Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
1.
Faraday Discuss ; 218(0): 101-114, 2019 08 15.
Artigo em Inglês | MEDLINE | ID: mdl-31120047

RESUMO

The present research deals with the collection and structural elucidation of an unknown component, accounting for about 35% of the essential oil obtained upon distillation of the leaves of Eugenia uniflora L., harvested during summer (January, 2017) in Paraná State (Southern Brazil). A multidimensional gas chromatographic preparative system, based on the coupling of three GC systems equipped with apolar, PEG and ionic liquid-based stationary phases, was successfully applied for the isolation of the chromatographic band relative to the unknown molecule. The use of wide-bore columns allowed for an increased sample capacity compared to conventional micro-bore columns, thus the injection of a neat sample was feasible, greatly reducing the total collection time. A higher chromatographic efficiency was afforded by the use of a multidimensional approach in the heart-cut mode, exploiting the different selectivity of three stationary phases, which ensured the attainment of a highly pure fraction. In only five runs, more than 3 milligrams were collected, with an average purity greater then 95%. Finally, the unknown component was subjected to nuclear magnetic resonance spectroscopy, mass spectrometry and condensed phase Fourier-transform infrared spectroscopy, leading to the identification of 6-ethenyl-6-methyl-3,5-di(prop-1-en-2-yl)cyclohex-2-en-1-one. The presented approach has been demonstrated to be effective for the isolation and structural elucidation of unknown molecules in complex samples, which will allow for further in-depth studies, like biological evaluation or pharmacological tests.


Assuntos
Eugenia/química , Líquidos Iônicos/química , Óleos Voláteis/análise , Cromatografia Gasosa , Conformação Molecular
2.
Anal Bioanal Chem ; 410(19): 4633-4643, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29214537

RESUMO

Twelve bis- or dicationic ionic liquids (ILs) including eight based on imidazolium, a single one based on phosphonium, and three based on pyrrolidinium cationic units were prepared with the bis(trifluoromethyl sulfonyl) imide anion. The two identical cationic moieties were attached by different alkyl spacers having three or five carbons and differing alkyl substituents attached to the spacer. The SLB-IL111 column, as the most polar commercial stationary phase known, was included in the study for comparison. Isothermal separations of a rapeseed oil fatty acid methyl ester (FAME) sample were used to study and compare the 12 IL-based column performances and selectivities. The retention times of the most retained methyl esters of lignoceric (C24:0) and erucic (C22:1) acids were used to estimate the IL polarity. The phosphonium dicationic IL column was, by far, the least polar. Imidazolium-based dicationic IL columns were the most polar. Polarity and selectivity for the FAME separation were somewhat related. The separation of a 37-FAME standard mixture allowed the investigation of selectivity variations observed on the 12 IL-based columns under temperature gradients up to 230 °C. The remarkable selectivity of the IL-based columns is demonstrated by the detailed analysis of the cis/trans C18:1 isomers of a partially hydrogenated vegetable oil sample on 30-m columns, separations competing with that done following an "official method" performed on a 100-m column. Graphical abstract Separation of fatty acid methyl esters on a 30-m 3m2C5(mpy)2. 2NTf2 branched-chain dicationic IL-based column. Branched chain dicationic ILs show great selectivity for separation of cis/trans, ω-3/ω-6, and detailed analysis of cis/trans fats.

3.
Anal Bioanal Chem ; 410(19): 4763-4764, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29862431

RESUMO

The authors would like to call the reader's attention to the fact that the original publication included some corrections needed to be addressed.

4.
J Sep Sci ; 41(22): 4142-4148, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30259657

RESUMO

Three phosphonium-based dicationic ionic liquids were synthesized as bis(trifluoromethylsulfonyl) imide salts. The three dications had a nonyl spacer between two identical phosphonium-substituted groups. The three phosphonium moieties were dipropyl(phenyl), diphenyl(propyl), and diphenyl(toluyl). The physicochemical properties of the dicationic ionic liquids were appropriate to prepare 30 m capillary columns that were tested in gas chromatography. A unique selectivity compared to different polysiloxane or polar cyanosiloxane commercial columns was observed for selected mixes of phthalates, polyaromatic hydrocarbons, polychlorobiphenyls, and dioxins. Only minor selectivity variations were observed with the three dicationic ionic liquids. The different number of aromatic rings on the positively charged phosphonium group did not influence the dicationic ionic liquid selectivity significantly.

5.
Anal Chem ; 83(15): 6018-25, 2011 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-21711040

RESUMO

Biocompatible C18-polyacrylonitrile (PAN) coating was used as the extraction phase for an automated 96-blade solid phase microextraction (SPME) system with thin-film geometry. Three different methods of coating preparation (dipping, brush painting, and spraying) were evaluated; the spraying method was optimum in terms of its stability and reusability. The high-throughput sample preparation was achieved by using a robotic autosampler that enabled simultaneous preparation of 96 samples in 96-well-plate format. The increased volume of the extraction phase of the C18-PAN thin film coating resulted in significant enhancement in the extraction recovery when compared with that of the C18-PAN rod fibers. Various factors, such as reusability, reproducibility, pH stability, and reliability of the coating were evaluated. The results showed that the C18-PAN 96-blade SPME coating presented good extraction recovery, long-term reusability, good reproducibility, and biocompatibility. The limits of detection and quantitation were in the ranges of 0.1-0.3 and 0.5-1 ng/mL for all four analytes.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Microextração em Fase Sólida/métodos , Espectrometria de Massas em Tandem/métodos , Resinas Acrílicas/química , Automação , Benzodiazepinas/análise , Benzodiazepinas/sangue , Benzodiazepinas/isolamento & purificação , Humanos , Concentração de Íons de Hidrogênio
6.
Anal Chem ; 81(1): 160-73, 2009 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-19067539

RESUMO

Trigonal tricationic ionic liquids (ILs) are a new class of ILs that appear to be unique when used as gas chromatographic stationary phases. They consist of four core structures; (1) A = mesitylene core, (2) B = benzene core, (3) C = triethylamine core, and (4) D = tri(2-hexanamido)ethylamine core; to which three identical imidazolium or phosphonium cationic moieties were attached. These were coated on fused silica capillaries, and their gas chromatographic properties were evaluated. They were characterized using a linear solvation parameter model and a number of test mixtures. On the basis of the literature, it is known that both monocationic and dicationic ILs possess almost identical polarities, solvation characteristics, and chromatographic selectivities. However, some of the trigonal tricationic ILs were quite different. The different solvation parameters and higher apparent polarities appear to generate from the more rigid trigonal geometry of these ILs, as well as their ability to retain the positive charges in relatively close proximity to one another in some cases. Their unique selectivities, retention behaviors, and separation efficiencies were demonstrated using the Grob mixture, a flavor and fragrance test mixture, alcohols/alkanes test, and FAME isomer separations. Two ILs C1 (methylimidazolium substitution) and C4 (2-hydroxyethylimidazolium substitution) had higher apparent polarities than any know IL (mono, di, and tricationic ILs) or commercial stationary phases. The tri(2-hexanamido)ethylamine core IL series proved to be very interesting in that it not only showed the highest separation efficiency for all test mixtures, but it also is the first IL stationary phase (containing NTf(2)(-) anions) that eliminates peak tailing for alcohols and other H-bonding analytes. The thermal stabilities were investigated using three methods: thermogravimetric analysis (TGA) method, temperature programmed gas chromatographic method (TPGC), and isothermal gas chromatographic method. The D core series had a high working temperature range, exceptional selectivities, and higher separation efficiencies than comparable polarity commercial columns. It appears that this specific type of multifunctional ILs may have the most promising future as a new generation of gas chromatographic stationary phases.

7.
Anal Chem ; 81(13): 5561-8, 2009 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-19480396

RESUMO

The present research is focused on the evaluation of one 0.10 mm i.d. and two 0.25 mm i.d., ionic liquid (IL) stationary phase [1,9-di(3-vinyl-imidazolium) nonane bis(trifluoromethyl) sulfonyl imidate] columns, with lengths of 12 (the microbore capillary), 30 and 100 m, in the GC analysis of cis/trans fatty acid methyl esters (FAMEs). The selectivity of the IL columns toward a series of standard C(18:1), C(18:2), and C(18:3) geometric isomers (a group of 22 compounds was subjected to GC analysis) was compared to the performance of a widely used column in the cis/trans FAMEs analysis field, viz., a 100 m x 0.25 mm i.d. capillary with a 0.20 microm stationary phase film of bis-cyanopropyl polysiloxane (SP-2560). The selectivity provided by the IL phase was superior if compared to that of the other well-established capillary. An optimized IL method, using the longer column, was subjected to validation: retention time and peak area intraday precision (n = 5) were good, with RSD values lower than 0.07% and 6.6%, respectively; LODs (considering a S/N of 3) for C(18:1Delta)(9tr) and C(18:2Delta)(9tr,12tr) were 0.15 (7.3 ppm) and 0.18 ng (9.1 ppm) on-column, respectively, while LOQs (considering a S/N of 10) were 0.49 (24.3 ppm) and 0.60 ng (30.2 ppm), respectively; the method was found to be linear, for both trans FAMEs, in the 10-2000 ppm range. For the evaluation of accuracy, a hydrogenated margarine, spiked with known amounts of C(18:3Delta)(9c,12c,15c), was subjected to analysis using C(13:0) as an internal standard.


Assuntos
Cromatografia Gasosa/métodos , Líquidos Iônicos/química , Ácidos Graxos trans/análise , Estudos de Avaliação como Assunto , Isomerismo
8.
Anal Chim Acta ; 1042: 155-164, 2018 Dec 26.
Artigo em Inglês | MEDLINE | ID: mdl-30428982

RESUMO

Dicationic ionic liquids (DILs) are more and more accepted as a new class of high temperature and polar stationary phases for gas chromatography (GC). This study deals with the effect of seven different fluorosulfonyl derivatized anions associated with two dications: 1,3-di(3-methylimidazolium)-2-methylpropane [2mC3(mim)2], and 1,3-di(3-methylimidazolium)-isobutene [i-eneC4(mim)2]. Thermophysical properties of the 14 synthesized DILs were evaluated in terms of melting point, viscosity, and thermal stability. The optimal physicochemical properties of 13 DILs allowed preparing 13 GC capillary columns. Accordingly, the polarity and selectivity of the DILs were evaluated by determining the Rohrschneider-McReynolds constants and the equivalent chain lengths of C18 fatty acid methyl esters (FAMEs). The symmetrical fluoroalkylsulfonyl and the trifluorosulfonate anions seem to produce the most polar DILs. Compared to classical polyethyleneglycol phases, the DILs showed substantially decreased retention of apolar compounds and a much stronger retention of the polar ones. Unique selectivities were observed with unsaturated FAMEs, polyaromatic hydrocarbons, and bacterial specific FAMEs. The two applications presented included a biodiesel and bacterial FAME analyses.


Assuntos
Cromatografia Gasosa/métodos , Ésteres/análise , Ácidos Graxos/análise , Líquidos Iônicos/química , Hidrocarbonetos Policíclicos Aromáticos/análise , Ânions/química , Cátions/química , Estrutura Molecular , Temperatura
9.
J Chromatogr A ; 1485: 120-130, 2017 Feb 17.
Artigo em Inglês | MEDLINE | ID: mdl-28089272

RESUMO

Retention indices for 48 polycyclic aromatic sulfur heterocycles (PASHs) were determined using gas chromatography with three different stationary phases: a 50% phenyl phase, a 50% liquid crystalline dimethylpolysiloxane (LC-DMPS) phase, and an ionic liquid (IL) phase. Correlations between the retention behavior on the three stationary phases and PASH geometry (L/B and T, i.e., length-to-breadth ratio and thickness, respectively) were investigated for the following four isomer sets: (1) 4 three-ring molecular mass (MM) 184Da PASHs, (2) 13 four-ring MM 234Da PASHs, (3) 10 five-ring MM 258Da PASHs, and (4) 20 five-ring MM 284Da PASHs. Correlation coefficients for retention on the 50% LC-DMPS vs L/B ranged from r=0.50 (MM 284Da) to r=0.77 (MM 234Da). Correlation coefficients for retention on the IL phase vs L/B ranged from r=0.31 (MM 234Da) to r=0.54 (MM 284Da). Correlation coefficients for retention on the 50% phenyl vs L/B ranged from r=0.14 (MM 258Da) to r=0.59 (MM 284Da). Several correlation trends are discussed in detail for the retention behavior of PASH on the three stationary phases.


Assuntos
Compostos Heterocíclicos com 3 Anéis/química , Compostos Heterocíclicos de 4 ou mais Anéis/química , Tiofenos/química , Cromatografia Gasosa/métodos , Dimetilpolisiloxanos , Líquidos Iônicos , Isomerismo , Peso Molecular
10.
J Chromatogr A ; 1484: 73-84, 2017 Feb 10.
Artigo em Inglês | MEDLINE | ID: mdl-28089274

RESUMO

Retention indices for 10 sets of alkyl-substituted polycyclic aromatic sulfur heterocycles (PASHs) isomers (total of 80 PASHs) were determined using gas chromatography with three different stationary phases: a 50% phenyl phase, a 50% liquid crystalline dimethylpolysiloxane (LC-DMPS) phase, and an ionic liquid (IL) phase. Correlations between the retention behavior on the three stationary phases and PASH geometry [length-to-breadth (L/B) and thickness (T)] were investigated for the following PASHs: 4 methyl-substituted dibenzothiophenes (DBTs), 3 ethyl-substituted DBTs, 15 dimethyl-substituted DBTs, 8 trimethyl-substituted DBTs, 15 methyl-substituted naphthothiophenes, 30 methyl-substituted benzonaphthothiophenes, and 5 methyl-substituted tetrapheno[1,12-bcd]thiophene. Correlation coefficients for retention on the 50% phenyl phase vs L/B ranged from r=-0.28 (MeBbN23Ts) to r=0.92 (EtDBTs). Correlation coefficients for retention on the IL phase vs L/B ranged from r=0.13 (MeN12Ts) to r=0.83 (EtDBTs). Correlation coefficients for retention on the 50% LC-DMPS phase vs L/B ranged from r=0.22 (MeDBTs) to r=0.84 (TriMeDBTs).


Assuntos
Cromatografia Gasosa , Hidrocarbonetos Policíclicos Aromáticos/química , Enxofre/química , Dimetilpolisiloxanos/química , Isomerismo , Tiofenos/química
12.
Anal Chim Acta ; 817: 23-7, 2014 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-24594813

RESUMO

A modified Rheodyne 7520 microsample injector was used as a new solid phase microextraction (SPME)-liquid chromatography (LC) interface. The modification was focused on the construction of a new sample rotor, which was built by gluing two sample rotors together. The new sample rotor was further reinforced with 3 pieces of stainless steel tubing. The enlarged central flow passage in the new sample rotor was used as a desorption chamber. SPME fiber desorption occurred in static mode. But all desorption solvent in the desorption chamber was injected into LC system with the interface. The analytical performance of the interface was evaluated by SPME-LC analysis of PAHs in water. At least 90% polycyclic aromatic hydrocarbons (PAHs) were desorbed from a polyacrylonitrile (PAN)/C18 bonded fuse silica fiber in 30s. And injection was completed in 20s. About 10-20% total carryovers were found on the fiber and in the interface. The carryover in the interface was eliminated by flushing the desorption chamber with acetonitrile at 1mL min(-1) for 2min. The repeatability of the method was from 2% to 8%. The limit of detection (LOD) was in the mid pg mL(-1) range. The linear ranges were from 0.1 to 100ng mL(-1). The new SPME-LC interface was reliable for coupling SPME with LC for both qualitative and quantitative analysis.

13.
Anal Chim Acta ; 803: 166-73, 2013 Nov 25.
Artigo em Inglês | MEDLINE | ID: mdl-24216211

RESUMO

Due to their distinct chemical properties, the application of ionic liquid (IL) compounds as gas chromatography (GC) stationary phases offer unique GC separation especially in the analysis of geometric and positional fatty acid methyl ester (FAME) isomers. Elution behaviour of FAME on several commercialised IL capillary columns including phosphonium based SLB-IL59, SLB-IL60, SLB-IL61 and SLB-IL76 and imidazolium based SLB-IL82, SLB-IL100, and SLB-IL111 as well as a general purpose column SLB-5ms, were evaluated in gas chromatography-mass spectrometry (GC-MS) analysis. The phases were further characterised by using a linear solvation energy relationship (LSER) approach according to the equivalent chain length (ECL) index of FAME. Among all tested IL columns, elution temperatures of saturated FAME increased as their McReynolds' polarity value decreased, except for IL60. ECL values increased markedly as the stationary phase polarity increased, particularly for the polyunsaturated FAME. The LSER study indicated a lowest l/e value at 0.864 for IL111, displaying phase selectivity towards unsaturated FAME, with higher peak capacity within a carbon number isomer group. s and e descriptors calculated from LSER were validated by excellent correlation with dipole moments and lowest unoccupied molecular orbital (LUMO) energies, with R(2) values of 0.99 and 0.92 respectively, calculated using GAUSSIAN.


Assuntos
Ácidos Graxos/isolamento & purificação , Cromatografia Gasosa-Espectrometria de Massas/métodos , Líquidos Iônicos/química , Ésteres , Ácidos Graxos/química , Isomerismo , Metilação , Modelos Moleculares
14.
Anal Chim Acta ; 743: 61-8, 2012 Sep 19.
Artigo em Inglês | MEDLINE | ID: mdl-22882824

RESUMO

Modifications were made on commercial SPME fiber assembly and SPME-LC interface to improve the applicability of SPME for LC. Polyacrylonitrile (PAN)/C18 bonded fuse silica was used as the fiber coating for LC applications because the fiber coating was not swollen in common LC solvents at room temperature. The inner tubing of SPME fiber assembly was replaced with a 457 µm outside diameter (o.d.) solid nitinol rod. And the coated fiber (o.d. 290 µm) was installed onto the nitinol rod. The inner diameter (i.d.) of the through hole of the ferrule in the SPME-LC interface was enlarged to 508 µm to accommodate the nitinol rod. The much larger inner rod protected the fiber coating from being stripped when the fiber was withdrawn from the SPME-LC interface. The system was evaluated in term of pressure test, desorption optimization, peak shape, carryovers, linear range, precision, and limit of detection (LOD) with polycyclic aromatic hydrocarbons (PAHs) as the test analytes. The results demonstrated that the improved system was robust and reliable. It overcame the drawbacks, such as leak of solvents and damage of fiber coatings, associated with current SPME fibers and SPME-LC interface. Another sealing mechanism was proposed by sealing the nitinol rod with a specially designed poly(ether ether ketone) (PEEK) fitting. The device was fabricated and tested for manual use.

15.
J Chromatogr A ; 1218(38): 6817-22, 2011 Sep 23.
Artigo em Inglês | MEDLINE | ID: mdl-21855074

RESUMO

Furaneol is an important aroma compound. It is very difficult to extract furaneol from food matrices and separate it on a gas chromatography column due to its high polarity and instability. A new quantitative method was developed to quantify furaneol in aqueous samples by the use of derivatization/solid phase microextraction (SPME) coupled with gas chromatography/mass spectrometry (GC/MS). The derivatization was carried out by reacting pentafluorobenzyl bromide with furaneol in basic solutions at elevated temperatures. The derivative was stable and less polar so that SPME-GC/MS could be applied for extraction, separation and detection. The automated analytical method had a limit of detection (LOD) of 0.5 ng mL(-1), a limit of quantification (LOQ) of 2 ng mL(-1), a repeatability of 9.5%, and a linear range from 2 to 500 ng mL(-1). The method was applied to analyze fruit samples. And it was found that the concentrations of furaneol in tomato ranged from 95 to 173 µg kg(-1), in strawberries ranged from 1663 to 4852 µg kg(-1). The results were verified with a LC procedure. To facilitate analytical method development, some physico-chemical parameters for furaneol were determined in this work. Its solubility in water was determined as 0.315 g mL(-1) (25°C). Its LogD in water and LogP in 0.1 M phosphate buffer were -0.133 and 0.95 (20 °C), respectively. Its pKa was 8.56 (20 °C).


Assuntos
Frutas/química , Furanos/análise , Furanos/isolamento & purificação , Cromatografia Gasosa-Espectrometria de Massas/métodos , Microextração em Fase Sólida/métodos , Compostos Orgânicos Voláteis/análise , Compostos Orgânicos Voláteis/isolamento & purificação , Análise de Alimentos , Furanos/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA