Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 65
Filtrar
1.
Int Endod J ; 56(6): 765-774, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36825362

RESUMO

AIM: To evaluate the efficacy of a novel ultrasonic irrigation device, remotely-generated irrigation with a non-invasive sound field enhancement (RINSE) system, in removing biofilm-mimicking hydrogel from a simulated isthmus model and compare it with sonically- and ultrasonically-activated irrigation systems. METHODOLOGY: A polycarbonate root canal model containing two standardized root canals (apical diameter of 0.20 mm, 4% taper, 18 mm long with a coronal reservoir) connected by three isthmuses (0.40 mm deep, 2 mm high, 4 mm long) was used as the test model. The isthmuses were filled with a hydroxyapatite powder-containing hydrogel. The canals were filled with irrigant, and the models were randomly assigned to the following activation groups (n = 15): EndoActivator (EA), ultrasonically activated irrigation (UAI), and RINSE system (RS). Syringe irrigation (SI) with a 30G needle served as the control. Standardized images of the isthmuses were taken before and after irrigation, and the amount of hydrogel removed was determined using image analysis software and compared across groups using anova (p < .05). RESULTS: Hydrogel removal was significantly higher with the RS (83.7%) than with UAI, EA, or SI (p ≤ .01). UAI (69.2%) removed significantly more hydrogel than SI and EA (p < .05), while there was no significant difference between SI (24.3%) and EA (25.7%) (p = .978). CONCLUSIONS: RINSE system resulted in the most hydrogel removal, performing better than UAI or EA. The effect of RS was also not reliant on the insert or tip entering the pulp chamber or root canal, making it particularly useful in conservative endodontics.


Assuntos
Cavidade Pulpar , Tratamento do Canal Radicular , Ondas Ultrassônicas , Biofilmes/efeitos da radiação , Cavidade Pulpar/microbiologia , Cavidade Pulpar/efeitos da radiação , Hidrogéis , Irrigantes do Canal Radicular , Preparo de Canal Radicular , Hipoclorito de Sódio , Irrigação Terapêutica/métodos , Modelos Anatômicos , Tratamento do Canal Radicular/instrumentação , Tratamento do Canal Radicular/métodos
2.
Odontology ; 109(2): 411-421, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32980911

RESUMO

This retrospective study investigated the effect of mineral trioxide aggregate (MTA) plug location on treatment outcome and root maturation after regenerative endodontic procedures (REP) in immature permanent teeth. Thirty-three roots (n = 33) in cohort that underwent REP consistently according to AAE guideline were included to trace radiographic changes for the root and canal dimensions. Based on intraoral radiographs, roots were divided into two groups depending on the location of MTA plug within whole root length: coronal group (n = 14), within the upper half; apical group (n = 19), within the lower half. Periapical radiographs were standardized to assess treatment outcomes and root maturation including root development stages and digital measurements on the change ratios of root length, apex width, radiographic root area (RRA), modified RRA (mRRA), and periapical rarefaction area. The data were statistically analysed using the Mann-Whitney test. The patients' average age was 11 years and 10 months, with no significant between-group difference in sex. Premolars were the most prevalent tooth type (62.1%), followed by incisiors and molars. Pre-existing symptoms and signs subsided within 6 months in all cases. The teeth showed similar radiographic root development in both groups (P > 0.05). However, mRRA increase ratio was significantly higher in apical group than that in coronal group at early (< 6 months) and late (< 24 months) periods of follow-up (P < 0.05). Significant changes of root development stage were observed at early period for apical group and at late period for coronal group (P < 0.05). All the observed cases showed continuing root development after REP. Significant changes in root developments occurred at different follow-up periods according to the location of MTA plugs.


Assuntos
Endodontia Regenerativa , Materiais Restauradores do Canal Radicular , Compostos de Alumínio , Compostos de Cálcio , Criança , Combinação de Medicamentos , Humanos , Óxidos , Estudos Retrospectivos , Silicatos , Ápice Dentário/diagnóstico por imagem
3.
Clin Oral Investig ; 24(11): 3863-3870, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32170546

RESUMO

OBJECTIVES: To obtain radicular measurements of two separate mesiobuccal (MB) root canals in maxillary first molars using micro-computed tomography (µCT) with customized software. MATERIALS AND METHODS: Human maxillary first molar MB roots (N = 36) with two separate canals (MB1, MB2) and apical foramina were scanned by µCT and analyzed with Kappa2 software to reconstruct three-dimensional (3D) surface models of roots and canals. These models were sectioned at 0.1 mm intervals perpendicular to the central axis of each canal. Canal widths, 3D curvatures, and surrounding dentine thicknesses were measured concurrently on each section. Dentine thicknesses were analyzed statistically for differences between each direction and the different levels of both canals. RESULTS: Dentine walls around MB1 were thicker than MB2 (p < 0.05). Thinnest dentine was most often located at disto-inside direction in both canals. Canal widths were significantly smaller in MB2 than MB1 (p < 0.01). Apical constrictions were smaller (p < 0.05) and further (p < 0.05) from the apex in MB2 than MB1. Canal curvatures were greatest in the apical third of both canals (p < 0.001), and they were greater in MB2 than MB1 (p < 0.05). CONCLUSIONS: MB2 canals had shorter lengths, smaller widths, and more severe curvatures and were surrounded by thinner dentine walls. In MB2, apical constrictions were between 1 and 2 mm from the apex, compared to about 1 mm for MB1. CLINICAL RELEVANCE: These detailed measurements and in-depth 3D analyses of maxillary first molar MB roots with two separate canals and apical foramina provide morphologic references for root canal therapy.


Assuntos
Cavidade Pulpar , Maxila , Cavidade Pulpar/diagnóstico por imagem , Humanos , Maxila/diagnóstico por imagem , Dente Molar/diagnóstico por imagem , Raiz Dentária/diagnóstico por imagem , Microtomografia por Raio-X
4.
Medicina (Kaunas) ; 56(11)2020 Nov 16.
Artigo em Inglês | MEDLINE | ID: mdl-33207656

RESUMO

The complete removal of obturation material can be a challenge in nonsurgical root canal retreatment. The insufficient removal of obturation material is a reason for root canal retreatment failure. The purpose of this study was to assess the efficacy of different final root canal irrigation activation methods in removing debris and smear layers in the apical and middle portions of root canals during retreatment. Sixty-six distal roots of freshly extracted molars were randomly divided into six groups: (1) primary root canal treatment with no obturation (negative control); (2) retreatment with only conventional instrumentation and irrigation (positive control); (3) retreatment with additional ultrasonic irrigation using the Piezon Master 700; (4) ultrasonic irrigation with the ENDOSONIC Blue; (5) sonic irrigation with the EDDY; and (6) multisonic irrigation with the GentleWave system. Roots were split and prepared for scanning electron microscopic (SEM) evaluation. Acquired images were assessed to quantify the amount of debris and smear remaining. Among the treatment groups, Group 6 had a significantly lower debris score than Group 2 (positive control) in both the middle and apical regions (p = 0.004, p = 0.012). All treatment groups showed significantly lower smear scores than Group 2 in the middle and apical regions (p < 0.05). The GentleWave multisonic System showed a more optimal cleaning efficacy of the root canal debris but did not differ significantly with the tested passive ultrasonic or sonic irrigation method.


Assuntos
Camada de Esfregaço , Cavidade Pulpar , Humanos , Retratamento , Irrigantes do Canal Radicular , Preparo de Canal Radicular
5.
BMC Oral Health ; 17(1): 110, 2017 Jul 11.
Artigo em Inglês | MEDLINE | ID: mdl-28697771

RESUMO

BACKGROUND: Although many studies have compared the properties of ultrasonic scaling instruments, it remains controversial as to which is most suitable for implant scaling. This study evaluated the safety and efficiency of novel metallic ultrasonic scaler tips made by the powder injection molding (PIM) technique on titanium surfaces. METHODS: Mechanical instrumentation was carried out using four types of metal scaler tips consisting of copper (CU), bronze (BR), 316 L stainless steel (316 L), and conventional stainless steel (SS) tips. The instrumented surface alteration image of samples was viewed with scanning electron microscope (SEM) and surface profile of the each sample was investigated with confocal laser scanning microscopy (CLSM). Arithmetic mean roughness (Ra) and maximum height roughness (Rmax) of titanium samples were measured and dissipated power of the scaler tip was estimated for scaling efficiency. RESULTS: The average Ra values caused by the 316 L and SS tip were about two times higher than those of the CU and BR tips (p < 0.05). The Rmax value showed similar results. The efficiency of the SS tip was about 3 times higher than that of CU tip, the 316 L tip is about 2.7 times higher than that of CU tip, and the BR tip is about 1.2 times higher than that of CU tip. CONCLUSIONS: Novel metallic bronze alloy ultrasonic scaler tip minimally damages titanium surfaces, similar to copper alloy tip. Therefore, this bronze alloy scaler tip may be promising instrument for implant maintenance therapy.


Assuntos
Implantes Dentários , Planejamento de Prótese Dentária/métodos , Planejamento de Prótese Dentária/instrumentação , Humanos , Microscopia Confocal , Microscopia Eletrônica de Varredura , Propriedades de Superfície , Titânio , Ultrassom
6.
Acta Odontol Scand ; 74(5): 411-5, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27140658

RESUMO

OBJECTIVE: Evaluation of pulp vitality is an important diagnostic procedure in dentistry. Conventional techniques for measurement of pulp vitality, including thermal stimulation, electrical stimulation, or direct dentin stimulation, are frequently associated with false positive or false negative results. Recently, oxygen saturation from pulse oximetry has been utilized in the evaluation of pulp vitality. Perfusion index (PI) data calculated from photoplethysmography have been widely used to evaluate peripheral perfusion. The combination of oxygen saturation and PI may aid in the accurate measurement of pulp vitality. We aimed to investigate the baseline values of oxygen saturation and PI using pulse oximetry in adult volunteers. MATERIAL AND METHODS: Fifteen adult volunteers with viable incisors were tested. To measure PI, a fabricated oxygen sensor was applied to an incisor without a pulp lesion while oxygen saturation was simultaneously measured in the finger. Oxygen saturation and PI were continuously measured with customized software. The normal reference values of oxygen saturation and PI were obtained by analyzing the recorded data. RESULTS: Pulse oximetry showed relatively stable, objective, and accurate oxygen saturation results. The tooth oxygen saturation ranged from 97% to 100%. The PI ranged from 0.3% to 0.5%, and PI and oxygen saturation showed relatively consistent values across subjects. CONCLUSIONS: Although there are some limitations to our study, these results may prove useful for detecting teeth with impaired vitality and non-invasively differentiating between necrotic and vital pulp.


Assuntos
Teste da Polpa Dentária/métodos , Polpa Dentária/irrigação sanguínea , Incisivo/irrigação sanguínea , Oximetria/métodos , Adulto , Temperatura Baixa , Teste da Polpa Dentária/instrumentação , Estimulação Elétrica/métodos , Humanos , Oximetria/instrumentação , Oxigênio/sangue , Fotopletismografia/métodos , Valores de Referência , Fluxo Sanguíneo Regional/fisiologia , Dente não Vital/fisiopatologia , Adulto Jovem
7.
J Calif Dent Assoc ; 44(5): 278-90, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-27290822

RESUMO

Vital pulp therapy (VPT) is devised to preserve and maintain vitality of pulpally involved teeth challenged by a variety of intraoral conditions. Notable progress has been made in this field due to a better understanding of pulp physiology, improved clinical protocols and advanced bioceramic materials paired with adhesive technology. With focused case selection, conservative VPT can provide reliable treatment options for permanent teeth diagnosed with normal pulps or reversible pulpitis.


Assuntos
Materiais Biocompatíveis/química , Cerâmica/química , Capeamento da Polpa Dentária/tendências , Pulpotomia/métodos , Humanos , Agentes de Capeamento da Polpa Dentária e Pulpectomia/uso terapêutico , Pulpite/terapia
8.
Mediators Inflamm ; 2015: 385127, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26604431

RESUMO

Porphyromonas gingivalis is considered with inducing pulpal inflammation and has lipopolysaccharide (LPS) as an inflammatory stimulator. GV1001 peptide has anticancer and anti-inflammation activity due to inhibiting activation of signaling molecules after penetration into the various types of cells. Therefore, this study examined inhibitory effect of GV1001 on dental pulp cells (hDPCs) stimulated by P. gingivalis LPS. The intracellular distribution of GV1001 was analyzed by confocal microscopy. Real-time RT-PCR was performed to determine the expression levels of TNF-α and IL-6 cytokines. The role of signaling by MAP kinases (ERK and p38) was explored using Western blot analysis. The effect of GV1001 peptide on hDPCs viability was measured by MTT assay. GV1001 was predominantly located in hDPC cytoplasm. The peptide inhibited P. gingivalis LPS-induced TNF-α and IL-6 production in hDPCs without significant cytotoxicity. Furthermore, GV1001 treatment markedly inhibited the phosphorylation of MAP kinases (ERK and p38) in LPS-stimulated hDPCs. GV1001 may prevent P. gingivalis LPS-induced inflammation of apical tissue. Also, these findings provide mechanistic insight into how GV1001 peptide causes anti-inflammatory actions in LPS-stimulated pulpitis without significantly affecting cell viability.


Assuntos
Anti-Inflamatórios/farmacologia , Citocinas/biossíntese , Polpa Dentária/imunologia , Lipopolissacarídeos/farmacologia , Fragmentos de Peptídeos/farmacologia , Porphyromonas gingivalis/patogenicidade , Telomerase/farmacologia , Adolescente , Adulto , Polpa Dentária/citologia , MAP Quinases Reguladas por Sinal Extracelular/antagonistas & inibidores , Humanos , Interleucina-6/biossíntese , Telomerase/metabolismo , Receptores Toll-Like/fisiologia , Fator de Necrose Tumoral alfa/biossíntese , Proteínas Quinases p38 Ativadas por Mitógeno/antagonistas & inibidores
9.
Implant Dent ; 24(3): 287-93, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25902367

RESUMO

PURPOSE: The aim of this study was to evaluate and compare the osseointegration of zirconia implants in rabbit tibiae with and without 10-methacryloyloxydecyl dihydrogen phosphate (MDP) treatment. MATERIALS AND METHODS: Twenty-eight rabbits received a total of 112 external hex-type implants made by the powder injection molding technique with and without MDP treatment before installation in the tibiae. The contact angles on the zirconia implants and zirconia discs before and after MDP application were evaluated. Removal torque (RT) and bone-implant contact (BIC) ratios were measured. RESULTS: The MDP treatment markedly enhanced the hydrophilicity and seemed to alter the topography and chemical composition of the implant and disc surface. As the healing time increases, the BIC and RT were increased in both groups. The MDP-treated implants exhibited higher BIC values than the control implants after 2 and 4 weeks of healing. The RT was higher in MDP-treated implants after 2 weeks of healing but not after 4 weeks of healing. CONCLUSION: The 10-MDP treatments made the surface more hydrophilic and enhanced the osseointegration of the implants in the early healing phase.


Assuntos
Implantação Dentária Endóssea/métodos , Implantes Dentários , Metacrilatos/uso terapêutico , Osseointegração , Tíbia/cirurgia , Animais , Análise do Estresse Dentário , Masculino , Microscopia Eletrônica de Varredura , Coelhos , Fatores de Tempo , Zircônio
10.
BMC Oral Health ; 15(1): 129, 2015 Oct 21.
Artigo em Inglês | MEDLINE | ID: mdl-26490372

RESUMO

BACKGROUND: The aim of this study was to investigate the physical properties and biological effects of an experimentally developed injectable premixed calcium-silicate root canal sealer (Endoseal) in comparison with mineral trioxide aggregate (MTA) and a resin-based sealer (AHplus). METHODS: The pH, solubility, dimensional change, flow, and radiopacity of the materials were evaluated. Biocompatibility was evaluated on the basis of cell morphology and a viability test using MC3T3-E1 cells. For evaluate inflammatory reaction, the tested sealers were implanted into dorsal subcutaneous connective tissue of Sprague Dawley rats. After 7 days, the implants with the surrounding tissue were retrieved, and histological evaluation was performed. RESULTS: Endoseal showed high alkalinity similar to that of MTA. The solubility of the tested materials was similar. The dimensional change and flow of Endoseal was significantly higher than that of other materials (P < 0.05). The radiopacity of Endoseal was lower than that of AHplus (P < 0.05). The biocompatibility was similar to those of MTA. Inflammatory reaction of Endoseal was similar with that of MTA, but lower than that of AHplus (P < 0.05). CONCLUSIONS: The present study indicates that Endoseal has favorable physical properties and biocompatibility. Therefore, we suggest that Endoseal has the potential to be used as a predictable root canal sealer.


Assuntos
Cálcio , Cavidade Pulpar , Materiais Restauradores do Canal Radicular , Silicatos , Compostos de Alumínio , Animais , Compostos de Cálcio , Combinação de Medicamentos , Teste de Materiais , Óxidos , Ratos , Ratos Sprague-Dawley , Solubilidade , Cimento de Óxido de Zinco e Eugenol
11.
Clin Oral Implants Res ; 25(5): 573-9, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-23406227

RESUMO

OBJECTIVES: The aim of this study was to evaluate and compare the osseointegration of powder-injection molded (PIM) zirconia implants in rabbit tibiae with or without He plasma treatment. MATERIAL AND METHODS: Twenty-five rabbits received 4 types of external hex implants with identical geometry in the tibiae: PIM zirconia implants, roughened PIM zirconia implants, plasma-treated PIM zirconia implants, and plasma-treated roughened PIM zirconia implants. The contact angles of the four types of implants were evaluated. Removal torque tests and histomorphometric analyses were performed. RESULTS: The plasma treatment markedly enhanced the hydrophilicity, but did not seem to change the surface topography of the PIM zirconia implants. There were statistically significant differences in the bone-to-implant contact (BIC) ratios, bone volume (BV/TV), and removal torque values (RTQ) among the tested implant types (P < 0.001). The plasma-treated implants exhibited significantly higher BIC and BV/TV values than the untreated implants. However, the removal torque values favored the rough surface. CONCLUSIONS: The He plasma treatments on PIM zirconia implants made the surface more hydrophilic and enhanced the osseointegration of the implants without changing the micro-topography.


Assuntos
Implantes Dentários , Osseointegração/fisiologia , Tíbia/cirurgia , Animais , Pressão Atmosférica , Planejamento de Prótese Dentária , Remoção de Dispositivo , Hélio , Implantes Experimentais , Masculino , Microscopia Eletrônica de Varredura , Gases em Plasma , Coelhos , Propriedades de Superfície , Torque , Zircônio
12.
J Mech Behav Biomed Mater ; 150: 106156, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38041883

RESUMO

INTRODUCTION: To develop a calcium silicate (CaSi)-based cement containing dimethyl sulfoxide (DMSO) and cement deliver device for new root canal filling technique, and to assess the flow behavior, leakage, and root canal filling quality of CaSi containing DMSO. METHODS: CaSi containing DMSO (CSC-DMSO) and CaSi containing PEG (CSC-PEG) were prepared, and the flow characteristics of both cements were compared in gypsum and resin channels using a high-speed camera. Eight root canals were obturated by CSC-DMSO or CSC-PEG using a cement delivery device, and root canal filling quality was assessed in terms of filling length using periapical radiographs. The filling length was evaluated by 'apico-coronal extension,' measuring length in reference to apical constriction. Microleakage was measured for thirty human molars that were randomly filled with CSC-DMSO, CSC-PEG, or gutta-percha and AH plus. Preliminary obturation of CSC-DMSO with cement delivery device in human teeth was analyzed in terms of filling length and void, using periapical radiographs. Statistical analysis was performed with the Kruskal Wallis test for simulated root canal fillings and one-way ANOVA for leakage test. RESULTS: The flow speed of CSC-DMSO reduced in gypsum channels compared to resin channels, but CSC-PEG did not exhibit significant differences in the channels. The median absolute value of apico-coronal extension was significantly lower in CSC-DMSO compared to CSC-PEG (p < 0.05). Microleakage did not statistically differ between the groups (p > 0.05). In the preliminary obturation, the mean apico-coronal extension of CSC-DMSO was -0.297 ± 0.724 mm, while CSC-PEG was not feasible due to excess apical extrusions. CONCLUSIONS: CSC-DMSO could be considered as an alternative filling material for root canal obturation.


Assuntos
Materiais Restauradores do Canal Radicular , Humanos , Materiais Restauradores do Canal Radicular/farmacologia , Dimetil Sulfóxido , Cavidade Pulpar , Cálcio , Sulfato de Cálcio , Cimentos de Ionômeros de Vidro , Resinas Epóxi
13.
Aging Cell ; 23(3): e14061, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38105557

RESUMO

Once tooth development is complete, odontoblasts and their progenitor cells in the dental pulp play a major role in protecting tooth vitality from external stresses. Hence, understanding the homeostasis of the mature pulp populations is just as crucial as understanding that of the young, developing ones for managing age-related dentinal damage. Here, it is shown that loss of Cpne7 accelerates cellular senescence in odontoblasts due to oxidative stress and DNA damage accumulation. Thus, in Cpne7-null dental pulp, odontoblast survival is impaired, and aberrant dentin is extensively formed. Intraperitoneal or topical application of CPNE7-derived functional peptide, however, alleviates the DNA damage accumulation and rescues the pathologic dentin phenotype. Notably, a healthy dentin-pulp complex lined with metabolically active odontoblasts is observed in 23-month-old Cpne7-overexpressing transgenic mice. Furthermore, physiologic dentin was regenerated in artificial dentinal defects of Cpne7-overexpressing transgenic mice. Taken together, Cpne7 is indispensable for the maintenance and homeostasis of odontoblasts, while promoting odontoblastic differentiation of the progenitor cells. This research thereby introduces its potential in oral disease-targeted applications, especially age-related dental diseases involving dentinal loss.


Assuntos
Senilidade Prematura , Camundongos , Animais , Polpa Dentária , Senescência Celular/genética , Odontoblastos , Diferenciação Celular/genética , Camundongos Transgênicos
14.
J Clin Periodontol ; 40(4): 404-11, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23425208

RESUMO

AIM: The aim of this study was to evaluate and compare the osseointegration in rabbit tibiae of smooth and roughened powder injection moulded (PIM) zirconia implants with or without (Ti,Zr)O2 surface coatings. MATERIAL AND METHODS: Twenty-five rabbits received four types of external hex implants with identical geometry on the tibiae: PIM zirconia implants, roughened PIM zirconia implants, (Ti,Zr)O2 -coated PIM zirconia implants and (Ti,Zr)O2 -coated roughened PIM zirconia implants. The surface characteristics of the four types of implants were evaluated. Removal torque tests and histomorphometric analyses were performed. RESULTS: The (Ti,Zr)O2 coatings substantially changed the surface topography and chemical composition of the both type of PIM zirconia implants. There were statistically significant differences in the bone to implant contact ratios and removal torque values (RT) among the tested implant types (p < 0.001). The histological response favoured the coated surface at smooth PIM zirconia implants. The removal torque values favoured the rough surface whether coated or uncoated. CONCLUSIONS: Within the limit of this study, the (Ti,Zr)O2 coated PIM zirconia implants, both smooth and rough, showed enhanced histological response (bone to implant contact) compared with uncoated ones. On the other hand, the mechanical anchorage (RT) was higher for rough surface implants, coated or uncoated.


Assuntos
Materiais Revestidos Biocompatíveis , Implantes Dentários , Planejamento de Prótese Dentária , Osseointegração , Animais , Implantação Dentária Endóssea , Implantes Experimentais , Masculino , Coelhos , Propriedades de Superfície , Tíbia/cirurgia , Titânio , Torque , Zircônio
15.
Clin Oral Implants Res ; 24(5): 586-91, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-22471790

RESUMO

OBJECTIVE: To evaluate osseointegration in rabbit tibiae and to investigate surface characteristics of novel zirconia implants made by powder injection molding (PIM) technique, using molds with and without roughened inner surfaces. MATERIAL AND METHODS: A total of 20 rabbits received three types of external hex implants with identical geometry on the tibiae: machined titanium implants, PIM zirconia implants without mold etching, and PIM zirconia implants with mold etching. Surface characteristics of the three types of implant were evaluated. Removal torque tests and histomorphometric analyses were performed. RESULTS: The roughness of PIM zirconia implants was higher than that of machined titanium implants. The PIM zirconia implants exhibited significantly higher bone-implant contact and removal torque values than the machined titanium implants (P < 0.001). The PIM zirconia implants using roughened mold showed significantly higher removal torque values than PIM zirconia implants without using roughened mold (P < 0.001). CONCLUSIONS: It is concluded that the osseointegration of PIM zirconia implant is promising and PIM using roughened mold etching technique can produce substantially rough surfaces on zirconia implants.


Assuntos
Implantes Dentários , Implantes Experimentais , Osteogênese/fisiologia , Tíbia/cirurgia , Animais , Masculino , Microscopia Eletrônica de Varredura , Osseointegração , Pós , Coelhos , Propriedades de Superfície , Titânio , Torque , Zircônio
16.
Acta Odontol Scand ; 71(6): 1656-62, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23668244

RESUMO

OBJECTIVE: The aim of this study was to investigate the effect of heat treatment on the cyclic fatigue resistance, thermal behavior and microstructural changes of K3 NiTi rotary instruments. MATERIALS AND METHODS: Twelve control (as-received) and 12 experimental (heat-treated) K3 NiTi rotary instruments were compared in this study. Those experimental K3 instruments were heated in a furnace for 30 min at 450°C and then quenched in water. The cyclic fatigue resistance was measured with a fatigue tester. The thermal characteristic and the microstructures of both instruments were investigated by differential scanning calorimetry (DSC) and transmission electron microscopy (TEM), respectively. RESULTS: There was a significant increase in the cyclic fatigue resistance between the heat-treated instruments and the as-received instruments (T-test, p < 0.05). DSC showed that the as-received and heat-treated samples were different, with an increased Af (austenite-finish temperature) for the latter. TEM analysis revealed that both as-received and heat-treated instruments were composed mainly of an austenite phase. However, the heat-treated samples had an increased appearance of larger grains, twinning martensite, TiO2 surface layer and a Ni-rich inner layer. CONCLUSIONS: Heat treatment increased the cyclic fatigue resistance of NiTi files and changed the thermal behavior of the instruments without marked changes in the constituting phases of NiTi alloy.


Assuntos
Temperatura Alta , Teste de Materiais , Níquel/química , Titânio/química , Varredura Diferencial de Calorimetria , Microscopia Eletrônica de Transmissão , Propriedades de Superfície
17.
Am J Orthod Dentofacial Orthop ; 143(2): 274-80, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23374935

RESUMO

The patient was a 13-year-old Korean girl who had a displaced mandibular second premolar. She was reluctant to undergo a lengthy orthodontic treatment and opted instead for transplantation of the premolar to its usual site. On the basis of computed tomography, a replica tooth model was manufactured to shorten the extraoral time, and a root canal treatment was performed because root formation was complete. No negative signs or symptoms were found during a 3-year follow up. Autotransplantation for this patient obviated the need for orthodontic traction and prosthetic therapy.


Assuntos
Dente Pré-Molar/transplante , Tratamento do Canal Radicular/métodos , Erupção Ectópica de Dente/cirurgia , Alvéolo Dental/cirurgia , Adolescente , Cefalometria , Feminino , Seguimentos , Humanos , Mandíbula/cirurgia , Cirurgia Assistida por Computador , Esfoliação de Dente/fisiopatologia , Extração Dentária/métodos , Dente Decíduo , Transplante Autólogo , Resultado do Tratamento
18.
Front Physiol ; 14: 1313927, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38148896

RESUMO

Regenerative dentistry has rapidly progressed since the advancement of stem cell biology and material science. However, more emphasis has been placed on the success of tissue formation than on how well the newly generated tissue retains the original structure and function. Once dentin is lost, tertiary dentinogenesis can be induced by new odontoblastic differentiation or re-activation of existing odontoblasts. The characteristic morphology of odontoblasts generates the tubular nature of dentin, which is a reservoir of fluid, ions, and a number of growth factors, and protects the inner pulp tissue. Therefore, understanding the dynamic but delicate process of new dentin formation by odontoblasts, or odontoblast-like cells, following dentinal defects is crucial. In this regard, various efforts have been conducted to identify novel molecules and materials that can promote the regeneration of dentin with strength and longevity. In this review, we focus on recent progress in dentin regeneration research with biological molecules identified, and discuss its potential in future clinical applications.

19.
Chemosphere ; 343: 140104, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37696476

RESUMO

Resin-based dental composites have been developed to restore decayed teeth or modify tooth color due to their excellent physical and chemical properties. Such composites may have intrinsic toxicity due to components released into the mouth during the early stage of polymerization, and afterward as a result of erosion or material decomposition. In addition, resin-based dental composites have potential environmental pollutant by elution of monomers and degradation. Since certain monomers of resin matrices are synthesized from bisphenol A (BPA), which acts as an estrogenic endocrine disruptor, these resin matrices may have estrogenic activity. Therefore, the estrogenic endocrine-disrupting activity of various dental composites should be evaluated. In this study, we evaluated the estrogenic endocrine-disrupting activity of 10 resin composites by using a BRET-based estrogen receptor (ER)α and ERß dimerization assays and ER transactivation assay. BPA, BisDMA, BisGMA, BisEMA, TEGDMA, HMBP, and DMPA mediated ERα dimerization, and BPA, BisDMA, and DMPA also mediated ERß dimerization. Except for UDMA and CQ, all the compounds were identified as estrogen agonists or antagonists. In-depth information for the safe use of dental composites was acquired, and it was confirmed how the component of dental composites acts in the ER signaling pathway. Further studies on the low-dose and long-term release of these compounds are needed to ensure the safe use of these resin-based dental composites.

20.
Dent Mater J ; 42(4): 501-508, 2023 Aug 02.
Artigo em Inglês | MEDLINE | ID: mdl-37271544

RESUMO

Post-operative sensitivity (POS) is the most common clinical dental complaint after tooth preparation and resin-based composite restoration. In our previous study, copine 7 (CPNE7) and CPNE7-derived peptide (CPNE7-DP) induced in vitro odontoblast differentiation and in vivo dentin formation. Here, we incorporated CPNE7-DP into All-Bond Universal (ABU) adhesive, developing ABU/CPNE7-DP. This study aimed to investigate the possibility of reducing POS using ABU/CPNE7-DP. We first determined the stability of CPNE7-DP under low pH. Furthermore, we evaluated its dentinal tubule penetration, in vitro odontogenic differentiation potential, in vivo tertiary dentin formation and its effects on bonding performance. CPNE7-DP was stable at pH 1.2, even lower than ABU's pH of 3.2. ABU/CPNE7-DP can penetrate dentinal tubules, stimulate odontoblast differentiation in vitro and generate tertiary dentin with tubular structure in vivo without interfering with bonding performance. Therefore, ABU/CPNE7-DP may serve as a novel bioactive adhesive for reducing POS.


Assuntos
Colagem Dentária , Cimentos Dentários , Cimentos Dentários/farmacologia , Materiais Dentários , Peptídeos/farmacologia , Dentina , Adesivos Dentinários , Cimentos de Resina , Teste de Materiais , Resistência à Tração , Resinas Compostas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA