Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Circulation ; 147(17): 1264-1276, 2023 04 25.
Artigo em Inglês | MEDLINE | ID: mdl-36866664

RESUMO

BACKGROUND: Concerns have been raised about the long-term performance of aortic stent grafts for the treatment of abdominal aortic aneurysms, in particular, unibody stent grafts (eg, Endologix AFX AAA stent grafts). Only limited data sets are available to evaluate the long-term risks related to these devices. The SAFE-AAA Study (Comparison of Unibody and Non-Unibody Endografts for Abdominal Aortic Aneurysm Repair in Medicare Beneficiaries Study) was designed with the Food and Drug Administration to provide a longitudinal assessment of the safety of unibody aortic stent grafts among Medicare beneficiaries. METHODS: The SAFE-AAA Study was a prespecified, retrospective cohort study evaluating whether unibody aortic stent grafts are noninferior to non-unibody aortic stent grafts with respect to the composite primary outcome of aortic reintervention, rupture, and mortality. Procedures were evaluated from August 1, 2011, through December 31, 2017. The primary end point was evaluated through December 31, 2019. Inverse probability weighting was used to account for imbalances in observed characteristics. Sensitivity analyses were used to evaluate the effect of unmeasured confounding, including assessment of the falsification end points heart failure, stroke, and pneumonia. A prespecified subgroup included patients treated from February 22, 2016, through December 31, 2017, corresponding to the market release of the most contemporary unibody aortic stent grafts (Endologix AFX2 AAA stent graft). RESULTS: Of 87 163 patients who underwent aortic stent grafting at 2146 US hospitals, 11 903 (13.7%) received a unibody device. The average age of the total cohort was 77.0±6.7 years, 21.1% were female, 93.5% were White, 90.8% had hypertension, and 35.8% used tobacco. The primary end point occurred in 73.4% of unibody device-treated patients versus 65.0% of non-unibody device-treated patients (hazard ratio, 1.19 [95% CI, 1.15-1.22]; noninferior P value of 1.00; median follow-up, 3.4 years). Falsification end points were negligibly different between groups. In the subgroup treated with contemporary unibody aortic stent grafts, the cumulative incidence of the primary end point occurred in 37.5% of unibody device-treated patients and 32.7% of non-unibody device-treated patients (hazard ratio, 1.06 [95% CI, 0.98-1.14]). CONCLUSIONS: In the SAFE-AAA Study, unibody aortic stent grafts failed to meet noninferiority compared with non-unibody aortic stent grafts with respect to aortic reintervention, rupture, and mortality. These data support the urgency of instituting a prospective longitudinal surveillance program for monitoring safety events related to aortic stent grafts.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Feminino , Idoso , Estados Unidos , Idoso de 80 Anos ou mais , Masculino , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Estudos Retrospectivos , Estudos Prospectivos , Resultado do Tratamento , Procedimentos Endovasculares/efeitos adversos , Medicare , Stents , Desenho de Prótese
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA