Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 46
Filtrar
1.
Pacing Clin Electrophysiol ; 44(4): 744-746, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33432675

RESUMO

The ARTO device is a percutaneous device for functional mitral regurgitation composed of a transseptal anchor and a T-bar sitting in the coronary sinus which reduce the minor axis of the mitral valve. We present a case showing the technical feasibility of an LV lead implant in patients with an ARTO device in situ.


Assuntos
Cateterismo Cardíaco/instrumentação , Insuficiência da Valva Mitral/terapia , Marca-Passo Artificial , Idoso , Ecocardiografia , Eletrocardiografia , Humanos , Masculino , Desenho de Prótese
2.
Europace ; 21(6): 928-936, 2019 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-30590509

RESUMO

AIMS: Transvenous lead extraction (TLE) may be necessary due to system infection/erosion or lead malfunction. Cardiac resynchronization therapy (CRT) patients undergoing TLE may be at greater risk due to increased comorbidities. We examined whether patients with CRT systems undergoing TLE had more comorbidities and higher 30-day mortality than those with non-CRT devices. METHODS AND RESULTS: All TLEs between October 2000 and December 2016 were prospectively collected. During this period 925 TLEs occurred (CRT group 231, non-CRT group 694). Cardiac resynchronization therapy patients were older (68.1 ± 10.8 years vs. 64.3 ± 16.1 years, P = 0.024); more likely male (85.7% vs. 69%, P < 0.001); had lower mean left ventricular ejection fraction (34.1 ± 12.7% vs. 48.3 ± 12.9%, P < 0.001); had higher prevalence of renal impairment (33.8% vs. 13.7%, P < 0.001) and were more likely to have ≥2 comorbidities (84% vs. 40.1%, P < 0.001). Mean lead dwell time was lower in the CRT group (5.6 ± 5.5 years vs. 7.6 ± 7.1 years, P = 0.002). There was no significant difference in all-cause 30-day mortality rates between CRT (3.0%, n = 7) and non-CRT patients (2.0%, n = 14) (P = 0.443). The majority of deaths in both groups were due to sepsis. Univariate and multivariate analysis showed age, renal impairment and sepsis were associated with increased risk of 30-day mortality. Transvenous lead extraction of a CRT system did not predict 30-day mortality. CONCLUSION: Transvenous lead extraction in CRT patients was not associated with increased 30-day mortality when compared with non-CRT patients. Age, renal impairment and sepsis were independent predictors of 30-day mortality. Sepsis was the main cause of 30-day mortality.


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca , Remoção de Dispositivo , Mortalidade/tendências , Idoso , Causas de Morte , Comorbidade , Falha de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Fatores de Risco
3.
Pacing Clin Electrophysiol ; 42(1): 73-84, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30411817

RESUMO

BACKGROUND: Transvenous lead extraction (TLE) may be necessary due to infective and noninfective indications. We aim to identify predictors of 30-day mortality and risk factors between infective versus noninfective groups and systemic versus local infection subgroups. METHODS: A total of 925 TLEs between October 2000 and December 2016 were prospectively collected and dichotomized (infective group n = 505 vs noninfective group n = 420 and systemic infection n = 164 vs local infection n = 341). RESULTS: All-cause major complication including deaths was significantly higher (5.1%, n = 26 vs 1.2%, n = 5, P = 0.001) as well as 30-day mortality (4.0%, n = 20 vs 0.2%, n = 1, P < 0.001) in the infective group compared to the noninfective group. Both subgroups (systemic vs local infection) were balanced for demographics. All-cause major complication including deaths was significantly higher (9.1%, n = 15 vs 3.2%, n = 11, P = 0.008) as well as all-cause 30-day mortality (7.9%, n  = 13 vs 2.1%, n = 7, P = 0.003) in the systemic infection subgroup compared to the local infection subgroup. CONCLUSION: Patients undergoing TLE for infective indications are at greater risk of 30-day all-cause mortality compared to noninfective patients. Patients undergoing TLE for systemic infective indications are at greater risk of 30-day all-cause mortality compared to patients with local infection. Renal impairment, systemic infection, and elevated preprocedure C-reactive protein are independent predictors of 30-day all-cause mortality in patients undergoing TLE for an infective indication.


Assuntos
Desfibriladores Implantáveis/efeitos adversos , Remoção de Dispositivo/métodos , Marca-Passo Artificial/efeitos adversos , Infecções Relacionadas à Prótese/etiologia , Infecções Relacionadas à Prótese/mortalidade , Idoso , Causas de Morte , Remoção de Dispositivo/efeitos adversos , Feminino , Humanos , Masculino , Valor Preditivo dos Testes , Estudos Prospectivos , Medição de Risco , Fatores de Risco
4.
Pacing Clin Electrophysiol ; 42(10): 1355-1364, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31433064

RESUMO

BACKGROUND: Transvenous lead extraction (TLE) may be performed by superior approach using the original implant vein or via a femoral approach; however, limited comparative data exists. We compare outcomes between femoral versus nonfemoral TLE approaches and determine predictors of bailout transfemoral lead extraction in patients undergoing initial TLE via the original implant vein by a superior approach. METHODS: All consecutive TLEs between October 2000 and March 2018 were prospectively collected (n = 1052). Patients were dichotomized into femoral (n = 118) and nonfemoral (n = 934) groups. RESULTS: Demographics were balanced between femoral vs nonfemoral groups. Patients in the femoral group had significantly higher mean lead dwell times (11.6 ± 9.7 vs 6.6 ± 6.6 years, P < .001), mean number of leads extracted (2.7 ± 1.3 vs 2.0 ± 1.0, P < .001), 30-day procedure related major complications (including deaths) (8.5% vs 1.1%, P < .001) and emergency thoracotomy rates (4.2% vs 0.7%, P = .007). All-cause 30-day mortality rates were similar between groups (3.4% vs 2.0%, P = .315). Prolonged lead dwell time and increased number of leads extracted were predictive of a bailout transfemoral approach at multivariable analysis. CONCLUSION: Femoral approach TLE is associated with increased risk of 30-day procedure related major complications but not 30-day all-cause mortality. Prolonged lead dwell time and increased number of leads extracted are independent predictors for bailout transfemoral lead extraction. Such patients should be considered high risk of major complications and performed by high-volume lead extraction centers with experience in multiple approaches and techniques including experience with transfemoral lead extraction.


Assuntos
Desfibriladores Implantáveis/efeitos adversos , Remoção de Dispositivo , Marca-Passo Artificial/efeitos adversos , Idoso , Desenho de Equipamento , Falha de Equipamento , Veia Femoral , Humanos , Pessoa de Meia-Idade , Estudos Prospectivos , Sistema de Registros , Fatores de Risco , Fatores de Tempo
5.
J Cardiovasc Electrophysiol ; 28(2): 208-215, 2017 02.
Artigo em Inglês | MEDLINE | ID: mdl-27885749

RESUMO

BACKGROUND: Cardiac anatomy and function adapt in response to chronic cardiac resynchronization therapy (CRT). The effects of these changes on the optimal left ventricle (LV) lead location and timing delay settings have yet to be fully explored. OBJECTIVE: To predict the effects of chronic CRT on the optimal LV lead location and device timing settings over time. METHODS: Biophysical computational cardiac models were generated for 3 patients, immediately post-implant (ACUTE) and after at least 6 months of CRT (CHRONIC). Optimal LV pacing area and device settings were predicted by pacing the ACUTE and CHRONIC models across the LV epicardium (49 sites each) with a range of 9 pacing settings and simulating the acute hemodynamic response (AHR) of the heart. RESULTS: There were statistically significant differences between the distribution of the AHR in the ACUTE and CHRONIC models (P < 0.0005 in all cases). The site delivering the maximal AHR shifted location between the ACUTE and CHRONIC models but provided a negligible improvement (<2%). The majority of the acute optimal LV pacing regions (76-100%) and device settings (76-91%) remained optimal chronically. CONCLUSION: Optimization of the LV pacing location and device settings were important at the time of implant, with a reduced benefit over time, where the majority of the acute optimal LV pacing region and device settings remained optimal with chronic CRT.


Assuntos
Terapia de Ressincronização Cardíaca/métodos , Insuficiência Cardíaca/terapia , Modelos Cardiovasculares , Modelagem Computacional Específica para o Paciente , Função Ventricular Esquerda , Potenciais de Ação , Idoso , Mapeamento Epicárdico , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Tempo , Resultado do Tratamento
6.
J Mol Cell Cardiol ; 96: 93-100, 2016 07.
Artigo em Inglês | MEDLINE | ID: mdl-26546827

RESUMO

Cardiac resynchronisation therapy (CRT) is an established treatment for heart failure, however the effective selection of patients and optimisation of therapy remain controversial. While extensive research is ongoing, it remains unclear whether improvements in patient selection or therapy planning offers a greater opportunity for the improvement of clinical outcomes. This computational study investigates the impact of both physiological conditions that guide patient selection and the optimisation of pacing lead placement on CRT outcomes. A multi-scale biophysical model of cardiac electromechanics was developed and personalised to patient data in three patients. These models were separated into components representing cardiac anatomy, pacing lead location, myocardial conductivity and stiffness, afterload, active contraction and conduction block for each individual, and recombined to generate a cohort of 648 virtual patients. The effect of these components on the change in total activation time of the ventricles (ΔTAT) and acute haemodynamic response (AHR) was analysed. The pacing site location was found to have the largest effect on ΔTAT and AHR. Secondary effects on ΔTAT and AHR were found for functional conduction block and cardiac anatomy. The simulation results highlight a need for a greater emphasis on therapy optimisation in order to achieve the best outcomes for patients.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/terapia , Modelos Cardiovasculares , Idoso , Idoso de 80 Anos ou mais , Simulação por Computador , Feminino , Insuficiência Cardíaca/diagnóstico , Hemodinâmica , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Miocárdio/metabolismo , Disfunção Ventricular
7.
J Cardiovasc Electrophysiol ; 27(7): 851-60, 2016 07.
Artigo em Inglês | MEDLINE | ID: mdl-27094470

RESUMO

INTRODUCTION: Computational modeling of cardiac arrhythmogenesis and arrhythmia maintenance has made a significant contribution to the understanding of the underlying mechanisms of arrhythmia. We hypothesized that a cardiac model using personalized electro-anatomical parameters could define the underlying ventricular tachycardia (VT) substrate and predict reentrant VT circuits. We used a combined modeling and clinical approach in order to validate the concept. METHODS AND RESULTS: Non-contact electroanatomic mapping studies were performed in 7 patients (5 ischemics, 2 non-ischemics). Three ischemic cardiomyopathy patients underwent a clinical VT stimulation study. Anatomical information was obtained from cardiac magnetic resonance imaging (CMR) including high-resolution scar imaging. A simplified biophysical mono-domain action potential model personalized with the patients' anatomical and electrical information was used to perform in silico VT stimulation studies for comparison. The personalized in silico VT stimulations were able to predict VT inducibility as well as the macroscopic characteristics of the VT circuits in patients who had clinical VT stimulation studies. The patients with positive clinical VT stimulation studies had wider distribution of action potential duration restitution curve (APD-RC) slopes and APDs than the patient with a negative VT stimulation study. The exit points of reentrant VT circuits encompassed a higher percentage of the maximum APD-RC slope compared to the scar and non-scar areas, 32%, 4%, and 0.2%, respectively. CONCLUSIONS: VT stimulation studies can be simulated in silico using a personalized biophysical cardiac model. Myocardial spatial heterogeneity of APD restitution properties and conductivity may help predict the location of crucial entry/exit points of reentrant VT circuits.


Assuntos
Técnicas Eletrofisiológicas Cardíacas , Sistema de Condução Cardíaco/fisiopatologia , Modelos Cardiovasculares , Modelagem Computacional Específica para o Paciente , Taquicardia Ventricular/diagnóstico , Potenciais de Ação , Idoso , Idoso de 80 Anos ou mais , Fenômenos Biomecânicos , Feminino , Sistema de Condução Cardíaco/patologia , Frequência Cardíaca , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Miocárdio/patologia , Valor Preditivo dos Testes , Estudos Prospectivos , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/fisiopatologia , Fatores de Tempo
8.
Europace ; 18(suppl 4): iv113-iv120, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28011838

RESUMO

AIMS: The efficacy of cardiac resynchronization therapy (CRT) is known to vary considerably with pacing location, however the most effective set of metrics by which to select the optimal pacing site is not yet well understood. Computational modelling offers a powerful methodology to comprehensively test the effect of pacing location in silico and investigate how to best optimize therapy using clinically available metrics for the individual patient. METHODS AND RESULTS: Personalized computational models of cardiac electromechanics were used to perform an in silico left ventricle (LV) pacing site optimization study as part of biventricular CRT in three patient cases. Maps of response to therapy according to changes in total activation time (ΔTAT) and acute haemodynamic response (AHR) were generated and compared with preclinical metrics of electrical function, strain, stress, and mechanical work to assess their suitability for selecting the optimal pacing site. In all three patients, response to therapy was highly sensitive to pacing location, with laterobasal locations being optimal. ΔTAT and AHR were found to be correlated (ρ < -0.80), as were AHR and the preclinical activation time at the pacing site (ρ ≥ 0.73), however pacing in the last activated site did not result in the optimal response to therapy in all cases. CONCLUSION: This computational modelling study supports pacing in laterobasal locations, optimizing pacing site by minimizing paced QRS duration and pacing in regions activated late at sinus rhythm. Results demonstrate information content is redundant using multiple preclinical metrics. Of significance, the correlation of AHR with ΔTAT indicates that minimization of QRSd is a promising metric for optimization of lead placement.


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca , Terapia de Ressincronização Cardíaca/métodos , Insuficiência Cardíaca/terapia , Modelos Cardiovasculares , Modelagem Computacional Específica para o Paciente , Potenciais de Ação , Idoso , Idoso de 80 Anos ou mais , Técnicas Eletrofisiológicas Cardíacas , Desenho de Equipamento , Feminino , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Processamento de Sinais Assistido por Computador , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda
9.
J Cardiovasc Magn Reson ; 16: 58, 2014 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-25084814

RESUMO

BACKGROUND: Many patients with electrical dyssynchrony who undergo cardiac resynchronization therapy (CRT) do not obtain substantial benefit. Assessing mechanical dyssynchrony may improve patient selection. Results from studies using echocardiographic imaging to measure dyssynchrony have ultimately proved disappointing. We sought to evaluate cardiac motion in patients with heart failure and electrical dyssynchrony using cardiovascular magnetic resonance (CMR). We developed a framework for comparing measures of myocardial mechanics and evaluated how well they predicted response to CRT. METHODS: CMR was performed at 1.5 Tesla prior to CRT. Steady-state free precession (SSFP) cine images and complementary modulation of magnetization (CSPAMM) tagged cine images were acquired. Images were processed using a novel framework to extract regional ventricular volume-change, thickening and deformation fields (strain). A systolic dyssynchrony index (SDI) for all parameters within a 16-segment model of the ventricle was computed with high SDI denoting more dyssynchrony. Once identified, the optimal measure was applied to a second patient population to determine its utility as a predictor of CRT response compared to current accepted predictors (QRS duration, LBBB morphology and scar burden). RESULTS: Forty-four patients were recruited in the first phase (91% male, 63.3 ± 14.1 years; 80% NYHA class III) with mean QRSd 154 ± 24 ms. Twenty-one out of 44 (48%) patients showed reverse remodelling (RR) with a decrease in end systolic volume (ESV) ≥ 15% at 6 months. Volume-change SDI was the strongest predictor of RR (PR 5.67; 95% CI 1.95-16.5; P = 0.003). SDI derived from myocardial strain was least predictive. Volume-change SDI was applied as a predictor of RR to a second population of 50 patients (70% male, mean age 68.6 ± 12.2 years, 76% NYHA class III) with mean QRSd 146 ± 21 ms. When compared to QRSd, LBBB morphology and scar burden, volume-change SDI was the only statistically significant predictor of RR in this group. CONCLUSION: A systolic dyssynchrony index derived from volume-change is a highly reproducible measurement that can be derived from routinely acquired SSFP cine images and predicts RR following CRT whilst an SDI of regional strain does not.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Imagem Cinética por Ressonância Magnética , Disfunção Ventricular Esquerda/diagnóstico , Disfunção Ventricular Esquerda/terapia , Função Ventricular Esquerda , Idoso , Idoso de 80 Anos ou mais , Fenômenos Biomecânicos , Feminino , Insuficiência Cardíaca/fisiopatologia , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Contração Miocárdica , Seleção de Pacientes , Valor Preditivo dos Testes , Estudos Prospectivos , Recuperação de Função Fisiológica , Reprodutibilidade dos Testes , Fatores de Tempo , Resultado do Tratamento , Disfunção Ventricular Esquerda/fisiopatologia , Remodelação Ventricular
10.
Europace ; 16(6): 873-9, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24525553

RESUMO

AIMS: Alternative forms of cardiac resynchronization therapy (CRT), including biventricular endocardial (BV-Endo) and multisite epicardial pacing (MSP), have been developed to improve response. It is unclear which form of stimulation is optimal. We aimed to compare the acute haemodynamic response (AHR) and electrophysiological effects of BV-Endo with MSP via two separate coronary sinus (CS) leads or a single-quadripolar CS lead. METHODS AND RESULTS: Fifteen patients with a previously implanted CRT system received a second temporary CS lead and left ventricular (LV) endocardial catheter. A pressure wire and non-contact mapping array were placed into the LV cavity to measure LVdP/dtmax and perform electroanatomical mapping. Conventional CRT, BV-Endo, and MSP were then performed (MSP-1 via two epicardial leads and MSP-2 via a single-quadripolar lead). The best overall AHR was found using BV-Endo pacing with a 19.6 ± 13.6% increase in AHR at the optimal endocardial site over baseline (P < 0.001). There was an increase in LVdP/dtmax with MSP-1 and MSP-2 compared with conventional CRT, but this was not statistically significant. Biventricular endocardial pacing from the optimal site was significantly superior to conventional CRT (P = 0.039). The AHR achieved when BV-Endo pacing was highly site specific. Within individuals, the best pacing modality varied and was affected by the underlying substrate. Left ventricular activation times did not predict the optimal haemodynamic configuration. CONCLUSION: Biventricular endocardial pacing and not MSP was superior to conventional CRT, but was highly site specific. Within individuals, however, different methods of stimulation are optimal and may need to be tailored to the underlying substrate.


Assuntos
Mapeamento Potencial de Superfície Corporal/métodos , Terapia de Ressincronização Cardíaca/métodos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/prevenção & controle , Volume Sistólico , Disfunção Ventricular Esquerda/diagnóstico , Terapia de Ressincronização Cardíaca/classificação , Insuficiência Cardíaca/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento , Disfunção Ventricular Esquerda/fisiopatologia , Disfunção Ventricular Esquerda/prevenção & controle
11.
J Card Fail ; 19(11): 731-8, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24263116

RESUMO

BACKGROUND: A novel quadripolar left ventricular (LV) pacing lead has the ability to deliver multisite LV pacing (MSLV). We set out to characterize the safety and changes in acute mechanical dyssynchrony with MSLV in cardiac resynchronization therapy (CRT) patients. METHODS AND RESULTS: Prospective multicenter study in 52 patients receiving CRT. An acute pacing protocol comprising 8 MSLV configurations covering a range of delays was compared with conventional CRT (baseline). Transthoracic tissue Doppler imaging (TDI) was used to measure the standard deviation of time to peak contraction of 12 LV segments (Ts-SD) and delayed longitudinal contraction. No ventricular arrhythmia occurred in any of the 52 patients. Complete TDI datasets were collected in 41 patients. Compared with baseline: 1) The mean Ts-SD was significantly lower for the optimal MSLV configuration (35.3 ± 36.4 vs 50.2 ± 29.1 ms; P < .001); 2) at least 1 MSLV configuration exhibited a significant dyssynchrony improvement in 63% of patients; and 3) the mean number of LV segments with delayed longitudinal contractions was significantly reduced with the optimal MSLV configuration (0.37 ± 7.99 vs 2.20 ± 0.19; P < .001). CONCLUSIONS: Acute MSLV was acutely safe, and a proportion of MSLV vectors resulted in a significant reduction in echocardiographic dyssynchrony compared with conventional CRT.


Assuntos
Terapia de Ressincronização Cardíaca/métodos , Isquemia Miocárdica/fisiopatologia , Isquemia Miocárdica/terapia , Disfunção Ventricular Esquerda/fisiopatologia , Disfunção Ventricular Esquerda/terapia , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/diagnóstico , Estudos Prospectivos , Fatores de Tempo , Resultado do Tratamento , Disfunção Ventricular Esquerda/diagnóstico , Função Ventricular Esquerda/fisiologia
12.
Pacing Clin Electrophysiol ; 36(2): e48-50, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22126629

RESUMO

Pacing the left ventricle (LV) from multiple sites simultaneously may result in a better response to cardiac resynchronization therapy (CRT). We sought to assess whether multisite pacing using a quadripolar LV lead improves acute hemodynamic response (AHR) to CRT. We paced four ventricular sites simultaneously using two vectors of a Quartet lead, a right ventricular apical lead, and an additional LV lead temporarily placed in an anterior branch of the coronary sinus. Multisite pacing using the Quartet lead alone did not improve the AHR but "quad-site" pacing using an additional temporary LV lead did increase dP/dt(max).


Assuntos
Eletrodos Implantados , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/prevenção & controle , Marca-Passo Artificial , Disfunção Ventricular Esquerda/complicações , Disfunção Ventricular Esquerda/prevenção & controle , Idoso , Insuficiência Cardíaca/diagnóstico , Humanos , Masculino , Resultado do Tratamento , Disfunção Ventricular Esquerda/diagnóstico
13.
Europace ; 14(3): 373-9, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22045930

RESUMO

AIMS: Multi-site left ventricular (LV) pacing may be superior to single-site stimulation in correcting dyssynchrony and avoiding areas of myocardial scar. We sought to characterize myocardial scar using cardiac magnetic resonance imaging (CMR). We aimed to quantify the acute haemodynamic response to single-site and multi-site LV stimulation and to relate this to the position of the LV leads in relation to myocardial scar. METHODS: Twenty patients undergoing cardiac resynchronization therapy had implantation of two LV leads. One lead (LV1) was positioned in a postero-lateral vein, the second (LV2) in a separate coronary vein. LV dP/dtmax was recorded using a pressure wire during stimulation at LV1, LV2, and both sites simultaneously (LV1 + 2). Patients were deemed acute responders if ΔLV dP/dtmax was ≥ 10%. Cardiac magnetic resonance imaging was performed to assess dyssynchrony as well as location and burden of scar. Scar anatomy was registered with fluoroscopy to assess LV lead position in relation to scar. RESULTS: LV dP/dtmax increased from 726 ± 161 mmHg/s in intrinsic rhythm to 912 ± 234 mmHg/s with LV1, 837 ± 188 mmHg/s with LV2, and 932 ± 201 mmHg/s with LV1 and LV2. Nine of 19 (47%) were acute responders with LV1 vs. 6/19 (32%) with LV2. Twelve of 19 (63%) were acute responders with simultaneous LV1 + 2. Two of three patients benefitting with multi-site pacing had the LV1 lead positioned in postero-lateral scar. CONCLUSION: Multi-site LV pacing increased acute response by 16% vs. single-site pacing. This was particularly beneficial in patients with postero-lateral scar identified on CMR.


Assuntos
Estimulação Cardíaca Artificial/métodos , Insuficiência Cardíaca/terapia , Hemodinâmica/fisiologia , Imageamento por Ressonância Magnética , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Disfunção Ventricular Esquerda/fisiopatologia , Disfunção Ventricular Esquerda/terapia
14.
Pacing Clin Electrophysiol ; 35(2): 196-203, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22126664

RESUMO

BACKGROUND: It is not clear whether there is a large difference in acute hemodynamic response (AHR) to left ventricle (LV) pacing in different regions of the same coronary sinus (CS) vein. Using the four electrodes available on a Quartet LV lead, we evaluated the AHR to pacing within individual branches of the CS. METHODS: An acute hemodynamic study was attempted in 20 patients. In each patient, we assessed AHR in a number of CS veins and along a significant proportion of each CS branch using three different bipolar configurations. We compared the AHR achieved when pacing using each different vector and also the highest AHR achieved in any position within the same patient with the lowest achieved in that patient. RESULTS: Sixty-four different CS positions in 19 patients were successfully assessed. No significant difference in AHR was found overall between the three vectors tested. The mean percentage difference in AHR between the CS branch vectors with the lowest and highest dP/dt(max) was +6.5 ± 5.4% (P < 0.001). A much larger difference of +16.9 ± 6.1% (P < 0.001) was seen when comparing the highest and lowest AHR achieved using any vector in any position within the same patient. CONCLUSION: A small difference in AHR is seen when pacing within the same branch of the CS compared to pacing in different branches in the same patient. This suggests that although the site of LV lead placement is important, the position within a CS branch is less important than choosing the right vein.


Assuntos
Estimulação Cardíaca Artificial/métodos , Circulação Coronária , Seio Coronário/fisiopatologia , Sistema de Condução Cardíaco/fisiopatologia , Disfunção Ventricular Esquerda/prevenção & controle , Disfunção Ventricular Esquerda/fisiopatologia , Idoso de 80 Anos ou mais , Velocidade do Fluxo Sanguíneo , Eletrodos Implantados , Feminino , Humanos , Masculino
15.
Pacing Clin Electrophysiol ; 35(7): 841-9, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22519516

RESUMO

BACKGROUND: As the population receiving cardiac device therapy ages, the number of extraction procedures performed in octogenarians is increasing. This group has more comorbidities and may be at higher risk of such procedures. OBJECTIVES: Document the safety and success of percutaneous lead extraction in octogenarians. METHODS: All extraction cases performed between January 2001 and April 2011 entered into a computer database were analyzed for patient characteristics and indications, extraction technique, procedural success, and complications. Success and complications were classified according to the Heart Rhythm Society consensus statement. Outcomes in octogenarians were compared to younger patients undergoing extraction during the same period. RESULTS: Four hundred and six cases were performed: 72 procedures in octogenarians (mean age 84, range 80-95) and 334 in younger adults (mean age 62, range 20-79). Octogenarians had a greater number of comorbidities per case. Infection was the commonest indication for extraction in both groups. One hundred forty-one leads were extracted in octogenarians and 657 in younger patients. Laser assistance was required in 51.4% of octogenarians versus 49.7% of younger patients. Procedural success was achieved in 71/72 (98.6%) octogenarians versus 329/334 (98.5%) younger patients. No procedural mortality occurred in either group. Overall, complications were more frequent in octogenarians with major and minor complications occurring in 2.8 and 8.3% of octogenarians versus 0.6 and 3.0% of younger patients (P = 0.014). CONCLUSIONS: Procedural success was equally high in octogenarians and younger patients. Percutaneous lead extraction can be performed effectively and safely in octogenarians and is associated with a higher complication rate but no increased mortality.


Assuntos
Desfibriladores Implantáveis/estatística & dados numéricos , Remoção de Dispositivo/mortalidade , Procedimentos Cirúrgicos Minimamente Invasivos/mortalidade , Marca-Passo Artificial/estatística & dados numéricos , Complicações Pós-Operatórias/mortalidade , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prevalência , Análise de Sobrevida , Taxa de Sobrevida , Resultado do Tratamento , Reino Unido/epidemiologia
16.
J Food Sci Technol ; 49(5): 530-6, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24082263

RESUMO

With excellent quality and flavour of fresh fruits, young leaves of cactus serve as nutritious vegetable and salad dish and the immature fruits for making mock-gherkins. Cactus, with high water use efficiency produce forage for animals, vegetables, and fruits with 14% glucose. Traditionally cactus used as a valuable health supporting nutrient and it also has applications in pharmaceutical industries. Cactus with number of uses has immense potential to be the food of future.

17.
Europace ; 13(4): 590-1, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20974758

RESUMO

We describe cardiac resynchronization therapy in a patient with a mitral valve annuloplasty device in situ for functional mitral regurgitation. We successfully implanted a left ventricular lead through a mitral valve annuloplasty device anchor into the coronary sinus and then through the struts of the device's proximal anchor.


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca , Eletrodos Implantados , Bloqueio Cardíaco/terapia , Ventrículos do Coração , Anuloplastia da Valva Mitral/instrumentação , Disfunção Ventricular Esquerda/terapia , Terapia de Ressincronização Cardíaca/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Insuficiência da Valva Mitral/cirurgia , Resultado do Tratamento
18.
Europace ; 13(7): 992-6, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21343237

RESUMO

AIMS: Problems with implanting a left ventricular (LV) lead during cardiac resynchronization therapy (CRT) procedures are not uncommon and may occur for a variety of reasons including phrenic nerve stimulation (PNS) and high capture thresholds. We aimed to perform successful CRT in patients with previous LV lead problems using the multiple pacing configurations available with the St Jude Quartet model 1458Q quadripolar LV lead to overcome PNS or high capture thresholds. METHODS AND RESULTS: Four patients with previous failed attempts at LV lead implantation underwent a further attempt at CRT using a Quartet lead. In all four cases, successful CRT was achieved using a Quartet lead placed in a branch of the coronary sinus. Problems with PNS or high capture thresholds were seen in all four patients but were successfully overcome. Satisfactory lead parameters were seen at implant, pre-discharge, and at short-term follow-up (8.5±5 weeks). CONCLUSION: The Quartet lead allows 10 different pacing vectors to be used and may overcome common pacing problems because of the multiple pacing configurations available. Problems with either PNS or unsatisfactory pacing parameters experienced during CRT may be resolved simply by changing the pacing configuration using this quadripolar lead system.


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca , Terapia de Ressincronização Cardíaca/métodos , Cardiomiopatias/fisiopatologia , Cardiomiopatias/terapia , Ventrículos do Coração/fisiopatologia , Adulto , Idoso , Seio Coronário/fisiopatologia , Eletrodos Implantados , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Nervo Frênico/fisiopatologia , Falha de Tratamento , Resultado do Tratamento
19.
Pacing Clin Electrophysiol ; 34(4): 484-9, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21208241

RESUMO

BACKGROUND: The Quartet model 1458Q (St. Jude Medical, Sylmar, CA, USA) lead is a quadripolar left ventricular (LV) lead with pace/sense capability from four electrodes (tip and three rings). The lead is capable of pacing in 10 different configurations rather than the three that are available in conventional bipolar pacing leads. We describe a single-center initial experience of the use of this lead in patients undergoing cardiac resynchronization therapy (CRT). METHODS: Twenty-eight patients for a CRT with cardiac defibrillator were implanted between October 2009 and May 2010 with a Quartet lead . Lead position, pacing parameters, stability, complications, and presence of phrenic nerve stimulation (PNS) data were collected at implant and predischarge. Follow-up data were collected at 15 ± 8 weeks for all patients. RESULTS: A Quartet lead was successfully implanted in 96% (27/28) of patients (age 61 ± 15 years; 82% male; ischemic etiology 50%; mean left ventricular [LV] ejection fraction 25 ± 7%; left bundle branch block 68%). PNS was seen at implant in 11 patients (41%) with at least one vector. In eight of these cases (72%), the need for lead repositioning was averted by programming LV pacing utilizing the additional vectors available with the Quartet lead. CONCLUSION: These initial data suggest that pacing with the Quartet lead is associated with a high implant success rate and stable pacing parameters acutely and at short-term follow-up. The 10 LV pacing vectors available with this lead may allow PNS and capture threshold problems to be easily overcome.


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca , Eletrodos Implantados , Desenho de Equipamento , Análise de Falha de Equipamento , Feminino , Insuficiência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Resultado do Tratamento
20.
Pacing Clin Electrophysiol ; 34(2): 226-34, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21029135

RESUMO

BACKGROUND: Failure rate for left ventricular (LV) lead implantation in cardiac resynchronization therapy (CRT) is up to 12%. The use of segmentation tools, advanced image registration software, and high-fidelity images from computerized tomography (CT) and cardiac magnetic resonance (CMR) of the coronary sinus (CS) can guide LV lead implantation. We evaluated the feasibility of advanced image registration onto live fluoroscopic images to allow successful LV lead placement. METHODS: Twelve patients (11 male, 59 ± 16.8 years) undergoing CRT had three-dimensional (3D) whole-heart imaging (six CT, six CMR). Eight patients had at least one previously failed LV lead implant. Using segmentation software, anatomical models of the cardiac chambers, CS, and its branches were overlaid onto the live fluoroscopy using a prototype version of the Philips EP Navigator software to guide lead implantation. RESULTS: We achieved high-fidelity segmentations of cardiac chambers, coronary vein anatomy, and accurate registration between the 3D anatomical models and the live fluoroscopy in all 12 patients confirmed by balloon occlusion angiography. The CS was cannulated successfully in every patient and in 11, an LV lead was implanted successfully. (One patient had no acceptable lead values due to extensive myocardial scar). CONCLUSION: Using overlaid 3D segmentations of the CS and cardiac chambers, it is feasible to guide CRT implantation in real time by fusing advanced imaging and fluoroscopy. This enabled successful CRT in a group of patients with previously failed implants. This technology has the potential to facilitate CRT and improve implant success.


Assuntos
Terapia de Ressincronização Cardíaca , Seio Coronário/diagnóstico por imagem , Seio Coronário/patologia , Eletrodos Implantados , Ventrículos do Coração/cirurgia , Imagem Cinética por Ressonância Magnética/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Terapia de Ressincronização Cardíaca/métodos , Dispositivos de Terapia de Ressincronização Cardíaca , Feminino , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/patologia , Humanos , Masculino , Implantação de Prótese/métodos , Cirurgia Assistida por Computador
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA