, the greater the KAM reduction with AFO (Spearman ρ=0.53, P=.02). The KAM reduction with LWI correlated moderately negatively with the change in hindfoot varus: the greater the hindfoot valgization on the cross slope, the smaller the KAM reduction with LWI (r=-0.31 P=.18). CONCLUSIONS: LWI may be suitable for patients with limited to normal frontal plane ankle mobility. Patients with greater frontal plane ankle mobility benefit most from frontal plane ankle bridging with AFO. Studies with larger samples are necessary.


Assuntos
Órtoses do Pé , Osteoartrite do Joelho , Tornozelo , Fenômenos Biomecânicos , Marcha , Humanos , Articulação do Joelho , Osteoartrite do Joelho/terapia , Sapatos
5.
Clin Rehabil ; 35(7): 1032-1043, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33781101

RESUMO

OBJECTIVE: To compare biomechanical and clinical outcome of laterally wedged insoles (LWI) and an ankle-foot orthosis (AFO) in patients with medial knee osteoarthritis. DESIGN: Single-centre, block-randomized, cross-over controlled trial. SETTING: Outpatient clinic. SUBJECTS: About 39 patients with symptomatic medial knee osteoarthritis. INTERVENTIONS: Patients started with either LWI or AFO, determined randomly, and six weeks later changed to the alternative. MAIN MEASURES: Change in the 1st maximum of external knee adduction moment (eKAM) was assessed with gait analysis. Additional outcomes were other kinetic and kinematic changes and the patient-reported outcomes EQ-5D-5L, Oxford Knee Score (OKS), American Knee Society Clinical Rating System (AKSS), Hannover Functional Ability Questionnaire - Osteoarthritis and knee pain. RESULTS: Mean age (SD) of the study population was 58 (8) years, mean BMI 30 (5). Both aids significantly improved OKS (LWI P = 0.003, AFO P = 0.001), AKSS Knee Score (LWI P = 0.01, AFO P = 0.004) and EQ-5D-5L Index (LWI P = 0.001, AFO P = 0.002). AFO reduced the 1st maximum of eKAM by 18% (P < 0.001). The LWI reduced both maxima by 6% (P = 0.02, P = 0.03). Both AFO and LWI reduced the knee adduction angular impulse (KAAI) by 11% (P < 0.001) and 5% (P = 0.05) respectively. The eKAM (1st maximum) and KAAI reduction was significantly larger with AFO than with LWI (P = 0.001, P = 0.004). CONCLUSIONS: AFO reduces medial knee load more than LWI. Nevertheless, no clinical superiority of either of the two aids could be shown.


Assuntos
Órtoses do Pé , Osteoartrite do Joelho/reabilitação , Estudos Cross-Over , Desenho de Equipamento , Feminino , Análise da Marcha , Humanos , Masculino , Pessoa de Meia-Idade , Medidas de Resultados Relatados pelo Paciente
6.
Internist (Berl) ; 62(9): 921-927, 2021 Sep.
Artigo em Alemão | MEDLINE | ID: mdl-34328522

RESUMO

Intervertebral disc-related diseases of the cervical and lumbar spine are considered to be occupational diseases, if the occupational and medical prerequisites are fulfilled and the causal connection between the prerequisites is likely. The working conditions include occupational burdens with long-term lifting and carrying of heavy loads or long-term activities in an extremely bent position of the torso, long-term carrying of heavy loads on the shoulders and long-term effects of whole-body vibration in a sitting position. A medical prerequisite is fulfilled by a damage pattern with chronic lower back or neck pain and damage of the cervical or lumbar vertebrae in a conform manner.In the legal assessment the occupational conditions are examined by the preventive services of the statutory accident insurance and the medical conditions by the medical expert. Furthermore, the medical expert examines the causal connection between the fulfilled prerequisites, whereby the temporal connection (reaching the minimum load dose before realization of the conform damage pattern) and by exclusion of other competing factors are essential. As of 1 January 2021 the necessity to quit the burdening occupation has been omitted by law.


Assuntos
Degeneração do Disco Intervertebral , Deslocamento do Disco Intervertebral , Disco Intervertebral , Doenças Profissionais , Vértebras Cervicais , Humanos , Degeneração do Disco Intervertebral/diagnóstico , Deslocamento do Disco Intervertebral/diagnóstico , Doenças Profissionais/diagnóstico , Doenças Profissionais/etiologia
7.
Nat Mater ; 18(3): 242-248, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30692647

RESUMO

Doped organic semiconductors typically exhibit a thermal activation of their electrical conductivity, whose physical origin is still under scientific debate. In this study, we disclose relationships between molecular parameters and the thermal activation energy (EA) of the conductivity, revealing that charge transport is controlled by the properties of host-dopant integer charge transfer complexes (ICTCs) in efficiently doped organic semiconductors. At low doping concentrations, charge transport is limited by the Coulomb binding energy of ICTCs, which can be minimized by systematic modification of the charge distribution on the individual ions. The investigation of a wide variety of material systems reveals that static energetic disorder induced by ICTC dipole moments sets a general lower limit for EA at large doping concentrations. The impact of disorder can be reduced by adjusting the ICTC density and the intramolecular relaxation energy of host ions, allowing an increase of conductivity by many orders of magnitude.

8.
Schmerz ; 34(4): 357-368, 2020 08.
Artigo em Alemão | MEDLINE | ID: mdl-32415380

RESUMO

Pain caused by the sacroiliac joint (SIG) makes up a relevant proportion of lumbar back pain and can have a variety of specific and non-specific causes. The SIG represents the central link between the spine and the lower extremity. It is characterized by high stability and low mobility. There are significant inter-individual differences. In addition to the possibility of asymptomatic situations, SIG dysfunction can trigger pain in the lower back with possible radiation to the lower extremity. In addition to a structured medical history, clinical examination requires an examination of the adjacent joints and the neurological status. More specifically, movement and provocation tests as well as infiltrations are carried out. General information and conservative therapeutic methods represent the first-line therapies. Interventional and surgical procedures can help in the case of chronification.


Assuntos
Dor Lombar , Articulação Sacroilíaca , Humanos , Dor Lombar/etiologia , Medição da Dor , Exame Físico , Articulação Sacroilíaca/fisiopatologia
9.
Artigo em Alemão | MEDLINE | ID: mdl-32189043

RESUMO

Diagnostic and therapeutic procedures are popular and frequently performed for low back pain. This narrative review presents and discusses the myths and evidence related to these procedures.In most cases it is nonspecific pain, for which no underlying disease can be named. Image diagnostics using X­rays and MRI are rarely helpful in the case of new nonspecific back pain.Evidence for chirotherapy is doubtful. Also, evidence is lacking for invasive and surgical procedures in local and regional low back pain. These procedures show superiority in radicular pain only: extraction of disc herniation in acute and subacute leg pain and segmental lumbar fusion in chronic leg pain. Nevertheless, these and other invasive methods are being used to an increasing extent. Spontaneous healing and the possibilities of the patient to become pain-relieving for themselves are neglected and increased risks are accepted.Therapeutic approaches fostering self-efficacy by reconditioning physical and mental capability and improving positive self-perception ("interdisciplinary multimodal pain therapy") effect superior and sustainable results in subacute and chronic nonspecific back pain. Patients and physicians, however, tend to prefer passive and invasive therapy strategies. The underlying mechanisms should be understood. New thinking is necessary.


Assuntos
Dor nas Costas/diagnóstico , Dor nas Costas/terapia , Diagnóstico por Imagem/métodos , Medição da Dor , Dor Crônica , Alemanha , Humanos
10.
Nat Mater ; 17(5): 439-444, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29483635

RESUMO

Doping plays a crucial role in semiconductor physics, with n-doping being controlled by the ionization energy of the impurity relative to the conduction band edge. In organic semiconductors, efficient doping is dominated by various effects that are currently not well understood. Here, we simulate and experimentally measure, with direct and inverse photoemission spectroscopy, the density of states and the Fermi level position of the prototypical materials C60 and zinc phthalocyanine n-doped with highly efficient benzimidazoline radicals (2-Cyc-DMBI). We study the role of doping-induced gap states, and, in particular, of the difference Δ1 between the electron affinity of the undoped material and the ionization potential of its doped counterpart. We show that this parameter is critical for the generation of free carriers and influences the conductivity of the doped films. Tuning of Δ1 may provide alternative strategies to optimize the electronic properties of organic semiconductors.

11.
J Clin Pharm Ther ; 44(4): 644-646, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-30968430

RESUMO

WHAT IS KNOWN AND OBJECTIVE: Gabapentin, a γ-aminobutyric acid derivative, is used for the treatment of partial onset seizures, postherpetic neuralgia, diabetic neuropathy and a host of other neurological disorders. CASE DESCRIPTION: A 44-year-old woman with spinal stenosis was prescribed gabapentin for pain. Two months after initiating therapy, she was diagnosed with a new-onset non-ischaemic cardiomyopathy with an ejection fraction of 36% measured on a transthoracic echocardiogram. WHAT IS NEW AND CONCLUSION: A patient with suspected gabapentin-induced cardiomyopathy is reported. However, to date, gabapentin therapy has not been associated with risk of the developing a cardiomyopathy.


Assuntos
Cardiomiopatias/induzido quimicamente , Gabapentina/efeitos adversos , Adulto , Feminino , Humanos , Ácido gama-Aminobutírico/efeitos adversos
12.
Psychother Psychosom Med Psychol ; 68(11): 470-474, 2018 Nov.
Artigo em Alemão | MEDLINE | ID: mdl-29933464

RESUMO

The orthopedic medical history of the now 56-year-old Mr. Z began immediately after his birth with an inpatient clubfoot therapy. With the onset of adolescence, multilocular pain began. The long-standing patient career was characterized by disappointment about the early onset and recurrent need for treatment. The disappointment motive is closely related to the relationship between the patient and his mother. The biography illustrates the intertwining of early (orthopedic) treatment, primary bonding and disease experiences. A multimodal pain therapy was able to target Mr. Z, create positive body experiences and finally reduce the pain.


Assuntos
Pé Torto Equinovaro/terapia , Manipulação Ortopédica , Pé Torto Equinovaro/complicações , Pé Torto Equinovaro/psicologia , Terapia Combinada , Humanos , Masculino , Pessoa de Meia-Idade , Dor/etiologia , Manejo da Dor/psicologia
13.
J Knee Surg ; 36(4): 417-423, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34507360

RESUMO

Cemented unicompartmental knee arthroplasty (UKA) shows good survivorship and function. However, implant failure, causing the need for revision, can occur. Aseptic loosening is still among the most common reasons for revision. The purpose of this study was to assess the influence of preimplantation lavage technique on tibial cement penetration depth, tibial cement volume, and load to fracture in the tibial component of mobile-bearing UKA. In 10 pairs of fresh frozen human tibiae, cemented UKA was implanted by an experienced surgeon. Tibial components were then implanted, left and right tibiae were randomly allocated to group A or B. Prior to implantation, irrigation was performed with either syringe lavage or pulsatile jet lavage in a standardized manner. Cement surface was 4170.2 mm2 (3271.6-5497.8 mm2) in the syringe lavage group, whereas the jet lavage group showed 4499.3 mm2 (3354.3-5809.1 mm2); cement volume was significantly higher as well (4143.4 mm3 (2956.6-6198.6 mm3) compared with 5936.9 mm3 (3077.5-8183.1 mm3)). Cement penetration depth was 2.5 mm (1.7-3.2 mm) for the jet lavage, and 1.8 mm (1.2-2.4 mm) for the syringe lavage. The mean fracture load was 4680 N in the jet lavage group and 3800 N in the syringe lavage group (p = 0.001). Subsidence was significantly higher for syringe lavage. This study suggests a correlation of cement penetration depth and cement volume to implant failure in the tibial component of a UKA using a cadaveric model. The type of bone lavage most likely influences these two key parameters.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Humanos , Artroplastia do Joelho/métodos , Cimentos Ósseos , Cadáver , Cimentação/métodos , Irrigação Terapêutica/métodos , Tíbia/cirurgia
14.
Orthopadie (Heidelb) ; 51(12): 1015-1021, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35802155

RESUMO

Treatment of femoral neck fractures secondary to osteopetrosis is an uncertain and puzzled decision. Experience in the treatment, especially in the pediatric population, is scarcely reported. The duration of conservative treatment is prolonged and poses the risks of non-union and development of coxa vara deformity. The recommended treatment is closed reduction and internal fixation; however, surgery on osteopetrotic bone is challenging due to defective bone marrow function, delayed consolidation and higher risk of intraoperative fractures. Slipped capital femoral epiphysis secondary to osteopetrosis is very rarely reported. This article presents the case of a 5-year-old female patient with rapidly deteriorating physical function due to bilateral proximal femoral Salter-Harris type II fractures with associated slippage of the growth plates secondary to confirmed autosomal recessive osteopetrosis. Operative treatment was performed in a tertiary level orthopedic center with closed reduction and internal fixation with cannulated screws. A loss of fixation with coxa vara deformity was seen on the left side 7 months postoperatively with increasing pain. A revision surgery with reosteosynthesis and a valgus osteotomy was thus performed which showed good subjective and objective results 1 year postoperatively with complete bony union.


Assuntos
Coxa Vara , Fraturas do Colo Femoral , Osteopetrose , Escorregamento das Epífises Proximais do Fêmur , Criança , Pré-Escolar , Feminino , Humanos , Coxa Vara/diagnóstico por imagem , Fraturas do Colo Femoral/diagnóstico por imagem , Fixação Interna de Fraturas/métodos , Osteopetrose/complicações , Escorregamento das Epífises Proximais do Fêmur/diagnóstico por imagem
15.
Bone Joint Res ; 11(4): 229-238, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35400170

RESUMO

AIMS: One of the main causes of tibial revision surgery for total knee arthroplasty is aseptic loosening. Therefore, stable fixation between the tibial component and the cement, and between the tibial component and the bone, is essential. A factor that could influence the implant stability is the implant design, with its different variations. In an existing implant system, the tibial component was modified by adding cement pockets. The aim of this experimental in vitro study was to investigate whether additional cement pockets on the underside of the tibial component could improve implant stability. The relative motion between implant and bone, the maximum pull-out force, the tibial cement mantle, and a possible path from the bone marrow to the metal-cement interface were determined. METHODS: A tibial component with (group S: Attune S+) and without (group A: Attune) additional cement pockets was implanted in 15 fresh-frozen human leg pairs. The relative motion was determined under dynamic loading (extension-flexion 20° to 50°, load-level 1,200 to 2,100 N) with subsequent determination of the maximum pull-out force. In addition, the cement mantle was analyzed radiologically for possible defects, the tibia base cement adhesion, and preoperative bone mineral density (BMD). RESULTS: The BMD showed no statistically significant difference between both groups. Group A showed for all load levels significantly higher maximum relative motion compared to group S for 20° and 50° flexion. Group S improved the maximum failure load significantly compared to group A without additional cement pockets. Group S showed a significantly increased cement adhesion compared to group A. The cement penetration and cement mantle defect analysis showed no significant differences between both groups. CONCLUSION: From a biomechanical point of view, the additional cement pockets of the component have improved the fixation performance of the implant. Cite this article: Bone Joint Res 2022;11(4):229-238.

16.
J Rehabil Med ; 54: jrm00324, 2022 Sep 22.
Artigo em Inglês | MEDLINE | ID: mdl-35929765

RESUMO

OBJECTIVE: To investigate the impact of varus malalignment of the knee on pain reduction achieved by an ankle-foot orthosis and a laterally wedged insole in patients with medial knee osteoarthritis. DESIGN: Secondary analysis of a randomized, clinically prospective cross-over study. PATIENTS: Twenty-eight participants with medial knee osteoarthritis. METHODS: All participants wore a 5-mm laterally wedged insole and an ankle-foot orthosis for a period of 6 weeks each in a randomized order. Pain was reported on a numerical rating scale and was correlated with limb alignment, as defined by the mechanical axis deviation in full-leg standing radiographs. RESULTS: Insole and orthosis use reduced pain compared with baseline (median knee pain change: insole -0.5 (-5 to +6), orthosis -1.5 (-7 to +5). A higher mechanical axis deviation (greater varus) correlated significantly with smaller pain reduction for both aids (insole p = 0.003, orthosis p < 0.001). A cut-off to predict pain response was found at a mechanical axis deviation of 14-15 mm for both aids, i.e. > 3° knee varus. CONCLUSION: There is a correlation between varus malalignment and pain reduction. There seems to be a mechanical axis deviation cut-off that predicts the response to treatment with the aids with good sensitivity.


Assuntos
Órtoses do Pé , Osteoartrite do Joelho , Dor , Tornozelo , Estudos Cross-Over , Humanos , Osteoartrite do Joelho/complicações , Osteoartrite do Joelho/terapia , Dor/etiologia , Dor/prevenção & controle , Estudos Prospectivos
17.
Bone Joint Res ; 11(2): 82-90, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35124977

RESUMO

AIMS: The cemented Oxford unicompartmental knee arthroplasty (OUKA) features two variants: single and twin peg OUKA. The purpose of this study was to assess the stability of both variants in a worst-case scenario of bone defects and suboptimal cementation. METHODS: Single and twin pegs were implanted randomly allocated in 12 pairs of human fresh-frozen femora. We generated 5° bone defects at the posterior condyle. Relative movement was simulated using a servohydraulic pulser, and analyzed at 70°/115° knee flexion. Relative movement was surveyed at seven points of measurement on implant and bone, using an optic system. RESULTS: At the main fixation zone, the twin peg shows less relative movement at 70°/115°. At the transition zone, relative movements are smaller for the single peg for both angles. The single peg shows higher compression at 70° flexion, whereas the twin peg design shows higher compression at 115°. X-displacement is significantly higher for the single peg at 115°. CONCLUSION: Bony defects should be avoided in OUKA. The twin peg shows high resilience against push-out force and should be preferred over the single peg. Cite this article: Bone Joint Res 2022;11(2):82-90.

18.
Knee ; 30: 170-175, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33933907

RESUMO

BACKGROUND: Total knee arthroplasty is a very successful standard treatment for severe osteoarthritis. Nevertheless, the literature reports tibial debonding between implant and bone cement as well as radiolucent lines related to the tibial components of different knee systems. Regardless of cementing techniques and the influences during surgery, we examined the design of a newly developed knee system and its predecessors (Attune, Attune S+, P.F.C. Sigma, P.F.C. Sigma RP/M.B.T., all DePuy). METHODS: We investigated the dimensions of the tibial components and the fit between them and their bone bed after instrumentation in a foam material. RESULTS: Our results showed considerable differences for the used knee prostheses as well as their tibial instrumentation options with a corresponding risk for incomplete seating. CONCLUSION: The orthopedic surgeons need to be aware of these design features and the resulting increased seating resistance especially in hard and sclerotic bone. ARTICLE FOCUS: Comparison of the tibial instruments and the different design options of the Attune knee system and its predecessor knee prostheses. KEY MESSAGES: The Attune implant showed incomplete seating because of too much press fit and an uneven bone quality or sclerosis can result in tilting of the tibial component. STRENGTHS AND LIMITATIONS: This is the first study investigating the Attune knee and its predecessor in terms of implant seating and press fit. The foam material is a limitation.


Assuntos
Artroplastia do Joelho/instrumentação , Cimentos Ósseos , Prótese do Joelho , Tíbia , Artroplastia do Joelho/efeitos adversos , Artroplastia do Joelho/métodos , Humanos , Articulação do Joelho/cirurgia , Desenho de Prótese , Tíbia/anatomia & histologia , Tíbia/cirurgia
19.
Knee ; 33: 185-192, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34638017

RESUMO

BACKGROUND: Aseptic loosening remains one of the most common causes of revision of the tibial component for total knee arthroplasty. A stable bond between implant and cement is essential for appropriate long-term results. The aim of our in vitro study was to investigate the maximum failure load of tibial ATTUNE prosthesis design alternatives compared with a previous design. In addition, cement-in-cement revision was considered as a potential strategy after tibial component debonding. METHODS: The experimental investigations of the maximum failure load of the implant-cement interface were performed under optimal conditions, without potential contamination. We compared the designs of the tibial components of the ATTUNE, ATTUNE S+ and P.F.C. Sigma. In addition, we investigated the cement-in-cement revision for the ATTUNE knee system replacing it with an ATTUNE S+. RESULTS: The maximum failure load showed no significant difference between P.F.C. Sigma and ATTUNE groups (P = 0.087), but there was a significant difference between the P.F.C. Sigma and the ATTUNE S+ groups (P < 0.001). The analysis also showed a significant difference (P < 0.001) between the ATTUNE and the ATTUNE S+ groups for the maximum failure load. The ATTUNE S+ cement-in-cement revision group showed a significant higher failure load (P < 0.001) compared with the P.F.C. Sigma and ATTUNE groups. No significant differences (P = 1.000) were found between the ATTUNE S+ cement-in-cement and ATTUNE S+ group. CONCLUSION: Based on these results, we found no design-specific evidence of increased debonding risk with the ATTUNE and ATTUNE S+ components compared with the P.F.C Sigma. Furthermore, the cement-in-cement revision seems to be an alternative for the revision surgery.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Cimentos Ósseos , Humanos , Articulação do Joelho/cirurgia , Desenho de Prótese , Falha de Prótese , Reoperação , Tíbia/cirurgia
20.
Z Orthop Unfall ; 158(5): 517-523, 2020 Oct.
Artigo em Inglês, Alemão | MEDLINE | ID: mdl-31634955

RESUMO

Due to its high prevalence und sometimes serious medical consequences, osteoporosis is of highest socio-economic importance. Medical experts are confronted with it in a wide variety of fields of law. In order to be able to correctly classify the disease in the respective legal framework, current knowledge about it is required. Important classifications as well as scientifically determined findings on fractures and fracture healing are in the foreground. This knowledge can be used to answer questions concerning prevention, reduced earning capacity, incapacity for work, context assessments or restrictions according to the social compensation law or the severely disabled law.


Assuntos
Pessoas com Deficiência , Osteoporose , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA