Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
J Vis ; 21(13): 11, 2021 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-34940825

RESUMO

The purpose of this study was to evaluate fixational eye movements (FEMs) with high spatial and temporal resolution following concussion, where oculomotor symptoms and impairments are common. Concussion diagnosis was determined using current consensus guidelines. A retinal eye-tracking device, the tracking scanning laser ophthalmoscope (TSLO), was used to measure FEMs in adolescents and young adults following a concussion and in an unaffected control population. FEMs were quantified in two fixational paradigms: (1) when fixating on the center, or (2) when fixating on the corner of the TSLO imaging raster. Fixational saccade amplitude in recent concussion patients (≤ 21 days) was significantly greater, on average, in the concussion group (mean = 1.03°; SD = 0.36°) compared with the controls (mean = 0.82°; SD = 0.31°), when fixating on the center of the imaging raster (t = 2.87, df = 82, p = 0.005). These fixational saccades followed the main sequence and therefore also had greater peak velocity (t = 2.86, df = 82, p = 0.006) and peak acceleration (t = 2.80, df = 82, p = 0.006). These metrics significantly differentiated concussed from controls (AUC = 0.67-0.68, minimum p = 0.005). No group differences were seen for the drift metrics in either task or for any of the FEMs metrics in the corner-of-raster fixation task. Fixational saccade amplitudes were significantly different in the concussion group, but only when fixating on the center of the raster. This task specificity suggests that task optimization may improve differentiation and warrants further study. FEMs measured in the acute-to-subacute period of concussion recovery may provide a quick (<3 minutes), objective, sensitive, and accurate ocular dysfunction assessment. Future work should assess the impact of age, mechanism of injury, and post-concussion recovery on FEM alterations following concussion.


Assuntos
Movimentos Oculares , Fixação Ocular , Adolescente , Olho , Humanos , Movimentos Sacádicos , Visão Ocular , Adulto Jovem
2.
Mult Scler ; 26(3): 343-353, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-32031464

RESUMO

BACKGROUND: Objective tools for prognosis and disease progression monitoring in multiple sclerosis (MS) are lacking. The visuomotor system could be used to track motor dysfunction at the micron scale through the monitoring of fixational microsaccades. AIMS: The aim of this study was to evaluate whether microsaccades are correlated with standard MS disability metrics and to assess whether these methods play a predictive role in MS disability. METHOD: We used a custom-built retinal eye tracker, the tracking scanning laser ophthalmoscope (TSLO), to record fixation in 111 participants with MS and 100 unaffected controls. RESULTS: In MS participants, a greater number of microsaccades showed significant association with higher Expanded Disability Status Scale score (EDSS, p < 0.001), nine-hole peg test (non-dominant: p = 0.006), Symbol Digit Modalities Test (SMDT, p = 0.014), and Functional Systems Scores (FSS) including brainstem (p = 0.005), cerebellar (p = 0.011), and pyramidal (p = 0.009). Both brainstem FSS and patient-reported fatigue showed significant associations with microsaccade number, amplitude, and peak acceleration. Participants with MS showed a statistically different average number (p = 0.020), peak vertical acceleration (p = 0.003), and vertical amplitude (p < 0.001) versus controls. Logistic regression models for MS disability were created using TSLO microsaccade metrics and paraclinical tests with ⩾80% accuracy. CONCLUSION: Microsaccades provide objective measurements of MS disability level and disease worsening.


Assuntos
Tecnologia de Rastreamento Ocular , Fixação Ocular/fisiologia , Esclerose Múltipla/fisiopatologia , Movimentos Sacádicos/fisiologia , Adulto , Idoso , Biomarcadores , Progressão da Doença , Tecnologia de Rastreamento Ocular/instrumentação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Índice de Gravidade de Doença , Adulto Jovem
3.
J Neuroophthalmol ; 38(4): 488-493, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30418331

RESUMO

: BACKGROUND:: Multiple sclerosis (MS) is an inflammatory disease of the central nervous system causing the immune-mediated demyelination of the brain, optic nerve, and spinal cord and resulting in ultimate axonal loss and permanent neurological disability. Ocular motor dysfunction is commonly observed in MS but can be frequently overlooked or underappreciated by nonspecialists. Therefore, detailed and quantitative assessment of eye movement function has significant potential for optimization of patient care, especially for clinicians interested in treating visual symptoms or tracking disease progression. METHODS:: A brief history of eye tracking technology followed by a contextualized review of the methods that can be used to assess ocular motor dysfunction in MS-including a discussion of each method's strengths and limitations. We discuss the rationale for interest in this area and describe new tools capable of tracking eye movements as a possible means of monitoring disease. RESULTS/CONCLUSIONS:: This overview should inform clinicians working with patients with MS of how ocular motor deficits can best be assessed and monitored in this population. It also provides a rationale for interest in this field with insights regarding which techniques should be used for studying which classes of eye movements and related dysfunction in the disease.


Assuntos
Técnicas de Diagnóstico Oftalmológico , Movimentos Oculares/fisiologia , Esclerose Múltipla/complicações , Transtornos da Motilidade Ocular/diagnóstico , Progressão da Doença , Humanos , Esclerose Múltipla/diagnóstico , Transtornos da Motilidade Ocular/etiologia , Transtornos da Motilidade Ocular/fisiopatologia
4.
J Vis ; 18(5): 8, 2018 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-29904783

RESUMO

Human eyes are never stable, even during attempts of maintaining gaze on a visual target. Considering transient response characteristics of retinal ganglion cells, a certain amount of motion of the eyes is required to efficiently encode information and to prevent neural adaptation. However, excessive motion of the eyes leads to insufficient exposure to the stimuli, which creates blur and reduces visual acuity. Normal miniature eye movements fall in between these extremes, but it is unclear if they are optimally tuned for seeing fine spatial details. We used a state-of-the-art retinal imaging technique with eye tracking to address this question. We sought to determine the optimal gain (stimulus/eye motion ratio) that corresponds to maximum performance in an orientation-discrimination task performed at the fovea. We found that miniature eye movements are tuned but may not be optimal for seeing fine spatial details.


Assuntos
Sensibilidades de Contraste/fisiologia , Movimentos Oculares/fisiologia , Visão Ocular/fisiologia , Adolescente , Adulto , Humanos , Retina/fisiologia , Células Ganglionares da Retina/fisiologia , Acuidade Visual/fisiologia , Adulto Jovem
5.
Transl Vis Sci Technol ; 11(2): 35, 2022 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-35201339

RESUMO

PURPOSE: The purpose of this study was to characterize the benign biological variance of fixational microsaccades in a control population using a tracking scanning laser ophthalmoscope (TSLO), accounting for machine accuracy and precision, to determine ideal testing conditions to detect pathologic change in fixational eye motion (FEM). METHODS: We quantified the accuracy and precision of the TSLO, analyzing measurements made by three operators on a model eye. Repeated, 10-second retinal motion traces were then recorded in 17 controls, 3 times a day (morning, afternoon, and evening), on 3 separate days. Microsaccade metrics (MMs) of frequency, average amplitude, peak velocity, and peak acceleration were extracted. Trace to trace, interday, and intraday variability were calculated across all subjects. RESULTS: Intra-operator and machine variation contributed minimally to total variation, with only 0.007% and 0.14% contribution for frequency and amplitude respectively. Bias was detected, with lower accuracy for higher amplitudes. Participants had an average (SD) microsaccade frequency of 0.84 Hz (0.52 Hz), amplitude of 0.32 degrees (0.11 degrees), peak velocity of 43.68 degrees/s (14.02 degrees/s), and peak acceleration of 13,920.04 degrees/s2 (4,186.84 degrees/s2). The first trace recorded within a session significantly differed from the second two in both microsaccade acceleration and velocity (P < 0.05), and frequency was 0.098 Hz higher in the evenings (P < 0.05). There was no MM difference between days and no evidence of a session-level learning effect (P > 0.05). CONCLUSIONS: The TSLO is both accurate and precise. However, biological inter- and intra-individual variance is present. Trace to trace variability and time of day should be accounted for to optimize detection of pathologic change.


Assuntos
Fixação Ocular , Oftalmoscópios , Humanos , Lasers , Movimento (Física) , Retina
6.
Biomed Opt Express ; 6(7): 2412-23, 2015 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-26203370

RESUMO

We demonstrate a system that combines a tracking scanning laser ophthalmoscope (TSLO) and an adaptive optics scanning laser ophthalmoscope (AOSLO) system resulting in both optical (hardware) and digital (software) eye-tracking capabilities. The hybrid system employs the TSLO for active eye-tracking at a rate up to 960 Hz for real-time stabilization of the AOSLO system. AOSLO videos with active eye-tracking signals showed, at most, an amplitude of motion of 0.20 arcminutes for horizontal motion and 0.14 arcminutes for vertical motion. Subsequent real-time digital stabilization limited residual motion to an average of only 0.06 arcminutes (a 95% reduction). By correcting for high amplitude, low frequency drifts of the eye, the active TSLO eye-tracking system enabled the AOSLO system to capture high-resolution retinal images over a larger range of motion than previously possible with just the AOSLO imaging system alone.

7.
Biomed Opt Express ; 4(1): 51-65, 2013 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-23304647

RESUMO

In phase-resolved OCT angiography blood flow is detected from phase changes in between A-scans that are obtained from the same location. In ophthalmology, this technique is vulnerable to eye motion. We address this problem by combining inter-B-scan phase-resolved OCT angiography with real-time eye tracking. A tracking scanning laser ophthalmoscope (TSLO) at 840 nm provided eye tracking functionality and was combined with a phase-stabilized optical frequency domain imaging (OFDI) system at 1040 nm. Real-time eye tracking corrected eye drift and prevented discontinuity artifacts from (micro)saccadic eye motion in OCT angiograms. This improved the OCT spot stability on the retina and consequently reduced the phase-noise, thereby enabling the detection of slower blood flows by extending the inter-B-scan time interval. In addition, eye tracking enabled the easy compounding of multiple data sets from the fovea of a healthy volunteer to create high-quality eye motion artifact-free angiograms. High-quality images are presented of two distinct layers of vasculature in the retina and the dense vasculature of the choroid. Additionally we present, for the first time, a phase-resolved OCT angiogram of the mesh-like network of the choriocapillaris containing typical pore openings.

8.
Biomed Opt Express ; 3(11): 2950-63, 2012 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-23162731

RESUMO

Fixational eye movements remain a major cause of artifacts in optical coherence tomography (OCT) images despite the increases in acquisition speeds. One approach to eliminate the eye motion is to stabilize the ophthalmic imaging system in real-time. This paper describes and quantifies the performance of a tracking OCT system, which combines a phase-stabilized optical frequency domain imaging (OFDI) system and an eye tracking scanning laser ophthalmoscope (TSLO). We show that active eye tracking minimizes artifacts caused by eye drift and micro saccades. The remaining tracking lock failures caused by blinks and large saccades generate a trigger signal which signals the OCT system to rescan corrupted B-scans. Residual motion artifacts in the OCT B-scans are reduced to 0.32 minutes of arc (~1.6 µm) in an in vivo human eye enabling acquisition of high quality images from the optic nerve head and lamina cribrosa pore structure.

9.
Biomed Opt Express ; 3(10): 2611-22, 2012 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-23082300

RESUMO

We demonstrate a high-speed, image-based tracking scanning laser ophthalmoscope (TSLO) that can provide high fidelity structural images, real-time eye tracking and targeted stimulus delivery. The system was designed for diffraction-limited performance over an 8° field of view (FOV) and operates with a flexible field of view of 1°-5.5°. Stabilized videos of the retina were generated showing an amplitude of motion after stabilization of 0.2 arcmin or less across all frequencies. In addition, the imaging laser can be modulated to place a stimulus on a targeted retinal location. We show a stimulus placement accuracy with a standard deviation less than 1 arcmin. With a smaller field size of 2°, individual cone photoreceptors were clearly visible at eccentricities outside of the fovea.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA