Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
BMC Oral Health ; 23(1): 775, 2023 10 21.
Artigo em Inglês | MEDLINE | ID: mdl-37865734

RESUMO

AIM: The implant-abutment connection is a crucial factor in determining the long-term stability of dental implants. The use of a prosthetic index structure in the Morse taper implant-abutment connection has been proposed as a potential solution to improve the accuracy of this connection. This study aimed to provide a scoping review of the mechanical and clinical effects of the prosthetic index structure in the Morse taper implant-abutment connection. METHODS: A systematic scoping review of articles related to "dental implants," "Morse taper," and "index" was conducted using PubMed/MEDLINE, Web of Science, Cochrane, and Scopus databases, as well as a comprehensive literature search by two independent reviewers. Relevant articles were selected for analysis and discussion, with a specific focus on investigating the impact of prosthetic index structure on the mechanical and clinical aspects of Morse taper implant-abutment connections. RESULTS: Finally, a total of 16 articles that met the inclusion criteria were included for data extraction and review. In vitro studies have demonstrated that the use of a prosthetic index structure in the Morse taper implant-abutment connection can affect stress distribution, biomechanical stability, and reverse torque values, which may reduce stress within cancellous bone and help limit crestal bone resorption. However, retrospective clinical studies have shown that this structure is also associated with a higher risk of mechanical complications, such as abutment fracture and abutment screw loosening. CONCLUSIONS: Therefore, the clinical trade-off between preventing crestal bone resorption and mechanical complications must be carefully considered when selecting appropriate abutments. The findings suggest that this structure can improve the accuracy and stability of the implant-abutment connection, but its use should be carefully evaluated in clinical practice.


Assuntos
Reabsorção Óssea , Implantes Dentários , Humanos , Estudos Retrospectivos , Torque , Bases de Dados Factuais , Estresse Mecânico , Análise do Estresse Dentário
2.
BMC Oral Health ; 23(1): 179, 2023 03 28.
Artigo em Inglês | MEDLINE | ID: mdl-36978064

RESUMO

BACKGROUND: To compare the accuracy of dental implant placement using a novel dental implant robotic system (THETA) and a dynamic navigation system (Yizhimei) by a vitro model experiment. METHODS: 10 partially edentulous jaws models were included in this study, and 20 sites were randomly assigned into two groups: the dental implant robotic system (THETA) group and a dynamic navigation system (Yizhimei) group. 20 implants were placed in the defects according to each manufacturer's protocol respectively. The implant platform, apex and angle deviations were measured by fusion of the preoperative design and the actual postoperative cone-beam computed tomography (CBCT) using 3D Slicer software. Data were analyzed by t - test and Mann-Whitney U test, p < 0.05 was considered statistically significant. RESULTS: A total of 20 implants were placed in 10 phantoms. The comparison deviation of implant platform, apex and angulation in THETA group were 0.58 ± 0.31 mm, 0.69 ± 0.28 mm, and 1.08 ± 0.66° respectively, while in Yizhimei group, the comparison deviation of implant platform, apex and angulation were 0.73 ± 0.20 mm, 0.86 ± 0.33 mm, and 2.32 ± 0.71° respectively. The angulation deviation in THETA group was significantly smaller than the Yizhimei group, and there was no significant difference in the deviation of the platform and apex of the implants placed using THETA and Yizhimei, respectively. CONCLUSION: The implant positioning accuracy of the robotic system, especially the angular deviation was superior to that of the dynamic navigation system, suggesting that the THETA robotic system could be a promising tool in dental implant surgery in the future. Further clinical studies are needed to evaluate the current results.


Assuntos
Implantação Dentária Endóssea , Procedimentos Cirúrgicos Robóticos , Cirurgia Assistida por Computador , Humanos , Desenho Assistido por Computador , Tomografia Computadorizada de Feixe Cônico , Implantação Dentária Endóssea/métodos , Implantes Dentários , Imageamento Tridimensional , Projetos Piloto , Cirurgia Assistida por Computador/métodos , Modelos Anatômicos , Imagens de Fantasmas
3.
Sensors (Basel) ; 20(17)2020 Aug 27.
Artigo em Inglês | MEDLINE | ID: mdl-32867021

RESUMO

We have developed an alginate hydrogel-embedded capillary sensor (AHCS) for naked eye-based quantification of immunoassay. Alkaline phosphatase (ALP) can modulate gel-sol transformation to increase the permeability of Cu2+-cross-linked alginate hydrogel film in the AHCS, followed by solution exchange into the capillary. Through measuring the length of the liquid phase of the microfluidics in the capillary at a given time, the concentration of the ALP could be quantified with the naked eye. Since ALP is widely applied as a signal reporter for immunoassays, the AHCS could easily accommodate conventional immune sensing platforms. We justify the practicality of AHCS with hepatitis B virus surface antigen (HBsAg) in serum samples and got comparable results with commercialized immunoassay. This AHCS is easy to make and use, effective in cost, and robust in quantification with the naked eye, showing great promise for next generation point-of-care testing.


Assuntos
Alginatos , Antígenos de Superfície da Hepatite B/análise , Hidrogéis , Imunoensaio/métodos , Fosfatase Alcalina/química , Antígenos de Superfície da Hepatite B/sangue , Humanos
4.
Medicine (Baltimore) ; 103(19): e37448, 2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38728494

RESUMO

BACKGROUND: Idiopathic gingival enlargement is associated with plaque, but other contributing factors are unclear. The prognosis of idiopathic gingival enlargement is closely related to the patient's oral hygiene habits and regular follow-up. CASE PRESENTATION: This article reports a case of a 32-year-old male patient with idiopathic gingival enlargement. The patient presented to the department of stomatology with a 2-month history of gingival swelling and pain on the right upper posterior teeth. During the treatment, oral hygiene instruction, supragingival cleaning, subgingival scaling, and root planning were carried out, and part of the hyperplastic gingiva was taken and sent for pathology. Pathological examination showed gingival enlargement with chronic suppurative inflammation. At 4-month follow-up, the patient's periodontal condition remained basically stable, and the gingival enlargement did not recur. CONCLUSION: The treatment of this case resulted in significant reduction of gingival swelling and patient's pain reduction through non-surgical treatment and good plaque control, indicating that patients with idiopathic gingival enlargement can also achieve ideal results through non-surgical treatment. Through oral hygiene instruction, the patient mastered the method of self-plaque control, which is conducive to the long-term stabilization of the periodontal situation.


Assuntos
Higiene Bucal , Humanos , Masculino , Adulto , Higiene Bucal/educação , Higiene Bucal/métodos , Raspagem Dentária/métodos , Hiperplasia Gengival/terapia , Aplainamento Radicular
5.
ACS Omega ; 7(18): 15385-15395, 2022 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-35571834

RESUMO

Heavy metal ions in contaminated water, such as hexavalent chromium, are harmful to humans. Bacterial biosorption is an ideal method for the treatment of hexavalent chromium. However, hexavalent chromium in solution causes bacteria to produce reactive oxygen species, which leads to bacterial death and affects biosorption. We developed a microfluidics-based biomimetic mineralization method to encapsulate bacteria (e.g., Escherichia coli and Bacillus subtilis) with zeolitic imidazolate framework-8 (ZIF-8), thus allowing the bacteria to form a continuous and homogeneous shell. The artificial shells endowed bacteria with the ability to tolerate harsh environments, which was significant during the treatment of contaminated water. The adsorption of hexavalent chromium was a two-step process: first the fast physical adsorption of ZIF-8 and biosorption by bacteria (up to 30-50% adsorption in 1 day), followed by secondary biosorption after decomposition of the system. The maximum adsorption of hexavalent chromium by the encapsulated bacteria reached 90%. The microfluidic device developed in this study provides a simple method to encapsulate bacteria mildly and enable cell survival in extreme environments, offering the possibility of future microbial applications in environmental and other fields.

6.
Front Chem ; 10: 771027, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35127636

RESUMO

The treatment of tongue squamous cell carcinoma (TSCC) faces challenges because TSCC has an aggressive biological behavior and manifests usually as widespread metastatic disease. Therefore, it is particularly important to screen out and develop drugs that inhibit tumor invasion and metastasis. Two-dimensional (2D) cell culture has been used as in vitro models to study cellular biological behavior, but growing evidence now shows that the 2D systems can result in cell bioactivities that deviate appreciably the in vivo response. It is urgent to develop a novel 3D cell migration model in vitro to simulate the tumor microenvironment as much as possible and screen out effective anti-migration drugs. Sodium alginate, has a widely used cell encapsulation material, as significant advantages. We have designed a microfluidic device to fabricate a hollow alginate hydrogel microtube model. Based on the difference in liquid flow rate, TSCC cells (Cal27) were able to be evenly distributed in the hollow microtubes, which was confirmed though fluorescence microscope and laser scanning confocal microscope (LSCM). Our microfluidic device was cheap, and commercially available and could be assembled in a modular way, which are composed of a coaxial needle, silicone hose, and syringes. It was proved that the cells grow well in artificial microtubes with extracellular matrix (ECM) proteins by LSCM and flow cytometry. Periodic motility conferred a different motor state to the cells in the microtubes, more closely resembling the environment in vivo. The quantitative analysis of tumor cell migration could be achieved simply by determining the position of the cell in the microtube cross-section. We verified the anti-migration effects of three NSAIDs drugs (aspirin, indomethacin, and nimesulide) with artificial microtubes, obtaining the same results as conventional migration experiments. The results showed that among the three NSAIDs, nimesulide showed great anti-migration potential against TSCC cells. Our method holds great potential for application in the more efficient screening of anti-migration tumor drugs.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA