Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Eur Heart J ; 38(9): 648-660, 2017 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-28025189

RESUMO

AIMS: Cardiopoietic cells, produced through cardiogenic conditioning of patients' mesenchymal stem cells, have shown preliminary efficacy. The Congestive Heart Failure Cardiopoietic Regenerative Therapy (CHART-1) trial aimed to validate cardiopoiesis-based biotherapy in a larger heart failure cohort. METHODS AND RESULTS: This multinational, randomized, double-blind, sham-controlled study was conducted in 39 hospitals. Patients with symptomatic ischaemic heart failure on guideline-directed therapy (n = 484) were screened; n = 348 underwent bone marrow harvest and mesenchymal stem cell expansion. Those achieving > 24 million mesenchymal stem cells (n = 315) were randomized to cardiopoietic cells delivered endomyocardially with a retention-enhanced catheter (n = 157) or sham procedure (n = 158). Procedures were performed as randomized in 271 patients (n = 120 cardiopoietic cells, n = 151 sham). The primary efficacy endpoint was a Finkelstein-Schoenfeld hierarchical composite (all-cause mortality, worsening heart failure, Minnesota Living with Heart Failure Questionnaire score, 6-min walk distance, left ventricular end-systolic volume, and ejection fraction) at 39 weeks. The primary outcome was neutral (Mann-Whitney estimator 0.54, 95% confidence interval [CI] 0.47-0.61 [value > 0.5 favours cell treatment], P = 0.27). Exploratory analyses suggested a benefit of cell treatment on the primary composite in patients with baseline left ventricular end-diastolic volume 200-370 mL (60% of patients) (Mann-Whitney estimator 0.61, 95% CI 0.52-0.70, P = 0.015). No difference was observed in serious adverse events. One (0.9%) cardiopoietic cell patient and 9 (5.4%) sham patients experienced aborted or sudden cardiac death. CONCLUSION: The primary endpoint was neutral, with safety demonstrated across the cohort. Further evaluation of cardiopoietic cell therapy in patients with elevated end-diastolic volume is warranted.


Assuntos
Insuficiência Cardíaca/terapia , Transplante de Células-Tronco Mesenquimais/métodos , Isquemia Miocárdica/terapia , Adulto , Idoso , Método Duplo-Cego , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Resultado do Tratamento , Adulto Jovem
2.
J Mater Sci Mater Med ; 24(12): 2729-39, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23904056

RESUMO

Drug-eluting stents have been developed to reduce the risk of restenosis after angioplasty. To facilitate the adhesion of a poly(lactic acid) (PLA) overlayer loaded with rapamycin (20 wt%), a biodegradable macromonomer based on poly(lactic acid) (HEMA-PLA) was grafted onto the metallic stent by electrografting in a one-step reaction involving the immobilization of aryl diazonium onto the metal followed by an in situ surface electro-polymerization. The HEMA-PLA coating was chemically characterized. Mechanical performance during stent expansion was tested. Morphology examinations showed a strong adhesion of PLA topcoat in the presence of the electrografted layer. Biocompatibility and degradation of the coating were studied in vitro and in vivo in rabbit iliac arteries. These 28 days implantations resulted in a minimal inflammatory process with a partial degradation of the coating. These results suggest that this kind of anchoring of a biodegradable layer shows great potential for drug-eluting stents.


Assuntos
Stents Farmacológicos , Ácido Láctico/química , Metais/química , Polímeros/química , Sirolimo/administração & dosagem , Angioplastia/instrumentação , Animais , Artérias/patologia , Materiais Biocompatíveis , Adesão Celular , Reestenose Coronária/prevenção & controle , Sistemas de Liberação de Medicamentos , Eletroquímica , Humanos , Inflamação , Masculino , Poliésteres , Coelhos , Stents , Estresse Mecânico
3.
Invest Radiol ; 56(12): 826-836, 2021 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-34091462

RESUMO

OBJECTIVE: The aim of this study was to investigate the toxicological profile of gadopiclenol, a new high-relaxivity macrocyclic gadolinium-based contrast agent (GBCA), in renally impaired rats, in comparison with 2 other macrocyclic GBCAs, gadoterate meglumine and gadobutrol, and 1 linear and nonionic GBCA, gadodiamide. METHODS: Renal failure was induced by adding 0.75% wt/wt adenine to the diet for 3 weeks. During the second week of adenine-enriched diet, the animals (n = 8/group × 5 groups) received 5 consecutive intravenous injections of GBCA at 2.5 mmol/kg per injection, resulting in a cumulative dose of 12.5 mmol/kg or saline followed by a 3-week treatment-free period after the last injection. The total (elemental) gadolinium (Gd) concentration in different tissues (brain, cerebellum, femoral epiphysis, liver, skin, heart, kidney, spleen, plasma, urine, and feces) was measured by inductively coupled plasma mass spectrometry. Transmission electron microscopy (and electron energy loss spectroscopy analysis of metallic deposits) was used to investigate the presence and localization of Gd deposits in the skin. Relaxometry was used to evaluate the presence of dissociated Gd in the skin, liver, and bone. Skin histopathology was performed to investigate the presence of nephrogenic systemic fibrosis-like lesions. RESULTS: Gadodiamide administrations were associated with high morbidity-mortality but also with macroscopic and microscopic skin lesions in renally impaired rats. No such effects were observed with gadopiclenol, gadoterate, or gadobutrol. Overall, elemental Gd concentrations were significantly higher in gadodiamide-treated rats than in rats treated with the other GBCAs for all tissues except the liver (where no significant difference was found with gadopiclenol) and the kidney and the heart (where statistically similar Gd concentrations were observed for all GBCAs). No plasma biochemical abnormalities were observed with gadopiclenol or the control GBCAs. Histopathology revealed a normal skin structure in the rats treated with gadopiclenol, gadoterate, and gadobutrol, contrary to those treated with gadodiamide. No evidence of Gd deposits on collagen fibers and inclusions in fibroblasts was found with gadopiclenol and its macrocyclic controls, unlike with gadodiamide. Animals of all test groups had Gd-positive lysosomal inclusions in the dermal macrophages. However, the textures differed for the different products (speckled texture for gadodiamide and rough-textured appearance for the 2 tested macrocyclic GBCAs). CONCLUSIONS: No evidence of biochemical toxicity or pathological abnormalities of the skin was observed, and similar to other macrocyclic GBCAs, gadoterate and gadobutrol, tissue retention of Gd was found to be low (except in the liver) in renally impaired rats treated with the new high-relaxivity GBCA gadopiclenol.


Assuntos
Compostos Organometálicos , Insuficiência Renal , Adenina , Animais , Compostos Azabicíclicos , Encéfalo , Meios de Contraste , Gadolínio , Gadolínio DTPA , Ratos
4.
Eur J Heart Fail ; 19(11): 1520-1529, 2017 11.
Artigo em Inglês | MEDLINE | ID: mdl-28560782

RESUMO

AIMS: Left ventricular (LV) reverse remodelling is an important marker of improved outcomes in patients with advanced heart failure (HF). We examined the impact of the intramyocardial administration of bone-marrow-derived, lineage-directed, autologous cardiopoietic mesenchymal stem cells (C3BS-CQR-1) on LV remodelling in patients with advanced HF enrolled in the CHART-1 study. METHODS AND RESULTS: Patients (n=351) with symptomatic advanced HF secondary to ischaemic heart disease, and reduced LV ejection fraction (LVEF <35%) were randomized to receive C3BS-CQR-1 or a sham procedure. In a post hoc analysis we examined the effect of C3BS-CQR-1 on LV reverse remodelling within 1 year of the procedure and the influence of C3BS-CQR-1 dosing in the 271 patients treated as randomized. Delivery of C3BS-CQR-1 was associated with a progressive decrease in both LV end-diastolic volume (LVEDV) and end-systolic volume (LVESV) within 52 weeks after treatment. At 1 year, the LVEDV and LVESV of treated patients decreased by 17.0 mL and 12.8 mL greater than controls (P=0.006 and P=0.017, respectively). The effect on LVEDV was maintained after multivariable adjustment for baseline age, systolic blood pressure, LVEDV, LVEF and history of myocardial infarction. The largest reverse remodelling was evident in the patients receiving a moderate number of injections (<20). CONCLUSION: In CHART-1, intramyocardial administration of cardiopoietic stem cells led to reverse remodelling as evidenced by significant progressive decreases in LVEDV and LVESV through the 52 weeks of follow-up. Further studies are needed to explore the dose response with regard to cell number and injected volume, and reverse remodelling.


Assuntos
Terapia Genética/métodos , Insuficiência Cardíaca/terapia , Transplante de Células-Tronco Mesenquimais/métodos , Volume Sistólico/fisiologia , Função Ventricular Esquerda/fisiologia , Remodelação Ventricular/fisiologia , Feminino , Insuficiência Cardíaca/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
5.
Invest Radiol ; 41(1): 8-14, 2006 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-16355034

RESUMO

OBJECTIVE: The objective of this study was to compare the repartition in the renal arterial vasculature of tris-acryl gelatin microspheres (TGMS) and polyvinyl alcohol microspheres (PVAMS) of 3 calibers (500-700, 700-900, and 900-1200 microm). MATERIALS AND METHODS: Twelve kidneys from 6 adult sheep were embolized and histologically analyzed. The number and size of microspheres and vessels were measured, as well as the deformation of TGMS and PVAMS, and the histologic location according to a classification in 5 zones of the kidney. RESULTS: Two hundred eighty-four vessels were measured. The diameter of the occluded vessels increased when the caliber used for embolization was larger for TGMS and for PVAMS (P < 0.0001, each). The location of TGMS and PVAMS within the vasculature was different for each caliber, because PVAMS blocked significantly more distally than TGMS (P < 0.0001 each). The deformation within the tissue was greater for PVAMS (18.0 +/- 12.3%) than for TGMS (9.0 +/- 8.3%) in general (P < 0.001) and for each caliber of injected microspheres (P < 0.001 each). CONCLUSION: The repartition of a spherical embolic agent in a given vascular network can be influenced by its size and also by its deformation within the vascular bed.


Assuntos
Embolização Terapêutica/métodos , Gelatina/farmacocinética , Rim/irrigação sanguínea , Microesferas , Álcool de Polivinil/farmacocinética , Angiografia , Animais , Distribuição de Qui-Quadrado , Tamanho da Partícula , Distribuição Aleatória , Carneiro Doméstico , Estatísticas não Paramétricas
6.
J Cardiovasc Transl Res ; 8(6): 381-4, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26149227

RESUMO

Endomyocardial delivery in the setting of active left ventricular assist device (LVAD) support has rarely been studied. The objective was to establish a protocol for endomyocardial injections during LVAD support without compromising mechanical circulation. LVAD implantation was performed in four pigs. A curved needle catheter was percutaneously inserted into the right carotid artery and positioned into the left ventricle under fluoroscopic guidance. In the setting of increasing LVAD flows (2.3-3.1 l/min), percutaneous methylene blue dye administration into the myocardium proceeded without complications in all pigs. Transection of excised hearts revealed an anterior, lateral, inferior, and septal wall distribution of methylene blue documenting injections in all four regions of the left ventricle. Ex vivo, the catheter could be maneuvered close to the LVAD inflow cannula despite augmentation of LVAD flow up to 5 l/min. Endomyocardial injections during LVAD support was found to be feasible and safe with the curved needle catheter.


Assuntos
Cateterismo Cardíaco/métodos , Insuficiência Cardíaca/fisiopatologia , Ventrículos do Coração/fisiopatologia , Coração Auxiliar , Injeções , Miocárdio , Radiografia Intervencionista , Animais , Modelos Animais de Doenças , Fluoroscopia , Azul de Metileno , Suínos
7.
Circ Cardiovasc Interv ; 6(6): 710-8, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24326777

RESUMO

BACKGROUND: Regenerative cell-based therapies are associated with limited myocardial retention of delivered stem cells. The objective of this study is to develop an endocardial delivery system for enhanced cell retention. METHODS AND RESULTS: Stem cell retention was simulated in silico using 1- and 3-dimensional models of tissue distortion and compliance associated with delivery. Needle designs, predicted to be optimal, were accordingly engineered using nitinol, a nickel and titanium alloy displaying shape memory and superelasticity. Biocompatibility was tested with human mesenchymal stem cells. Experimental validation was performed with species-matched cells directly delivered into Langendorff-perfused porcine hearts or administered percutaneously into the endocardium of infarcted pigs. Cell retention was quantified by flow cytometry and real-time quantitative polymerase chain reaction methodology. Models, computing optimal distribution of distortion calibrated to favor tissue compliance, predicted that a 75°-curved needle featuring small-to-large graded side holes would ensure the highest cell retention profile. In isolated hearts, the nitinol curved needle catheter (C-Cath) design ensured 3-fold superior stem cell retention compared with a standard needle. In the setting of chronic infarction, percutaneous delivery of stem cells with C-Cath yielded a 37.7±7.1% versus 10.0±2.8% retention achieved with a traditional needle without effect on biocompatibility or safety. CONCLUSIONS: Modeling-guided development of a nitinol-based curved needle delivery system with incremental side holes achieved enhanced myocardial stem cell retention.


Assuntos
Sistemas de Liberação de Medicamentos/instrumentação , Sistemas de Liberação de Medicamentos/métodos , Endocárdio/citologia , Infarto do Miocárdio/terapia , Transplante de Células-Tronco , Células-Tronco/citologia , Ligas , Animais , Terapia Baseada em Transplante de Células e Tecidos , Simulação por Computador , Modelos Animais de Doenças , Desenho de Equipamento , Masculino , Infarto do Miocárdio/patologia , Agulhas , Suínos , Resultado do Tratamento
9.
Biomaterials ; 30(20): 3436-43, 2009 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-19345409

RESUMO

We report the preparation of an embolic agent based on specific association of an acrylic copolymer with dedicated particles formulated in ethanol. The copolymers were synthesized by radical polymerization of tertiobutylacrylamide (tBA) and 2-hydroxypropyl methacrylate (HPMA). Influences of the monomers composition, molecular weight and copolymer concentration have been evaluated on an in vitro model. Introduction of tBA units improves significantly the occlusion properties but these properties are similar whatever the molecular weight of the copolymer. As observed by viscosity studies, it seems necessary to work with a relatively high polymer concentration (C > Ce) to form a cohesive embolus. Addition of solid particles composed by a crosslinked polymer of 2-hydroxyethyl methacrylate (HEMA) and N-trishydroxymethyl methacrylamide (TRIS) in the acrylic copolymer solution has allowed to obtain an embole having an enhanced cohesion and giving a more compact structure. An in vivo evaluation has been performed by injection of this embolic agent in intercostal arteries and renal artery of sheep. There was no fragmentation of the plug during and after injection and a complete arterial occlusion by a cohesive embole. The pathological examination confirmed that there was a complete arterial occlusion by the plug and that the dedicated particles were as expected embedded in the precipitate acrylic copolymer.


Assuntos
Acrilamidas , Malformações Arteriovenosas/terapia , Embolização Terapêutica/métodos , Etanol/química , Géis , Metacrilatos , Polímeros , Acrilamidas/química , Acrilamidas/uso terapêutico , Animais , Materiais Biocompatíveis/química , Materiais Biocompatíveis/uso terapêutico , Géis/química , Géis/uso terapêutico , Humanos , Teste de Materiais , Metacrilatos/química , Metacrilatos/uso terapêutico , Peso Molecular , Polímeros/química , Polímeros/uso terapêutico , Ovinos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA